IF Cable Grounding
Determine IF Cable Grounding Position
Notes:
At least three grounding points are needed for one IF
cable grounding. The first grounding point (Point 1) is about 1M away from the IF interface of ODU. The second point (Point 2) is about 1M away from the horizontal cable tray. Point 3 is about 0.5M~1M away from the feeder window.
HUAWEI TECHNOLOGIES CO., LTD.
Huawei Confidential
Page 3
IF Cable Grounding
Perform the IF Cable Grounding
Key Steps:
Strip the sheath off the IF
①
②
③
cable according to the length of the grounding clip. Fit the grounding clip where the sheath is stripped off on the IF cable, and then tighten the screws.
cable according to the length of the grounding clip. Don't strip any shielding layer of the IF cable.
Page 4
IF Cable Grounding
Waterproof of IF Cable Grounding Points
Notes:
Wrap the connector with three
12
3 ①
PVC Tape
12
3
Waterproof Tape
12 ②
3
PVC Tape
③
layers of PVC tape, water-proof tape and PVC tape 3–5 cm below the connector and toward the direction of the ODU. The wrapping directions of the three layers are from down to up, from up to down, and from down to up 3 times respectively.
When wrap the waterproof tape, it must be pulled forcefully at the same time. Pulled forcefully
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Page 5
IF Cable Grounding
Waterproof of IF Cable Grounding Points
Cable ties should be used
Cable ties keep the same direction. After complete the tapes wrapping,
cable ties must be used on both ends of grounding point, and reserve spare length.
HUAWEI TECHNOLOGIES CO., LTD.
Huawei Confidential
Page 6
IF Cable Grounding
Grounding of IF Cable
Grounding cable must be downward along the IF cable
Before fix the grounding cable to tower, remove the paint is needed.
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential