THE SOLUTION PROVIDERS

Design and manufacture manufacture of

STORAGE TANKS FOR ALL PURPOSES

Contents  Aboveground Enclosed Bunded Storage Tanks Tanks Envirotank Rectangular T64 Range - Envirotank Cylindrical T34 Range - Envirotank Rectangular With Removable Pitched Roof  Bio Envirotank  Belowground Double Skin Storage Tanks Tanks Envirotank Cylindrical

Underground  Vertical  Ve rtical LubeOil Rectangular Bio Fuel Storage Enviro Horizontal  Aboveground  Abovegr ound Specialist Open Top Chemical

tanks tanks tanks tanks tanks tanks tanks tanks tanks tanks tanks

4 5 6 7 8-9

10-11

Other Enclosed Bunded Storage Tanks Tanks Gravity Feed Envirotank Rectangular  Autolube Envirotank Envirotank Rectangular

12 13

Open Bunded Storage Tanks Cylindrical Rectangular

14 15

 Vertical Storage Tanks Tanks Open Bunded Cylindrical Tanks Cylindrical Single Skinned Tanks (Type D on legs/skirt) Cylindrical Single Skinned Tanks (Type G flat bottom) V2 Range - Cylindrical Enclosed Bunded Storage

16 17 18 19

Horizontal Tanks Cylindrical Single Skin Storage Tanks Rectangular Single Skin Storage Tanks

20 21

Other Tanks Specialist Tanks Galvanised Open Top Galvanised Bolted Top

22 23 24

 Accessories Ladders (Galvanised) Holding Down Straps Typical Connections Support Cradles Mild Steel Fuel Tank Components Pumps & Controls

25 25 25 26 27 28

Other Information  Volumes,  Volum es, Surface Areas & Conversion Tables Tables C.A.D & Manufacturing Suitable Storage Products

29 30 31

Complete Liquid Storage Solutions

Joseph Ash was born in 1824, the son of a Birmingham Chemist. He founded his company in 1857 which took an active part in the expansion of the Midlands. In 1864 he joined John Pierce Lacy to form  Ash & Lacy. At the start of the new millennium Ash &  Lacy were taken over by Hill & Smith Holdings Plc, now the Parent Company. JA Envirotanks is a trading name within Joseph Ash Ltd specialising in the mass production of aboveground enclosed bunded steel tanks and buried double skinned steel tanks. The company has occupied its current site for over 150 years, always specialising in tank production with high capacity cranes and specialist welding equipment technology.

More bespoke tanks and fabrications are produced on site from carbon steels and stainless steels which include conical hoppers, chemical and process tanks with specialised linings and ladders, platforms, stairways and frames. All steelwork is galvanised by the sister company Joseph Ash Galvanising. Joseph  Ash is also one of the l argest galvanising operations in Europe which includes many galvanising plants within the UK. The patented “ENVIROTANK” product range is manufactured in Birmingham which includes enclosed bunded rectangular and cylindrical tanks which comply with The Control of Pollution Regulations and are licensed to OFTEC standard OFS T200. JA Envirotanks products are suitable for all fuels including specially engineered tanks for the storage of the latest formulated bio fuels with heaters and specialist coatings. JA Envirotanks produce tanks with a designed life of 20 years to meet the needs of aggressive commercial and industrial environments. Located at the hub of the UK motorway network JA  Envirotanks can despatch, deliver and offload at any mainland location or port.

  s    k   n   a    T   e   g   a   r   o    t    S    d   e    d   n   u    B    d   e   s   o    l   c   n    E    d   n   u   o   r   g   e   v   o    b    A

 Aboveground Enclosed Bunded Storage Tanks The ENVIROTANK is a primary storage tank, externally encased within an outer weatherproof bund to ensure any leakage or nominal overfill situation is safely contained. The ENVIROTANK is easily transportable as a one-piece unit and reduces costly and time consuming site work. The ENVIROTANK is delivered by JA Envirotanks transport to the customers premises. If at a later date a new site for the ENVIROTANK is required it only has to be emptied of contents, cleaned internally, uplifted and transported to its new location. Outer bund designed to contain 110% of the inner tank volume. Inner tank manufactured to BS799 Part 5 from Steel plate to BS EN 10 025:2004:S275. Compliance with the control of pollution regulations. Inner tank and outer bund pressure tested.

Envirotank Rectangular Ref

Capacity Litres

(Excl cabinet) mm

Length

Width mm

Height mm

Weight

E61A

2273

1753

1190

1220

1118

E62A

2727

2104

1190

1220

1270

E63

2841

2192

1190

1220

1296

E64

2954

2274

1190

1220

1348

E65

3409

2631

1190

1220

1500

 

(Approx) Kg

E66

3636

2806

1190

1220

1576

E67A

4546

3080

1470

1220

1800

E70

5682

3845

1470

1220

2102

E71A

6819

3745

1470

1500

2408

E72

7955

2704

1800

1830

2510

E74A

9091

3035

2408

1500

2816

E75A

11364

3790

2408

1500

3278

E76A

13637

4540

2408

1500

3854

E78

18183

3696

3008

1830

4486

E79

22729

4610

3008

1830

5506

E80

27275

5532

3008

1830

6102

E81

31821

6454

3008

1830

6694

E82

36367

7376

3008

1830

7550

E83

40913

8298

3008

1830

8282

E84

45459

9220

3008

1830

9524

E85

54550

11064

3008

1830

10150

E60

80000

10261

3008

3048

14000

E99

90000

11545

3008

3048

15479

E86

100000

12830

3008

3048

16918

E99

110000

11780

3008

3650

17905

E87

120000

12870

3008

3650

19295

E88

140000

12500

3618

3650

22445

E89

180000

14850

3960

3600

27000

 Advantages The ENVIROTANK SAFE is an inner storage tank, externally encased within an outer weatherproof bund to ensure any leakage or nominal overfill situation is safely contained. The top connections, pipework and manway are enclosed by a secondary roof section for total security. The ENVIROTANK SAFE is easily transportable as a one-piece unit and reduces costly and time consuming site work. The ENVIROTANK SAFE is delivered by JA Envirotanks transport to the customers premises. If at a later date a new site for the ENVIROTANK SAFE is required it has only to be emptied of contents, cleaned internally, uplifted and transported to its new location. Outer bund designed to contain 110% of the inner tank volume, manufactured to BS799 Part 5 from Steel plate to BS EN 10 025:2004:S275. Compliance with the control of pollution regulations. Inner tank and outer bund pressure tested.

• • • • • • • • • • •

Enclosed bunded tank Space saving (smaller footprint) Reduced maintenance costs Weatherproof (Tank & Bund Enclosed) Cuts costly site work Needs only suitable level hard standing Overfilled product can be re-used Easily transportable Sizes/capacity to suit most situations Finished in green or black oil resistant paint Clients own in-house colours can be accommodated on request • Offloading and positioning facilities available if required • The optional security cabinet will extend the overall length of the unit by 750mm.

 Additional Fittings Padlockable access hatch

• 50, 65 or 80mm fill pipe c/w valves, tanker coupling and cap • Venting assembly sized to suit • Sludge drain pipe • 40mm outlet pipe with valve

450mm

• Electric bund monitoring with alarm • Contents guage in litres • Overfill alarm and/or overfill prevention valve • Dipstick, dip pipe, cap and chain

1,830mm

• Dispensing pumps with safety break couplings and automatic nozzle (3m hose supplied) • Fuel monitoring systems • Optional galvanised ladder and platform • Optional distribution board and lighting • Optional security cabinet with aluminium roller shutter door and steel doors.

Padlockable steel doors

Envirotank Safe Ref

Benefits Enclosed Bunded Storage Tank with Secondary Removable Pitched Roof for Total security 

Capacity Litres

Length mm

Width mm

Height mm

Weight

S30

2000

1180

1100

1830

1136

S31

3000

1660

1180

1830

1344

S32

5000

2170

1485

1830

1954

S33

7000

2520

1790

1830

2448

S34

10000

3590

1790

1830

3171

S35

15000

4020

2398

1830

4195

S36

20000

5360

2398

1830

5267

S37

25000

6700

2398

1830

6326

S38

30000

6410

3008

1830

7102

S39

40000

8550

3008

1830

9075

S40

50000

10690

3008

1830

10876

S41

60000

10660

3618

1830

11825

S42

70000

12440

3618

1830

14201

S43

80000

14220

3618

1830

16023

 

(Approx) Kg

UK Patent No: 2 251 021

  s    k   n   a    T   e   g   a   r   o    t    S    d   e    d   n   u    B    d   e   s   o    l   c   n    E    d   n   u   o   r   g   e   v   o    b    A

   k   n   a    t   o   r    i   v   n    E     o    i    B    d   n   u   o   r   g   e   v   o    b    A

Bio-Envirotank  Rectangular Aboveground Enclosed Bunded Storage  Tanks (Inner tank externally   stiffened and with a sloping  hopper style bottom)  A unique design (“Pat App 2 477 266”) comprising a primary storage tank without internal structure to enable ease of internal inspection and cleaning. The base of the tank has a sloping hopper style bottom to a sump, the sump being serviced by a 25mm sludge drain pipe accessible from the tank top.

Design for the Future With developing Bio-fuels water content and bacterial growth is becoming more of an issue in tanks; regular tank cleaning and inspections are now necessary. Entering tanks presents health and safety concerns and by constructing a tank with free internal space (no cross stays) makes entry and egress easier and safer. Access and retrieval of remotely controlled cleaning technologies (non man entry systems) is also more practical with Bio-Envirotanks. The incorporation of sloping bases and sumps helps reduce the frequency of cleaning as water and contaminants will easily drain into the sump. Residues are extracted via the sludge drain pipe which runs from the tank top to the sump.

The concept with correctly positioned manway inspection points allows tank cleaning without man entry reducing the need for confined space entry health and safety procedures. The primary tank is enclosed by an outer steel bund that fully complies with the control of pollution regulations, the bund holding the inner tank capacity plus 10% (110% containment). The tank can be split into compartments for gas oil/diesel/oils/Adblu and process liquids. Internal tank linings can easily be applied due to the unrestrictive internal tank construction. External manways and connections are enclosed within a steel secure hatch which is padlockable to prevent tampering. End or side mounted security cabinets can be fitted including steel or roller shutter doors and integral spillage trays, to house pipework, pumps, gauging, alarms and controls. Designed life 20 years. Inner tank and outer bund pressure tested.

Bio-Envirotank  Ref

Capacity Litres

Length mm

Width mm

Height mm

Weight  

(Approx) Kg

BE1

2500

1410

1460

2000

1372

BE2

5000

2610

1460

2000

2202

BE3

7500

3760

1460

2000

2937

BE4

10000

3310

2010

2000

3306

BE5

15000

5080

2010

2000

4680

BE6

20000

5560

2410

2000

5557

BE7

30000

6740

2410

2400

7372

BE8

40000

7164

3030

2400

9025

BE9

50000

8864

3030

2400

10839

BE10

70000

9626

3008

3048

15702

BE11

90000

12276

3008

3048

19438

BE12

120000

15476

3160

3048

24249

BE13

140000

16076

3160

3400

26484

BE14

180000

17905

3600

3400

30700

Features Heating Low pressure hot water and steam coils can be built into the tank bottom if needed or electrically powered submersion heaters.  All heating can be provided with temperature sensors and control thermostats. Lagging and cladding can be added to the outside of the unit for heating efficiency.

Gauging • • • •

Hydrostatic gauges in litres Electronic gauges in litres Differential and level measurement systems for closed vent tanks Water monitor indicators are available with electronic gauges

• • • • • • • • • • • •

Electrical Lighting, wiring and distribution boards with isolators to suit equipment fitted.

Heating Options • • • •

• • • •

Low pressure hot water coils Steam coils Immersion/submersion heaters Lagging and cladding to minimise heat losses



Enclosed bunded tank design Reduced maintenance costs Needs only suitable level hardstanding for siting Easily transportable Lifting eyes for offloading Overfilled product can be reused Fill pipe sizes 50mm/65mm/80mm complete with isolation valve Tanker coupling and cap and chain Venting systems to suit fill size 25mm desludge pipe to sump 50mm outlet pipe for gravity feed or top suction 50mm and 80mm overfill prevention valves available to shut off the tanker fill when the primary tank reaches capacity Electronic low level and overfill alarm units Electronic bund warning alarm units Transfer pump sets available to feed boilers and generators Dispensing pumps available with automatic nozzles Fuel monitoring systems fitted to suit customer needs.

Cabinets • Side cabinets and end cabinets • Roller shutter doors or steel hinged doors

 Access • • • •

 Vertical caged ladders and walkways Ships ladder and walkways Stairway to walkway  All galvanised finish with open mesh or chequer plate flooring

Lockable security hatch over manway and critical connections

Ladder & walkway (optional)

Overflow prevention device

Internal desludge pipe to sump

Cabinet with aluminium roller shutter door (optional)

Outer Bund

Specialist Features

(optional)

Gauge

Fill Pipe Inner tank with hopper base to sump

 Alarm Panel 450mm diameter sump Internal suction pipe Universal beam bearers

Pumping options

• 50mm/65mm/80mm vent dryers to minimise moisture and condensation • Internal linings to keep fuel sterile and prevent corrosion • Stainless steel pipework and fittings. • Specialist filters including magnetic filter  technology in order to reduce bacteria in the tank bottom. Optional Bolt on Pitched Roof to  secure all Top Pipework & Tank Entries

   k   n   a    t   o   r    i   v   n    E     o    i    B    d   n   u   o   r   g   e   v   o    b    A

  s    k   n   a    T   e   g   a   r   o    t    S    d   e    d   n   u    B    l   a   c    i   r    d   n    i    l   y    C    l   a   c    i    t   r   e    V

 Vertical Bunded Cylindrical Tanks • One coat of zinc phosphate primer, one coat of green oil resistant paint • Inner tank manufactured generally to BS 799 Part 5 Type G • Side manway available on inner tank only • Screwed or Flanged connections available • Pipe work fitted to suit application • Compliance with CoP regulations • Outer bund to contain the capacity of the inner tank plus 10% •  Access ladders, platforms, steelwork &  periphery hand railing available

Non return valve fitted

• Inner tank pressure tested • Bund tested sound.

Lift lugs

Ref

Inner Tank (DiaxH)mm

No of Tanks

Capacity Litres

B61

1500 x 1545

1

2270

1981 x 1981 x 686

B62

1500 x 2895

1

4545

1981 x 1981 x 1390

B64

1900 x 3590

1

9120

2438 x 2438 x 1775

B65

2486 x 2905

1

11364

2935 x 2935 x 1524

B66

2486 x 3400

1

13638

2935 x 2935 x 1828

B67

2743 x 3352

1

18183

3200 x 3200 x 1981

B68

3000 x 3505

1

22730

3657 x 3505 x 1981

 

Bund Size (LxWxH)mm

 All the above tanks are transported as one piece units (B61-B68)

 Additional Fittings • 50mm/65mm/80mm diameter fill pipe with valve and brass cap • Vent complete with bird guard • 25mm diameter sludge complete with valve and plug • 40mm diameter draw off complete with valve • Hydrostatic contents gauge complete with capillary tube and bracketed to the

B69

2743 x 5029

1

27275

4114 x 3656 x 1981

B70

2743 x 6477

1

36368

3810 x 3656 x 2896

B71

2743 x 8051

1

45450

4724 x 3656 x 2896

B72

2743 x 9753

1

54551

5638 x 3656 x 2896

B73

3000 x 10261

1

68189

5638 x 3656 x 3656

B74

2743 x 6477

2

72735

7010 x 3656 x 1981

B75

2743 x 8051

2

90919

8382 x 3656 x 1981

B76

2743 x 9753

2

109103

9753 x 3656 x 1981

B77

3000 x 10261

2

136379

12115 x 3656 x 1981

B78

3000 x 11227

2

150000

12115 x 3656 x 2200

 All the above tanks are transported as seperate units to be bolted together at site (B69-B77)

Tank and Bund from 6mm thick mild steel plate

 Vertical Single Skin Cylindrical Storage Tanks

  s    k   n   a    T   e   g   a   r   o    t    S   n    i    k    S   e    l   g   n    i    S    l   a   c    i   r    d   n    i    l   y    C    l   a   c    i    t   r   e    V

• Manufactured in accordance with BS 799: Part 5: Type D •  All welded seams • Certified tested • Fitted with 600mm dia. Manhole with set pinned cover and gasket • Standard connections include two 65mm, one 40mm and one 25mm screwed sockets (flanged connections optional) • Finished one coat of primer/gloss finish, or to customer’s requirements • Steel plate to BS EN 10 025: 2004: S275 •  Access ladders, platforms, steelwork &  periphery hand railing available.

Type D Ref

Mounted on Steel Skirt

Mounted on Legs

Capacity Litres

Height metres

Internal Dia metres

Shell Thk mm  

Weight

 V01

2273

1.528

1.494

6

460

 V02

2841

1.867

1.494

6

530

 V03

3409

2.207

1.494

6

630

 V04

4546

2.889

1.494

6

790

 V05

5682

3.569

1.494

6

960

 V08

9092

3.547

1.900

6

1230

 V10

11365

4.389

1.900

6

1480

 V13

13638

5.230

1.900

6

1750

 V15

18184

4.320

2.486

6

1970

 V17

22730

5.303

2.486

6

2370

 V20

27275

6.286

2.486

6

2780

 V21

31821

7.270

2.486

6

2860

 V22

36367

8.253

2.486

6

3350

 V23

40913

6.600

2.986

6

3690

 V24

45459

7.281

2.986

6

3950

 V25

54551

8.390

2.986

6

4720

 V26

68189

10.262

2.986

6

5430

 V27

90918

13.654

2.986

6

6850

 V28

100010

14.935

2.986

6

7044

 V29

113647

16.926

2.986

6

7924

 V30

136377

11.735

4.000

8

11500

(Approx) Kg

  s    k   n   a    T   e   g   a   r   o    t    S    d   e   m   o    t    t   o    B    t   a    l    F    l   a   c    i   r    d   n    i    l   y    C    l   a   c    i    t   r   e    V

 Vertical Single Skin Flat Bottomed Cylindrical Storage Tanks • Manufactured in accordance with BS 799: Part 5: Type G or BS EN 14015

Dished Top BS 799 Pt5 Type G

•  All welded seams • Certified tested

Lifting lugs

• Fitted with 600mm dia. Manhole with set pinned cover and gasket • Standard connections include two 65mm, one 40mm and one 25mm screwed sockets • Finished one coat of primer/gloss finish, or to customer’s requirements • Steel plate to BS EN 10 025: 2004: S275.

High load DPC membrane recommended between tank base &  concrete foundation

Conical Top BS EN 14015

Flat Bottom

Type G Ref

Capacity Litres

Height metres

Internal Dia metres

Shell Thk mm

Base Thk mm  

Weight

 V01

2273

1.528

1.494

6

6

460

 V02

2841

1.867

1.494

6

6

530

 V03

3409

2.207

1.494

6

6

630

 V04

4546

2.889

1.494

6

6

790

 V05

5682

3.569

1.494

6

6

960

 V08

9092

3.547

1.900

6

6

1230

 V10

11365

4.389

1.900

6

6

1480

 V13

13638

5.230

1.900

6

6

1750

 V15

18184

4.320

2.486

6

8

1970

 V17

22730

5.303

2.486

6

8

2370

 V20

27275

6.286

2.486

6

8

2780

 V21

31821

7.270

2.486

6

8

2860

 V22

36367

8.253

2.486

6

8

3350

 V23

40913

6.600

2.986

6

10

3690

 V24

45459

7.281

2.986

6

10

3950

 V25

54551

8.390

2.986

6

10

4720

 V26

68189

10.262

2.986

6

10

5430

 V27

90918

13.654

2.986

6

10

6850

(Approx) Kg

C.A.D and Manufacturing • J A Envirotanks have several CAD workstations & all drawings are produced in electronic format (PDF, DWG & DXF). •  All our storage tanks designs are carried out using Autocad software.

  g   n    i   r   u    t   c   a    f   u   n   a    M    &    D  .    A  .    C

• 3D solid modelling utilises our  Autocad Inventor workstation. • JA technicians are able to create bespoke tank designs to suit specific applications.

Certain liquids may also be stored adequately in unlined carbon steel tanks – please consult our Sales Office.

Liquids

for storage in carbon steel internally coated Tanks  A   Aliphatic Hydrocarbons  Alkanes  Ammonia Aqueous Solution 5%  Ammonia Aqueous Solution 10%  Ammonia Aqueous Solution 20%  Ammonia Aqueous Solution 40%  Ammonium Carbonate Aqueous Sol. 5%  Ammonium Carbonate Aqueous Sol. 10%  Ammonium Carbonate Aqueous Sol. 25%  Ammonium Nitrate (all strengths) N-Amyl Acetate  Animal Oils and Fats  Aromasol H  Aromatic Hydrocarbons (not Benzene)  Aromatic Solvents (Petroleum)  Aviation Fuel B Benzine Bio Fuels Butanol-iso Butanol-normal Butyl Methacrylate C Calcium Chloride 10% Calcium Chloride 25% Calcium Chloride Saturated Calcium Hydroxide Carbon Tetachloride Cashew Nut Oil (20oC) Castor oil (up to 20oC) Caustic Soda sol. 5%, 10%, 25%, 50% China Wood Oil (up to 40oC) Citric Acid 10% Cod Liver Oil (up to 20oC) Cotton Seed Oil (up to 20oC) Crude Oil (high and low sulphur) Cumeme Cyclohexane Cyclohexanol P-Cymene D Decanol Diacetone Alcohol Dibutyl Phthalate Dicyclopentadiene Diesel Oil Diethanolamine Diethylene Glycol Di-2-(ethyl Hexyl) Phthalate Di-Isobutylene Di-iso Butyl Ketone Di-iso-octyl Phthalate Di-n-butyl Phthalate Dipentene Dodencane Dutrex E Engine Oils Ess Aviation o12 12o Esso (base) Light A Special Esso Medium Base Esso Base Light A  Ethyl Benzene Ethylene Glycol 2-Ethyl Hexanol F Fats Animal Ferric Chloride (all strengths) Fuel Oil G Gamlen Tank Cleaning Oils

Gasoline Premium (Europe) Gasoline Regular (Europe) Gasoline Premium (Canada) Gasoline Regular (Canada) Gas Oil (2) (Europe) Glycerine Glycerol Grain Groundnut Oil A.V.10 H Heating Oil No.2 (Canada) Heavy Aromatic Naphtha Heptane-normal Hexane-normal Hexylene Glycol High Aromatic White Spirit Hydraulic Oil Hydrocarbon Aliphatic I Isobutanol Iso Dodecane Iso Octanol Iso Octyl Alcohol Isopentane Isoprene J Jet Fuel JP4 Jet Fuel A-1 K  Kaydol Heavy Duty White Kerosene Kontol A.162 L Lanoline Lard Linseed Oil Lube Oil Lube Oil Additive Lubricating Oil M Magnesium Chloride Magnesium Chloride Magnesium Chloride Magnesium Chloride Mineral Oils Mineral Spirit

5% 10% 25% Saturated

N Naphtha Naphtha Coal Tar Naphtha Heavy Naphtha Petroleum Naphthenic Acid Nonanol Nonylphenol Nonyl Heptane Nonyl Hexane Nonyl Butanol Nonyl Butyl Alcohol Nonyl Pentane Nuoplaz O Octane-iso Octanol-iso Octyl Phenol Ethylene Oxide Oils Animal Oils Mineral Oils Vegetable Oiticia Oil (up to 20oC)  A.V.5 Oleum Olive Oil  A.V.10

P Palm Oil (up to 40oC)  A.V.10 Palm Kernel Oil A.V.5 Paraffin Paraffin Wax Para Xylene Peanut Oil A.V.10 Pentane-n Pentane-iso Perilla Oil (up to 20oC)  A.V.10 Petrol Petroleum Solvents Aliphatic Petroluem Solvents Aromatic Phthalate Plasticisers Pine Oil Polypropylene Glycol Poppy Seed Oil (up to 20oC) A.V.10 Potassium Hydroxide (up to 50%) Propylene Glycol S Sea Water Shell Oil 1984 Shellsol A  Shellsol E Shellsol T Shellsol AB Shellsol N Shellsol R Soap Solution Sodium Carbonate (all strengths) Sodium Chloride Solution (all strengths) Sodium Dichromate Solution (up to 25%) Sodium Hydroxide (up to 50%) Sodium Hypochlorite (up to 25%) Sodium Nitrate Solutions (all strengths) Solvent Naphtha Solvesso 100 Solvesso 150 Soya Bean Oil A.V.10 Sperm Oil Sunflower Seed Oil (up to 20oC)  A.V.5 T Tallow (acid number not greater than 5) Teepol Tetrahydronaphthalene Titanium Tetrachloride Toluene Trichlorethane Triethylene Glycol Triton X100 Triphenyl Phosphate 2.2.4 Trimethyl Pentane Tung Oil Turpentine Turpentine Substitute W Water Ballast Water Sea Whale Oil (up to 20%) White Spirit White Spirit Aromatic White Spirit Low  Aromatic White Spirit High Flash  X   Xylol  Xylene Industrial (mixed isomers) Z Z.D.D.P (Zinc Dialykl Dithiophosphate)

  s    d    i   u   q    i    L   e   g   a   r   o    t    S    l   a   c    i   p   y    T

Main Switchboarrd

0121 622 4661

Generall Sales

0121 666 4778 0121 666 4774 0121 666 4787

Drawing Office

0121 666 4779

Sales Office Hours Monday to Thursday

Friday

8:45am - 1:00pm 2:00pm - 5:00pm 8:45am - 1:00pm 1:30pm - 4:1 15pm

E

[email protected] 

W

www.jaenvirotanks.com

PO Box x 16,, Charles s Henry Str treet,, Birmingham, B12 2 0SP

Sponsor Documents

Or use your account on DocShare.tips

Hide

Forgot your password?

Or register your new account on DocShare.tips

Hide

Lost your password? Please enter your email address. You will receive a link to create a new password.

Back to log-in

Close