VRLA Rechargeable Battery

MSU-200

Measures

Technology

Values

Innovation

(MSU-200FR)

(2V, 200Ah)

FEATURES
Sealed structure, no electrolyte leakage or spill.
High performance alloy to secure corrosion-proof feature.
Unique electrolyte system achieves maximum service life.
Special paste formula promotes the good charging acceptance.
Electrolyte with gel technology.
15 years design life floating charging.

APPLICATION
Central Office
Energy Storage Systems

UPS
Telecom

SPECIFICATIONS
Nominal Voltage

2V
10 Hour Rate F.V.(1.80V/cell)
3 Hour Rate F.V.(1.80V/cell)
1 Hour Rate F.V.(1.75V/cell)

Nominal Capacity(25oC)
Approx. Weight
Terminals
Max. Discharge Current
Max. Charge Current

200 Ah
150 Ah
110 Ah

ISO 9001

13.5Kg(29.8lbs.)
B6 (Fitting M8 bolt & nut) I3 is optional
900 A (5 sec.)
Charge
Discharge
Storage

Operating Temperature
Range

ISO14001

50 A
0oC~40oC(32oF~104oF)
-20oC~50oC(-4oF~122oF)
-20oC~40oC(-4oF~104oF)

UL
IEC60896-21/22
JIS C 8704-2
GB/T19638.2
YD/T799

< 3% per month (25oC)

Self Discharge
Internal Resistance
Container Material

1.0m

(Fully Charged )

ABS(UL94-HB, UL94-V0 is optional)

OUTER DIMENSIONS

mm(inch)

Length (L)
Width (W)
Container Height (H)
Total Height (TH)
173±2.0(6.81±0.08) 111±2.0(4.37±0.08) 329±2.0(12.95±0.08) 357±2.0(14.06±0.08)

TERMINAL TYPE
0.08)

111

2 (4.37

Terminal I3

Terminal B6

0.08)

25.5(1.00)

7.7(0.30)

6.0(0.24)

8.5(0.33)

10.5(0.39)

M8x1.25

357 2 (14.06 0.08)

2 (6.81

329 2 (12.95 0.08)

173

(M8 BOLT & NUT)

(M8 BOLT)

Terminal Hardware Initial Torque: 10.0 Nm ± 5%

o

o

MSU-200 (MSU-200FR) discharge characteristics (25C /77F )

Battery Charging Characteristics

Note: C=10HR Nominal Capacity (Ah)

(The graph of typical floating charging characteristics)

2.10

0.14

2.4

0.12

2.3

140

1.90
1.85
1.80
0.1C10A

1.75

0.165C10A

1.70

0.25C10A

0.10

0.08

0.06

0.04

1.65

120

Charge voltage

2.2

100

Charge volume
1 Discharge
100 %(0.1C 10A x 10h)
50 %(0.1C 10A x 5h)
2 Constant voltage charging
Charge voltage:2.25V/Cell
Charge current:0.1C 10A
3 Temperature:25°C(77°F)

2.1

2.0

1.9

80

60

Charge volume(%)

Charge current(C 10 A)

Terminal voltage(V)

2.00
1.95

Charge voltage(V)

2.05

40

0.55C10A

1.60

1C10A

0.02

1.55

20

Charge current

1.50
1

2

3

5

10

20

30

60

2

3

Min

5

10

20

0

0

0

4

8

12

16

20

24

28

32

36

0

Hr

Charging time (hr)

Discharge time

Effect Of Temperature On Long Term Float Life
Charging Procedure

20
15

For standby
power Source

Charging
method

Constant
voltage
(with current
restriction)

Charging
Voltage
at 25OC
(V/cell)

2.23~2.25

Temperature
compensation
coefficient of
charging voltage
(mV/ OC/cell)

-3

100%
discharge

24

Life expectancy(year)

Application

Charging time
0.1C 10 A, 25 O C
(h)

50%
discharge

20

10
8
6
5
4
3

Floating voltage:2.25V/Cell
2
1.4
20
68

30
86

40
104

50 oC
122 oF

Battery temperature

Constant power discharge characteristics at 25 oC/77 oF
Discharge
Time

Unit: W

30 Min

1 Hr

2 Hr

3 Hr

4 Hr

5 Hr

6 Hr

8 Hr

10 Hr

12 Hr

20 Hr

1.85V

262.3

180.0

115.8

90.2

70.1

60.4

53.8

44.5

37.2

32.24

20.09

1.80V

291.0

198.0

125.0

95.5

77.2

65.8

57.3

47.6

39.4

33.80

21.10

1.75V

318.8

210.0

132.5

100.6

80.9

68.8

59.8

49.1

41.1

34.95

21.70

1.70V

350.0

224.0

137.0

104.0

82.5

70.5

61.3

50.1

42.5

35.77

22.05

1.65V

376.0

231.0

139.0

106.2

84.2

71.5

62.5

51.0

43.1

36.28

22.24

1.60V

383.5

233.0

141.0

107.2

85.2

72.5

62.8

51.6

43.5

36.44

22.30

F.V.
(V/cell)

o

o

Constant current discharge characteristics at 25 C/77 F
Discharge
Time

Unit: A

30 Min

1 Hr

2 Hr

3 Hr

4 Hr

5 Hr

6 Hr

8 Hr

10 Hr

12 Hr

20 Hr

1.85V

140.0

96.0

61.0

47.2

37.0

31.3

27.0

22.0

18.7

16.21

10.10

1.80V

156.0

106.0

66.0

50.0

40.8

34.0

29.0

24.2

20.0

17.17

10.70

1.75V

172.3

113.0

70.3

52.9

42.8

36.0

31.0

25.3

21.1

17.94

11.13

1.70V

191.0

121.2

73.3

55.2

43.9

37.2

32.0

26.2

21.9

18.43

11.45

1.65V

204.5

126.1

75.3

57.0

45.0

38.2

33.2

27.0

22.3

18.67

11.60

1.60V

215.0

129.3

77.5

58.2

45.8

38.8

33.5

27.5

22.5

18.84

11.63

F.V.
(V/cell)

All data shall be changed without prior notice, BB reserves the right to explain and update the information contained hereinto.

A/4

USA:
B&B BATTERY(USA) INC.
6415 RANDOLPH ST.COMMERCE,CA,90040 U.S.A.
TEL:1-323-278-1900.1-800-278-8599
FAX:1-323-278-1268
E-Mail:[email protected]
CHINA FACTORY:
B.B. BATTERY CO., LTD.
CHENG DONG TRIAL AREA,HUANG GANG,
RAOPING, GUANG DONG,CHINA,515700
TEL:86-768-7601001-2
FAX:86-768-7601469
E-Mail:[email protected]

Web Site: http://www.bb-battery.com

REV. Jan. 2011

EUROPE:
B&B BATTERY(EUROPE) B.V.
SUITE 8, HAAKSBERGWEG 33, 1101
BP AMSTERDAM,THE NETHERLANDS
TEL: 31-30-3200190
MOBILE: 886-933896989
E-Mail: [email protected]

JAPAN:
B&B BATTERY(JAPAN) CO., LTD.
1375-11 NARAHARA-MACHI,HACHIOJI,
TOKYO 193-0803,JAPAN.
TEL:81-426-25-6375
FAX:81-426-25-6375
E-Mail:[email protected]

HONG KONG:
B&B BATTERY(Hong Kong) Co.
TEL:852-2311-4918
FAX:852-2739-1182
E-Mail:[email protected]

TAIWAN:
B.B. BATTERY(TAIWAN) CO., LTD.
TEL:886-6-502-5150
FAX:886-6-589-8087
E-Mail:[email protected]

Powered by

B.B. Battery Co., Ltd.

Sponsor Documents

Recommended

No recommend documents

Or use your account on DocShare.tips

Hide

Forgot your password?

Or register your new account on DocShare.tips

Hide

Lost your password? Please enter your email address. You will receive a link to create a new password.

Back to log-in

Close