2013 Country by Country Statistics Overview a3
Comments
Content
STATISTICS OVERVIEW
Unit
Austria
Bulgaria
China
COUNTRY BY COUNTRY / 2013 Survey
Croatia
CzechRep.
Denmark
Estonia
Finland
France
Germany
72%
68%
69.77%
38.28%
76.76%
47.33%
2%
19.33%
23.02%
6.29%
28%
30%
10.89%
38.71%
Hungary
Iceland
Italy
90.25%
21%
10.45%
0.08%
16.95%
42.22%
9.67%
Japan
Kosovo
Korea
Latvia
Lithuania
68.5%
43%
78.9%
7.1%
0.1%
24.4%
Netherlands
Norway
Poland
Romania
55.06%
51%
69.95%
42%
17.06%
32%
15%
27.88%
Russia
Slovakia
Slovenia
Sweden
Switzerland
91.39%
54%
79%
70%
83.3%
0.7%
0.31%
2%
2%
23%
4.4%
17%
29.4%
8.30%
45%
19%
7%
12.2%
83,630
8,066
182,727
15,860
United
Kingdom
UAE
USA
Energy supply composition
for District Heat generated:
- Recycled heat
%
64%
67%
- Direct Renewables
%
23%
0.2%
- Others
%
13%
33%
Total District Heat sales 2011
TJ
73,176
20,664
2,810,220
9,980
88,240
101,940
22,885
112,290
78,502
279,938
(fed to grid)
31,647
26,472
26,360
21,958
187,024
24,984
26,243
26,800
13,859
235,000
49,095
Total District Heat sales 2007
(2009 if not available)
TJ
55,995
20,981
2,250,150
9,119
106,194
94,271
26,042
108,364
80,028
284,386
(fed to grid)
44,835
24,516
20,509
25,071
198,787
24,290
28,677
21,264
10,800
270,000
56,110
89,105
7,719
171,724
15,450
Annual District Heat sales turnover 2011
million
euro
1,022
221
1,685
2,834
352.9
1,661.9
1,435
294
83.12
1,264
2,282
383.50
488.12
221.7
2,522
713.84
1,684
121.39
3,968
356.85
Annual District Heat sales turnover 2007
(2009 if not available)
million
euro
812.5
183
85.47
1,582
2,180
232.6
1,127.0
1,247
56.39
950
1,912
236.10
318.31
194.4
2,538
758.61
1,725
83.44
2,550
Percentage of citizens served by
District Heating
%
21%
17%
10%
38%
61.07%
54%
50%
7.4%
12%
15%
64%
67%
1%
41%
19%
36%
15%
48%
4%
Trench length of District Heating
pipeline system 2011
km
4,376
1,555
147,338
7,592
30,288
1,450
13,060
3,644
20,151
3,468
734
22,800
1,100
Trench length of District Heating
pipeline system 2007 (2009 if not available)
km
3,816
1,495
102,986
7,740
27,851
1,420
11,000
3,131
3,471
678
19,500
940
Average District Heating price
Eur/ GJ
13.96
10.70
19.1
27.8
15.42
14.8
18.28
20.14
15.05
20.63
22.5
€ 13.85/
Steam;
8.64/Water
885
14
ca. 200
ca. 150
548
(systems)
5,604
22,940
16,293
Number of District Heating utilities
12
Total installed District Heating capacity
MWth
9,500
6,300
Total investment in District Heating 2011
million
euro
255.60
66
201
500
2,879
3,880
14,170
11,115
5,300
33,000
Estimated employment figures in
District Heating sector
District heated floor space
million m2
57
37.7
New connections to District Heating
households
6,300
172
Heat sales volume for new connections
to District Heating
TJ
CO2 emissions per TJ of District Heat generated Ton
CO2/TJ
22
75
338,742 +
85,273
(t/h) steam
4,737
145
2,037
(2009)
2,000
2,475
1,334
19,621
6,055
18,438
2,152
6,738
2,171
710
1,849
1,000
2,463
900
18,834
7,611
20.28
9.3
3.14
57.53
12.2
15.35
18.6
16
10.73
14.54
142
18
63
81
82
71
31
100
480
89
17,183
(2007)
344
65
440
systems
42
systems
138
7,638
2,241
2,556
only in CHP
4,248
38,321
3,210
8,719
2,893
58,300
13,619
541,028
(2007)
15,800
2,501
17,500
2,050
89,600
86
213
630
168
2,500
4,500
1,600
37,134
19,360
7,871
(2009)
26.3
34.8
495
55.6
150-200
266
438.5
18,000
26
55 kg/TJ
330,487
121,791
124,026
147,298
176,497
29,405
409,470
Total share of CHP in national electricity
production
16%
7%
28.9%
14%
63.2%
12.7%
36%
23,490
11,898
7,536
656
30.9
%
5,081
335 (2009)
213
4,682,000 ca. 300,000
3.3%
13.2%
2,286
96
49.5
181.8
600
2,582
36068
+ 1321
business
170.000
166,000;
11.8 M m2
1,300
15,173
6,160
50.21
58.02
(2009)
27,565
732,200
23.6%
32.6%
230
106
7%
161,280
53
(2009)
45
25,010
61,743
43%
69%
182,783
126
126
522 MJ/m2
3
Average energy use of buildings per m
District Cooling capacity 2011
MWth
35
156
668
161
District Cooling capacity 2007
(2009 if not available)
MWth
15
74
620
176
District Cooling sales 2011
MWh
64,832
125,880
876,000
171,667
(work)
District Cooling sales 2007
(2009 if not available)
MWh
6,751
55,680
889,000
187,556
(work)
Trench length of District Cooling
pipeline system 2011
km
7.4
77
145
Trench length of District Cooling pipeline
system 2007 (2009 if not available)
km
6
44
128
5,600
14.2
0.189 kg
CO2 / KWh
kWh/m²
2
159
2,951
1,860
TJ
TJ
6,970
11,335
Total heat demand 2011
CHP heat autoproduction
2,138
ca. 1,700
2,370
5,966
5%
1,264
2,150
354,871
(Steam +
Hot Water)
92%
49,931
(connected
load)
5%
6,891,293
(2007)
904.35 kJ/ 180-230
m2 (2009)
3,320
5,000
8.3
33,200
424
3.8
393.3
324
81.7
80.111 kg
CO2 per TJ
234,000
370,000
243,367
240,000
1%
17.1%
10.9%
19.2%
95
89
201
112
0.883
GJ/m²
6.9%
275,040
374,800
11%
3.2%
7.4%
9%
2,845 GWh
116.6
3,960
194
126.2
1
3,872
61
75.3
1
650
3,460,704
181,495
122,711
46
0.0255
900,000
4,274,666
24,073
80,810
46
0.0255
718,000
54
33
53
20
0.6
334
56
14.5
45
20
0.6
271
602
3%
24,932,703
ft2
101,6
Mg/TJ
1.62
210
173,100
(2007)
1%
20.44
Btu/m2
89
9,851
16,234
7,488
24,714,555
596
Sponsor Documents