FlexiPlatform Alarms for RNC-OMS

Comments

Content

FlexiPlatform Alarms for RNCOMS

DN70155942
Issue 1-0 en draft

# Nokia Corporation

1 (26)

FlexiPlatform Alarms for RNC-OMS

The information in this document is subject to change without notice and describes only the
product defined in the introduction of this documentation. This document is not an official
customer document and Nokia Networks does not take responsibility for any errors or omissions
in this document. No part of it may be reproduced or transmitted in any form or means without
the prior written permission of Nokia Networks. The document has been prepared to be used by
professional and properly trained personnel, and the customer assumes full responsibility when
using it. Nokia Networks welcomes customer comments as part of the process of continuous
development and improvement of the documentation.
The information or statements given in this document concerning the suitability, capacity, or
performance of the mentioned hardware or software products cannot be considered binding but
shall be defined in the agreement made between Nokia Networks and the customer.
Nokia Networks WILL NOT BE RESPONSIBLE IN ANY EVENT FOR ERRORS IN THIS
DOCUMENT OR FOR ANY DAMAGES, INCIDENTAL OR CONSEQUENTIAL (INCLUDING
MONETARY LOSSES), that might arise from the use of this document or the information in it.
UNDER NO CIRCUMSTANCES SHALL NOKIA BE RESPONSIBLE FOR ANY LOSS OF USE,
DATA, OR INCOME, COST OF PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES,
PROPERTY DAMAGE, PERSONAL INJURY OR ANY SPECIAL, INDIRECT, INCIDENTAL,
PUNITIVE OR CONSEQUENTIAL DAMAGES HOWSOEVER CAUSED.
THE CONTENTS OF THIS DOCUMENT ARE PROVIDED "AS IS". EXCEPT AS REQUIRED
BY APPLICABLE MANDATORY LAW, NO WARRANTIES OF ANY KIND, EITHER EXPRESS
OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NON-INFRINGEMENT,
ARE MADE IN RELATION TO THE ACCURACY, RELIABILITY OR CONTENTS OF THIS
DOCUMENT. NOKIA RESERVES THE RIGHT TO REVISE THIS DOCUMENT OR
WITHDRAW IT AT ANY TIME WITHOUT PRIOR NOTICE.
This document and the product it describes are considered protected by copyright according to
the applicable laws.
NOKIA and Nokia Connecting People are registered trademarks of Nokia Corporation. Other
product names mentioned in this document may be trademarks of their respective companies,
and they are mentioned for identification purposes only.
Copyright © Nokia Corporation 2006. All rights reserved. Reproduction, transfer, distribution or
storage of part or all of the contents in this document in any form without the prior written
permission of Nokia is prohibited.

2 (26)

# Nokia Corporation

DN70155942
Issue 1-0 en draft

Contents

Contents
Contents 3
1
1.1
1.1.1

Changes in FlexiPlatform alarms for RNC-OMS 5
Changes within the Nokia FlexiPlatform release 4 5
Changes in the FlexiPlatform alarms for RNC-OMS 5

2

70005 INCORRECT ALARM DATA 7

3

70030 DISK DATABASE IS GETTING FULL 11

4

70156 DISK DATABASE WATCHDOG START-UP FAILED 15

5

70173 BACKEND DATABASE REQUIRED BY CORBA NAMING
SERVICE IS UNAVAILABLE 17

6

70245 ILLEGAL INTERNAL USAGE OF EXTERNAL ALARM
NOTIFICATION FORMAT 21

7

70256 RESOURCE ALLOCATION OR DE-ALLOCATION FAILURE 23

DN70155942
Issue 1-0 en draft

# Nokia Corporation

3 (26)

FlexiPlatform Alarms for RNC-OMS

4 (26)

# Nokia Corporation

DN70155942
Issue 1-0 en draft

Changes in FlexiPlatform alarms for RNC-OMS

1

Changes in FlexiPlatform alarms for
RNC-OMS
The information contained in this section is for internal use only. Do not reuse
this module in application-specific library configurations. Use only relevant
information to your own change module(s).

1.1

Changes within the Nokia FlexiPlatform release 4

1.1.1

Changes in the FlexiPlatform alarms for RNC-OMS
The following alarms are new in the current FP4 release:
.

70245 ILLEGAL INTERNAL USAGE OF EXTERNAL ALARM
NOTIFICATION FORMAT

.

70256 RESOURCE ALLOCATION OR DE-ALLOCATION FAILURE

The following alarm descriptions have been updated in FP4:

DN70155942
Issue 1-0 en draft

.

70005 INCORRECT ALARM DATA

.

70030 DISK DATABASE IS GETTING FULL

.

70156 DISK DATABASE WATCHDOG START-UP FAILED

.

70173 BACKEND DATABASE REQUIRED BY CORBA NAMING
SERVICE IS UNAVAILABLE

# Nokia Corporation

5 (26)

FlexiPlatform Alarms for RNC-OMS

6 (26)

# Nokia Corporation

DN70155942
Issue 1-0 en draft

70005 INCORRECT ALARM DATA

2

70005 INCORRECT ALARM DATA
Probable cause: Invalid parameter
Event type: Processing error
Default severity: Major
Meaning

The alarm system has been requested to raise or clear an alarm with incorrect
alarm data. One or more arguments provided with the request might have an
invalid value or meaning: null, or they might be empty, too long, out of specified
range, contain non-printable characters, or have an incorrect format. The alarm
number (Specific Problem) might also be unknown. An incorrect format in this
case means, for example, that a character value was entered where a numeric
value was expected. A special case of an incorrect format is if the quotes (")
surrounding the value of an information field are missing from an alarm
notification record in the syslog.
The alarm which is requested to be raised or cleared with incorrect data is not
processed further but the information is put as additional information in this
alarm. If the alarm number is unknown, then the actual fault for which the alarm
has been raised is also left unknown.
Identifying additional information fields

1. Erroneous data
.

Identifies the alarm data that was incorrect or that was totally missing.
Only the name of the first field containing invalid data is mentioned here.
Possible values are:
.
SP: Specific Problem given in the data is not known by the alarm
system, or is not reasonable.
.
MOId: Managed Object Id given in the data is not reasonable
.
PS: Perceived Severity given in the data is not reasonable
.
applId: Application Id given in the data is not reasonable

DN70155942
Issue 1-0 en draft

# Nokia Corporation

7 (26)

FlexiPlatform Alarms for RNC-OMS

.
.

.

.

.

AAI: Additional Information given in the data is not reasonable.
IAAI: Identifying Additional Information given in the data is not
reasonable.
alarmTime: Alarm time is presented in too long a format, or is in
non-numerical format.
length: The combined length of the string type fields (Managed
Object Id, Application Id, Application Additional Information,
Identifying Application Additional Information) given in the data
exceeds the maximum value of 896 characters. Note that in this case,
both Application Id and Managed Object Id in the given data are
considered as invalid, as only the combined length is verified.

In addition, these values are also possible for RNC alarms:
.
rncLocalMOId: the Local Managed Object Id given in the data is not
reasonable;
.
rncApplicationId: the RNC Application Id given in the data is not
reasonable;
.
rncNotificationId: the RNC Notification Id given in the data is not
reasonable;
.
rncFlowControl: the RNC Flow Control given in the data is not
reasonable.

2. Specific Problem
.

Specific problem (the alarm number) of the invalid alarm can also contain
the original invalid value if this was the invalid field.

Additional information fields

3. Managed Object Id
.

Distinguished name of the managed object that was given as the Managed
Object Id in the invalid alarm. If the MOId itself was the incorrect data,
then the value fsManagedObjectId=invalid,
fsClusterId=ClusterRoot is displayed in this field.

Instructions

Fill in a problem report and send it to your local Nokia representative.
Clearing

Clear the alarm with the Alarm Browser after correcting the fault as presented in
Instructions, in other words, after sending the report to your local Nokia
representative.

8 (26)

# Nokia Corporation

DN70155942
Issue 1-0 en draft

70005 INCORRECT ALARM DATA

Testing instructions

Use, for example, the alarm system command line interface (CLI) command
flexalarm to send a request to raise or clear an alarm with a Specific Problem
that does not exist.
For example:
$> flexalarm -raise -mo=<myMO> -ap=<myAP> -sp=700111

where <myMO> and <myAP> have the correct format.
Since the 700111 Specific Problem does not exist, alarm 70005 is raised.

DN70155942
Issue 1-0 en draft

# Nokia Corporation

9 (26)

FlexiPlatform Alarms for RNC-OMS

10 (26)

# Nokia Corporation

DN70155942
Issue 1-0 en draft

70030 DISK DATABASE IS GETTING FULL

3

70030 DISK DATABASE IS GETTING
FULL
Probable cause: Storage capacity problem
Event type: Processing error
Default severity: Major
Meaning

The disk storage area reserved for disk database is filling up.
The disk database is still fully operational. If the database fills up completely, its
services cannot be used anymore.
Identifying additional information fields

Additional information fields

1.

Max size: the maximum size of database in kB

2.

Fill ratio: the fill ratio of the database

Instructions

The actions to be done in order to avoid a completely full database are databasespecific, so contact your local Nokia representative immediately and provide
them with the information you obtained from the alarm notification's fields.
Clearing

Clear the alarm with the Alarm Browser after correcting the fault as presented in
Instructions.

DN70155942
Issue 1-0 en draft

# Nokia Corporation

11 (26)

FlexiPlatform Alarms for RNC-OMS

Testing instructions

You can test the alarm either by filling the database until the allocated space
exceeds the fill ratio alarm limit, or by decreasing the fill ratio alarm limit under
the current fill ratio of the database. You can also combine these two approaches.
.

In the first approach, you simply create a dummy table to the database and
insert rows to it until the fill ratio exceeds the fill ratio alarm limit (see
attribute fsdbFillRatioAlarmLimit in the DB fragment).

.

In the second approach, you must use a parameter management tool to
change the fsdbFillRatioAlarmLimit attribute of the DB fragment to
a smaller value than the current fill ratio of the database. After this, you
must restart the recovery group of the database (fshascli -r /<RG>).
The current fill ratio of the database can be estimated as follows:
1.
Get the maximum size of the database either by checking the
innodb_data_file_path attribute from the MySQL instance
configuration file (/var/mnt/local/MySQL_<DBName>/my.
cnf) or by connecting to the instance and entering the following
command:
SHOW GLOBAL VARIABLES LIKE 'innodb_data_file_path'\G

The mximum size is the sum of the maximum size of each InnoDB
data file listed in the value. For example, the following result means
that the maximum size is 500 MB (512'000 kB):
*************************** 1. row ***************************
Variable_name: innodb_data_file_path
Value: ibdata1:500M

2.

Get the free space of the database by connecting to the instance and
entering the following command for any InnoDB table:
SHOW TABLE STATUS FROM <schema> LIKE '<table>'\G

<schema> is the schema name of the InnoDB table and <table> is
the name of the table. The comment column of the result set shows
the free space.
For example, the following result means that the database has
492'544 kB free space (when using the example size of step 1, the
result leads to fill ratio of 3,8%):
mysql> SHOW TABLE STATUS FROM test LIKE 'mysqlwdtest'\G
*************************** 1. row ***************************
Name: mysqlwdtest
...
Comment: InnoDB free: 492544 kB

3.

It does not matter which InnoDB table is used in the query.
Check the schema and the name of an arbitrary InnoDB table by
using the following query:
SELECT table_schema,table_name
FROM information_schema.tables

12 (26)

# Nokia Corporation

DN70155942
Issue 1-0 en draft

70030 DISK DATABASE IS GETTING FULL

WHERE engine = 'InnoDB'
LIMIT 1;

DN70155942
Issue 1-0 en draft

# Nokia Corporation

13 (26)

FlexiPlatform Alarms for RNC-OMS

14 (26)

# Nokia Corporation

DN70155942
Issue 1-0 en draft

70156 DISK DATABASE WATCHDOG START-UP FAILED

4

70156 DISK DATABASE WATCHDOG
START-UP FAILED
Probable cause: Configuration or Customizing Error
Event type: Processing error
Default severity: Critical
Meaning

Start-up of the disk database watchdog has failed due to a configuration error.
Because the disk database and its watchdog belong to the same recovery unit
(RU), the disk database watchdog start-up failure means that the database is not
available.
Identifying additional information fields

Additional information fields

1.

Reason. Possible values:
.
1 - Disk database watchdog failed to read the parameters from
parameter management.
.
2 - Invalid or missing parameter value.

2.

List of invalid or missing parameters if the reason for the alarm is 2.

Instructions

Check the Application Additional Information field for a reason for the
configuration error:

DN70155942
Issue 1-0 en draft

.

Reason 1: Disk database watchdog failed to read the parameters from
parameter management

.

Reason 2: Invalid or missing parameter value

# Nokia Corporation

15 (26)

FlexiPlatform Alarms for RNC-OMS

and continue according to the following procedure:
1.

Check that the following parameters exist in parameter management for
each database entry in the database fragment with the DN (Distinguished
Name) "fsFragmentId=DB, fsClusterId=ClusterRoot":
fsdbRedundancyModel
fsdbDataSourceName
fsdbFillRatioAlarmLimit
fsdbFillRatioCheckFreq

2.

Use Parameter Tool to get the values of those parameters for the database
in question. To find those parameters, use the value of the Managed Object
field in Alarm Browser, for example:

fsdbName=DB_Alarm,fsFragmentId=DB,fsClusterId=ClusterRoot

3.

Send your Nokia representative the found values and/or parameters that do
not exist.

Clearing

Clear the alarm with Alarm Browser after correcting the fault as presented in
Instructions.
Testing instructions

The easiest way to raise the alarm is to use a parameter management tool to
change the fsdbFillRatioAlarmLimit or fsdbFillRatioCheckFreq
attribute of the database to a non-numeric value and to restart the recovery group
of the database (fshascli -r /<RG>).

16 (26)

# Nokia Corporation

DN70155942
Issue 1-0 en draft

70173 BACKEND DATABASE REQUIRED BY CORBA NAMING SERVICE IS
UNAVAILABLE

5

70173 BACKEND DATABASE REQUIRED
BY CORBA NAMING SERVICE IS
UNAVAILABLE
Probable cause: Underlying Resource Unavailable
Event type: Processing error
Default severity: Major
Meaning

The MySQL database instance DB_CosNaming, used by the public and private
CORBA naming service (NaS) instances, cannot be contacted by the NaS
wrapper. Note that the recovery group that owns the backend database is
NamingServiceDB and CORBA NaS instances belong to recovery groups
PrivateCosNaming and PublicCosNaming.
The CORBA NaS is not able to store data in the database. Therefore the CORBA
NaS is not functional and replies to the high availability services (HAS)
heartbeats with a failure indication.
Identifying additional information fields

Additional information fields

Instructions
.

Check that the error situation still exists
/opt/Nokia/SS_Naming/bin/ns_listall
/opt/Nokia/SS_Naming/bin/ns_listall public

DN70155942
Issue 1-0 en draft

# Nokia Corporation

17 (26)

FlexiPlatform Alarms for RNC-OMS

These commands should list the content of the private and the public
naming graphs if the NaS is working correctly. If these commands throw
exceptions, the NaS is not working correctly which may result, for
example, from an unavailable backend database.
.

Check if the backend database DB_CosNaming (RG NamingServiceDB)
is unlocked and active.
fshascli -s /NamingServiceDB

If the NamingServiceDB is locked, unlock it.
fshascli -u /NamingServiceDB

After a few seconds the database should have restarted and the NaS should
have automatically re-established connections. Ensure the restart and the
re-established connections by issuing the ns_listall commands
mentioned above.
.

If this does not solve the problem, there is something wrong with the
database deployment or configuration. In that case, also the alarm 70156
DISK DATABASE WATCHDOG START-UP FAILED should be raised by
the MySQL DB watchdog dedicated for the DB_CosNaming database
instance.
The following steps describe the error checking procedure if
NamingServiceDB RG fails (see alarm description 70156 DISK
DATABASE WATCHDOG START-UP FAILED for more information).

1.

Check the master-syslog for any indication of errors.
less /var/log/master-syslog

2.

Check that the LDAP server is up and running.
.
Check that the RG owning the LDAP server is unlocked.
fshascli -s /Directory
.

Check that the LDAP server is really working by listing the content
of the LDAP tree (CTRL-C aborts the listing).
ldapsearch

3.

If the LDAP is working correctly, check that the DB directory mount is
functional:
.
Lock the NamingServiceDB RG (if not yet locked).
.
Mount the database directory manually.
a.
Create the SW RAID (md device) to where the
DB_CosNaming directory is stored at.
create_sw_raid /dev/md8 \
/dev/VG_62/MySQL_DB_CosNaming \
/dev/VG_63/MySQL_DB_CosNaming

18 (26)

# Nokia Corporation

DN70155942
Issue 1-0 en draft

70173 BACKEND DATABASE REQUIRED BY CORBA NAMING SERVICE IS
UNAVAILABLE

Note that the device paths given as arguments above may be
different in your system.
Check the correct device paths from:
/opt/Nokia_BP/etc/ldapfile/ldif_in/PFSAN*.
ldif

The device paths are defined under an entry defining the
FSHWSWRAID object class for the NaS:
dn: fshwStorageResourceName=/dev/md8, fshwSANName=0,
fsFragmentId=HW, fsClusterId=ClusterRoot
fshwStorageResourceName: /dev/md8
objectClass: FSHWStorageResource
objectClass: FSHWSWRAID
objectClass: extensibleObject
fshwRAIDLevel: 1
fshwPartitionName: /dev/VG_62/MySQL_DB_CosNaming
fshwPartitionName: /dev/VG_63/MySQL_DB_CosNaming
fsUserComment: MySQL DB for CORBA Naming Service

b.

Mount the directory.
mkdir /tmp/tmp_nasDB
mount /dev/md8 /tmp/tmp_nasDB

Remember to unmount the directory and to stop the md device after the
following checks have been performed (see the last step).
4.

Check that the database disk content is accessible and readable
ls -la /tmp/tmp_nasDB

5.

Check that the my.cnf and odbc.ini files exist in that directory and have
read access rights. Check also that these files are identical to those under
the SS_Naming home directory.

diff /tmp/tmp_nasDB/odbc.ini /opt/Nokia/SS_Naming/etc/odbc.ini
diff /tmp/tmp_nasDB/my.cnf /opt/Nokia/SS_Naming/etc/my.cnf

6.

Check the mysql.err file for any error indications. You can also find this
file from the /tmp/tmp_nasDB directory.

7.

Remove the mount and stop the md devices
a.
Unmount and remove the directory.
umount /tmp/tmp_nasDB
rmdir /tmp/tmp_nasDB

b.

Stop the md device.
mdadm --manage -S /dev/md8

If any of the preceding checks fail, a major software failure exists in the
system. In that case, contact your Nokia representative with the
information gathered during the preceding steps.

DN70155942
Issue 1-0 en draft

# Nokia Corporation

19 (26)

FlexiPlatform Alarms for RNC-OMS

Clearing

HAS clears the alarm automatically when it has detected the NaS to be faulty and
therefore restarted the PrivateCosNaming and PublicCosNaming recovery
groups.
However, if the backend database remains faulty, the alarm is raised again. This
may result in a restart loop constantly raising the same alarm. Therefore, if the
problem seems to be permanent, it is recommended to lock the NaS and the
database recovery groups with the following commands:
fshascli -l /NamingServiceDB
fshascli -l /PublicCosNasming
fshascli -l /PrivateCosNaming

and to clear the alarm manually before performing the steps for solving the error.

20 (26)

# Nokia Corporation

DN70155942
Issue 1-0 en draft

70245 ILLEGAL INTERNAL USAGE OF EXTERNAL ALARM NOTIFICATION FORMAT

6

70245 ILLEGAL INTERNAL USAGE OF
EXTERNAL ALARM NOTIFICATION
FORMAT
Probable cause: Software Program Error
Event type: Processing error
Default severity: Major
Meaning

Application raised or cleared an alarm containing an internal application Id and
provided its own alarm time. Application is allowed to provide alarm time only
for external alarms (alarms with external application Id). This alarm is also raised
if the application raised or cleared an alarm containing an external application Id
but did not provide its own alarm time.
The original alarm is discarded.
Identifying additional information fields

Data from the original alarm:
1.

Managed Object Id

2.

Specific problem

3.

Identifying application additional information

(Application Id is present in the Managed Object Id field of the alarm)
Additional information fields

-

DN70155942
Issue 1-0 en draft

# Nokia Corporation

21 (26)

FlexiPlatform Alarms for RNC-OMS

Instructions

Fill in a problem report with the alarm data and send it to your Nokia
representative.
Clearing

Clear the alarm with Alarm Browser after correcting the fault as presented in
Instructions.
Testing instructions

1.

Create a text file containing the following single row:

2005 Jul 20 22:09:00 ALARM RAISE SP=70156 \
MO=fshaProcessInstanceName= SolidWDforAlarmType,\
fshaRecoveryUnitName=FSAlarmDBServer,fsipHostName=WAS,\
fsFragmentId=Nodes,fsFragmentId=HA,fsClusterId=ClusterRoot \
AP=fshaProcessInstanceName=SolidWDforAlarmType,\
fshaRecoveryUnitName=FSAlarmDBServer,fsipHostName=WAS,\
fsFragmentId=Nodes,fsFragmentId=HA, fsClusterId=ClusterRoot \
SE=5 IINFO="1 AlarmDB /var/mnt/local/Solid_DB_Alarm" TIME=E1124564940350

2.

Use the Parameter Tool to memorize the value of the
fsParameterId=fsLogFileName,
fsAlarmProcessorConfigurationId=Default,
fsAlarmProcessorId=AlarmProcessor1, fsFragmentId=
AlarmProcessors, fsFragmentId=AlarmMgmt,
fsClusterId=ClusterRoot attribute in the alarm processor LDAP

configuration and replace it with the name of the created file.
3.

Restart alarm processor with the following command:
fshascli -r /<Node>/FSAlarmSystemServer/AlarmProcessor

where <Node> is the name of the node where alarm processor is deployed.

22 (26)

4.

After verifying that an alarm for the situation has been raised, clear it with
Alarm Browser.

5.

Use the Parameter Tool to restore the original name of the alarm log file.

6.

Restart alarm processor again.

# Nokia Corporation

DN70155942
Issue 1-0 en draft

70256 RESOURCE ALLOCATION OR DE-ALLOCATION FAILURE

7

70256 RESOURCE ALLOCATION OR DEALLOCATION FAILURE
Probable cause: Software Program Abnormally Terminated
Event type: Processing error
Default severity: Major
Meaning

Allocation or deallocation of resources to or from a computer node in the cluster
has failed.
Applications running in the cluster are often identified with resources that are
allocated to the node before the application is started and released from the node
after the application has terminated. Such resources can, for example, be TCP/IP
addresses that are associated with the service provided by the software or a disk
partition that for example contains the application database. In addition, the
application can allocate and deallocate other resources (for example, start and
stop 3rd party applications) in its control scripts.
An operation failure has been reported for the defined recovery unit while it was
starting or stopping.
If the error occurred when an application was starting, application start-up is
aborted. In case of a permanent fault, the service provided by the application is
now down. With a transient or node-specific fault, and providing that the
application has a standby, the application may have been restarted successfully on
another node.
If the fault happened while the application was terminating, the node on which
the error happened has now been restarted to restore it to a known state. If the
node has restarted successfully or the application has a standby resource, the
application has likely already restarted, and service is again available.

DN70155942
Issue 1-0 en draft

# Nokia Corporation

23 (26)

FlexiPlatform Alarms for RNC-OMS

Identifying additional information fields

Additional information fields

1.

Name of the recovery group to which the recovery unit belongs. For
example, "/Directory".

2.

Situation when the failure happened: string "allocating" or "de-allocating"

3.

Type of the resource allocation: "IP(address)", "disk(mount point)" or
"ctrlscript". For example, "IP(192.1.1.78)" or "disk(sysimg)".

4.

Only present if argument 3 is "ctrlscript". Contains the name of the control
script that reported the failure. For example, "RUControlDirectoryServer.
sh"

Instructions

1.

Log into the cluster as root user to check the situation.

2.

Use the fshascli command to check the state of all recovery units within
the recovery group (name of the recovery group is in the Application
Additional Information field).
If the recovery group is providing service, its every UNLOCKED recovery
unit that has the ACTIVE role, has the ENABLED operational state and an
empty procedural status.
For example, the state of recovery units of the /Directory recovery groups
can be checked as follows:
$ fshascli --state $ (fshascli -children /Directory |
grep -vE "\/.+\/.+\/" )
/CLA-0/FSDirectoryServer:
administrative (UNLOCKED)
operational (ENABLED)
usage (IDLE)
procedural (NOTINITIALIZED)
availability ()
unknown (FALSE)
alarm ()
role (COLDSTANDBY)
/CLA-1/FSDirectoryServer:
administrative (UNLOCKED)
operational (ENABLED)
usage (ACTIVE)
procedural ()
availability ()
unknown (FALSE)
alarm ()

24 (26)

# Nokia Corporation

DN70155942
Issue 1-0 en draft

70256 RESOURCE ALLOCATION OR DE-ALLOCATION FAILURE

role (ACTIVE)

In the above case, the recovery unit of the CLA-0 node is acting as a cold
standby backup and the recovery unit on CLA-1 is running the service
normally.
Note that the grep command in the example is used to filter out
information regarding individual processes in each recovery unit. Since
this is a situation that may be caused by various different faults, contact
your Nokia representative to analyse the root cause.
Clearing

Clear the alarm manually after the problem has been solved.
Testing instructions

Simulate an IP address allocation failure
1.

An IP address allocation failure can be caused by manually allocating an IP
address to a node before a recovery unit is started. Select a cold active/
standby recovery group (but do not use the Directory recovery group) that
has an IP address associated with it, and allocate the address to the standby
node. For example:
$ fshascli --state /CLA-0/FSClusterDNSServer
/CLA-0/FSClusterDNSServer
administrative (UNLOCKED)
<== Unlocked
operational (ENABLED)
<== Operational
usage (IDLE)
procedural (NOTINITIALIZED)
availability ()
unknown (FALSE)
alarm ()
role (COLDSTANDBY)
$ grep ClusterDNS /etc/hosts
192.168.2.255 ClusterDNS
. . .
$ ip addr show | grep 192.168.2.255
inet 192.168.2.255/23 scope global secondary bond0
inet fe80::192:168:2:255/10 scope link
$ ssh cla-0
Last login: . . .
$ ip address add 192.168.2.255/23 dev bond0

2.

Issue a switchover for the recovery group so that the service attempts to
move to the node that already has the IP address. For example:
$ fshascli --switchover /ClusterDNS

The switchover fails and the alarm gets raised. The alarm is visible, for
example, in the alarm log. Note that you have to cancel the alarm manually.

DN70155942
Issue 1-0 en draft

# Nokia Corporation

25 (26)

FlexiPlatform Alarms for RNC-OMS

3.

Remove the IP address that you added manually or reboot the node. For
example:
$ ip address del 192.168.2.255/23 dev bond0