PERHITUNGAN TOILET / LAVATORY PERHITUNGAN TOILET Total story Area per story, 24m x 48m Occupancy area per person Total person = (1152/8) x 5 Assumption Male user Assumption Female user

= 5 story = 1152 m2 (effective area) = 8m2/person = 720 persons = 60% = 40%

Assumption 1 toilet cater for 15 persons Total nos of toilet Male toilet Femae toilet = 750/15 = 48 toilets

= 48 x 60% = 28.8 toilets = 48 x 40% = 19.2 toilets

Requirements for each story: Male toilet = 28.5 / 5 Female toilet = 19.2 / 5

= 5.7 ≈ 6 toilets = 3.8 ≈ 4 toilets

PERHITUNGAN LAVATORY Total remaining same with toilet URINOIR Total remaining same with toilet