MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)

Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

1

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)

CONTENTS
COMPANY OVER VIEW CERTIFICATES AND APPROVALS MEFC PRODUCT OVER VIEW QUALITY ASSURANCE AND QUALITY CONTROL Page 4 Page 5-16 Page 17-18 Page 19-20

INDUSTRY / MEFC OPTICAL FIBERS
ITU G.652B SINGLE MODE DISPERSION UN-SHIFTED OPTICAL FIBER (STANDARD) ITU G.652C SINGLE MODE DISPERSION UN-SHIFTED OPTICAL FIBER (LOW WATER PEAK) ITU G.655 SINGLE MODE NON-ZERO DISPERSION SHIFTED FIBER (REDUCED SLOPE) ITU G.655 SINGLE MODE NON-ZERO DISPERSION SHIFTED FIBER (LARGE EFFECTIVE) 62.5/125 nm MULTI MODE OPTICAL FIBER Page 21 Page 22 Page 23 Page 24 Page 25

INDUSTRY / MEFC STANDARD CABLES OUTDOOR CABLES
DUCT NON-METALLIC O.F.CABLE DUCT METALLIC O.F. CABLE DIRECT BURIED NON-METALLIC O.F.CABLE DIRECT BURIED METALLIC O.F.CABLE STEEL TAPE ARMORED(SINGLE SHEATH) O.F.CABLE STEEL TAPE ARMORED(DOUBLE SHEATH) O.F.CABLE STEEL TAPE DOUBLE ARMORED O.F.CABLE STEEL TAPE ARMORED MONO TUBE O.F.CABLE STEEL WIRE ARMORED O.F.CABLE BRAIDED STEEL WIRE ARMORED O.F.CABLE LEAD SHEATH STEEL WIRE ARMORED O.F.CABLE HYBRID O.F.CABLE FIRE RESISTANCE O.F.CABLE ADSS AERIAL O.F. CABLE AERIAL FIG-8 O.F. CABLE (METTALLIC) AERIAL FIG-8 O.F. CABLE (ALL DIE ELECTRIC) Page 27 Page 28 Page 29 Page 30 Page 31 Page 32 Page 33 Page 34 Page 35 Page 36 Page 37 Page 38 Page 39 Page 40 Page 41 Page 42

Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

2

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
INDOOR CABLES
INDOOR SIMPLEX O.F.CABLE INDOOR ZIP CORD O.F.CABLE FLAT DUPLEX O.F. CABLE INDOOR BREAK OUT O.F.CABLE INDOOR BACK BONE O.F.CABLE INDOOR DISTRIBUTION O.F. CABLE Page 43 Page 44 Page 45 Page 46 Page 47 Page 48

INDOOR/OUTDOOR CABLES
INDOOR/OUTDOOR DRY O.F. CABLES INDOOR/OUTDOOR ARMORED O.F.CABLE Page 49 Page 50

CUSTOMER SPECIFIC OPTICAL FIBER CABLES
SAUDI ARAMCO STANDARD OPTICAL FIBER CABLES (VENDOR CODE : 10028837) SAUDI ELECTRIC COMPANY (SCECO-EAST) VENDOR CODE : M-3095 SAUDI TELECOM COMPANY (MAT-1601) SAUDI TELECOM COMPANY (MAT-1602) SAUDI ELECTRIC COMPANY (SCECO-CENTRAL) TACTICAL O.F. CABLE Page 51-52 Page 53 Page 54 Page 55 Page 56 Page 56

OPTICAL FIBER SPECIFICATIONS
SINGLE MODE FIBER SPECIFICATION (CABLES) MULTI MODE FIBER SPECIFICATION (CABLES) MEFC FIBER OPTIC SERVICES Page 57 Page 58 Page 59

RELATED TRADINGS - FIBER ACCESSORIES
CONNECTORS PATCH CORDS/PIG TAILS JOINT CLOSURES/TERMINATION BOXES GLOSSORY OF FIBER OPTIC TERMS Page 60 Page 61 Page 62 Page 63-69

Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

3

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
COMPANY OVERVIEW Middle East Fiber Optic Cable Mfg. Co. (MEFC), a Saudi American Joint Venture located in Riyadh Saudi Arabia. Founded in 1995 together with FiberCore and Royle Systems Group from USA, to manufacture a comprehensive state-of-the-art Fiber and Fiber Optic Cables, to serve Communication Service Providers, Data Communications, SCADA Systems, WANs, LANs, CCTV, Military Tactical Communications, Present 10 Gigabit Ethernet and FTTX Customers. In very short time, MEFC has achieved Excellence Quality Reputation and Market Share in the Gulf, Middle East and African countries. MEFC accredited with several certifications for its Product and Quality System from independent International testing agencies, such as British Standards Institute (BSI), Underwriter Laboratories (UL), Canadian Standards Association (CSA), Telcordia, TUV etc. Based on that MEFC has been approved by all major clients such as Saudi Aramco, Saudi Telecom Company, Electricity and Water Authorities, Kuwait Oil Company etc and all Major Oil and Gas Industries in the region. MEFC Cable specification meets all International Standards, MEFC was also able to have a strong presence and maintain a reputation in the international market by supplying Optical Fibers and Optical fiber cables to United States, Europe, Asia and African Countries. MEFC has capability to meet and exceed customer’s requirements and specifications. MEFC manufactures wide ranges of Optical fibers and Optical fiber cables. A brief summary of these products is: Optical Fibers: Single Mode Dispersion un-shifted, Non-Zero Dispersion shifted, Multi Mode. Optical Fiber Cables: Indoor – Simplex, Duplex, Breakout, Backbone and Distribution Outdoor – Under Ground Duct, Direct Buried, Armored Aerial - ADSS, Fig-8 Indoor / Outdoor – Fire Resistant both Non-Metallic and Metallic. With a clearly strategy, common mission to provide best quality products and emerge as a leader in the industry, MEFC poised for success and growth. Our Team is committed to deliver state and the art of technology with continuous improvement, on time delivery, best quality fiber and fiber optic cable products and after sales services.

CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

4

CERTIFICATE
Management system as per EN ISO 9001 : 2000
In accordance with TOV CERT procedures, it is hereby certified that

<r&~

ME Fe
Middle East Fiber Cable Manufacturing Co. Second Industrial Area, P.O.Box 733, Riyadh 11383, Kingdom of Saudi Arabia
Tel.:00966-1-265 0777, Fax: 00966-1-265 0203 E-Mail:[email protected], Website: www.mefcfcom

applies

a management system in line with the above standard for the following scope

Manufacture and Sales of Optical Fibers & Fiber Optic Cables

Certificate Registration No. 04 100 980279 Audit Report No. 3502 1327

Valid until 2010-06-30 Initial certification 1998

(. ~~~&~

TUV CERT Certification Body at TOV NORD CERT GmbH

Essen, 2007-09-19

This certification was conducted in accordance with the TOV CERT auditing and certification procedures and is subject to regular surveillance audits. TOV NORD CERT GmbH Langemarckstrasse 20
45141 Essen

-,

TGA-ZM-30-96-00

.
....................

www.tuev-nord-cert.com

"'-......

TUV:'')

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
CERTIFICATES / APPROVALS

CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

6

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
CERTIFICATES / APPROVALS

CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

7

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
CERTIFICATES / APPROVALS

CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

8

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
CERTIFICATES / APPROVALS

CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

9

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
CERTIFICATES / APPROVALS

CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

10

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
CERTIFICATES / APPROVALS

CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

11

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
CERTIFICATES / APPROVALS

CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

12

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
CERTIFICATES / APPROVALS

CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

13

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
CERTIFICATES / APPROVALS

CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

14

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
CERTIFICATES / APPROVALS

CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

15

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
CERTIFICATES / APPROVALS

CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

16

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
MEFC PRODUCT OVERVIEW

MEFC manufactures all latest technology optical fibers as per International Standards. Optical fibers are made from high quality silica glass and coated with dual layer acrylic material to give protection against micro bending, mechanical abrasion and temperature changes. MEFC Optical fibers are produced in highly clean environment and are ensured to maintain their pristine state through out manufacturing. Each fiber is proof tested to ensure that the fiber will function for a full life time of more than 30 years under residual stress conditions. With one of the best-equipped testing laboratories optical, geometrical, mechanical and environmental properties are measured for compliance to international standards, ITU, IEC, EIA/TIA etc. Tighter geometrical tolerance, high fiber curl and low PMD are the primary benefits of MEFC fiber which gives cost saving for the cable installers. Selection Of Right Type Of Fiber While choosing right type of Optical fiber for the networks, in general, the following factors shall be considered: • Present capacity requirements • Future demand and requirements • Active and Passive component costs While many factors have to be evaluated when selecting fibers for a given network, two key parameters – attenuation and dispersion are primarily important factors. Attenuation is the signal loss as travels through a fiber. Dispersion is the natural tendency of the different wavelengths in the light pulses to spread with distance traveled. Optical fibers are normally classified into two types, Single Mode and Multi Mode according to the no. of modes the fiber carries. 1.1.a – SINGLE MODE FIBER Single Mode Fibers are Further Classified into three categories by International Telecommunication Union based on the properties of Dispersion G.652 Dispersion Un-shifted Single Mode Fiber Also called as Standard Single Mode Fibers (9/125 nm) G.653 Dispersion shifted Fiber The dispersion at 1550nm is almost zero, these fibers are almost out dated due to the factors than they cannot be used in WDM and DWDM applications G.655 Non Zero Dispersion Shifted Fibers Advanced fiber technology for applications upto 40G.bits/sec. In both WDM and DWDM applications. STANDARD SINGLE MODE FIBER (9/125) (ITUG.652) ITU further divided the Single mode optical fibers are classified into A,B,C,D categories based on the applications attenuation and Dispersion and geometrical Parameters
CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

17

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
MEFC PRODUCT OVERVIEW ITU G.652.A

These Fiber are devised for transmission systems operating up to STM-16 ( 2.5 Gbits/Sec) , and are designed to operate at 1310 nm and 1550 nm Wave Length.
ITU G.652.B

These Fiber are devised for transmission systems operating up to STM-64 (10 Gbits/Sec), with tighter tolerance of PMD and Geometrical parameters and are designed to operate at 1310 nm and 1550 nm Wave Length.
ITU G.652.C

These Fiber are devised for transmission systems operating up to STM-64 (10 Gbits/Sec), allows transmission up to extended range 1260-1620 nm. The lower pear attenuation at 1380 nm allows these fibers can be utilized from 1260-1620 nm.
ITU G.652.D

These Fiber are devised for transmission systems operating up to STM-64 (10 Gbits/Sec), allows transmission up to extended range 1260-1620 nm. The lower pear attenuation at 1380 nm allows these fibers can be utilized from 1260-1620 nm, with tighter tolerance of PMD and Geometrical parameters of fibers. G.655- Non Zero Dispersion Shifted Single Mode Fibers These fibers are having minimum dispersion at 1550 nm for longer distance applications. Non zero dispersion shifter single mode fiber (NZDSF) is operated for WDM and DWDM systems which enables customer to construct high performance wired networks for voice, video and / or data transmission. 1.1.b – Multi Mode Fibers Multi Mode Fibers (MMF) provides a high performance in a wide range of application, suitable for short length networks and installed in the distribution portion of any telecommunications network. The have been classified on its Core diameter and Bandwidth requirements. Multi Mode Fibers are of two types even though ITU recognizes the with same standards, based on its core diameter. Multi Mode Fiber is differentiated as 50/125 and 62.5/125 nm

CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

18

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
QUALITY ASSURANCE AND QUALITY CONTROL As an ISO 9001: 2000 certified company, MEFC has been successfully implementing the quality management system requirements with a complete commitment to satisfy the Customer needs. Our experienced and highly skilled engineers/inspectors test the incoming raw materials, conduct in process inspection at every cable manufacturing stage, verify the compliance to the requirements after every process. Finished cables are tested as per national /international standards & customer specifications. Our cables meet the performance requirements of local utility Companies & national and international standards namely SCECO, ARAMCO, MAT (Saudi Telecom Standards), IEC, ITU-T, EIA/TIA, BS, BELL CORE, RUS-PE 90. Our Quality staff conducts tests to verify the performance and reliability of Optical fibers. These tests include Fiber strength, Attenuation Co-efficient, Attenuation uniformity, Mode field diameter, Cutoff Wavelength, Chromatic Dispersion, Polarization mode dispersion, Bandwidth, Numerical aperture, Cladding diameter, Concentricity error, Non-circularity and Coating diameter. The measurement in respect of above referred fiber parameters is carried out before the cabling process using advanced computer controlled test equipment, which are calibrated using international standard artifacts at regular intervals. These optical fibers are manufactured and tested in a dust free clean room environment. Type tests such as Macro bending, Temperature cycling are conducted periodically an optical fibers to the latest standards. Colored fibers are tested for MEK and compatibility with material, which they come in contact with when they are cabled. In order to verify the ability to withstand the extreme climate conditions, all the plastics components of the cable are tested for shrink back and cold bend test before being approved for processing.

CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

19

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
QUALITY ASSURANCE AND QUALITY CONTROL

After the stage wise inspection, routine testsattenuation co-efficient, Attenuation uniformity, water ingress test on filled cables, physical dimensions and surface quality, are carried out on the finished cables. In order to ensure the finished cables function satisfactorily for at least 30 to 40 years without degradation to the Optical transmission, type tests are conducted for every design periodically. Tensile loading, Fiber strain, Flexing, Repeated Bend, Impact, Crush, Torsion, Temperature cycling, Compound Flow tests are conducted using automated equipments to precisely apply the conditions laid down in international standards as well as customers specifications. The process and product quality characteristics are analyzed using statistical quality control techniques. X-bar and R charts, Normal Distribution analysis, Pareto Analysis, Percentile charts, Pcharts are widely used statistical techniques for monitoring of test equipment and product quality characteristics in MEFC. Our commitment towards delivering highest quality optical fiber cables is quality assurance to our customers that they can reap the benefits of peak performance from their fiber optic network.

OTDR TRACE OF OPTICAL FIBER

CHROMATIC DISPERSION

CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

20

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
ITU G.652B SINGLE MODE DISPERSION UN-SHIFTED OPTICAL FIBER (STANDARD) MEFC's OptiGlow-SMF optical fiber is a matched clad Dispersion unshifted single mode fiber A dual layer UV cured acrylate coating is applied over the pure glass cladding. This high quality coating protects the fiber from mechanical and environmental stresses and has excellent bend resistance characteristics. OptiGlow-SMF is optimized for use in 1310nm window by offering low dispersion and also can be used in 1550nm window. Telcordia certifies MEFC’s fiber for G.652 international standard. Also, OptiGlow-SMF meets IEC-60793-2 Telcordia GR-20-Core and TIA/EIA 492- Class IVa standards. OptiGlow-SMF has the distinction of having low PMD that makes high bit rate transmission possible. High curl values of OptiGlow are added advantage to the manufacturers of ribbon cables and installers as high curl values permit much faster splicing MEFC's optical fibers are manufactured using Vapor Phase Axial Deposition (VAD) process. VAD process is the most efficient process for controlling optical and geometrical properties of optical fibers.

CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

21

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
ITU G.652D SINGLE MODE DISPERSION UN-SHIFTED OPTICAL FIBER (LOW WATER PEAK)

MEFC's OptiGlow-LWP optical fiber is a matched clad Dispersion unshifted single mode fiber A dual layer UV cured acrylate coating is applied over the pure glass cladding. This high quality coating protects the fiber from mechanical and environmental stresses and has excellent bend resistance characteristics. Low attenuation of OptiGlow-LWP in broad range of wavelengths including water peak enables CWDM transmission for increased network capacity. Attenuation characteristics are stabilized against Hydrogen. It is designed for use in wavelengths between 1280 to 1625nm. It has superior attenuation performance throughout this band. OptiGlow-LWP is fully compatible with conventional Single Mode Fiber. Its low PMD and improved bending performance and high Curl advantage to the manufacturers of ribbon cables and installers as high curl values permit much faster splicing MEFC's optical fibers are manufactured using Vapor Phase Axial Deposition (VAD) process. VAD process is the most efficient process for controlling optical and geometrical properties of optical fibers.

D

CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

22

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
ITU G.655 SINGLE MODE NON-ZERO DISPERSION SHIFTED FIBER (REDUCED SLOPE)

MEFC's OptiShine-RS optical fiber is a matched Clad Non-Zero Dispersion shifted single mode optical fiber. A dual layer UV cured acrylate coating is applied over the pure glass cladding. This high quality coating protects the fiber from mechanical and environmental stresses and has excellent bend resistance characteristics. OptiShine-RS is optimized for use in 1550nm window by offering low dispersion to over come non-linear effects. Its Reduced slope makes it possible to keep the dispersion values low over a wide range of wavelengths there by reducing dispersion compensation. OptiShine-RS meets all the international standards, ITU-T G.655, IEC-60793-2 and EIA/TIA-492- Class IVd standards. OptiShine-RS has the distinction of having low PMD that makes high bit rate transmission possible. High curl values of OptiShine-RS are added advantage to the manufacturers of ribbon cables and installers as high curl values permit much faster splicing.

CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

23

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
ITU G.655 SINGLE MODE NON-ZERO DISPERSION SHIFTED FIBER (LARGE EFFECTIVE)

MEFC's OptiShine-LEA optical fiber is a matched Clad Non-Zero Dispersion shifted single mode Optical fiber. A dual layer UV cured acrylate coating is applied over the pure glass cladding. This high quality coating protects the fiber from mechanical and environmental stresses and has excellent bend resistance characteristics. OptiShine-LEA is optimized for use in 1550nm window by offering Large Effective Area to over come non-linear effects. OptiShine-LEA meets all the international standards, ITU-T G.655, IEC-60793-2 and EIA/TIA 492-Class IVd standards. OptiShine-LEA has the distinction of having low PMD that makes high bit rate transmission possible. High curl values of OptiShine-LEA are added advantage to the manufactures of ribbon cables and installers as high curl values permit much faster splicing.

CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

24

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
62.5/125 nm MULTI MODE OPTICAL FIBER

MEFC's OptiLan-62 is a Graded Index 62.5/125um Multi Mode Fiber. A dual layer UV cured acrylate coating is applied over the pure glass cladding. This high quality coating protects the fiber from mechanical and environmental stresses and has excellent bend resistance characteristics. OptiLan-62 meets ITU-T G.651 standard and fulfills the FDDI requirements for LAN cabling. Tight buffer process for indoor cables with MEFC's fiber is hassle free as the best results can be obtained with OptiLan-62.

CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

25

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
50/125 nm MULTI MODE OPTICAL FIBER

MEFC's OptiLan-50 is a Graded Index 50/125um Multi Mode Fiber. A dual layer UV cured acrylate coating is applied over the pure glass cladding. This high quality coating protects the fiber from mechanical and environmental stresses and has excellent bend resistance characteristics. OptiLan-50 meets ITU-T G.651 standard and fulfills the FDDI requirements for LAN cabling. Tight buffer process for indoor cables with MEFC's fiber is hassle free as the best results can be obtained with OptiLan-50.

CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

26

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
DUCT NON METALLIC O.F. CABLE

CABLE CONSTRUCTION
Loose Tubes filled with Gel - Stranded around Central Strength Member - Interstices filled with Gel - Core Wrap - Peripheral Strength Members - Polyethylene Outer Jacket

DESCRIPTION
The construction of the non-metallic cables begins with our proven loose tube design. The loose tube provides protection against environmental and mechanical forces. This smaller diameter cable is light weight and suitable enough for duct and conduit use

APPLICATIONS
Inter Office Trunking, Data, Video Transmission, Control /Alarm System - Light Weight and Flexible - Laying in Ducts and Concrete

FEATURES AND BENEFITS
Suitable for conduits and pipelines for long haul applications Supports all grades of single mode and multimode fibers It can be laid in vicinity of power cables No additional grounding is required, at vicinity of power lines and lighting risks Telemetry and SCADA links for oil & gas, electricity.

STANDARDS
Reference Standards: Industry Standard Fiber Specifications : Refer Page nos : 44-45 FIBER / TUBE COLOURS: AS PER IEC 60304 Aqua

PERFORMANCE CHARACTERISTICS
Storage Temperature : -40 C to +70 C Operating Temperature : -40 C to +70 C Blue, Orange, Green, Brown, Gray, White, Red, Black, Yellow, Violet, Pink, Max Pulling Tension
Fiber SMNZDS (G.655) ADUN4004 ADUN4008 ADUN4012 ADUN4024 ADUN4036 ADUN4048 ADUN4096 ADUN4144 ADUN4192 Fiber per Loose tube 4 4 4 4 6 8 12 24 24

Testing Procedures : IEC-60794-1 (or) EIA/TIA-455

: 2700 Newton
OUTER DIA (MM) 10.4 10.4 10.4 10.4 11.6 12.8 14.8 18.5 21.4 Min.Bending Radius(MM NO LOAD 104 104 104 104 116 128 148 277 321 UNDER LOAD 208 208 208 208 232 256 296 370 478 Net Weight

CABLE CODE
MM 50/125NM (G.651) ADUN6004 ADUN6008 ADUN6012 ADUN6024 ADUN6036 ADUN6048 ADUN6096 ADUN6144 ADUN6192 MM 50/125NM (G.651) ADUN5004 ADUN5008 ADUN5012 ADUN5024 ADUN5036 ADUN5048 ADUN5096 ADUN5144 ADUN5192 SM DISP. unshifted (G.652) ADUN1004 ADUN1008 ADUN1012 ADUN1024 ADUN1036 ADUN1048 ADUN1096 ADUN1144 ADUN1192

No.of active Loose tubes 1 2 3 6 6 6 8 6 8

count 4 8 12 24 36 48 96 144 192

(Kg/km) 96 97 98 100 113 145 212 269 387

CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

27

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
DUCT METALLIC O.F. CABLE

CABLE CONSTRUCTION
Loose Tubes filled with Gel - Stranded around Central Strength Member - Interstices filled with Gel - Core Wrap Peripheral Strength Members - Identification Tape - Aluminum Moisture Barrier Tape - Polyethylene Outer Jacket

DESCRIPTION
The construction of the metallic cables begins with our proven loose tube design. The loose tube provides protection against environmental and mechanical forces. This smaller diameter cable is light weight and suitable enough for duct and conduit use

APPLICATIONS
Inter Office Trunking, Data, Video Transmission, Control /Alarm System - Light Weight and Flexible - Laying in Ducts and Concrete

FEATURES AND BENEFITS
Suitable for conduits and pipelines for long haul applications Supports all grades of single mode and multimode fibers It can be laid in vicinity of power cables Telemetry and SCADA links for oil & gas, electricity.

STANDARDS
Reference Standards: Industry Standard Fiber Specifications : Refer Page nos : 44-45 FIBER / TUBE COLOURS: AS PER IEC 60304 Aqua

PERFORMANCE CHARACTERISTICS
Storage Temperature : -40 C to +70 C Operating Temperature : -40 C to +70 C Blue, Orange, Green, Brown, Gray, White, Red, Black, Yellow, Violet, Pink, Max Pulling Tension
Fiber SMNZDS (G.655) ADUN4004 –S ADUN4008 –S ADUN4012 –S ADUN4024 –S ADUN4036 –S ADUN4048 –S ADUN4096 –S Fiber per Loose tube 4 4 4 4 6 8 12

Testing Procedures : IEC-60794-1 (or) EIA/TIA-455

: 2700 Newton
No.of active Loose tubes 1 2 3 6 6 6 8 outer dia (MM) 11.2 11.2 11.2 11.2 12.0 13.7 15.5 Min.Bending Radius(MM NO LOAD 112 112 112 112 120 137 155 UNDE R LOAD 224 224 224 224 240 274 310 Net Weight (Kg/km) 103 104 105 108 127 152 186

CABLE CODE
MM 50/125NM (G.651) ADUN6004 –S ADUN6008 –S ADUN6012 –S ADUN6024 –S ADUN6036 –S ADUN6048 –S ADUN6096 –S MM 50/125NM (G.651) ADUN5004 –S ADUN5008 –S ADUN5012 –S ADUN5024 –S ADUN5036 –S ADUN5048 –S ADUN5096 –S SM DISP. unshifted (G.652) ADUN1004 –S ADUN1008 –S ADUN1012 –S ADUN1024 –S ADUN1036 –S ADUN1048 –S ADUN1096 –S

count 4 8 12 24 36 48 96

CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

28

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
DIRECT BURIED NON METALLIC O.F. CABLE

CABLE CONSTRUCTION
Loose Tubes filled with Gel - Stranded around Central Strength Member - Interstices filled with Gel - Core Wrap Polyethylene Inner sheath - Peripheral Strength Members - Water Blocking Material - Polyethylene Outer Jacket

DESCRIPTION
Double Jacket is an excellent choice for installation requiring the added mechanical and environmental protection of two durable polyethylene jackets. This Double Jacketed cable is directly buried in trenches.

APPLICATIONS
Junction Communication System, Subscriber Network System - Data, Video Transmission – Direct Buried Installation

FEATURES AND BENEFITS
* Supports all grades of single mode and multimode fibers * No Additional Grounding is required, at the vicinity of power lines and lighting risks. * Long Haul Telecommunication * Suitable for Lying in the trenches

STANDARDS
Reference Standards: Industry Standard Fiber Specifications : Refer Page nos : 44-45 FIBER / TUBE COLOURS: AS PER IEC 60304 Aqua

PERFORMANCE CHARACTERISTICS
Storage Temperature : -40 C to +70 C Operating Temperature : -40 C to +70 C Blue, Orange, Green, Brown, Gray, White, Red, Black, Yellow, Violet, Pink, Max Pulling Tension
Fiber Fiber per Loose tube 4 4 4 4 6 8 12 24 24

Testing Procedures : IEC-60794-1 (or) EIA/TIA-455

: 2700 Newton
No.of active Loose tubes 1 2 3 6 6 6 8 6 8 outer dia Min.Bending Radius(MM NO LOAD 132 132 132 132 144 156 176 301 345 UNDER LOAD 264 264 264 264 288 312 352 402 460 Net Weigh t Kg/km 129 131 131 133 159 188 249 333 414

CABLE CODE
MM 50/125NM (G.651) ADUN6004 ADUN6008 ADUN6012 ADUN6024 ADUN6036 ADUN6048 ADUN6096 ADUN6144 ADUN6192 MM 50/125NM (G.651) ADUN5004 ADUN5008 ADUN5012 ADUN5024 ADUN5036 ADUN5048 ADUN5096 ADUN5144 ADUN5192 SM DISP. unshifted (G.652) ADUN1004 ADUN1008 ADUN1012 ADUN1024 ADUN1036 ADUN1048 ADUN1096 ADUN1144 ADUN1192 SMNZDS (G.655) ADUN4004 ADUN4008 ADUN4012 ADUN4024 ADUN4036 ADUN4048 ADUN4096 ADUN4144 ADUN4192

count 4 8 12 24 36 48 96 144 192

(MM) 13.2 13.2 13.2 13.2 14.4 15.6 17.6 20.1 23.0

CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

29

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
DUCT BURIED METALLIC O.F. CABLE DIRECT

CABLE CONSTRUCTION
Loose Tubes filled with Gel - Stranded around Central Strength Member - Interstices filled with Gel - Core Wrap - Peripheral Strength Members - Identification Tape - Aluminum Moisture Barrier Tape - Polyethylene Inner sheath - Water Blocking Material - Polyethylene Outer Jacket

DESCRIPTION
Double Jacket is an excellent choice for installation requiring the added mechanical and environmental protection of two durable polyethylene jackets. This Double Jacketed cable is directly buried in trenches.

APPLICATIONS
Junction Communication System, Subscriber Network System - Data, Video Transmission – Direct Buried Installation

FEATURES AND BENEFITS
* Supports all grades of single mode and multimode fibers * Long Haul Telecommunication * Suitable for Lying in the trenches

STANDARDS
Reference Standards: Industry Standard Fiber Specifications : Refer Page nos : 44-45 FIBER / TUBE COLOURS: AS PER IEC 60304 Aqua

PERFORMANCE CHARACTERISTICS
Storage Temperature : -40 C to +70 C Operating Temperature : -40 C to +70 C Blue, Orange, Green, Brown, Gray, White, Red, Black, Yellow, Violet, Pink, Max Pulling Tension
Fiber SMNZDS (G.655) ADUN4004 ADUN4008 ADUN4012 ADUN4024 ADUN4036 ADUN4048 ADUN4096 Fiber per Loose tube 4 4 4 4 6 8 12

Testing Procedures : IEC-60794-1 (or) EIA/TIA-455

: 2700 Newton
No.of active Loose tubes 1 2 3 6 6 6 8 outer dia (MM) 13.6 13.6 13.6 13.6 14.8 16.0 18.0 Min.Bending Radius(MM NO LOAD 136 136 136 136 148 160 180 UNDE R LOAD 272 272 272 272 296 320 360 Net Weight (Kg/km) 148 149 150 153 171 216 260

CABLE CODE
MM 50/125NM (G.651) ADUN6004 ADUN6008 ADUN6012 ADUN6024 ADUN6036 ADUN6048 ADUN6096 MM 50/125NM (G.651) ADUN5004 ADUN5008 ADUN5012 ADUN5024 ADUN5036 ADUN5048 ADUN5096 SM DISP. unshifted (G.652) ADUN1004 ADUN1008 ADUN1012 ADUN1024 ADUN1036 ADUN1048 ADUN1096

count 4 8 12 24 36 48 96

CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

30

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
STEEL TAPE ARMOURED (SINGLE SHEATH) O.F. CABLE

CABLE CONSTRUCTION
Loose Tubes filled with Gel - Stranded around Central Strength Member - Interstices filled with Gel - Core Wrap - Peripheral Strength Members - Water Blocking Material - Corrugated Steel Tape Armour -Polyethylene Outer Jacket

DESCRIPTION
MEFC offers steel tape armored optical cable, which has been popular cabling solution for outside plant applications. Corrugated steel tape and a robust polyethylene outer jacket combine to deliver rugged durability and added rodent resistance.

APPLICATIONS
- Rodent Resistant- Direct Buried Installation- Data, Video, Voice, Transmission

FEATURES AND BENEFITS

Supports all grades of single mode and multimode fibers Offers excellent crush resistance STANDARDS
Reference Standards: Industry Standard Fiber Specifications : Refer Page nos : 44-45 FIBER / TUBE COLOURS: AS PER IEC 60304 Aqua

PERFORMANCE CHARACTERISTICS
Storage Temperature : -40 C to +70 C Operating Temperature : -40 C to +70 C Blue, Orange, Green, Brown, Gray, White, Red, Black, Yellow, Violet, Pink, Max Pulling Tension
Fiber SMNZDS (G.655) AAMM4004-S AAMM4008-S AAMM4024-S AAMM4012-S AAMM4036-S AAMM4048-S AAMM4096-S Fiber per Loose tube 4 4 4 4 6 8 12

Testing Procedures : IEC-60794-1 (or) EIA/TIA-455

: 2700 Newton
No.of active Loose tubes 1 2 3 6 6 6 8 outer dia (MM) 12.9 12.9 12.9 12.9 14.1 15.3 17.3 Min.Bending Radius(MM NO LOAD 193 193 193 193 211 229 259 UNDE R LOAD 258 258 258 258 282 306 346 Net Weight (Kg/km) 174 175 175 177 216 260 306

CABLE CODE
MM 50/125NM (G.651) AAMM6004 –S AAMM6008 –S AAMM6012 –S AAMM6024 –S AAMM6036 –S AAMM6048 –S AAMM6096 –S MM 50/125NM (G.651) AAMM5004 –S AAMM5008 –S AAMM5012 –S AAMM5024 –S AAMM5036 –S AAMM5048 –S AAMM5096 –S SM DISP. unshifted (G.652) AAMM1004-S AAMM1008-S AAMM1024-S AAMM1012-S AAMM1036-S AAMM1048-S AAMM1096-S

count 4 8 12 24 36 48 96

CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

31

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
STEEL TAPE ARMOURED (DOUBLE SHEATH) O.F. CABLE

CABLE CONSTRUCTION
Loose Tubes filled with Gel - Stranded around Central Strength Member - Interstices filled with Gel - Core Wrap Peripheral Strength Members - Water Blocking Material - Corrugated Steel Tape Armour -Polyethylene Outer Jacket

DESCRIPTION
MEFC offers steel tape armored optical cable, which has been popular cabling solution for outside plant applications. Corrugated steel tape and a robust polyethylene outer jacket combine to deliver rugged durability and added rodent resistance.

APPLICATIONS
- Rodent Resistant- Direct Buried Installation- Data, Video, Voice, Transmission

FEATURES AND BENEFITS

Supports all grades of single mode and multimode fibers Offers excellent crush resistance and projects from Rodent attacks STANDARDS
Reference Standards: Industry Standard Fiber Specifications : Refer Page nos : 44-45 FIBER / TUBE COLOURS: AS PER IEC 60304 Aqua

PERFORMANCE CHARACTERISTICS
Storage Temperature : -40 C to +70 C Operating Temperature : -40 C to +70 C Blue, Orange, Green, Brown, Gray, White, Red, Black, Yellow, Violet, Pink, Max Pulling Tension
Fiber per Loose tube 4 4 4 4 6 8 12

Testing Procedures : IEC-60794-1 (or) EIA/TIA-455

: 2700 Newton
No.of active Loose tubes 1 2 3 6 6 6 8 outer dia (MM) 14.0 14.0 14.0 14.0 15.1 16.3 18.3 Min.Bending Radius(MM NO LOAD 210 210 210 201 225 244 274 UNDE R LOAD 280 280 280 280 302 326 366 Net Weight (Kg/km) 197 198 199 205 228 266 332

CABLE CODE
MM 50/125NM (G.651) AAMM6004 –D AAMM6008 –D AAMM6012 –D AAMM6024 –D AAMM6036 –D AAMM6048 –D AAMM6096 –D MM 50/125NM (G.651) AAMM5004 –D AAMM5008 –D AAMM5012 –D AAMM5024 –D AAMM5036 –D AAMM5048 –D AAMM5096 –D SM DISP. unshifted (G.652) AAMM1004-D AAMM1008-D AAMM1024-D AAMM1012-D AAMM1036-D AAMM1048-D AAMM1096-D SMNZDS (G.655) AAMM4004-D AAMM4008-D AAMM4024-D AAMM4012-D AAMM4036-D AAMM4048-D AAMM4096-D

Fiber count

4 8 12 24 36 48 96

CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

32

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
STEEL TAPE DOUBLE ARMOURED O.F. CABLE

CABLE CONSTRUCTION
Loose Tubes filled with Gel - Stranded around Central Strength Member - Interstices filled with Gel - Core Wrap - Peripheral Strength Members - Polyethylene Inner Sheath - Corrugated Steel Tape Armour -Polyethylene Intermediate Sheath Corrugated Steel Tape Armour -Polyethylene Outer Jacket

DESCRIPTION
MEFC offers steel tape double armored optical cable, rugged and heavy-duty fiber which has been popular cabling solution for harsh environment . Corrugated steel tape and a robust double polyethylene outer jacket combine to deliver rugged durability and added rodent resistance.

APPLICATIONS
- Rodent Resistant- Heavy Duty - Data, Video, Voice, Transmission

FEATURES AND BENEFITS

Supports all grades of single mode and multimode fibers
Offers excellent crush resistance For Lying in Harsh Environment

STANDARDS
Reference Standards: Industry Standard Fiber Specifications : Refer Page nos : 44-45 FIBER / TUBE COLOURS: AS PER IEC 60304 Aqua

PERFORMANCE CHARACTERISTICS
Storage Temperature : -40 C to +70 C Operating Temperature : -40 C to +70 C Blue, Orange, Green, Brown, Gray, White, Red, Black, Yellow, Violet, Pink, Max Pulling Tension
Fiber SMNZDS (G.655) AAMM4004-T AAMM4008-T AAMM4024-T AAMM4012-T AAMM4036-T Fiber per Loose tube 4 4 4 4 6

Testing Procedures : IEC-60794-1 (or) EIA/TIA-455

: 2700 Newton
No.of active Loose tubes 1 2 3 6 6 outer dia (MM) Min.Bending Radius(MM NO LOAD UNDE R LOAD Net Weight (Kg/km)

CABLE CODE
MM 50/125NM (G.651) AAMM6004 –T AAMM6008 –T AAMM6012 –T AAMM6024 –T AAMM6036 –T MM 50/125NM (G.651) AAMM5004 –T AAMM5008 –T AAMM5012 –T AAMM5024 –T AAMM5036 –T SM DISP. unshifted (G.652) AAMM1004-T AAMM1008-T AAMM1024-T AAMM1012-T AAMM1036-T

count 4 8 12 24 36

17.7 17.7 17.7 17.7 18.9

265 265 265 265 283

354 354 354 354 378

341 342 343 345 390

CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

33

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
STEEL TAPE ARMOURED MONO TUBE O.F. CABLE

CABLE CONSTRUCTION
Fiber Bundles in Loose Tube filled with Gel - Peripheral Strength Members - Corrugated Steel Tape Armour Steel Wires embedded in Polyethylene Outer Jacket

DESCRIPTION
MEFC offers flexible and cost effective mono tube design for outdoor applications. Optical fibers are bundled in a single tube, and a required tensile strength is obtained without strength member using two supporting steel wires. For Specific applications MEFC can offer all dielectric mono tube design

APPLICATIONS
- Rodent Resistant - Data, Video, Voice, Transmission

FEATURES AND BENEFITS
Flexible and Light weight – Installation Friendly Cost Effective For Lying in Harsh Environment

STANDARDS
Reference Standards: Industry Standard Fiber Specifications : Refer Page nos : 44-45 FIBER / TUBE COLOURS: AS PER IEC 60304 Aqua

PERFORMANCE CHARACTERISTICS
Storage Temperature : -40 C to +70 C Operating Temperature : -40 C to +70 C Blue, Orange, Green, Brown, Gray, White, Red, Black, Yellow, Violet, Pink, Max Pulling Tension
Fiber SMNZDS (G.655) AAMM4004-M AAMM4008-M AAMM4024-M AAMM4012-M Fiber per Loose tube 4 4 4 4

Testing Procedures : IEC-60794-1 (or) EIA/TIA-455

: 2700 Newton
No.of active Loose tubes 1 2 3 6 outer dia (MM) Min.Bending Radius(MM NO LOAD UNDE R LOAD Net Weight (Kg/km)

CABLE CODE
MM 50/125NM (G.651) AAMM6004-M AAMM6008-M AAMM6012-M AAMM6024-M MM 50/125NM (G.651) AAMM5004 –M AAMM5008 –M AAMM5012 –M AAMM5024 –M SM DISP. unshifted (G.652) AAMM1004-M AAMM1008-M AAMM1024-M AAMM1012-M

count 4 8 12 24

11.6 11.6 11.6 11.6

174 174 174 174

232 232 232 232

170 170 171 172

CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

34

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
STEEL WIRE ARMOURED O.F. CABLE

CABLE CONSTRUCTION
Loose Tubes filled with Gel - Stranded around Central Strength Member - Interstices filled with Gel - Core Wrap Polyethylene Inner Sheath - Helically Stranded Steel Wires - Polyethylene Outer Jacket

DESCRIPTION
MEFC Steel wire armored cable offers applications for higher tensile requirements. The cable consists of two rugged polyethylene jackets to deliver the strength and rodent resistance, need for tough outside plant use.

APPLICATIONS
- Rodent Resistant – Direct Buried Installation Data, Video, Voice, Transmission

FEATURES AND BENEFITS
Supports all grades of single mode and multimode fibers Enhanced compressive strength and rodent resistance

STANDARDS
Reference Standards: Industry Standard Fiber Specifications : Refer Page nos : 44-45 FIBER / TUBE COLOURS: AS PER IEC 60304 Aqua

PERFORMANCE CHARACTERISTICS
Storage Temperature : -40 C to +70 C Operating Temperature : -40 C to +70 C Blue, Orange, Green, Brown, Gray, White, Red, Black, Yellow, Violet, Pink, Max Pulling Tension
Fiber per Loose tube 4 4 4 4 6 8

Testing Procedures : IEC-60794-1 (or) EIA/TIA-455

: 5000 Newton
No.of active Loose tubes 1 2 3 6 6 6 outer dia (MM) 14.4 14.4 14.4 14.4 15.6 16.8 Min.Bending Radius(MM NO LOAD 216 216 216 216 234 252 UNDE R LOAD 288 288 288 288 312 336 Net Weight (Kg/km) 355 356 357 358 443 506

CABLE CODE
MM 50/125NM (G.651) ASWM6004 ASWM6008 ASWM6012 ASWM6024 ASWM6036 ASWM6048 MM 50/125NM (G.651) ASWM5004 ASWM5008 ASWM5024 ASWM5012 ASEM5036 ASWM5048 SM DISP. unshifted (G.652) ASWM1004 ASWM1008 ASWM1024 ASWM1012 ASWM1036 ASWM1048 SMNZDS (G.655) ASWM4004 ASWM4008 ASWM4024 ASWM4012 ASWM4036 ASWM4048

Fiber count 4 8 12 24 36 48

CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

35

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
BRAIDED STEEL WIRE ARMOURED O.F. CABLE

CABLE CONSTRUCTION
Loose Tubes filled with Gel – Peripheral Strength Member - Polyethylene Inner Sheath - Steel Wire Braiding - Polyethylene Outer Jacket

DESCRIPTION
MEFC Steel wire armored fiber optic cable offers excellent resistance and flexibility with high tensile strength . These cables covered with tow rugged polyethylene jackets as well, to resist the rodent attacks.

APPLICATIONS
- Rodent Resistant – Direct Buried Installation Data, Video, Voice, Transmission

FEATURES AND BENEFITS
Greater Flexibility Enhanced compressive strength and rodent resistance Supports all graded of single mode and multi mode fibers

STANDARDS
Reference Standards: Industry Standard Fiber Specifications : Refer Page nos : 44-45 FIBER / TUBE COLOURS: AS PER IEC 60304 Aqua

PERFORMANCE CHARACTERISTICS
Storage Temperature : -40 C to +70 C Operating Temperature : -40 C to +70 C Blue, Orange, Green, Brown, Gray, White, Red, Black, Yellow, Violet, Pink, Max Pulling Tension
Fiber per Loose tube 4 4 4

Testing Procedures : IEC-60794-1 (or) EIA/TIA-455

: 2700 Newton
No. of active Loose tubes 1 1 1 outer dia (MM) 12.7 12.7 12.7 Min.Bending Radius(MM NO LOAD 190 190 190 UNDE R LOAD 254 254 254 Net Weight (Kg/km) 231 231 231

CABLE CODE
MM 50/125NM (G.651) ABWM6004 ABWM6008 ABWM6012 MM 50/125NM (G.651) ABWM5004 ABWM5008 ABWM5012 SM DISP. unshifted (G.652) AAMM1004 AAMM1008 AAMM1012 SMNZDS (G.655) ABWM4004 ABWM4008 ABWM4012

Fiber count 4 8 12

CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

36

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
LEAD SHEATH STEEL WIRE ARMOURED O.F. CABLE

CABLE CONSTRUCTION
Loose Tubes filled with Gel -Stranded around Central Strength Members - Interstices filled with Gel - Core Wrap - Flame Retardent PVC Inner Sheath - Lead Sheath - Second Inner Sheath - Helically stranded Steel Wire Armour -Flame Retardent PVC Outer Jacket

DESCRIPTION
MEFC offers Lead Sheathed Optical Fiber Cables which have an secondary sheath covered over an inner polyethylene sheath to protect the cable within from aromatic hydrides. These cables are covered by high tensile strength.

APPLICATIONS
- Petrochemical Plants - Junction Communication System, LANs - Direct Buried Installation

FEATURES AND BENEFITS
Installation in location where aromatic carbon hydrides are present .like near petrol stations. In the vicinity of pipe lines In oil refineries and similar locations.

STANDARDS
Reference Standards: Industry Standard Fiber Specifications : Refer Page nos : 44-45 FIBER / TUBE COLOURS: AS PER IEC 60304

PERFORMANCE CHARACTERISTICS
Storage Temperature : -40 C to +70 C Operating Temperature : -40 C to +70 C Blue, Orange, Green, Brown, Gray, White Max Pulling Tension
Fiber per Loose tube 4 4 4 4

Testing Procedures : IEC-60794-1 (or) EIA/TIA-455

: 2700 Newton
No. of active Loose tubes 1 2 3 6 outer dia (MM) 19.2 19.2 19.2 19.2 Min.Bending Radius(MM NO LOAD 288 288 288 288 UNDE R LOAD 384 384 384 384 Net Weight (Kg/km) 1017 1018 1018 1019

CABLE CODE
MM 50/125NM (G.651) ALAM6004 ALAM6008 ALAM6024 ALAM6012 MM 50/125NM (G.651) ALAM5004 ALAM5008 ALAM5024 ALAM5012 SM DISP. unshifted (G.652) ALAM1004 ALAM1008 ALAM1024 ALAM1012 SMNZDS (G.655) ALAM4004 ALAM4008 ALAM4024 ALAM4012

Fiber count 4 8 12 24

CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

37

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
HYBRID O.F. CABLE

CABLE CONSTRUCTION
Loose Tubes filled with Gel - Copper pair along with Loose Tubes Stranded around Steel Central Strength Member Interstices filled with Gel - Core Wrap - Peripheral Strength Members -Aluminum Moisture Barrier Tape- Polyethylene Outer Jacket

DESCRIPTION
MEFC offers a robust, highly reliable cable solution for a wide range of demanding outside plant applications, including direct buried and Rocky terrain. The Cable consists of Fibers with Insulated copper pair, insulated with Polyethylene Jacket

APPLICATIONS
- Enables alternate communication - Moisture Resistant - Junction Communication System, Subscriber Network System

FEATURES AND BENEFITS
Applicable for remote stations- where distribution of power cables are difficult Excellent Chemical Resistant outer cable jacket for Inside/Outside Plant Environment Composite cable can be utilized for both applications in power and data applications. Supports all grade of single mode and multi mode fibers.

STANDARDS
Reference Standards: Industry Standard Fiber Specifications : Refer Page nos : 44-45 FIBER / TUBE COLOURS: AS PER IEC 60304

PERFORMANCE CHARACTERISTICS
Storage Temperature : -40 C to +70 C Operating Temperature : -40 C to +70 C Blue, Orange, Green, Brown, Gray, White Max Pulling Tension
Fiber per Loose tube 4 4 4 4 6

Testing Procedures : IEC-60794-1 (or) EIA/TIA-455

: 2700 Newton
No. of active Loose tubes 1 2 3 6 6 outer dia (MM) 12.1 12.1 12.1 12.1 13.7 Min.Bending Radius(MM NO LOAD 121 121 121 121 137 UNDE R LOAD 242 242 242 242 374 Net Weight (Kg/km) 167 168 169 171 209

CABLE CODE
MM 50/125NM (G.651) AHBM6004 AHBM6008 AHBM6024 AHBM6012 AHBM6036 MM 50/125NM (G.651) AHBM5004 AHBM5008 AHBM5024 AHBM5012 AHBM5036 SM DISP. unshifted (G.652) AHBM1004 AHBM1008 AHBM1024 AHBM1012 AHBM1036 SMNZDS (G.655) AAMM4004 AAMM4008 AAMM4024 AAMM4012 AAMM4036

Fiber count 4 8 12 24 36

CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

38

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
FIRE RESISTANT O.F. CABLE

CABLE CONSTRUCTION
Loose Tubes filled with Gel and Wrapped with Mica Tape - Stranded around Steel Central Strength Member - Core Wrap with Water Blocking Mica Tape - Low Smoke Zero Halogen Inner Sheath -Steel Wire Braided - Mica Tape Low Smoke Zero Halogen Outer Jacket

DESCRIPTION
MEFC offers special type of Fire resistant cables for application in Oil and Gas Industries and other Petrochemical industries for higher resistance. This Core is wrapped with mica tape, which is having excellent characteristics of fire resistance. All MEFC fire resistant cable is approved by third part certifications.

APPLICATIONS
- Halogen Free, High Resistance to ignition - Low Heath of Combustion - Low Toxic and corrosive gas emission, Control, Alarm Systems, Data, Video Transmission

FEATURES AND BENEFITS
High temperature and Explosive Environments Extra heavy duty compressive strength Halogen free, less toxic and hazardous when exposed fire.

STANDARDS
Reference Standards: Industry Standard Fiber Specifications : Refer Page nos : 44-45 FIBER / TUBE COLOURS: AS PER IEC 60304

PERFORMANCE CHARACTERISTICS
Storage Temperature : -40 C to +70 C Operating Temperature : -40 C to +70 C Blue, Orange, Green, Brown, Gray, White Max Pulling Tension
Fiber per Loose tube 4 4 4 4 6

Testing Procedures : IEC-60794-1 (or) EIA/TIA-455

: 2700 Newton
No. of active Loose tubes 4 4 4 4 6 outer dia (MM) 16.1 16.1 16.1 16.1 17.3 Min.Bending Radius(MM NO LOAD 241 241 241 241 259 UNDE R LOAD 322 322 322 322 346 Net Weight (Kg/km) 355 357 359 362 406

CABLE CODE
MM 50/125NM (G.651) AFRM6004 AFRM6008 AFRM6024 AFRM6012 AFRM6036 MM 50/125NM (G.651) AFRM5004 AFRM5008 AFRM5024 AFRM5012 AFRM5036 SM DISP. unshifted (G.652) AFRM1004 AFRM1008 AFRM1024 AFRM1012 AFRM1036 SMNZDS (G.655) AFRM4004 AFRM4008 AFRM4024 AFRM4012 AFRM4036

Fiber count 4 8 12 24 36

CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

39

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
ADSS AERIAL O.F. CABLE

CABLE CONSTRUCTION
Loose Tubes filled with Gel - Stranded around Central Strength Member - Interstices filled with Gel - Core Wrap Polyethylene Inner Sheath - Peripheral Strength Members - Polyethylene Outer Jacket

DESCRIPTION
MEFC ADSS O.F. Cables are solution for high performance aerial environments including power transmission and distribution networks, All – Dielectric construction reduces installation costs, by avoiding the need for expensive cable shielding and grounding.

APPLICATIONS
- Aerial Installation - Lightening Protection - Junction Communication System, Subscriber Network System

FEATURES AND BENEFITS
Supports all grades of single and multimode fibers. Cable round Profile minimizes wind loading and tensile and ice loading.(Reducing cable sag and tensile force. All Dielectric loose tube design in immune to Electro Magnetic Interface.

STANDARDS
Reference Standards: Industry Standard Fiber Specifications : Refer Page nos : 44-45 FIBER / TUBE COLOURS: AS PER IEC 60304

PERFORMANCE CHARACTERISTICS
Storage Temperature : -40 C to +70 C Operating Temperature : -40 C to +70 C Blue, Orange, Green, Brown, Gray, White Max Pulling Tension
Fiber per Loose tube 4 4 4 4 6

Testing Procedures : IEC-60794-1 (or) EIA/TIA-455

: 5000 Newton
No. of active Loose tubes 1 2 3 6 6 outer dia (MM) 14.4 14.4 14.4 14.4 15.5 Min.Bending Radius(MM NO LOAD 144 144 144 144 155 UNDE R LOAD 288 288 288 288 310 Net Weight (Kg/km) 165 166 166 168 198

CABLE CODE
MM 50/125NM (G.651) AALN6004 AALN6008 AALN6024 AALN6012 AALN6036 MM 50/125NM (G.651) AALN5004 AALN5008 AALN5024 AALN5012 AALN5036 SM DISP. unshifted (G.652) AALN1004 AALN1008 AALN1024 AALN1012 AALN1036 SMNZDS (G.655) AALN4004 AALN4008 AALN4024 AALN4012 AALN4036

Fiber count 4 8 12 24 36

CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

40

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
AERIAL FIG – 8 O.F. CABLE (METTALLIC)

CABLE CONSTRUCTION
Loose Tubes filled with Gel - Stranded around Central Strength Member - Core Wrap - Polyethylene Inner Sheath - Water Blocking Material - Corrugated Steel Tape Armour- Messenger Wire embedded Polyethylene Outer Jacket

DESCRIPTION
MEFC Fig – 8 Cables are self-supporting cables designed for aerial installation. The Cable design provides easy and economical one- step Installation and Stable performance over a wide temperature range. The Whole tensile load is borne by steel messenger wire.

APPLICATIONS
- Aerial Installation - High Mechanical Strength - Data, Voice, Video Transmission

FEATURES AND BENEFITS
Small Diameter and Light Weight Double Jacket single armor construction provides additional crush and mechanical Protection. Compatible for any telecommunication grade optical fiber.

STANDARDS
Reference Standards: Industry Standard Fiber Specifications : Refer Page nos : 44-45 FIBER / TUBE COLOURS: AS PER IEC 60304

PERFORMANCE CHARACTERISTICS
Storage Temperature : -40 C to +70 C Operating Temperature : -40 C to +70 C Blue, Orange, Green, Brown, Gray, White Max Pulling Tension
Fiber per Loose tube

Testing Procedures : IEC-60794-1 (or) EIA/TIA-455

: 2700 Newton
Min.Bending Radius(MM NO LOAD UNDE R LOAD Net Weight (Kg/km)

CABLE CODE
MM 50/125NM (G.651) MM 50/125NM (G.651) SM DISP. unshifted (G.652) SMNZDS (G.655)

Fiber count 4 8 12 24 36

No. of active Loose tubes

outer dia (MM)

AALM6004 AALM6008 AALM6024 AALM6012 AALM6036

AALM5004 AALM5008 AALM5024 AALM5012 AALM5036

AALM1004 AALM1008 AALM1024 AALM1012 AALM1036

AALM4004 AALM4008 AALM4024 AALM4012 AALM4036

2 2 2 4 6

2 4 6 6 6

23.5x13.2 23.5x13.2 23.5x13.2 24.7x14.2 25.9x15.6

132 132 132 142 156

264 264 264 284 312

323 324 326 352 392

CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

41

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
AERIAL FIG – 8 O.F. CABLE (ALL DIELECTRIC)

CABLE CONSTRUCTION
Loose Tubes filled with Gel - Stranded around Central Strength Member - Core Wrap - Polyethylene Inner Sheath - Water Blocking Material - Messenger Wire embedded Polyethylene Outer Jacket

DESCRIPTION
MEFC Fig – 8 Cables are self-supporting cables designed for aerial installation. The Cable design provides easy and economical one- step Installation and Stable performance over a wide temperature range. The Whole tensile load is borne by FRP Messenger wire.

APPLICATIONS
- Aerial Installation - High Mechanical Strength - Data, Voice, Video Transmission

FEATURES AND BENEFITS
Small Diameter and Light Weight Double Jacket single armor construction provides additional crush and mechanical Protection. Compatible for any telecommunication grade optical fiber. Fiber Reinforced Plastic as a messenger wire, All Dielectric Cable Immune to Electro Magnetic Interface.

STANDARDS
Reference Standards: Industry Standard Fiber Specifications : Refer Page nos : 44-45 FIBER / TUBE COLOURS: AS PER IEC 60304

PERFORMANCE CHARACTERISTICS
Storage Temperature : -40 C to +70 C Operating Temperature : -40 C to +70 C Blue, Orange, Green, Brown, Gray, White Max Pulling Tension
Fiber per Loose tube

Testing Procedures : IEC-60794-1 (or) EIA/TIA-455

: 2700 Newton
No. of active Loose tubes outer dia (MM) Min.Bending Radius(MM NO LOAD UNDE R LOAD Net Weight (Kg/km)

CABLE CODE
MM 50/125NM (G.651) MM 50/125NM (G.651) SM DISP. unshifted (G.652) SMNZDS (G.655)

Fiber count

AALM6004 AALM6008 AALM6024 AALM6012 AALM6036

AALM5004 AALM5008 AALM5024 AALM5012 AALM5036

AALM1004 AALM1008 AALM1024 AALM1012 AALM1036

AALM4004 AALM4008 AALM4024 AALM4012 AALM4036

4 8 12 24 36

2 2 2 4 6

2 4 6 6 6

23.5x 13.2 23.5x 13.2 23.5x 13.2 24.7x 14.2 25.9x 15.6

132 132 132 142 156

264 264 264 284 312

323 324 326 352 392

CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

42

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
INDOOR SIMPLEX O.F. CABLE

CABLE CONSTRUCTION
900 um Tight Buffer - Peripheral Strength Members - Riser / Plenum Orange Color Jacket.

DESCRIPTION
MEFC Simplex cables for indoor applications are flexible enough to handle easily in any interconnect or cross connect applications in the central office, equipment room. The main construction of these cables consists of flexible tight-buffered material, extended over the fibers surrounded with aramid yarns for additional protection and strength.

APPLICATIONS
- Pigtail and Patch cords - Factory Automation, Inter office - Aircraft and marine systems

FEATURES AND BENEFITS
Used for Pigtails/Patch Cords in central offices, data centers etc. Cab be directly terminated to any type of connectors. Easier to strip and allows longer lengths of buffer to be removed in single press Both raiser and plenum grades are available

STANDARDS
Reference Standards: Industry Standard Fiber Specifications : Refer Page nos : 44-45 FIBER / TUBE COLOURS: AS PER IEC 60304

PERFORMANCE CHARACTERISTICS
Storage Temperature : -10 C to +70 C Operating Temperature : -10 C to +70 C Natural Color Max Pulling Tension
Fiber per Loose tube

Testing Procedures : IEC-60794-1 (or) EIA/TIA-455

: 500 Newton
No. of active Loose tubes outer dia (MM) Min.Bending Radius(MM NO LOAD UNDE R LOAD Net Weight (Kg/km)

CABLE CODE
MM 50/125NM (G.651) MM 50/125NM (G.651) SM DISP. unshifted (G.652) SMNZDS (G.655)

Fiber count 1

BSXR6001

BSXR5001

BSXR1001

BSXR4001

1

1

3.0

45

60

9.6

CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

43

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
INDOOR ZIP CORD O.F. CABLE

CABLE CONSTRUCTION
900 um Tight Buffer - Peripheral Strength Members - Riser / Plenum Orange Color Jacket.

DESCRIPTION
MEFC zip cord indoor type cables are designed for two way communication, provides excellent transmission performance, flexibility and connectivity for optical network systems in a variety of installation environments. The tight buffers are color coded for easy Identification during termination.

APPLICATIONS
- Pigtail and Patch cords - Factory Automation, Inter office - Aircraft and marine systems

FEATURES AND BENEFITS
Eases installation and space constrained area. Ensures lower total installation costs. Used in LAN, SAN equipment rooms. Small size lightweight and versatile installation capability.

STANDARDS
Reference Standards: Industry Standard Fiber Specifications : Refer Page nos : 44-45 FIBER / TUBE COLOURS: AS PER IEC 60304

PERFORMANCE CHARACTERISTICS
Storage Temperature : -10 C to +70 C Operating Temperature : -10 C to +70 C Natural Color Max Pulling Tension
Fiber per Loose tube

Testing Procedures : IEC-60794-1 (or) EIA/TIA-455

: 500 Newton
No. of active Loose tubes Min.Bending Radius(MM NO LOAD UNDE R LOAD Net Weight (Kg/km)

CABLE CODE
MM 50/125NM (G.651) MM 50/125NM (G.651) SM DISP. unshifted (G.652) SMNZDS (G.655)

Fiber count 21

outer dia (MM) 6.1x3.0

BZCR6002

BZCR5002

BZCR1002

BZCR4002

1

2

61

92

17

CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

44

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
FLAT DUPLEX O.F. CABLE

CABLE CONSTRUCTION
900 um Tight Buffer - Peripheral Strength Members - Riser / Plenum Orange Color Jacket – Two Simplex Cords - Riser / Plenum common jacket over two simplex cords

DESCRIPTION
MEFC Flat Duplex cables are designed for two-way communication, provides excellent transmission performance, flexibility and connectivity for optical network systems in a variety of installation environments. The tight buffers are color coded for easy Identification during termination.

APPLICATIONS
- Pigtail and Patch cords - Factory Automation, Inter office – Under Carpet

FEATURES AND BENEFITS
Eases installation and space constrained area. Ensures lower total installation costs. Used in LAN, SAN equipment rooms. Small size lightweight and versatile installation capability. Offers All grades of multi mode and single mode fibers

STANDARDS
Reference Standards: Industry Standard Fiber Specifications : Refer Page nos : 44-45 FIBER / TUBE COLOURS: AS PER IEC 60304

PERFORMANCE CHARACTERISTICS
Storage Temperature : -10 C to +70 C Operating Temperature : -10 C to +70 C Natural Color Max Pulling Tension
Fiber per Loose tube

Testing Procedures : IEC-60794-1 (or) EIA/TIA-455

: 500 Newton
No. of active Loose tubes outer dia (MM)
6.6x3.8

CABLE CODE
MM 50/125NM (G.651) MM 50/125NM (G.651) SM DISP. unshifted (G.652) SMNZDS (G.655)

Fiber count 2

Min.Bending Radius(MM NO LOAD UNDE R LOAD

Net Weight (Kg/km)

BFDR6002

BFDR5002

BFDR1002

BFDR4002

1

2

61

99

26

CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

45

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
INDOOR BREAKOUT O.F. CABLE

CABLE CONSTRUCTION
Sub Units with Tight Buffers and Peripheral Strength Members - Stranded around Central Strength Member - Core Wrap – Orange Color Jacket

DESCRIPTION
MEFC Indoor Breakout Cable provides excellent transmission performance, flexibility and connectivity for optical network systems in a variety of installation environments.

APPLICATIONS
- LAN, CCTV -Direct Termination of Fibers -Plenum and Riser

FEATURES AND BENEFITS
Eases installation and space constrained area. Ensures lower total installation costs. LSZH – Low smoke halogen out jacket protects fibers from flame Small size lightweight and versatile installation capability. Reduce smoke emissions and flame spreading. Both raiser and plenum grades are available

STANDARDS
Reference Standards: Industry Standard Fiber Specifications : Refer Page nos : 44-45

PERFORMANCE CHARACTERISTICS
Storage Temperature : -10 C to +70 C Operating Temperature : -10 C to +70 C

FIBER / TUBE COLOURS: AS PER IEC 60304 Blue, Orange, Green, Brown, Gray, White, Red, Black, Yellow, Violet, Pink,

Aqua
Testing Procedures : IEC-60794-1 (or) EIA/TIA-455 Max Pulling Tension
Fiber per Loose tube 6 6 8 12

: 1000 Newton
No. of active Loose tubes 4 6 6 6 outer dia (MM) 15.1 18.1 21.1 22.0 Min.Bending Radius(MM NO LOAD 226 271 316 330 UNDE R LOAD 302 362 422 440 Net Weight (Kg/km) 191 282 325 400

CABLE CODE
MM 50/125NM (G.651) BBOR6024 BBOR6036 BBOR6048 BBOR6072 MM 50/125NM (G.651) BBOR5024 BBOR5036 BBOR5048 BBOR5072 SM DISP. unshifted (G.652) BBOR1024 BBOR1036 BBOR1048 BBOR1072 SMNZDS (G.655) BBOR4024 BBOR4036 BBOR4048 BBOR4072

Fiber count 24 36 48 72

CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

46

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
INDOOR BACKBONE O.F. CABLE

CABLE CONSTRUCTION
Sub Units with Tight Buffers and Peripheral Strength Members - Stranded around Central Strength Member - Core Wrap – Orange Color Jacket

DESCRIPTION
MEFC Indoor backbone Cable provides excellent transmission performance, flexibility and connectivity for optical network systems in a variety of installation environments.

APPLICATIONS
- Intrabuilding Local Area Network - Data, Voice, Video Transmission – CATV

FEATURES AND BENEFITS
Eases installation and space constrained area. Ensures lower total installation costs. LSZH – Low smoke halogen out jacket protects fibers from flame Small size lightweight and versatile installation capability. Reduce smoke emissions and flame spreading. Both raiser and plenum grades are available

STANDARDS
Reference Standards: Industry Standard Fiber Specifications : Refer Page nos : 44-45

PERFORMANCE CHARACTERISTICS
Storage Temperature : -10 C to +70 C Operating Temperature : -10 C to +70 C

FIBER / TUBE COLOURS: AS PER IEC 60304 Blue, Orange, Green, Brown, Gray, White, Red, Black, Yellow, Violet, Pink,

Aqua
Testing Procedures : IEC-60794-1 (or) EIA/TIA-455 Max Pulling Tension
Fiber per Loose tube 4 4 4 4 6 8

: 1000 Newton
No. of active Loose tubes 4 4 4 4 6 8 outer dia (MM) 11.4 11.4 11.4 11.4 11.4 21.7 Min.Bending Radius(MM NO LOAD 171 171 171 171 171 325 UNDE R LOAD 228 228 228 228 228 434 Net Weight (Kg/km) 119 120 122 123 124 396

CABLE CODE
MM 50/125NM (G.651) BBBN6002 BBBN6004 BBBN6010 BBBN6008 BBBN6012 BBBN6072 MM 50/125NM (G.651) BBBN5002 BBBN5004 BBBN5010 BBBN5008 BBBN5012 BBBN5072 SM DISP. unshifted (G.652) BBBN1002 BBBN1004 BBBN1010 BBBN1008 BBBN1012 BBBN1072 SMNZDS (G.655) BBBN4002 BBBN4004 BBBN4010 BBBN4008 BBBN4012 BBBN4072

Fiber count 4 8 12 24 36 48

CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

47

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
INDOOR DISTRIBUTION O.F. CABLE

CABLE CONSTRUCTION
Tight Buffers surrounded by Peripheral Strength Members - Orange Color Jacket

DESCRIPTION
MEFC Indoor distribution cables dry core, which is available both plenum and rise grade, The peripheral strength members mostly aramid yarns provide excellent tensile load for cable.

APPLICATIONS
- LAN, CCTV – Direct termination of fibers - Plenum and Riser

FEATURES AND BENEFITS
Flexible light weight. Eases installation and space constrained areas. Ensures lower total installation costs. Used in LAN, SAN equipment rooms. Offers all grades of multi mode and single mode fibers.

STANDARDS
Reference Standards: Industry Standard Fiber Specifications : Refer Page nos : 44-45

PERFORMANCE CHARACTERISTICS
Storage Temperature : -10 C to +70 C Operating Temperature : -10 C to +70 C

FIBER / TUBE COLOURS: AS PER IEC 60304 Blue, Orange, Green, Brown, Gray, White, Red, Black, Yellow, Violet, Pink,

Aqua
Testing Procedures : IEC-60794-1 (or) EIA/TIA-455 Max Pulling Tension
Fiber per Loose tube 2 4 6 8 10 12

: 500 Newton
Min.Bending Radius(MM NO LOAD 47 91 105 105 135 135 UNDE R LOAD 62 122 140 140 180 180 Net Weight (Kg/km) 8.3 35 42 44 57 59

CABLE CODE
MM 50/125NM (G.651) BDBN6002 BDBN6004 BDBN6010 BDBN6008 BDBN6012 BDBN6072 MM 50/125NM (G.651) BDBN5002 BDBN5004 BDBN5010 BDBN5008 BDBN5012 BDBN5072 SM DISP. unshifted (G.652) BDBN1002 BDBN1004 BDBN1010 BDBN1008 BDBN1012 BDBN1072 SMNZDS (G.655) BDBN4002 BDBN4004 BDBN4010 BDBN4008 BDBN4012 BDBN4072

Fiber count 2 4 6 8 10 12

outer dia (MM) 3.1 6.1 7.0 7.0 9.0 9.0

CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

48

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
INDOOR OUTDOOR DRY O.F. CABLE (TIGHT BUFFER TYPE)

CABLE CONSTRUCTION
Sub Units with Tight Buffers and Water Blocking Yarns - Stranded around Central Strength Member - Core Wrap – Peripheral Strength Members – UV Resistant LSZH Outer Jacket

DESCRIPTION
MEFC Indoor /Outdoor cable is the most suitable with Indoor and Outdoor applications. In campus type environment with many building-to-building, MEFC cables can be used in conduits and connected to inside building with any splice termination.

APPLICATIONS
- Inter office trunking – Data, Voice, Video Transmission – Control Alarm System

FEATURES AND BENEFITS
Avoids splicing and connecting between Indoor and Outdoor Multi Applications.. Light weight and flexible. Both raiser and plenum grades are available Offers all grades of multi mode and single mode fibers.

STANDARDS
Reference Standards: Industry Standard Fiber Specifications : Refer Page nos : 44-45

PERFORMANCE CHARACTERISTICS
Storage Temperature: -10 C to +70 C Operating Temperature: -10 C to +70 C

FIBER / TUBE COLOURS: AS PER IEC 60304 Tight Buffer Colors: Blue, Orange, SUB UNIT COLORS Green, Brown, Gray, White Testing Procedures : IEC-60794-1 (or) EIA/TIA-455 Max Pulling Tension: 1000 Newton
Tight Buffer Per Sub Unit 2 2 2 No.Of Active Sub Units 2 4 6 Min.Bending Radius(MM NO LOAD 222 222 222 UNDE R LOAD 296 296 296 Net Weight (Kg/km) 177 178 179

CABLE CODE
MM 50/125NM (G.651) IDUN6004-Y IDUN6008-Y IDUN6012-Y MM 50/125NM (G.651) IDUN5004-Y IDUN5008-Y IDUN5012-Y SM DISP. unshifted (G.652) IDUN1004-Y IDUN1008-Y IDUN1012-Y SMNZDS (G.655) IDUN4004-Y IDUN4008-Y IDUN4012-Y

Fiber count 4 8 12

Outer Dia (MM) 14.8 14.8 14.8

CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

49

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
INDOOR OUTDOOR ARMORED O.F. CABLE

CABLE CONSTRUCTION
Tight Buffered Simplex Cords - Stranded around Central Strength Member - Core Wrap –Flame Retardant Inner Sheath – Corrugated Steel Tape – Flame Retardant Outer Jacket

DESCRIPTION
MEFC Indoor /Outdoor armored cable offers excellent tensile strength for both Indoor and Outdoor applications. Suitable for building-to-building short distance inter connected applications. MEFC Indoor /Outdoor armored cable offers excellent resistance for rodent attacks.

APPLICATIONS
- Rorent Resistant – Indoor and Outdoor Installation – Direct Buried Insatallation

FEATURES AND BENEFITS
Avoids splicing and connecting between Indoor and Outdoor Multi Applications.. Light weight and flexible. Both raiser and plenum grades are available Supports all grades of multi mode and single mode fibers. Rodent resistant

STANDARDS
Reference Standards: Industry Standard Fiber Specifications : Refer Page nos : 44-45

PERFORMANCE CHARACTERISTICS
Storage Temperature: -10 C to +70 C Operating Temperature: -10 C to +70 C

FIBER / TUBE COLOURS: AS PER IEC 60304 Tight Buffer Colors: Blue, Orange, SUB UNIT COLORS Green, Brown, Gray, White Testing Procedures : IEC-60794-1 (or) EIA/TIA-455 Max Pulling Tension: 2000 Newton
Tight Buffer Per Sub Unit 1 2 2 No.Of Active Sub Units 1 4 6 Min.Bending Radius(MM NO LOAD 261 261 261 UNDE R LOAD 348 348 348 Net Weight (Kg/km) 274 275 277

CABLE CODE
MM 50/125NM (G.651) IAMM6004 IAMM6008 IAMM6012 MM 50/125NM (G.651) IAMM5004 IAMM5008 IAMM5012 SM DISP. unshifted (G.652) IAMM1004 IAMM1008 IAMM1012 SMNZDS (G.655) IAMM4004 IAMM4008 IAMM4012

Fiber count 4 8 12

Outer Dia (MM) 17.4 17.4 17.4

CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

50

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
DUCT NON METALLIC O.F. CABLE –SAUDI ARAMCO

STANDARDS
Reference Standards: 18-SAMSS-625 (Saudi Aramco) Fiber Specifications : Refer Page nos : 44-45 Testing Procedures : IEC-60794-1 (or) EIA/TIA-455

PERFORMANCE CHARACTERISTICS
Storage Temperature: -40 C to +70 C Operating Temperature: -40 C to +70 C Max Pulling Tension: 2700 Newton

ORDERING INFORMATION

A
Outdoor Duct

DU

N
Non Metallic * Fiber Type * Fiber Count

A
Aramco

DUCT BURIED NON METALLIC O.F. CABLE –SAUDI ARAMCO

STANDARDS
Reference Standards: 18-SAMSS-625 (Saudi Aramco) Fiber Specifications : Refer Page nos : 44-45 Testing Procedures : IEC-60794-1 (or) EIA/TIA-455

PERFORMANCE CHARACTERISTICS
Storage Temperature: Max Pulling Tension: -40 C to +70 C 2700 Newton Operating Temperature: -40 C to +70 C

ORDERING INFORMATION

A
Outdoor Direct Buried

DB

N
Non Metallic * Fiber Type * Fiber Count

A
Aramco

* Fiber Type 1. Single Mode Dispersion Unshifted Fiber (Matched Clad) 2. Single Mode Dispersion Unshifted Fiber (Depressed Clad) 3. Single Mode Dispersion Shifted Fiber 4. Single Mode NonZero Dispersion shifted Fiber 5. MM 62.5/125nm 6. MM 50/125 nm
CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

51

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
STEEL TABLE ARMORED DOUBLE SHEATH O.F. CABLE –SAUDI ARAMCO

STANDARDS
Reference Standards: 18-SAMSS-625 (Saudi Aramco) Fiber Specifications : Refer Page nos : 44-45 Testing Procedures : IEC-60794-1 (or) EIA/TIA-455

PERFORMANCE CHARACTERISTICS
Storage Temperature: -40 C to +70 C Operating Temperature: -40 C to +70 C Max Pulling Tension: 2700 Newton

ORDERING INFORMATION A
Outdoor Armored

AM

M
Metallic * Fiber Type * Fiber Count

A
Aramco

INDOOR BACKBONE O.F. CABLE –SAUDI ARAMCO

STANDARDS
Reference Standards: 18-SAMSS-625 (Saudi Aramco) Fiber Specifications : Refer Page nos : 44-45 Testing Procedures : IEC-60794-1 (or) EIA/TIA-455

PERFORMANCE CHARACTERISTICS
Storage Temperature: -40 C to +70 C Operating Temperature: -40 C to +70 C Max Pulling Tension: 1000 Newton

ORDERING INFORMATION B
Indoor Backbone

BB

P
* Fiber Type * Fiber Count

A
Aramco

* Fiber Type 1. Single Mode Dispersion Unshifted Fiber (Matched Clad) 2. Single Mode Dispersion Unshifted Fiber (Depressed Clad) 3. Single Mode Dispersion Shifted Fiber 4. Single Mode NonZero Dispersion shifted Fiber 5. MM 62.5/125nm 6. MM 50/125 nm

CONTENTS CONTENTS

Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

52

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
DUCT NON METALLIC O.F. CABLE –SCECO EAST

STANDARDS
Reference Standards: 11-SMSS-625 (SCECO EAST) Fiber Specifications : Refer Page nos : 44-45 Testing Procedures : IEC-60794-1 (or) EIA/TIA-455

PERFORMANCE CHARACTERISTICS
Storage Temperature: -40 C to +70 C Operating Temperature: -40 C to +70 C Max Pulling Tension: 2700 Newton

ORDERING INFORMATION

A
Outdoor Duct

D

N
Non-Metallic * Fiber Type * Fiber Count

E
SCECO-EAST

DIRECT BURIED NON METALLIC O.F. CABLE –SCECO EAST

STANDARDS
Reference Standards: 18-SAMSS-625 (Saudi Aramco) Fiber Specifications : Refer Page nos : 44-45 Testing Procedures : IEC-60794-1 (or) EIA/TIA-455

PERFORMANCE CHARACTERISTICS
Storage Temperature: -40 C to +70 C Operating Temperature: -40 C to +70 C Max Pulling Tension: 1000 Newton

ORDERING INFORMATION

A
Outdoor Direct Buried

DB

N
Non-Metallic * Fiber Type * Fiber Count

A
SCECO-EAST

* Fiber Type 1. Single Mode Dispersion Unshifted Fiber (Matched Clad) 2. Single Mode Dispersion Unshifted Fiber (Depressed Clad) 3. Single Mode Dispersion Shifted Fiber 4. Single Mode NonZero Dispersion shifted Fiber 5. MM 62.5/125nm 6. MM 50/125 nm
CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

53

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
DUCT METALLIC O.F. CABLE - – SAUDI TELECOM (STC)

STANDARDS
Reference Standards: MAT-1601 (STC) Fiber Specifications : Refer Page nos : 44-45 Testing Procedures : IEC-60794-1 (or) EIA/TIA-455

PERFORMANCE CHARACTERISTICS
Storage Temperature: -10 C to +70 C Operating Temperature: -10 C to +70 C Max Pulling Tension: 2000 Newton

ORDERING INFORMATION A
Outdoor Duct

D

M
Metallic * Fiber Type * Fiber Count

S
STC

DIRECT BURIED METALLIC O.F. CABLE - – SAUDI TELECOM (STC)

STANDARDS
Reference Standards: MAT-1601 (STC) Fiber Specifications : Refer Page nos : 44-45 Testing Procedures : IEC-60794-1 (or) EIA/TIA-455

PERFORMANCE CHARACTERISTICS
Storage Temperature: -10 C to +70 C Operating Temperature: -10 C to +70 C Max Pulling Tension: 2000 Newton

ORDERING INFORMATION A
Outdoor Direct Buried

DB

M
Metallic * Fiber Type * Fiber Count

S
STC

* Fiber Type 1. Single Mode Dispersion Unshifted Fiber (Matched Clad) 2. Single Mode Dispersion Unshifted Fiber (Depressed Clad) 3. Single Mode Dispersion Shifted Fiber 4. Single Mode NonZero Dispersion shifted Fiber 5. MM 62.5/125nm 6. MM 50/125 nm

CONTENTS CONTENTS

Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

54

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
INDOOR BREAK OUT O.F. CABLE – SAUDI TELECOM (STC)

STANDARDS
Reference Standards: MAT-1602 (STC) Fiber Specifications : Refer Page nos : 44-45 Testing Procedures : IEC-60794-1 (or) EIA/TIA-455

PERFORMANCE CHARACTERISTICS
Storage Temperature: -10 C to +70 C Operating Temperature: -10 C to +70 C Max Pulling Tension: 1000 Newton

ORDERING INFORMATION

B
Indoor Breakout

BO

L
Loose tube type * Fiber Type * Fiber Count

S
STC

INDOOR DISTRIBUTION O.F. CABLE – SAUDI TELECOM (STC)

STANDARDS
Reference Standards: MAT-1602 (STC) Fiber Specifications : Refer Page nos : 44-45 Testing Procedures : IEC-60794-1 (or) EIA/TIA-455

PERFORMANCE CHARACTERISTICS
Storage Temperature: -10 C to +70 C Operating Temperature: -10 C to +70 C Max Pulling Tension: 500 Newton

ORDERING INFORMATION

B
Indoor Direct Buried

DB

N
Non-Metallic * Fiber Type * Fiber Count

S
STC

* Fiber Type 1. Single Mode Dispersion Unshifted Fiber (Matched Clad) 2. Single Mode Dispersion Unshifted Fiber (Depressed Clad) 3. Single Mode Dispersion Shifted Fiber 4. Single Mode NonZero Dispersion shifted Fiber 5. MM 62.5/125nm 6. MM 50/125 nm
CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

55

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
DIRECT BURIED NON METALLIC O.F. CABLE-SCECO CENTRAL

STANDARDS
Reference Standards: TS-16.27 (SCECO-CENTRAL) Fiber Specifications : Refer Page nos : 44-45 Testing Procedures : IEC-60794-1 (or) EIA/TIA-455

PERFORMANCE CHARACTERISTICS
Storage Temperature: -40 C to +70 C Operating Temperature: -40 C to +70 C Max Pulling Tension: 2700 Newton

ORDERING INFORMATION A
Outdoor Direct buried

DB

N
Non-Metallic * Fiber Type * Fiber Count

S
SCECO-CENTRAL

TACTICAL O.F. CABLE

STANDARDS
Reference Standards: Industrial Standard Fiber Specifications : Refer Page nos : 44-45 Testing Procedures : IEC-60794-1 (or) EIA/TIA-455

PERFORMANCE CHARACTERISTICS
Storage Temperature: -40 C to +70 C Operating Temperature: -40 C to +70 C Max Pulling Tension: 2700 Newton

ORDERING INFORMATION I
Indoor Duct

DU

N
Non-Metallic * Fiber Type * Fiber Count

S
TACTICAL

* Fiber Type 1. Single Mode Dispersion Unshifted Fiber (Matched Clad) 2. Single Mode Dispersion Unshifted Fiber (Depressed Clad) 3. Single Mode Dispersion Shifted Fiber 4. Single Mode NonZero Dispersion shifted Fiber 5. MM 62.5/125nm 6. MM 50/125 nm

CONTENTS CONTENTS

Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

56

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
SINGLE MODE FIBER SPECIFICATIONS (IN CABLES) PARAMETER SPECIFICATION ITU-T G.652 Dispersion Unshifted
Matched Clad

Reference Standard Fiber Type
Optical Characteristics

ITU-T G.655 Non-Zero Dispersion Unshifted
Reduced Slope Large Effective Area

Outdoor and Indoor/Outdoor Cables Attenuation (dB/km) 1310 nm 1550 nm Indoor Cables Attenuation (dB/km) 1310 nm 1550 nm Point Discontinuity (dB) at 1310 /1550nm Chromatic Dispersion (ps/nm.km) 1285 ~ 1330 nm 1530 ~1565 nm 1550 nm 1565 ~ 1625 nm Zero Dispersion Wavelength (nm) Slope at Zero Dispersion (ps/nm km) Polarization Mode Dispersion (ps/km) Mode Field Diameter (µm) 1310nm 1550nm Cable Cutoff Wavelength (nm) Macro Bend Attenuation (dB) 1310/1550 nm 100 turns, 60 mm mandrel 1 turn, 32 mm mandrel Geometrical Characteristics Cladding Diameter (µm) Coating Diameter (µm) Cladding Concentricity Error (µm) Cladding Non-circularity (%) Coating Concentricity Error (µm) Mechanical Characteristics Proof Test (kpsi) Environmental Characteristics Temperature Cycling - 60o C to + 85 o C Attenuation Increase (dB) at 1310nm/1550nm
2.

< 0.35 < 0.22 < 0.40 < 0.50 < 0.1 < 3.5 < 18 < 18 < 20 1300 to 1324 < 0.092 < 0.5 9.3 + 0.7 10.5 + 1.0 < 1260 < 0.05 < 0.5 125 + 1 245 + 10 < 0.8 <2 < 12 100

--< 0.25 --< 0.50 < 0.1 NA 2.6 to 6.0 Non Zero 4.0 to 8.6 <1530 < 0.050 < 0.2 NA 8.4 + 0.6 < 1260 < 0.05 < 0.5 125 + 1 245 + 10 < 0.8 <2 < 12 100

--< 0.25 --< 0.50 < 0.1 NA 2.0 to 6.0 Non Zero 4.5 to 11.2 <1530 < 0.085 < 0.2 NA 9.6 + 0.4 < 1480 < 0.05 < 0.5 125 + 1 245 + 10 < 0.8 <2 < 12 100

< 0.1

< 0.1

< 0.1
CONTENTS CONTENTS

Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

57

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
MULTI MODE FIBER SPECIFICATIONS (IN CABLES) PARAMETER SPECIFICATION

Reference Standard Fiber Type
Optical Characteristics 62.5/125µm

ITU-T G.651 Graded Index
50/125µm 50/125µm Laser Optimized

Outdoor and Indoor/Outdoor Cables Attenuation (dB/km) 850 nm 1300 nm Band width (MHz.Km) 850 nm 1300 nm Indoor Cables Attenuation (dB/km) 850 nm 1300 nm Band width (MHz.Km) 850 nm 1300 nm

< 3.2 < 1.0 > 400 > 160

< 3.0 < 1.0 > 800 > 500

< 3.0 < 1.0 > 1000 > 500

< 3.5 < 1.5 > 400 > 160

< 3.2 < 1.2 > 800 > 500

--< 0.50 >1000 > 500

Point Discontinuity (dB) at 850/1300nm Numerical Aperture Macro Bend Attenuation (dB) 850/1300 nm 100 turns, 60 mm mandrel Geometrical Characteristics Core Diameter (µm) Cladding Diameter (µm) Coating Diameter (µm) Cladding Concentricity Error (µm) Cladding Non-circularity (%) Coating Concentricity Error (µm) Mechanical Characteristics Proof Test (kpsi) Environmental Characteristics Temperature Cycling - 60o C to + 85 o C Attenuation Increase (dB) at 850nm/1300nm

< 0.2 0.275 + 0.015 < 0.5

< 0.2 0.200 + 0.015 < 0.5

< 0.2 0.200 + 0.015 < 0.5

62.5 + 3 125 + 1 245 + 10 <3 <2 < 12 100

50 + 1 125 + 1 245 + 10 <3 <2 < 12 100

50 + 1 125 + 1 245 + 10 <3 <2 < 12 100

< 0.2

< 0.2

< 0.2

CONTENTS CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

58

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
MEFC FIBER OPTIC SERVICES

MEFC Fiber Optic Services

Customized, Fiber to Home, Office, Desk, (FTTX)

Fiber Optic Training & Certification

FOC Network Consultant, Technical Assistance Network Design and Site Survey

Troubleshooting, Fault Location and Restoration

OSP Project Engineering Services, Cable Installation, Splicing Termination and Testing

MEFC OFFERS RIGHT FIBER SELECTION FOR YOUR NETWORK

Non Zero Dispersion Shifted SM Fiber ITU (G 655)

Long Haul/Metro Express
Long Haul

Metro Express Metro Access

Metro Access/ Broadband Networks

LOW WATER PEAK SM FIBER ITU (G.652.c,d)

LAN/Campus 50/62.5 Laser Optimized ITU G 651 Multi Mode Fiber

CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

59

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
RELATED TRADINGS - ACCESSORIES
FIBER ACCESSORIES

CONNECTORS

SALIENT FEATURES
MEFC offers all kinds of industry standard connectors of superior quality. Connectors are IEC, Bellcore compliance. FC, ST, SC, MT-RJ, LC style connectors are available with high quality Zirconia of high precision. These connectors have low insertion loss and low back reflection.

APPLICATIONS
-CATV -Optical Network Equipment -Testing Equipment

SPECIFICATION
Insertion Loss Durability Temperature Cycling Humidity Cycling Vibration Impact
<0.3 dB <0.2 dB, 500Matings -40 C to +80 C, 40 Cycles 75 C, 95%/ 336 Hours 10 ~ 55 Hz, 2 Hrs 1.5m drop, 8 times

CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

60

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
FIBER ACCESSORIES

PATCH CORDS/PIG TILS

MEFC manufactures superior quality pigtails and patch cords with customized connectors and lengths. Our Patch cords provide highest level of connectivity for all your fiber interconnects applications. Manufactured and tested to Telcordia GR 326 requirements with precision zirconia ferrules and environmentally rugged connectors and cable.

SALIENT FEATURES
Excellent Return Loss Ultra Low Insertion Loss Single Mode and Multi Mode FC, SC, ST, LC, MU, MT-RJ Style Connectors PC, UPC, or APC Available in 3mm, 2mm, 0.9um Dust Cover


APPLICATIONS
- Intra building backbone cross connects - CATV - Telecommunication Network - LAN, WAN

SPECIFICATION
Insertion Loss Durability Temperature Cycling Humidity Cycling Vibration Impact
<0.3 dB <0.2 dB, 500Matings -40 C to +80 C, 40 Cycles 75 C, 95%/ 336 Hours 10 ~ 55 Hz, 2 Hrs 1.5m drop, 8 times

CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

61

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
FIBER ACCESSORIES

JOINT CLOSURE 1

JOINT CLOSURE 2

TERMINATION BOX1

TERMINATION BOX2

MEFC joint closures and termination boxes provide the perfect and complete solution for the protection of the jointing points of optical fibers from environment. These are versatile and universal products, which can be used for any kind of optical fiber cables. Made from best quality raw materials and provide long-term reliability to the network.

JOINT CLOSURE
SALIENT FEATURES
- Made of tough industrial Plastic - Easy to install without special tools - Straight through and Branch out - Reusable components - Single Ended design

TERMINATION BOX
SALIENT FEATURES
- Extra fiber and patch cord storage - Dust an moisture entry protection - Single Ended design

Closure

APPLICATIONS
- Intra building backbone cross connects - CATV - Telecommunication Network - LAN, WAN - Indoor and Outdoor installation

CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

62

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
FIBER OPTIC GLOSSORY
Absorption That portion of optical attenuation in optical fiber resulting from the conversion of optical power to heat. Caused by impurities in the fiber such as hydroxyl ions. The half-angle of the cone within which incident light is totally internally reflected by the fiber core. It is equal to sin-1(NA). Abbreviation for angle polished connector. A 5°-15° angle on the connector tip for the minimum possible back reflection. A protective layer, usually metal, wrapped around a cable. A transmission standard widely used by the telecom industry. A digital transmission-switching format with cells containing 5 bytes of header information followed by 48 data bytes. Part of the B-ISDN standard. Loss of signal power between points. In optical cables, attenuation is a ratio of input power vs. output power, measured in decibels per unit length, usually dB/km. A factor expressing optical power loss per unit of length, expressed in dB/Km. A photodiode that exhibits internal amplification of photocurrent through avalanche multiplication of carriers in the junction region. The average level of power in a signal that varies with time. In cases where light is launched into an optical fiber, back reflection refers to the light that is returned to the launch point. The return of a portion of scattered light to the input end of a fiber; the scattering of light in the direction opposite to its original propagation. A high-speed transmission system used to connect relatively distant points. Backbone networks can be used to join autonomous networks within buildings or between different buildings The logarithm to the base 10 of a power ratio, expressed as B = log10(P1/P2), where P1 and P2 are distinct powers. The decibel, equal to onetenth bel, is a more commonly used unit. Attenuation caused by high-order modes radiating from the outside of a fiber optic wave-guide, which occur when the fiber is bent around a small radius. See also macro bending, micro bending. The information carrying capacity of a fiber. The bandwidth for a given wavelength is the lowest frequency at which optical power has decreased by 3 dB and is expressed in MHz•km. The radius of curvature that an optical fiber cable can bend without causing harmful effects on the optical or mechanical performance of the cable. The fraction of bits transmitted that are received incorrectly.
CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

Acceptance Angle

APC

Armor Asynchronous Transfer Mode (ATM)

Attenuation

Attenuation Coefficient

Avalanche Photodiode (APD)

Average Power Backreflection (BR)

Backscattering

Backbone

Bel (B)

Bending Loss

Bandwidth

Bend Radius

BER (Bit Error Rate)

63

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
FIBER OPTIC GLOSSORY
Bidirectional Operating in both directions. Bidirectional couplers operate the same way regardless of the direction light passes through them. Bidirectional transmission sends signals in both directions, sometimes through the same fiber. Having a refractive index that differs for light of different polarizations. A method of communication where the signal is transmitted by being impressed on a high-frequency carrier. In optical fiber, a protective coating applied directly to the fiber. 2) A routine or storage used to compensate for a difference in rate of flow of data, or time of occurrence of events, when transferring data from one device to another. One or more optical fibers enclosed, with strength members, in a protective covering. A cable that is connector terminated and ready for installation. The wavelength range between 1530 nm and 1562 nm used in some CWDM and DWDM applications Maximum number of channels that a cable system can carry simultaneously. Different wavelengths travel along an optical medium at different speeds. Wavelengths reach the end of the medium at different times, causing the light pulse to spread. This chromatic dispersion is expressed in picoseconds (of dispersion) per kilometer (of length) per nanometer (of source bandwidth). It is the sum of material and waveguide dispersion. The layer of material, usually glass, that immediately surrounds the fiber core. The cladding is usually coated with another material to provide protection when handling. A mode confined to the cladding; a light ray that propagates in the cladding The process of cutting an optical fiber by a controlled fracture of the glass, for the purpose of obtaining a fiber end, which is flat, smooth, and perpendicular to the fiber axis. Coating A material applied to the cladding for protective purposes. CWDM allows eight or fewer channels to be stacked in the 1550 nm region of optical fiber, the C-Band In a wire or cable, the measurement of the location of the center of the conductor with respect to the geometric center of the circular insulation. A mechanical or optical device that provides a demountable connection between two fibers or a fiber and a source or detector. The fixed or stationary half of a connection that is mounted on a panel/bulkhead. Receptacles mate with plugs. The central part of the glass construction through which light is transmitted. CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

Birefringent Broadband

Buffer

Cable

Cable assembly C-Band

Channel Capacity Chromatic Dispersion

Cladding

Cladding Mode Cleave

Coarse Wavelength-division Multiplexing (CWDM) Concentricity

Connector

Connector Receptacle

Core

64

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
FIBER OPTIC GLOSSORY
Cut-off Wavelength Decibel (dB) The wavelength at which a singlemode fiber transmits a single mode of light The standard unit used to express gain or loss of optical power. A standard logarithmic unit for the ratio of two powers, voltages or currents. In fiber optics, the ratio is power. dB = 10•log10 (P1/P2) This refers to the transmission of a multiplicity of closely spaced wavelengths in the 1550 nm region. Wavelength spacings are usually 100 GHz or 200 GHz, which corresponds to 0.8 nm or 1.6 nm. DWDM bands include the C-Band, the S-Band, and the L-Band. Nonmetallic. All-dielectric designs are inherently nonconductive; all-dielectric cables contain no metal and are lightning resistant The cause of bandwidth limitations in a fiber. Dispersion causes a broadening of input pulses along the length of the fiber. Two major types are mode dispersion caused by differential optical path lengths in a multimode fiber and material dispersion caused by a differential delay of various wavelengths of light in a waveguide material A fiber that has the opposite dispersion of the fiber being used in a transmission system. It is used to nullify the dispersion caused by that fiber. This module has the opposite dispersion of the fiber being used in a transmission system. It is used to nullify the dispersion caused by that fiber. It can be either a spool of a special fiber or a grating based module. A type of single-mode fiber designed to have zero dispersion near 1550 nm. This fiber type works very poorly for DWDM applications because of high fiber non-linearity at the zero dispersion point. This term is used two ways. For multimode fibers, the term means that the fiber is optimized for 850 nm and 1310nm. For single mode fibers the term means that the fiber is optimized for 850 nm and 1310nm. Optimized for 850 nm and 1310 nm operation. For single-mode fibers, the term means that the fiber is optimized for 1310 nm and 1550 nm operation. Duplex Cable Effective Area EIA A two-fiber cable suitable for duplex transmission. The area of a single-mode fiber that carries the light. Abbreviation for Electronic Industries Association. An organization that sets video and audio standards. Optical fibers doped with the rare earth element, erbium, which can amplify light in the 1550 nm region when pumped by an external light source. In a fiber interconnection, that portion of loss not intrinsic to the fiber but related to imperfect joining of a connector or splice. Also called eye diagram. The proper function of a digital system can be quantitatively described by its BER, or qualitatively by its eye pattern. The "openness" of the eye relates to the BER that can be achieved.
CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

Dense Wavelength-division Multiplexing (DWDM)

Dielectric

Dispersion

Dispersion-compensating Fiber (DCF)

Dispersion-compensating Module (DCM)

Dispersion-shifted Fiber (DSF)

Double-window Fiber

Erbium-doped Fiber Amplifier (EDFA)

Extrinsic Loss

Eye Pattern

65

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
FIBER OPTIC GLOSSORY
Ferrule A rigid tube that confines or holds a fiber as part of a connector assembly.

Fiber Distributed Data Interface (FDDI)

An ANSI standard to ensure compatibility of components from different manufacturers. A component installed in a fiber optic transmission system that reduces the power in the optical signal. It is often used to limit the optical power received by the photodetector to within the limits of the optical receiver. A cable containing one or more optical fibers. A transmitter, receiver, and cable assembly that can transmit information between two points. Fiber optic service to a node that is located in a neighborhood Fiber optic service to a node connected by wires to several nearby homes, typically on a block. Fiber optic service to a node located inside an individual home. Standards developed and published by the Electronic Industries Association (EIA) under the EIA-RS-455 series of standards. Nonlinearity common in DWDM systems where multiple wavelengths mix together to form new wavelengths. Most prevalent near the zero-dispersion wavelength and at close wavelength spacings. A method of deriving two or more simultaneous, continuous channels from a transmission medium by assigning separate portions of the available frequency spectrum to each of the individual channels. Reflection losses at the ends of fibers caused by differences in the refractive index between glass and air. The maximum reflection caused by a perpendicular air-glass interface is about 4% or about -14 dB. Abbreviation for fiber under test. Refers to the fiber being measured by some type of test equipment. A core refractive index profile that varies with the radius of the core. An optical fiber having a silica core and a hard polymeric plastic cladding intimately bounded to the core. A fluid or gel whose index of refraction nearly equals that of the fiber's core. Used to reduce Fresnel reflection loss at fiber ends. Also called indexmatching gel. Also refractive index. The ratio of the velocity of light in free space to the velocity of light in a fiber material. Always greater than or equal to one.
The loss of power that results from inserting a component, such AS connector or splice, into a previously continuous path g-wavelength detectors..

Fiber Optic Attenuator

Fiber Optic Cable Fiber Optic Link

Fiber-in-the-Loop (FTTL) Fiber-to-the-Curb (FTTC)

Fiber-to-the-Home (FTTH) FOTP (Fiber Optic Test Procedure)

Four Wave Mixing (FWM)

Frequency-division Multiplexing (FDM)

Fresnel Reflection Loss

FUT

Graded Index Hard-clad Silica Fiber

Index-matching Fluid

Index of Refraction

Insertion Loss

CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

66

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
FIBER OPTIC GLOSSORY
Halogens
Chemicals from the halogen family (chlorine, fluorine, bromine) are typically compounded into plastic materials to improve the flame retardance. When the materials are exposed to a high heat source, halogen gases are released, limiting the spread of flames but potentially causing a health hazard.

Insertion Loss

Total optical power loss caused by insertion of an optical component such as a connector, splice, or coupler into a previously continuous path. Splice losses arising from differences in the fibers being spliced. ISDN is an international standard for transmitting digital information (text, sound, voice, data, video, etc.) The outer, protective covering of the cable. Small and rapid variations in the timing of a waveform due to noise, changes in component characteristics, supply voltages, imperfect synchronizing circuits, etc. A short fiber optic cable with connectors on both ends. Usually, a fiber with a core of 200 µm or more. An optical fiber, developed by Corning, designed to have a large area in the core, which carries the light. An optical fiber used to couple and condition light from an optical source into an optical fiber. Often the launch fiber is used to create an equilibrium mode distribution in multimode fiber. Also called launching fiber. The wavelength range between 1570 nm and 1610 nm used in some CWDM and DWDM applications. In a strict sense, the region of the electromagnetic spectrum that can be perceived by human vision, designated the visible spectrum and nominally covering the wavelength range of 0.4 µm to 0.7 µm. In the laser and optical communication fields, custom and practice have extended usage of the term to include the much broader portion of the electromagnetic spectrum that can be handled by the basic optical techniques used for the visible spectrum. This region has not been clearly defined, but, as employed by most workers in the field, may be considered to extend from the nearultraviolet region of approximately 0.3 µm, through the visible region, and into the mid-infrared region to 30 µm. Synonym for optical fiber. A cable construction in which the optical fiber is placed in a plastic tube having an inner diameter much larger than the fiber itself. The loose tube isolates the fiber from the exterior mechanical forces acting on the cushion. The space between the tube and the fiber is often filled with a gel to cushion the fiber. The amount of a signal's power, expressed in dB, that is lost in connectors, splices, or fiber defects. The total acceptable loss for a given system from transmitter to receiver. Includes cables, splices and connectors. CONTENTS CONTENTS

Intrinsic Losses ISDN (Integrated Services Digital Network) Jacket Jitter

Jumper Large Core Fiber Large Effective Area Fiber (LEAF)

Launch Fiber

L-Band

Light

Lightguide Loose Tube Buffering

Loss Loss Budget

Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

67

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
FIBER OPTIC GLOSSORY
Low Smoke, Zero Halogen (LSZH) Thermoplastic or thermoset jacketing compounds that emit limited smoke and no halogens when exposed to high sources of heat. Pulse dispersion due to the variations in a material's refractive index as a function of wavelength. In an optical fiber, all macroscopic deviations of the fiber's axis from a straight line; distinguished from microbending. A network covering an area larger than a local area network. A wide area network that cover same tropolitan area. Usually, an interconnection of two or more local area networks. Dispersion resulting from different velocities of each wavelength in material. An optical fiber splice accomplished by fixtures or materials, rather than by thermal fusion. Minute but severe bends in fiber that result in light displacement and increased loss. Most microbending can be avoided by the correct selection of materials and proper cabling, handling, and installation techniques A single electromagnetic wave traveling in a fiber. In singlemode fiber, the region in which the light transmitted is larger than the glass core diameter. This mode field diameter is a measured value and often listed as a requirement with core diameter in fiber specifications. A device that removes higher-order modes to simulate equilibrium mode distribution. Dispersion resulting from the different transit lengths of different propagating modes in a multimode optical fiber. Also called modal dispersion. An optical fiber that has a core large enough to propagate more than one mode of light The typical diameter is 62.5 micrometers. A measure of the light acceptance angle of the fiber. A device that amplifies light without converting it to an electrical signal. Optical fiber An optical waveguide comprised of a light carrying core and cladding, which traps light in the core. An instrument that used backscattered light to find faults in optical fiber and infer loss. A condition for launching light into the fiber where the incoming light has a spot size and NA larger than accepted by the fiber, filling all modes in the fiber. A fiber optic cable that has a connector on only one end. An optical fiber made of plastic. A fiber made with a glass core and plastic cladding. The large diameter glass rod from which fiber is drawn
CONTENTS CONTENTS

Material Dispersion

Macrobending

MAN (Metropolitan Area Network)

Material Dispersion Mechanical Splice

Microbending

Mode Mode Field Diameter (MFD)

Mode Filter

Multimode Dispersion

Multimode (MM) Fiber

Numerical aperture (NA) Optical amplifier

Optical time domain reflectometer (OTDR) Overfilled launch

Pigtail Plastic optical fiber (POF) Plastic-clad silica (PCS) fiber Preform

Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

68

MIDDLE EAST FIBER CABLE MANUFACTURING CO.(MEFC)
FIBER OPTIC GLOSSORY
Plenum Cable A cable whose flammability and smoke characteristics allow it to be routed in a plenum area without being enclosed in a conduit. The bending of a beam of light at an interface between two dissimilar media or in a medium whose refractive index is a continuous function of position (graded-index medium). Indoor cables made especially for between floor applications A device that receives a fiber optic signal and regenerates it for retransmission used in very long fiber optic links. The change of direction of light after striking small particles that causes loss in optical fibers. A fiber with a small core, only a few times the wavelength of light transmitted, that only allows one mode of light to propagate. Commonly used with laser sources for high speed, long distance links. A refractive index profile characterized by a uniform refractive index within the core and a sharp decrease at the core-cladding interface. That part of a fiber optic cable composed of aramid yarn, steel strands, or fiberglass filaments that increase the tensile strength of the cable A device that provides for a connection between two fibers, typically intended to be permanent In tight buffer constructions the thermoplastic is extruded directly over the coated fiber, increasing the outside diameter to 900 micron (0.9 mm), an industry standard. Vertical cavity surface emitting laser, a type of laser that emits light vertically out of the chip, not out the edge. A device that couples visible light into the fiber to allow visual tracing and testing of continuity. Some are bright enough to allow finding breaks in fiber through the cable jacket. Dispersion caused by the fact that light travels at different speeds in the core and cladding of singlemode fibers A technique of sending signals of several different wavelengths of light into the fiber simultaneously.. The difference (in dB) between the power budget and the loss budget (i.e. the excess power margin). Wavelength In singlemode fibers, the wavelength at which the effects of chromatic dispersion and waveguide dispersion are lowest; thus providing the greatest information carrying capacity.

Refraction

Riser Cable Repeater, regenerator

Scattering

Single mode fiber

Step Index

Strength Member

Splice (fusion or mechanical)

Tight Buffer

VCSEL

Visual fault locator

Wave guide Dispersion

Wavelength division multiplexing (WDM) Working margin

Zero Dispersion

CONTENTS CONTENTS
Middle East Fiber Cable Mfg.Co.Ltd, Second Industrial Area, P.O.Box: 733, Riyadh – 11383, Kingdom of Saudi Arabia Tel: +966-1-265-0777, Fax: +966-1-265-0203, Website: http://www.mefcf.com/, E-mail: [email protected]

69

Sponsor Documents

Or use your account on DocShare.tips

Hide

Forgot your password?

Or register your new account on DocShare.tips

Hide

Lost your password? Please enter your email address. You will receive a link to create a new password.

Back to log-in

Close