Area Name Date DOC. REF. Cat. No. Lamps per Luminaire Total Lumens per Luminaire (TL)
4/24/2013 2040 FBH145 1
14 CFL 0.71 1 568
Room Data : Length (L) Width (W) Area (A) CAVITY REFLECTANCES Ceiling 0.5 Walls 0.5 Floor 0.2 4 3 12 M M M2 Ceiling Activity ROOM ACTIVITY Working Plane h= Floor Cavity
FC
h=
cc
0.2 2.05
RC
h=
0.8
Room Index =
LxW h rc x (L+W) = IL x A TL x UF x LLD x LDD
=
12 14.35 0.44
= 0.836237
Utilization Factor (UF) Req. Luminaires =
=
3600 177.4432
= 20.28818
No. of Luminaires Installed (NL) =
20
Calculation Procedure: 1. Determine Required illumination and select light sources and luminiraires 2. Compute Room Index and utilization factor *Room Index=(LengthxWidth)/(effective height x (length + width) 3. Calculate maintenance factor *MF=LLD x LDD 4. Find Required number of luminaires *N= (illumination Required x Area)/(MF x UF x Lamp Lumens)
Calculation Reference:Society of Light and Lighting (2002). Code for Lighting (CIBSE). Publisher, ButterWorth-Heinmann