LPG Cylinder Regulation and Security System
ABSTRACT
In today’s world the LPG cylinder plays a vital role not only for domestic but also use in
industries, hospital, automobiles, educational sector (school and colleges using LPG cylinders for
laboratory purpose) and public sector.
It is panic that these cylinders get empty without any intimation. In these days where the
refilling is not an easy task, these cylinders get empty at unexpected situation.
Another major problem is the leakage of LPG which may to lead bursts resulting in
heavy loss of life and wealth. Hence the project outlays the protection systems from hazards due
to LPG leakage and fire, using special components like gas sensor and temperature sensor.
Each and every individual wants to be secured, Hence the security system has to be
managed in the kitchen and the entire place where LPG is used. Unfortunately none of existing
security systems have all the attributes i.e. leak detection, fire detection, weight detection along
with protection and alarm.
This project is aimed at providing indication of gas content remaining in the LPG
cylinder while it is in use so that it is helpful to the user to place the order for the new cylinder at
an appropriate time and cylinder refill alert message is sent to the users mobile numbers. The
security system incorporated consists of leak detection and fire detection unit along with alarm
unit. Further on detecting leak, the signal is transferred to GSM and the Microcontroller sends
signal to the solenoid valve to cut off the further gas supply. Simultaneous GSM switches off the
A.C mains of the kitchen and sends the alert message to the users mobile numbers and also
makes the alert calls to the users mobile numbers until they are attended at regular. In this way
“LPG cylinder regulation and security system” provides a complete security for LPG cylinder
users.

Introduction:
LPG is the abbreviation or short form for liquefied petroleum gas. Like all fules,fossile it is a
non-renewable energy source. It is extracted from crude oil and natural gas.The main
composition of LPG is hydrocarbons. The main components of the LPG are propane, butane.
As we all know the hazards due to LPG is increasing day by day. The hazards are such as
explosion, blast. The hazards may be due to gas leakage, fire occurance. We all know every
human being wants to be secured with these hazards. The life of an each individual is very
precious. So in order to avoid such hazards due to LPG leakage, fire occurring. Hence we need to
provide security system to the LPG.
Now a days the use of LPG or the requirement of LPG is increasing day by day. In every field
the use of LPG is there such as in vehicles, kitchen, hospital, industries etc. So the regulation of
LPG is essentially required. In order to regulate the LPG the wastage or leakage of LPG should
be reduced. If the leakage or wastage of LPG is increased, in future use we may not get it.
Hence the regulation of LPG is required.

Block Diagram of LPG Cylinder Regulation and security System
DOORS AND
WINDOWS

LPG
Cylinder
Off
signal

Leakage sensing
unit

GSM

Solenoid
valve

Fire sensing
unit

Microcontroll
er

Buzzer unit

Weight detecting
unit

THEFT
DETECTION
UNIT

AC mains
off

Display

Leakage sensing unit: It is gas leakage sensing unit. The LPG sensors used are type MQ6
and are capable of detecting presence LPG gas in air. When gas leakage above the set values
(600 PPM) it gives signal to the microcontroller (MC).

Fire sensing unit: The temperature sensor used is a semiconductor type analogue
temperature sensor capable of sensing -55 to +150 degree centigrade’s and providing output in
analogue voltage form. The sensor type used is LM35. Whenever temperature rises above the
specified value this unit gives control signal to the MC. The set temperature for this project is 70
degree

Weight detecting unit: The load cell amplifier and AD convertor is used to measure LPG
cylinder weight with the LPG weight. This is used to provide user with an alert in case the LPG

level goes below the set level. When this situation occurs weight detecting unit gives signal to
MC.

Microcontroller: This is the controlling unit. It takes the signal from sensing and detecting
units and gives controlling signal to the solenoid valve, Buzzer unit, Display, GSM and AC
mains off circuit. And then following sequence of operation will take place.
i) Buzzer start beeping
ii) Closing of solenoid valve
iii) Turns off the AC Mains
iv) Sends alerts to the user’s mobile number.

Solenoid valve: This unit consists of a Solenoid valve for controlling LPG supply to source.
When leakage detected solenoid valve receive signal from MC. When it receives the signal the
coil inside the valve get energies and attracts the knob. Like this valve get close and cut off
further gas supply to the burner. When amount of gas leakage and temperature comes below the
specified valve, the coil de-energies and releases the knob, and valve opens and then allows the
gas to burner

Buzzer unit: This unit has an audio annunciation unit generally called as Piezo buzzer which
beeps in case of LPG leakage or Fire alerts. It receives the signal from MC, when leakage or fire
detected.

Display: This consists of 16 characters and 2 lines type JHD162A Display. It continuously
displays the weight of the gas and status of the sensors. It also signal from MC.

AC mains off: When leakage or fire detected MC sends signal to AC mains off unit. This unit
has relay circuit for cut off the AC mains of the kitchen. when leakage or fire detected, It
receives signal from MC and relay coil get de-energies then opens the NO contacts. The AC
Mains of the kitchen is connected to NO hence it cut off automatically. When amount of gas
leakage and temperature comes below the specified valve, the coil energies and closes the NO
contacts hence AC Mains is get switch on automatically

GSM (Global system for mobile communication): This system receives the signal
from MC and sends information (alerts, status of the units) to the user’s mobile number.

Flow chart of the working of this system
START

Turn off LPG
valve
LPG/FIRE ALERT?
YES
NO

INITIALIZE
GSM
MODEM

TURN OFF LPG
VALVE &MAINS
SUPPLY
SEND LPG/FIRE
ALERT AFTER

ENABLE LPG
VALVE
YES

LPG LOW?

NO

SEND LPG
LOW
ALERT

LPG/FIRE ALERT?
SEND LPG/FIRE
ALERT

YES
NO
CHECK& PROCESS
MESSAGE

At the begging MC checks LPG/Fire Alert. If it is yes then turn off the valve and AC Mains then
sends the LPG/FIRE alert after GSM initialize. If it is not so gives command to the GSM
initialize and then enables the valve. After that checks the level of the LPG. If it is below the
specified value sends the LPG low Alert. If it is above the specified value checks the LPG/Fire
Alert. Like this MC continuously checks the all conditions

Result and Discussion:
i)

ii)

iii)

If the load on the load cell is less than the set value of gas(minimum gas in Kg), then
GSM sends refill alert message to the user’s mobile numbers. MC monitors
continuously and displays the actual weight of the gas on the LCD.
When the gas leak starts, gas sensor (MQ-6) output changes. Output depends upon
the amount of gas leakage.
a) Buzzer starts beeping and the solenoid valve is closed and further gas supply
to the burner is stopped. The closing of solenoid is indicated by LED
b) MC sets the signal at the input of encoder and transmits the signal by using
RF signal. Receiver receives these signals and decoder decodes the signals.
Decoder activates the relay (MCB) by using NAND gate and transistor and
turns off the AC mains.
c) GSM sends the leakage alert (messages) to user’s mobile numbers.
d) GSM Calls to the user’s mobile numbers. And calls continuously if the user
not attend the call
In case of Fire_ _ _ _ (Not only due to LPG but also due to other reasons)
When the temperature rise above the 70.c (It is the set value of temp .We can set it for
any value in between 0 to 150.c because temp sensor (LM35) can sense up to150.c)
a) Buzzer starts beeping and the solenoid valve is closed and further gas supply
to the burner is stopped.
b) MC set signal at the input of encoder and encoder transmits the single by
using RF single. Receiver receives these signals and decoder decodes the
signal. Decoder activates the relay
(MCB) by using NAND gate and transistor and turns off the AC mains
c) GSM sends leakage alert (messages) to user’s mobile numbers.
d) GSM calls to the user’s mobile numbers and calls continuously if the user not
attends the call.

FUTURE SCOPE

i)
ii)

We can turn on the exhaust fan.
Automatic opening and closing of widow.

CONCLUSION
In today’s world the LPG cylinder plays a vital role not only for domestic but also use in
industries, hospital, automobiles, educational sector (school and colleges using LPG cylinders for
laboratory purpose) and public sector , like this LPG cylinders become part and partial of
human’s life. As the popularity of the LPG cylinders increases, hazards due to LPG also increase.
There is no salutation for these hazards. And one more very important problem with LPG is that
get empty without giving any information to the users. So it is very essential to avoid these
problems. These problems are rectified by this project.