Catalogue & Price Ultrasound etc.

Published on February 2017 | Categories: Documents | Downloads: 48 | Comments: 0 | Views: 113
of 8
Download PDF   Embed   Report

Comments

Content

ISO 9001:2008

ISO 13485:2003

No. 225850/1

No. 8090055

Ultima SE Ultrasound Scanner
Clinical application:
abdominal cavity organs; obstetrics and gynecology; small organs; cerebrovascular system; cardiology; peripheric vessels; urology; pediatry; locomotor system.

Complete package of measurements and calculations in:
(2D) mode; mode; Dopplergraphy.

Modes:
1 B, M modes (black-and-white imaging) 1.1 Multifrequency formation of transmitted ultrasound beam; 1.2 Broadband formation of received ultrasound beam ± change of bandpass ratio that changes image parameters resolution ± penetration; 1.3 Tissue (second) harmonic; 1.4 Inverse harmonic; 1.5 Multi-angle compound imaging;

1.6 Intellectual architecture filter; 1.7 Multiparameter filter; 1.8 Color maps; 1.9 Ultrasound velocity variation; 1.10 Dynamic noise rejection filter; 1.11 Time-averaged maximum velocity; 2 F, F and TD modes (color mapping)

2.1 Parallel reception of up to 4 ultrasound beams forming in one probing for increase in color frame frequency; 2.2 Adaptive rejection wall filter, individual in each point of an ultrasound image for quality monitoring of low-velocity flow at moving tissue background; 2.3 Interframe filter with separate filtration of blood flow increase and decrease for temporal smoothing of color image; 2.4 Multiparameter filter of movement artefacts and aliasing, ensuring high sensitivity and image dynamism; 2.5 Adaptive threshold of grey-scale image (8 shades), forming the blood flow image within a vessel; 2.6 Multiparameter spatial filter for effective smoothing of flow image; 2.7 Semi-translucent image formation for simultaneous observation of tissues and blood flow velocity (or simultaneous observation of tissues and tissue velocity); 2.8 Multiparameter adaptive filter of pulsating blood flows for arterial vessels mapping. 3 PW (pulse-wave) and CW (continuous -wave) spectral Doppler modes 3.1 Pulse-wave (PW) and continuous-wave (CW) spectral Doppler modes; 3.2 RF with frequency of up to 25 kHz in PW mode; 3.3 Duplex and triplex scanning modes; 3.4 Saving raw data in cineloop that enables controlling most of processing parameters and repeated measurements in postprocessing; 3.5 Automatic routing of mean and maximum velocities; 3.6 Three types of Doppler measurements available - manual, semi-automatic and automatic; 3.7 Automatic computation of blood flow parameters (20 parameters) in real time and freeze mode.

Beam forming:
digital; multibeam parallel; multiangle*; multifrequency; broadband. * - ULTIMA SE EXPERT option

Configuration:
Configuration of ULTIMA series digital ultrasound diagnostic Doppler devices can be modified with further improvement to meet your requirements. The basic delivery set has a complete package of special measurement programs for all

investigation types. High density probes (192 elements) can be supplied.

Price: 36 700$
Warranty period - up to 24 months.

Madis X-ray Digital Mammographic System
Madis X-ray Digital Mammographic System is a modern tool for diagnosing breast diseases. It enables conducting all kinds of screening and diagnostic breast examinations provided in mammology. The system utilizes the digital technology of obtaining mammograms with image visualization on the monitor screen, paper and film media. NO NEED in photolaboratory, X-ray film, chemical agents The system consists of an X-ray stand device and workstations: X-ray technician¶s workstation and radiotherapist¶s diagnostic workstation. The system is powered from a singlephase AC network, 220 V, 50 Hz.

MADIS System provides:
Automatic or manual setting of exposure modes; Higher diagnostic value of pictures due to digital processing of X-ray image (brightness and contrast correction, filtering, zoom, determination of geometric parameters, positive and negative images, rotation etc.); Sending pictures over Internet (DICOM 3.0 format); Recording and archiving pictures and medical opinions on paper, floppy disks, CD/DVD, in computer memory; Examinations in diagnostic mode ² up to 20 patients per shift, in screening mode ² up to 40 patients per shift.

Performance Specification:
Operational field, mm Spatial resolution, line pairs/mm X-ray tube voltage, kV X-ray tube current, µA, max Exposure time, s Medium effective dose per picture, mSv Threshold contrast at surface exposure dose of 1mR, %, max Dynamic range Gray gradations on the monitor screen Archiving system Power consumption, W, max 240 180 8,0 28«40 200 0,1 to 9,0 0,1 2,0 100 256 On CD/DVD 500

MADIS Digital Mammographic System allows prompt and reliable diagnosing Warranty period - up to 18 months.

Price: 105 000$

ALMHP-01 Apparatus for Microwave Local Hyperthermy of Prostate

Apparatus for Microwave Local Hyperthermy of Prostate: ± quick relief from men's problems; ± urinologist¶s support; ± outpatient treatment of prostate adenoma during single session. ALMHP-01 apparatus is intended for: ± treatment of benign hyperplasia of prostate gland by the method of transurethral microwave therapy; ± treatment of chronic nonspecific prostatitis by the methods of transrectal microwave hyperthermy and transrectal vibratory massage. Treatment of benign hyperplasia (adenoma) of prostate gland by the minimum invasive method of transurethral microwave thermotherapy. Guarantee of success in treatment of prostatitis by the methods of transrectal microwave hyperthermia and transrectal vibratory massage. The treatment session is carried out automatically according to a program.

TREATMENT OF ADENOMA Transurethral Microwave Thermotherapy
The applied method of transurethral microwave thermotherapy enables conducting the treatment of prostate adenoma in an outpatient manner, during a single one-hour session. This method is indicated for treatment of patients denied of surgical treatment because of contraindications to anaesthesia, and patients willing to escape surgical interference in case of no positive effect from pharmacotherapy. The therapeutic effect is conditioned by adenomatous tissue modification after its heating to 45«55 ° . The action is applied locally by a microwave transducer inserted in the prostate gland area with an urethral catheter that cools urethra during the treatment session. The treatment session is conducted automatically according to a program. The physician can make corrections during the session. The current values of temperature and power are displayed on the screen.

The temperature is continuously monitored by an optical thermometric system. The temperature is monitored in the center of the prostate gland in the area of the maximum microwave action at the level of the urethral wall. To ensure the patient¶s safety, the rectal wall temperature is also monitored with three temperature sensors.

TREATMENT OF PROSTATITIS Transrectal Microwave Hyperthermia
At transrectal microwave hyperthermia, the rectum wall and the area of posterolateral surface of prostate gland is heated up to 41 to 43 ° .The effective heating layer depth is 1 to 2 cm. The local action is applied by a miniature transducer of microwave energy. A special temperature sensor placed in the maximum emission area provides for continuous monitoring of the heating temperature and its maintaining at a set level. A special rectal catheter provides for cooling of the rectum wall and protects it from overheating. The elevated, as compared to diathermy, temperature and the cyclic heating mode provide for higher therapeutic efficiency of the action. As a result of microwave heating, the arterial and capillary blood flow is enhanced, the number of actively functioning rectum wall and prostate gland capillars is increased, the lymph flow is enhanced. The conducted treatment course results in normalization of the gland blood circulation, the local tissue resistance is increased, and the inflammatory process is terminated. To increase the efficiency of the action, thermotherapy by means of heating the fluid circulating in this catheter is conducted simultaneously with vibratory massage. The fluid temperature can be adjusted within 37 to 42 ° . Unlike diathermy, darsonvalization, laser therapy, this method provides for stronger

action on the patient and his safety.

Transrectal Vibratory Massage
At transrectal vibration massage, the action, being a mechanical oscillation at a frequency of 1 to 5 Hz and amplitude of 1 to 5 mm is transferred through the rectal wall to the area of posterolateral surface of prostate gland and the urinary bladder fundus. Such action results in improvement of the drainage function of acinuses, the increase of the muscle tone of the prostate gland and rectum wall, enhancement of venous drainage, increase in the number of active capillars. Vibratory stimulant activates the adrenal pituitary-cortex system and increases the blood content of glucocorticoid hormones of cortisone and hydrocortisone type with pronounced antiinflammatory effect. The vibratory massage is done using a special rectal catheter.

Performance Specifications:
Operating frequency, Hz Output power adjusted with a step of 5 W in the range of, W Absolute error of temperature measurement, ° , max Vibration amplitude, mm Vibration frequency, Hz Overall dimensions, mm Mass, kg, max 50 Hz, 220 V mains power consumption, V , max 915 15 0...80 0,2 1...5 1...5 565 940 425 70 950

Delivery set:
basic device;

notebook (PC); re-usable rectal catheter for treatment of adenoma; set of single-use urethral catheters; set of re-usable rectal catheters for treatment of prostatitis. Single-use urethral catheter: working part diameter, mm

6,5

working part length, mm

500

Re-usable rectal catheters: working part diameter, mm working part length, mm 20 120

ALMHP-01 quick relief from men's problems, urinologists¶ support. .

Price: 84 000$ Prices: EXW Ukraine

Sponsor Documents

Or use your account on DocShare.tips

Hide

Forgot your password?

Or register your new account on DocShare.tips

Hide

Lost your password? Please enter your email address. You will receive a link to create a new password.

Back to log-in

Close