1800 Series Inverted Bucket Steam Trap All Stainless Steel for Horizontal Installation Steam Trapping and Steam Tracing Equipment

For Pressures to 650 psig (45 bar)...Capacities to 1,802 lb/hr (817 kg/hr)

C C

B

B

D

D

A

A Model 1811 Trap

Model 1822 Trap

Description

A quick and easy “in-line” replacement for other types of side inlet/side outlet traps, the Armstrong 1800 Series brings together all the benefits of energyefficient inverted bucket operation. Side inlet/outlet all-welded construction means an inverted bucket trap that will operate efficiently on applications such as tracer lines, drips, heating, processing and similar applications. With the 1800 Series you get freeze-resistant, all-stainless steel construction, with a three-year guarantee, plus all the benefits of inverted bucket operation: Long, trouble-free service life • Excellent purging action • Continuous air venting • Ease and flexibility of in-line installation

Screwed NPT and BSPT Socketweld Flanged (consult factory)

Materials

Body: ASTM A240 Grade 304L Internals: All stainless steel—304 Valve and seat: Hardened chrome steel—17-4PH or Titanium

Options

Maximum Operating Conditions Maximum allowable pressure (vessel design): Model 1810, 1811: 400 psig @ Model 1822: 650 psig @ 627 psig @ 604 psig @ Maximum operating pressure: Model 1810: Model 1811: Model 1822:

Connections

800°F 600°F 700°F 800°F

(28 bar @ 427°C) (45 bar @ 315°C) (43 bar @ 371°C) (41.6 bar @ 427°C)

200 psig (14 bar) 400 psig (28 bar) 650 psig (45 bar)

• Insu-Pak™ insulation for Models 1810/1811 • Stainless steel pop drain for Models 1811/1822 • Probe connection for Models 1811/1822 • Restricted orifice • Wiggle wire

Specification

Inverted bucket steam trap, type ... in all stainless steel, freeze resistant, without gaskets, with continuous air venting at steam temperature, freefloating stainless steel mechanism, and orifice at the top of the trap.

How to Order

Specify: • Model number • Size and type of pipe connection • Maximum working pressure that will be encountered or orifice size • Any options required For a fully detailed certified drawing, refer to CD #1005.

1800 Series Traps Model No. Pipe Connections

1811 mm

in

mm

1822 in

mm

in

mm

in

mm 25

3/8, 1/2

10, 15

1/2

15

3/4

20

1/2, 3/4

15, 20

1

“A” (Diameter)

2-11/16

68

2-11/16

68

2-11/16

68

3-7/8

99

3-7/8

99

“B” (Height)

5-5/16

135

6-5/16

160

6-9/16

167

8-1/2

218

8-1/2

218

“C” (Face to Face)

4-5/16

110

4-5/16

110

4-5/16

110

5

127

5

127

“D” (Bottom to CL Inlet)

4-7/16

113

5-7/16

138

5-9/16

141

7-3/8

187

7-1/8

181

Weight lb (kg)

102

1810 in

1-3/4 (0.8)

2 (0.9)

2-3/8 (1.1)

7 (3)

Designs, materials, weights and performance ratings are approximate and subject to change without notice. Visit armstronginternational.com for up-to-date information.

North America • Latin America • India • Europe / Middle East / Africa • China • Pacific Rim armstronginternational.com

1800 Series Inverted Bucket Steam Trap All Stainless Steel for Horizontal Installation

For Pressures to 650 psig (45 bar)...Capacities to 1,802 lb/hr (817 kg/hr)

Pressure, bar

5

3

7

1

2

5

3

7

10

Pressure, bar

2

700

0.1

5

3

7

1

2

15*

30*

5

3

7

10

2

3

300

1,000

200

400

100

#38

200

200

70

150

50

100

40

#38 R60*

70

Capacity kg/hr

250

Capacity lb/hr

150

300

400

250

5/32

200

400 1/8 300

150

7/64

250

100

#38

200

5/64

70

150

50

1

25 50

250

3/16

500

100

30

500 200

01/4

700

300

70* 125

Capacity kg/hr

250

200

500

Capacity lb/hr

2

Steam Trapping and Steam Tracing Equipment

Model 1811 Capacity

Model 1810 Capacity

2

3

5

7

10

2

3

5

7

100

2

3

5

7

Pressure, psi

20

40

*Orifices available only with 3/4'' connections.

15

30 25

Options

10

*NOTE: Because the orifice is located at the top, inverted bucket steam traps handle dirt and scale better than other types of traps. However, in applications where extremely dirty conditions exist, care should be exercised in the use of all types of restricted-orifice, reduced-capacity traps.

Pop Drain for Freeze Protection In general, a properly selected and installed Armstrong trap will not freeze as long as steam is coming to the trap. If the steam supply is shut off, a pop drain should be used to automatically drain the trap. Stainless steel pop drain available for Models 1811 and 1822.

Model 1822 Capacity

Maximum Operating Conditions Pressure: 600 psig (41 bar) Temperature: 350°F (177°C)

5

7

10

2

3

5

7

Pressure, psi

1/4 3/16 5/32

1/8 7/64 #38

100

2

3

Valve Retainer SS Polished Ball O-Ring

Body Spring

Insu-Pak™ Now you can insulate the in-line traps in your plant without complicating regular trap maintenance. Insu-Pak, a simple reusable insulation package, cuts the time and cost of in-field installation because it goes on in a snap. And it comes off just as easily. Insu-Pak can prevent trap freeze-up when used with a properly designed condensate manifold. Designed for use with Model 1810 and Model 1811 traps. Probe connections are available for trap monitoring on Models 1811 and 1822.

Designs, materials, weights and performance ratings are approximate and subject to change without notice. Visit armstronginternational.com for up-to-date information.

North America • Latin America • India • Europe / Middle East / Africa • China • Pacific Rim armstronginternational.com

103

Sponsor Documents

Or use your account on DocShare.tips

Hide

Forgot your password?

Or register your new account on DocShare.tips

Hide

Lost your password? Please enter your email address. You will receive a link to create a new password.

Back to log-in

Close