BILL OF QUANTITY FOR THE HVAC WORKS OF
The Institute of space technology, near Toll Plaza (G.T. Road,) Islamabad
PLEASE MARK TICK ON LEFT BOX WHICH EQUIPMENT YOU HAVE QUOTED
PROPOSAL BASED ON CHINESE EQUIPMENT
PROPOSAL BASED ON JAPANESE, KORIAN OR MALAYSIAN EQUIPMENT
Sr
Supply and installation of fresh air special
type Air Cooled Self Contained air
Conditioning unit capacity having of 30
tons with steam humidifier complete with
all accessories as per schedule of technical
particular & shown on the drawings or as
approved by the Engineer/Consultant.
2
No.
Supply and installation of following air
cooled Multi Digital Scroll (MDS) Reversible
(Heat & Cool) type outdoor air
conditioning unit complete with all
accessories as per schedule of technical
particular & as shown on the drawings and
as approved by the Engineer/Consultant:
1
2
Sr
Description
Supply and installation of following Indoor
DX Ceiling decorative Fan Coil Unit (FCU)
including appropriate size copper piping
between indoor and outdoor unit
complete with all accessories as per
schedule of technical particular shown on
the drawing # 1, including expection valves
and y connectors and or as approved by
the Engineer/Consultant.
Basement floor
Ceiling suspended Cassette type
Cooling/Heating unit Cooling capacity 2
tons Unit # 1 to 25.
Lower Ground Floor
Wall mounted type Cooling /Heating unit
Cooling capacity 1.5 tons Unit # 26 to 41.
Ceiling suspended Cassette type
Cooling/Heating unit Cooling capacity 2
tons for Lower Ground Floor Unit # 42 to
43.
Ceiling suspended Cassette type
Cooling/Heating unit Cooling capacity 1.5
tons for Lower Ground Floor Unit # 44 to
57.
Wall mounted type Cooling/Heating unit
Cooling capacity 1.5 tons for Lower Ground
Floor Unit # 58 to 73.
Upper Ground Floor
Ceiling suspended Cassette type
Cooling/Heating unit Cooling capacity 1.5
tons Unit # 74 to 84.
Ceiling suspended Cassette type
Cooling/Heating unit Cooling capacity 2
tons Unit # 85 to 92.
Ceiling suspended Cassette type
Cooling/Heating unit Cooling capacity 1.0
ton Unit # 93 to 94.
Qty
Unit
25
No.
16
No.
2
No.
14
No.
16
No.
11
No.
8
No.
2
No.
Rate
Amount
Sr
3
Description
Ceiling suspended Cassette type
Cooling/Heating unit Cooling capacity 2
tons Unit # 95 to 125.
Ceiling suspended Cassette type
Cooling/Heating unit Cooling capacity 1.0
ton Unit # 126 to 127.
Ceiling suspended Cassette type
Cooling/Heating unit Cooling capacity 2
tons Unit # 128 to 140.
First Floor
Ceiling suspended Cassette type
Cooling/Heating unit Cooling capacity 2
tons Unit # 141 to 151.
Ceiling suspended Cassette type
Cooling/Heating unit Cooling capacity 1
tons Unit # 152.
Ceiling suspended Cassette type
Cooling/Heating unit Cooling capacity 2
tons Unit # 153 to 157.
Vertical Floor standing type Cooling/
Heating unit Cooling capacity 1.5 tons Unit
# 158 A, 158 B, 159 A, 159 B, 160 A & 160
B.
Ceiling suspended Cassette type
Cooling/Heating unit Cooling capacity 2
tons Unit # 161 to 163.
Ceiling suspended Cassette type
Cooling/Heating unit Cooling capacity 1.5
tons Unit # 164 to 165.
Ceiling suspended Cassette type
Cooling/Heating unit Cooling capacity 2
tons Unit # 166 to 193.
Scond Floor
Ceiling suspended Cassette type Cooling
/Heating unit Cooling capacity 2 tons Unit
# 194 to 205.
Ceiling suspended Cassette type Cooling
/Heating unit Cooling capacity 1.5 tons
Unit # 206 to 209.
Qty
Unit
32
No.
2
No.
13
No.
11
No.
1
No.
5
No.
6
No.
3
No.
2
No.
28
No.
12
No.
4
No.
Rate
Amount
Sr
4
5
6
7
Description
Ceiling suspended Cassette type Cooling
/Heating unit Cooling capacity 2 tons Unit
# 210 to 228.
Supply and installation of sheet metal
ducting complete in all respect as shown
on the drawings, complete with
accessories hangers, supports & as
approved by the Engineer/Consultant:
22 Guage
24 Guage
26 Guage
Supply & installation of following
Aluminium Foil Fiber Glass 16kg/m3
density) insulation wrapped with
Aluminium tape and shall be protected
with 8 oz canvas, complete in all respect as
shown on the drawings & as shown on the
drawings as as approved by the
engineer/consultant:
Sound liner 1'' thick
Thermal insulation 1'' thick
Thermal insulation 2'' thick
Supply & installation of Refnet Y
Connectors as per specification and
thickness shall not be less than 18 guage
(include price in item # 3)
Supply and Installation of refrigerant pipes
type L thickness not less than 20 gauge
(Liquid+Gas) with expanded rubber foam
insulation for Multi Split type A/C units
from each FCU to outdoor units installed
on roof top, including control wirring,
Flushing, gas charging, hangers, supports
and brackets of following sizes all
refrigerant pipes should be in PVC Dura
Duct as approved by the
Engineer/consultant:
6.35mm x t0.8
9.52 mm x t0.8
Qty
Unit
24
No.
2500
18528
1250
Sq. ft
Sq. ft
Sq. ft
2860
17150
1860
Sq. ft
Sq. ft
Sq. ft
1
Lot
1450
1850
Rft
Rft
Rate
Amount
Sr
Description
12.7 mm x t1.0
15.88 mm x t1.2
19.05 mm x t1.2
28.6 mm x t1.2
41.3 mm x t1.6
34.9 mm x t1.4
22.2 mm x t1.2
8
Supply and Installation of PVC condensate
drain pipe with insulation from each FCU
to condensate tank in basement) complete
in all respect ready to operate as approved
by the Engineer/Consultant
supply & installation of Communication
9 cable between all indoor units and
outdoor units complete in all respect, as
approved by the Engineer/ Consultant.
Supply and installtion of Aluminium
Registers for supply of fresh air and
exhaust air of following sizes, complete in
all respect, support and other accessories
etc. Make: Steel Craft, as approved by the
Consultant:
10
For Basement floor SAD 24"x6"
For Lower Ground Floor SAD 24'' x 6''
For Upper Ground floor SAD 24''x 6''
For First Floor SAD 24'' x 6''
For First Floor SAD 24'' x 12''
For Second Floor SAD 24'' x 3''
Supply and Installation of Electronic Expan‐
sion valve (EXV) as per manufacturer's
11 recommwndation and approved by the
Engineer/consultant include in indoor units
item # 3.
Qty
Unit
1450
3320
702
710
270
650
100
Rft
Rft
Rft
Rft
Rft
Rft
Rft
1
Lot
1
Lot
3
3
9
22
12
9
No.
No.
No.
No.
No.
No.
1
Lot
Rate
Amount
Sr
Description
Supply and installation of Best quality PVC
water tank 500 gallons (normally used as
overhead tank) for condensate including
12 level automatic controller with upper and
lower level sensor complete in all respect
location is in the lift well on basement as
approved by the Engineer/consultant.
Supply & installation of Centrifugal Pump
25 gpm against (20 ft head) as specified
suitable to throw condensate water
13 collected in the tank from basement to
lower ground floor in open space as shown
on the drawings through automatic water
level controller complete in all respect and
as approved by the Engineer/ consultants.
Supply and installtion of electrical DB for
air conditioning with incoming and
outgoing circuit breakers with AEG/
Hager/Terasaki/Fuji/BB including bus bar
volt & Ampere meters, selector switch
phase indicator lamps complete in all
respect approved equivalent by the
14
engineer/consultant of following capacity
Incoming 1500 ATP MCCB
Outgoing 200 ATP MCCB
Outgoing 150 ATP MCCB
Outgoing 130 ATP MCCB
Outgoing 125 ATP MCCB
Outgoing 100 ATP MCCB
Outgoing 80 ATP MCCB
Qty
Unit
1
No.
1
No.
1
No.
1
11
5
2
3
3
3
No.
No.
No.
No.
No.
No.
No.
Rate
Amount
Sr
Description
Supply and installation of copper
conductor power cables make by Pakistan
Cables/ AEG Cables/ New Age cables or
approved equivalent cables by the
Consultant in cable tray from DB to all out
door units installed on roof as shown on
the drawings, complete in all respect as
15 and as approved by the
Engineer/consultant as detailed below:
3.5 core 300 mm sq
3.5 core 35 mm sq
3.5 core 30 mm sq
3.5 core 18 mm sq
3.5 core 16 mm sq
3.5 core 10 mm sq
3.5 core 8 mm sq
Construct, fabricate and install Foundation
16 structure for frame for placing condensing
units in consultation with structural
Engineer of the client.
Supply of Manufacture's essential spare
17 parts for all above items for 2 years normal
operation as approved by the engineer/
Consultant (Provide list)
Supply of Digital type Wall mounted
18
temperature and humidity indicator
Make wall openings in concrete walls of lift
well and provided 1'' thick wooden Box in
19 the openings as per sizes given on the
drawings complete in all respects as per
satisfaction of Engineer/Consultant
Testing, balancing & commissioning of the
20 system. Report of Manufacture's
Represent Required)
Operation and maintenance of the system
21 (8:00) hr at least one month opeartion in
summer and one month in winter
Qty
Unit
660
1270
1
1
65
1
1
Rft
Rft
Rft
Rft
Rft
Rft
Rft
17
No.
1
Lot
12
No.
1
Lot
1
Lot
1
Lot
Rate
Amount
Sr
Description
After completion of commsissioning
prepare as build drawing for the record of
22
the client after obtaining approval of the
engineer/consultant
23 MDS Software Management Controller
Any other item which is essential to
complete the project and not given in this
24
BOQ may please be quoted and provide
details.
Qty
Unit
1
Lot
1
Lot
1
Lot
Rate
Amount
Total Cost in Rs
Note: a. Earnest money should be in form of Pay Order.
b. Following advance payments can be taken against scheduled Bank Gurantee :‐
i. On approval of technical submittals by the Consultant / Engineer
ii. On opening LC
iii. On production of bill of landing
iv. On delivery of equipment at site against theft insurrance