Substation Automation Solutions SAS 600 Series

 ABB’s SAS 600 Series More than IEC 61850 compliant

The highlights of ABB’s SAS 600 Series •

Fully IEC 61850 compliant substation automation solutions



Flexible station bus topologies including multiple networks



State-of-the-art station HMI based on ActiveX technology



Scalable architecture and functionality



Integration of control and protection



Simplified future extendibility in functionality and size



Open connectivity through OPC interfaces



Implementation and system performance proven by in-house System Verification Center

 The SAS 600 Seri es o f modular station level solu tions is designed for maximum safety, efficiency and reliability in local as well as remote control and monitoring of your substation. It incorporates ABB’s market-leading experience in substation automation and protection, vast expertise in IEC 61850 and proven system integration capabilities.  The seri es o ffers a sm art choi ce f or n ew s tati ons, ret rofit and migration projects and the confidence that you can invest into the future today.  The SAS600 S eries together with BCS 600 Series Bay Control Solutions and BPS 600 Series Bay Protection Solutions is the ultimate and most efficient strategy to build substation automation systems.

 The SAS solutio n portfoli o ra nges from compact solu tions f or the safe control and monitoring of your substation to the most demanding applications where single points of failure are not tolerable and highest levels of availability are a necessity.

a St

 A d

n va

n tio

ce

L

e ev

ol u S l

 A S S d E

a nh

nc

90 0 6 35 7 6 S 6 0  /  S A   A S 65 630 S S 10 05 S A  S A S 6 S 6 S A  S A S

ns o i t

Re d u

Re d u

Ind e p

S S A  d e B

i as

e nd e

nd St a

ar

ti o Op

t sta t

nt e m

 A dva nced c o ntr  A dva ol nc e d mo ni Ba si c t ori n g c o ntr ol Basic m on i t or i n g Stati on H MI Re mo t e co n t rol d

 A S S c

Customer requirements

nd a n

nd a n

t ga t e i on H

be d d

wa y

MI

ed ga t

n

SAS 605

SAS 610

SAS 630/635

SAS 650

SAS 670

SAS 690













Optio n

Optio n

Optio n

Optio n

Optio n

Functionality Basic control and monitoring of substations  Advan ced c ontro l and monit oring funct ions Operation Remote only



Local only



Local and remote with priority on local Local and remote with priority on remote



Option Option

• •

Local and remote with equally high priority

Option



Extra-high voltage transmission





Complex distribution





Recommended application

Substation Distribution and subtransmission High voltage transmission



• •





e wa y

Station level solution based on IEC 61850 in a substation automation environment

Maintenance

Station level (Example SAS 690) Hardcopy printer

Event printer

Workstation

GPS/Time server

center Redundant station HMI

Station alarm device

01

Firewall/   VPN

Remote control center Gateway   Router/ firewall/VPN

Gateway   Router/ firewall/VPN

0

Redundant gateway

Station LAN Redundant station computer

Option

IEC 61850-8-1

Bay level

Bay Protection and Bay Control Solutions

 Transmission substation

Proxy I/O

 Alternative master protocols

Bay level Subtransmission substation

Bay Protection and Bay Control Solutions

Modular, scalable architecture

 Advanced SAS – for extr a high voltage and complex tr ans mis sio n subs tati ons

Main components

SAS690 Highest availability of local and remote control through separation as well as full redundancy of gateway and station computer / HMI

Station computer/HMI MicroSCADA Pro (SYS600)

SAS670 Highest availability of local control provided by two redundant station computers in hot stand-by configuration with option for remote control

Station computer/ HMI with integrated gateway MicroSCADA Pro (SYS600 plus COM500i)

Enhanced SAS – for high voltage transmission substations Independent gateway MicroSCADA Pro (SYS600C )

SAS650 For manned substations with completely independent HMI and gateway functionality using redundant station computers for local control and monitoring

Station controller RTU560

SAS630 For unmanned substations with completely independent station computer / HMI and a highly reliable industrial gateway for remote control

SAS635 For unmanned substations with completely independent station computer / HMI and a RTU based station controller for remote control

Basic SAS – for distribution and subtransmissi on substations SAS610 Compact solution featuring an industrial PC for local control and monitoring with optional access for remote control

SAS605 Compact and flexible solution for remote control using a RTU

Integrated HMI RTU560

 Advanced functionalities

Trends − Short-term observation and analysis −  Assignment o f any process va lues − Graphical or tabular representation − Calculation formulae

Dynamic busbar coloring − Dynamic coloring of the different switchgear parts − One color per power source − Enhanced overview for complex substations

Measurement reports − Statistical measurement reports stored in report database − Hourly/daily/weekly/monthly/yearly report −  Tabular or graphical repr esentatio n − Report data in ASCII or CSV format − Sum, mean, average, min., max.

 Auto matic sequen ces − Execution of pre-defined switching sequences − Safety checks (same as for switching of individual objects) − Freely configurable sequences

IED parameterization − Configuration/parameter upload  from IED − Change of individual parameters or parameter sets −  Acc ess to all IED para met ers

Load shedding − Control at bay level, configuration and supervision at station level − Static load shedding −  Adaptive load sh edding

Disturbance record upload − Manual upload − Cyclic upload − Event-driven upload

l

l l

l

l l

Disturbance record analysis −  Waveform visualiz ations, sign al  vector s − Fault location, advanced calculation − Frequency deviation, apparent and reactive power calculation −  Aut omatic analysi s Teleph Fi x ed one Te lepho Mobi ne le

Trip counter table − Maintenance information for CBs − Numbers of opening operations −  Acc umulated magnit ude of the trip currents

Shor t Messa ( SMS ges  )

Statio Com n puter

Publi S y stec Paging ms

Fa x  e-ma il

High-speed busbar transfer  − Change-over of motor-feeding busbar  from normal to backup supp ly and  vice versa − Control at bay level, configuration and supervision at station level

External alarming − Fax, voice message − SMS, pager system − E-mail

Contact us

 ABB Switzerla nd Ltd Power Systems Bruggerstrasse 72 CH-5400 Baden, Switzerland Phone: +41 58 585 77 44 Fax: +41 58 585 55 77 E-Mail: [email protected] www.abb.com/substationautomation

 .    d   e   v   r   e   s   e   r   s    i   s   s   e   r   g   o   r   p    l   a   c    i   n    h   c   e    t   o    t   e   u    d   s   n   o    i    t    d   i   n   a   a   v    l   e   r    d   e   r   z    t    i   o   w  s    S  n   o   n   i    t    i    d   a   c   e   f    i    t   n   d    i   r   o    P  m     o    9   t    0  .    t    h    0   i    1   g   r   -   e    0   h    0   T    0  .    1   9    0    0    2   r   e    b    N   t   o    E   c    S   O   -  ,    4    d  .    t   s   r    L   e   d   v   n  ,   a    9   l   r    6   e   z    0   t    i    1   w    0    0   S   -   B    A   B    H   A    K    1   ©

Sponsor Documents

Or use your account on DocShare.tips

Hide

Forgot your password?

Or register your new account on DocShare.tips

Hide

Lost your password? Please enter your email address. You will receive a link to create a new password.

Back to log-in

Close