NOTES:

12
4

12
10
3'-3"

3'-3"

3'-0"

3'-0"

2'-0"

2'-0"

AMENDMENTS

ALASKAN
LOG ENDS
2'-0" 1'-6"

1'-2"

4'-0"

1'-2"

PROJECT TITLE:

THE
ANCHORAGE
MAIN: 914 sq. ft.
LOFT: 525 sq. ft.

FRONT ELEVATION

PREPARED FOR:

RIGHT ELEVATION

12
4

12
4

PREPARED BY:
12
2'-0"

2'-0"

3'-3"

10

3'-3"

12
10

4'-0"

4'-0"

5'-6"

1'-6"

2'-0"

CANADA DIVISION
841-A S. MACKENZIE AVE.
WILLIAMS LAKE, BC
V2G 3X8 CANADA
PH (250) 392-5577
FAX (250)- 392-5581

3'-0"

3'-0"

U.S. DIVISION
P.O. BOX 301
PAYSON, ARIZONA
85547 - 0301
UNITED STATES
PH (928) 472-8073
FAX (928) 474-8991

DRAWING TITLE:

LEFT ELEVATION

REAR ELEVATION

ELEVATIONS
SCALE:

LOG STRUCTURE SETTLING INFORMATION:

1/4" = 1'-0"

TIGHTENING OF THRU-BOLTS:
THIS IS COMPLETED BY HOLDING THE BOTTOM OF THE THRU-BOLT ROD
STATIONARY, WHILE TURNING THE NUT CLOCKWISE UNTIL THE TENSION
SPRING ON THE BOTTOM OF THE TRHU-BOLT IS COMPRESSED AND
TIGHTENED. THIS NEEDS TO BE DONE TO ALL THRU-BOLTS IN THE HOME
WHEN THE HOUSE IS FIRST DELIVERED AND ABOUT EVERY THREE
MONTHS FOR THE FIRST THREE YEARS.
ADJUSTMENT OF ALL VERTICAL POSTS/STRUCTURAL POST:
INTERIOR & EXTERIOR
AS A RULE, WHEN THE THRU-BOLTS HAVE TO BE TIGHTENED ANY
EXTERIOR AND INTERIOR VERTICAL STRUCTURAL POSTS WITH SCREW
JACKS (STEEL SETTLERS) SHOULD ALSO BE ADJUSTED. THESE POSTS
WILL BE ADJUSTED BY THE SCREW JACKS ON EITHER THE TOP OR
BOTTOM. THE ADJUSTMENT SHOULD BE APPROXIMATELY THE SAME
AMOUNT AS THE THRU-BOLTS BECAUSE YOUR HOME WILL COME DOWN AN
AVERAGE AMOUNT ALL THE WAY AROUND THE EXTERIOR WALLS. AN
EXCEPTION TO THIS IS AT INTERIOR LOG WALL LOCATIONS; THE SETTLING
MAY BE INCREASED SOMEWHAT BECAUSE OF HEAT ON BOTH SIDES OF
THE WALL..

ELEVATIONS

DATE:
MARCH 31 2005
PIONEER LOG HOMES OF BRITISH COLUMBIA LTD. ASSUMES
RESPONSIBILITY FOR ARCHITECTURAL DESIGN & CONSTRUCTION OF
THE LOG WORK ONLY AS SHOWN IN THIS PLAN, PROVIDED THE LOG
WORK IS CONSTRUCTED BY PIONEER LOG HOMES OF BRITISH
COLUMBIA LTD. ALL OTHER ELEMENTS ARE TO BE APPROVED BY
LOCAL BUILDING AUTHORITIES & BUILT TO LOCAL BUILDING CODES. ANY
ENGINEERING REQUIRED & RELATED COSTS ARE THE
RESPONSIBILITY OF THE OWNER.

DRAWN BY:
D. FITZEL
CHECKED BY:
PAGE:

A-1

NOTES:
24'-0"

5'-6"

12'-0"

12'-0"

TYPICAL ROOF ASSEMBLY:
METAL ROOFING, COLOR AS PER CLIENTS'SPECS
2x4 WOOD STRAPPING 22"oc
2x12 WOOD RAFTERS 24"oc
BATT INSULATION
6 MIL POLY AV BARRIER
T&G WOOD PANEL
9'-8"

12

12

26'-9"

PROJECT TITLE:
GUARD RAIL TO LOCAL CODE

LOG KICKER BEAM TO
SUPPORT RAFTER TAILS
BELOW DORMER

36'-0"

8'-0"

10
LOFT FLOOR BUILD-UP:
2x6 T&G DECKING
OVER LOG FLOOR JOISTS

LOG BEAM TO SUPPORT
RAFTER TAILS BELOW DORMER

LOG RIDGE BEAM

10'-6" HIGH LOG WALLS:
HAND CRAFTED, SCRIBE FITTED LOG
WALL WITH BATT INSULATION IN
LATERAL GROOVES AND NOTCHES.
STAIRS MAIN TO LOFT:
HALF LOG STRINGERS W/
APPROX. 3"x 11" TIMBER TREADS.

1
A-2

MAIN FLOOR ASSEMBLY:
FINISH FLOOR TO CLIENTS' SPECS
5/8" T&G PLYWOOD SUBFLOOR
2x10 WOOD FLOOR JOISTS 16"oc

12'-0"

9'-3"

1
A-2

LOG POST BETWEEN
MAIN FLOOR & BEAM
SETTLER AT BASE W/
MIN 5" SETTLING SPACE.
SOLID BLOCKING BELOW
BETWEEN JOISTS

CRAWL
SPACE

GLULAM BEAM OR
3 PLY 2x10 B/U
WOOD BEAM

LOG POST BETWEEN
DECK FLOOR & BEAM
SETTLER AT BASE W/
MIN 5" SETTLING SPACE.
SOLID BLOCKING BELOW
BETWEEN JOISTS

9'-2"

CRAWL
SPACE

18'-4"

20" WIDE x 10" DEEP
POURED CONCRETE
FOOTING.
REINFORCE AS PER
ENGINEER'S DESIGN
REQUIREMENTS.

SOLID
BLOCKING

11'-0"

1'-7"

3'-0"

GENERAL NOTES ON
FOUNDATIONS AND FOOTINGS

3'-3"

10'-5"

8'-9"
10'-5"

12'-0"

CROSS SECTION

1'-7"

12'-0"

FOUNDATION PLAN
LOG WALL - SCREW FIRST LOG TO BLOCK
USE (4) 3/8" x 16" GRK SCREWS
MIN. 6" IN BLOCK

SOLID GLU-LAM WOOD BLOCK
BETWEEN JOISTS. TYPICALLY
ONE BLOCK PER EVERY EIGHT
FEET.

4" MIN.

1 1/4"

3" 4 1/4" 4 1/4" 3"

1 1/2"

SOLID GLU-LAM BLOCKING
BETWEEN JOISTS COUNTERSINK
FOR NUT AND COUPLING AS
REQUIRED.

1 1/4"

2 - 5/8" dia. J-BOLTS
PER BLOCK MIN 3" IN
BLOCK MIN 7" IN
CONCRETE

ANCHOR BOLT LOCATIONS

USE (4) 3/8" x 16" GRK FASTNERS
TO SCREW FIRST ROUND OF LOGS
TO WOOD BLOCK.
LOG WALL
3/4" GAP FOR FLOOR FINISH

14 -1/2"

3/4" dia. NUT AND COUPLER
IF REQUIRED.
USE (4) 3/8" x 16" GRK FASTNERS
TO SCREW FIRST ROUND OF LOGS
TO WOOD BLOCK.
WOOD FLOOR JOIST
COUPLING AS REQUIRED
CONCRETE WALL

FINISH FLOOR TO CLIENTS SPECS.
ON PLYWOOD SUBFLOOR

1x4 WOOD SPACER & 2x4 IF
GYP-CRETE TOPPING
GALV. DRIP EDGE. BROWN
OR GREEN

5/8" dia. ANCHOR BOLT

WOOD FLOOR JOIST

SOLID GLU-LAM WOOD BLOCK
BETWEEN JOISTS. APPROX. 5 1/8" WIDE
AND SAME DEPTH AS JOISTS.
COUNTERSINK FOR
NUT AND COUPLING. PLACE AS SHOWN
ON FOUNDATION PLAN.

WOOD FLOOR JOIST
CONCRETE WALL TOP PLATE

FIRST ROUND ANCHORING DETAIL
PROVIDE ONE EVERY 8'-0"

FOUNDATION PLAN & SECTIONS

"GRK" SPACING PATTERN
FOR ANCHORING FIRST ROUND OF LOG WALL

CANADA DIVISION
841-A S. MACKENZIE AVE.
WILLIAMS LAKE, BC
V2G 3X8 CANADA
PH (250) 392-5577
FAX (250)- 392-5581

GENERAL NOTES

1. CONCRETE STRENGTH TO BE 2500 PSI @ 28 DAYS FOR FOOTINGS TO BE
3000 psi @ 28 DAYS FOR CONCRETE SLAB.
2. FOOTING DEPTH TO BELOW FROST LEVEL. CONSULT LOCAL BUILDING
DEPARTMENT FOR LOCAL FROST PENETRATION DEPTHS.
3. ALL FOOTING SIZES AND REINFORCING SPECIFICATIONS ON THIS PLAN ARE
BASED ON A MINIMUM GROUND BEARING CAPACITY OF 1500 psf OR GREATER.
4. SINCE SOILS < 11 psi CAN SWELL OR REBOUND, THE FOUNDATION AND FOOTINGS
DESIGN MUST COMPLY WITH LOCAL BUILDING CODE REGULATIONS AND GOOD
BUILDING PRACTICES.
5. ALL SONOTUBES SUPPORTING LOG POSTS TO HAVE 1 ½" dia. REDI-ROD
LOCATED AT THE CENTER. REDI-ROD TO BE 36" LONG AND TO PROJECT
APPROX. 12" ABOVE TOP OF SONOTUBE (U.N.O.)

11'-0"

12'-0"

PREPARED BY:

POURED CONCRETE PAD
FOOTING. REINFORCE AS
PER ENGINEER'S
REQUIREMENTS.

20"WIDE x 10" THICK POURED
CONCRETE FOOTING. REINFORCE
AS PER ENGINEER'S REQUIREMENTS.

3'-6"

D
WOO
B/U AM
BE

PREPARED FOR:

MIN 8" dia. CONCRETE FILLED
SONOTUBE
SITTING ON POURED CONCRETE
PAD FOOTING.
REINFORCE AS PER ENGINEER'S
REQUIREMENTS.

STRUCTURAL
POST

8" THICK CONCRETE FOUNDATION
WALL. REINFORCE AS PER
ENGINEER'S REQUIREMENTS.

4'-0"

2x8 JOISTS 24" oc
B/U
WO
BEA OD
M

MAIN: 914 sq. ft.
LOFT: 525 sq. ft.

DECKING AS PER CLIENTS'SPECS
2x8 JOISTS 24"oc ON
3 PLY 2x8 B/U WOOD BEAM

BEAM POCKET

MIN. 8" dia. CONCRETE
FILLED SONOTUBE
SITTING ON POURED
CONCRETE PAD FOOTING.
REINFORCE AS PER
ENGINEER'S
REQUIREMENTS.
TYP ALL DECK FOOTINGS

THE
ANCHORAGE

STRUCTURAL POST
GLULAM BEAM

11'-6"

8" THICK CONCRETE
FOUNDATION WALL.
REINFORCE AS PER
ENGINEER'S DESIGN
REQUIREMENTS.

2 X 8 JOISTS
24"oc

LOG DORMER BEAM SUPPORTED
BY LOG POSTS. FLATTEN BOTTOM OF
BEAM WHERE POST INTERSECTS. USE WOOD
DOWEL BETWEEN POST AND BEAM

4

7'-6"

POURED CONCRETE PAD
FOOTING. REINFORCE AS
REQUIRED.
(4 PLACES)

3 - 2 X 8 BEAM

7'-8"

LOG DORMER BEAM SUPPORTED
BY LOG POSTS. FLATTEN BOTTOM OF
BEAM WHERE POST INTERSECTS. USE
WOOD DOWEL BETWEEN
POST AND BEAM

2x10 FLOOR JOISTS 16" oc

AMENDMENTS

LOG RIDGE BEAM
SEE DETAIL
SHEET

7'-6"

8'-10"

BEAM POCKET

FIRST ROUND ANCHORING DETAIL OVER CONC. FDTN. WAL
NOTE: USE "GRK" FASTENERS AS INDICATED

1. ALL ENGINEERING INSPECTIONS AND COSTS REQUIRED AT ANY TIME
FOR THE BUILDING WILL BE THE SOLE RESPONSIBILITY OF THE OWNER
2. CONTRACTOR TO VERIFY ALL DIMENSIONS ON SITE.
3. WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED
DIMENSIONS.
4. ALL WORK SHALL CONFORM TO THE CURRENT EDITION OF THE LOCAL
BUILDING CODE.
5. INFORMATION CONTAINED ON THESE DRAWINGS SHALL BE AT THE
DISCRETION OF THE CONTRACTOR PROVIDED IT MEETS WITH THE ABOVE
REQUIREMENTS AND REPRESENTS SOUND BUILDING PRACTICE.
6. ALL DIMENSIONAL LUMBER TO BE SPF No. 2 OR BETTER . UNLESS
NOTED OTHERWISE. (U.N.O.)
7. PROVIDE SMOKE DETECTORS AS REQUIRED, PREFERABLY ONE PER
LIVING SPACE. AT LEAST ONE SMOKE ALARM IS TO BE LOCATED NOT
MORE THAN 24" FROM THE HIGHEST POINT INSIDE THE STRUCTURE. ALL
DETECTORS TO BE PERMANENTLY WIRED 110 V. INTERCONNECTED EACH
FLOOR.W/ BATTERY BACK-UP.
8. PERIMETER DRAIN, IF REQUIRED, TO BE IN ACCORDANCE WITH LOCAL
BUILDING CODE.
9. FLOOR JOISTS TO REST ON 2x6 TREATED SILL PLATE OR DOUBLE TOP
PLATE.
10. 2x6 TREATED SILL PLATE TO BE ANCHORED TO FOUNDATION WALL
USING MIN. 5/8" dia. STEEL ANCHOR BOLTS W/ 2" x 2" x 3/16" WASHERS
SPACED NOT MORE THAN 4'-0" o.c..
11. SITE PLAN AND LEGAL SHALL BE SUPPLIED AND COMPLETED BY
OWNER.
12. OWNER AND CONTRACTOR SHALL CHECK THE SPECIFICATIONS AGAINST
THE BLUEPRINTS.
13. ACTUAL DOORS AND WINDOWS USED ON THE JOB MAY VARY IN
MAKE-UP AND APPEARANCE FROM BLUEPRINT UNLESS SPECIFIED.
14. OWNER TO ENSURE THAT THE FOLLOWING IS COMPLETE PRIOR TO THE
ARRIVAL OF THE LOG PACKAGE. FIRST FLOOR FRAMING TO BE COMPLETE
AND SUBFLOOR INSTALLED. 1x4 WOOD SPACERS TO BE NAILED TO
SUBFLOOR AT LOG WALL LOCATIONS FOR LOG WALLS TO SIT ON. A 2x4
WOOD SPACER WILL BE USED IN ADDITION TO THE 1x4 IF A POURED
CONCRETE TOPPING FOR HEATING IS TO BE USED ON THE FIRST FLOOR.
ALL EXTERIOR WOOD SPACERS TO HAVE SILL SEAL ABOVE AND BELOW
WITH A GALVANIZED DRIP EDGE ABOVE THE WOOD SPACERS AND SILL
SEAL. THIS DRIP EDGE TO BE BROWN, GREEN, COLORED OR COPPER.
15. OWNER TO PROVIDE 1x4 WOOD SPACERS WHICH ARE TO BE USED AT
THE TOPS OF LOG WALLS AND LOG ROOF MEMBERS (PURLINS, RIDGE
BEAMS) WHICH SUPPORT THE ROOF.

U.S. DIVISION
P.O. BOX 301
PAYSON, ARIZONA
85547 - 0301
UNITED STATES
PH (928) 472-8073
FAX (928) 474-8991

DRAWING TITLE:

FOUNDATION
PLAN
& SECTIONS
SCALE:
1/4" = 1'-0"
DATE:
MARCH 31 2005
DRAWN BY:
D. FITZEL
CHECKED BY:
PAGE:

A-2

NOTES:

AMENDMENTS
24'-0"

12'-0"
4'-2"

3'-0"
4'-0"

VAULTED

4'-6"

13'-8"

PREPARED FOR:

2'-8"
6'-8"

CLOSET

10'-3"

5'-0"
3'-6"

19'-6"

22'-4"

5'-2"

PREPARED BY:

2x6 @ 16" oc FRAME WALL OVER
2 PLY 2x12 SPF#2 & BTR RAFTERS

1
A-2

1
A-2

OPEN
TO
BELOW

9'-3"

4'-0"
5'-0"

16'-6"

6'-0"
5'-0"
3'-6"

6'-0"

5'-6"

8'-0"

2'-8" STEP
6'-8" UP

10'-3"

5'-8"

BATH

MAIN: 914 sq. ft.
LOFT: 525 sq. ft.

5'-1"

16'-6"

110 V. - TO BE
INTERCONNECTED
EACH FLOOR

OPEN
LOFT

18'-4"
VAULTED

SD

THE
ANCHORAGE

5'-0"
3'-6"

GIARD RAIL TO
CODE

LOG BEAM

DINING

MASTER
BEDROOM

4'-0"

LOG DORMER BEAM

11'-0"

9'-8"
16'-6"

9'-8"

LOG KICKER BEAM

6'-0"
6'-8"

4'-0"
3'-0"

9'-3"

GREAT
ROOM

LOG POST w/
STEEL
SETTLER

WIC

7'-2"

19'-6"

LOG FLOOR JOIST

13'-4"
6'-2"

KITCHEN

LOG POST w/
STEEL
SETTLER

4'-0"
5'-0"

1
A-2

LOG BEAM
DW

16 R. @ 7"
15 T. @ 10"

LOG POST w/
STEEL
SETTLER

DN

3'-0"
6'-8"

36'-0"

LOG BEAM

COV'D
ENTRY

4'-0"

2'-8"
6'-8"

LOG &
TIMBER
STAIRS
TO CODE

110 V. - TO BE
INTERCONNECTED
EACH FLOOR

PROJECT TITLE:
LOG POST w/ SIDES
FLATTENED WHERE FRAME
WALLS TIE IN

5'-6"

5'-6"
36'-0"

BATH

SD

2'-8"
6'-8"

110 V. - TO BE
INTERCONNECTED
EACH FLOOR

LOG FLOOR JOIST

2'-0"
6'-8"

SD

2'-8"
6'-8"

LOG KICKER BEAM

11'-0"
16'-6"

UTILITY
ROOM

BEDROOM

12'-0"

4'-7"

16 R. @ 7"
15 T. @ 10"

2'-0"
6'-8"

3'-3"

2x12 SPF #2 & BTR
RAFTERS @ 24" oc

3'-3"

2'-6"

4'-0"
4'-0"

3'-10"

4'-0"
4'-0"

3'-10"

6'-3"

6'-0"

5'-6"

DN

4'-4"

24'-0"

5'-6"

LOG DORMER BEAM

6'-0"

11'-3"

6'-0"
6'-8"

2'-6"

LOG RIDGE BEAM

10'-3"

6'-0"

1
A-2

CANADA DIVISION
841-A S. MACKENZIE AVE.
WILLIAMS LAKE, BC
V2G 3X8 CANADA
PH (250) 392-5577
FAX (250)- 392-5581

2x12 SPF #2 & BTR
RAFTERS @ 24" oc

8'-0"
7'-0"

8'-0"
5'-0
"

4'-0"

4'-0"

U.S. DIVISION
4' R
AKE

P.O. BOX 301
PAYSON, ARIZONA
85547 - 0301
UNITED STATES
PH (928) 472-8073
FAX (928) 474-8991

AKE
4' R
4' R
AKE

AKE
4' R

DECK
LOFT FLOOR ASSEMBLY:

DRAWING TITLE:

FLOOR
PLANS

2x6 T&G WOOD DECKING
LOG FLOOR JOISTS
LOFT PLUMBING FLOOR ASSEMBLY:

EAGLE
CARVING

MAIN FLOOR PLAN

LOFT FLOOR PLAN

FINISH FLOOR TO CLIENTS SPECS
5/8" PLYWOOD SUBFLOOR
2x8@ 16" oc JOISTS ON EDGE
2x6 T&G WOOD DECKING
LOG FLOOR JOISTS

SCALE:
1/4" = 1'-0"
DATE:
MARCH 31 2005
DRAWN BY:
D. FITZEL
CHECKED BY:
PAGE:

FLOOR PLANS

A-3

NOTES:

PLYWOOD SHEATHING
ROOF RAFTERS TO SIT ON
1x4 WOOD SPACER. THIS
ENSURES A 3/4" GAP FOR
FINISH CEILING TO SLIDE INTO

SOLID WOOD BLOCKING. DEPTH
EQUAL TO JOIST DEPTH

THRU-BOLTS: USE 2 3/4" x 3/8"
TIMBER WASHER W/ 5/8" NUT @ TOP &
BOTTOM OF THREADED ROD

HEADER LOG

SETTLING SPACE
BETWEEN TRIM AND TOP
OF CUT

TOP ROUND OF LOG WALL

BATT INSULATION AND
SETTLING SPACE

HEADER LOG

SETTLING SPACE
BETWEEN TRIM AND TOP
OF CUT
BATT INSULATION AND
SETTLING SPACE

1 1/4" THICK SETTLING CROWN

1 1/4" THICK SETTLING CROWN

WINDOW HEAD JAMB

5/8" THREADED ROD

DOOR HEAD JAMB

INSULATED GLASS

AMENDMENTS

DOOR UNIT

WOOD FASCIAS
HAND PEELED LOG WALL

WOOD RAFTERS SPACED
AS PER PLAN

LOG WALL/ROOF INTERSECTION DETAIL

2 x 6 WOOD
MUD SILL

WINDOW HEADER DETAIL

DOOR HEADER DETAIL

PROJECT TITLE:

LOG WALL
SIMPSON
BEAM SEAT
ROOF CHOICE MATERIALS TO
CLIENTS SPECS.

WALL LOG - BEVEL OPTIONAL

WALL LOG - BEVEL OPTIONAL

WOOD BLOCKING BETWEEN
RAFTERS

SILL SEAL TOP AND
BOTTOM OF SPACER

WOOD BEAM
CONCRETE
FOUNDATION
WALL

1x4 WOOD SPACER PROVIDING
3/4" GAP FOR FLOOR FINISH

VAPOUR BARRIER TO RUN
BETWEEN SPACER AND
INSULATION
1X4 WOOD SPACER

MIN. 1/2" AIR
SPACE AT SIDES
AND END OF BEAM

WOOD FASCIA

GALV. DRIP EDGE
BROWN OR GREEN

5/8" ANCHOR BOLT

6" MIN.

FINISHED GRADE TO
SLOPE AWAY FROM
STRUCTURE

CONCRETE
STEM WALL

5/8" dia. STEEL ANCHOR
BOLTS W/ 2"x2"x3/16
WASHERS, @ 48" o.c.

#4 HORIZONTAL @ TOP OF WALL, @MID
POINT & (2) IN FOOTING COVERED BY 3"
MIN. CONCRETE.

BOTTOM OF FOOTING
TO BE 18" MIN. BELOW
UNDISTURBED SURFACE.

HANDRAIL TO BE 36" ABOVE NOSING
OF TREAD.
BALUSTERS TO BE SPACED SUCH
THAT A 4" Ø SPHERE CANNOT
PASS THRU

DOOR JAMB DETAIL

INSULATED GLASS

HANDRAIL TO
TERMINATE
AT POST

SLOT FOR SPIKE TO
SLIDE WITH LOG
SETTLING

1/2 LOG STRINGER

HAND PEELED LOG
RIDGE BEAM.
SPIKE OR LAG

1 1/2" x 8" SQUARE DOWEL
POSITIONED IN CIRCULAR HOLE..

1/2" T&G WOOD FINISH

FRAMED WALL/LOG WALL INTERSECTION

PREPARED BY:

3" x 11" TIMBER
TREAD

KEYWAY FOR FINISH

TOP VIEW

WINDOW SILL
WINDOW TRIM

SIDE VIEW

FRONT VIEW

TYPICAL CONCRETE STEM WALL & FOOTING
FOR CRAWL SPACES (PER C.B.C. TABLE 18-1-C)

ENGINEERED BEAM

WINDOW JAMB DETAIL

ROOF RAFTERS TO SIT ON
1x4 WOOD SPACER. THIS
ENSURES A 3/4" GAP FOR
FINISH CEILING TO SLIDE
INTO.

SOLID
BLOCKING
IF SEISMIC

PREPARED FOR:

INSULATION SURROUND

WOOD RAFTERS SPACED
AS PER PLAN

#4 VERTICAL EVERY 48" o.c.
BEND BOTTOM OF
REBAR & ALTERNATE
DIRECTION OF BEND.

CUT 2"x4" KEYWAY FOR 3" x 1-1/2" x O.188" HSS
TUBING HEIGHT TO MATCH LENGTH OF DOOR JAM.

INSULATION SURROUND

LOG WALL KEYED FOR
WALL FINISH

LENGTH OF REBAR STUB
EQUALS 30 BAR
DIAMETERS (MIN.)

DRAINPIPE &
DRAINROCK PER
LOCAL CODE.

9 - 11 NAILS PER
BYPASS

SPIKES

DOOR TRIM

2x4 KEYWAY

LOG WALL / ROOF INTERSECTION

MAIN: 914 sq. ft.
LOFT: 525 sq. ft.

2x8 WOOD BUCK

WINDOW TRIM

WOOD FLOOR JOIST

INTERIOR LOG WALL SHEAR BOLT DETAIL

DOOR UNIT

2x8 WOOD BUCK

HAND CRAFTED, SCRIBE
FITTED LOG WALL

P.T. 2 x 6 WOOD
MUD SILL

SCREW FASTENER
DOOR SIDE JAMB
FASTENED TO WOOD BUCK ONLY

INSULATED GLASS

CHANNEL PROVIDED
BY SPACER FOR CLG.
FINISH

FLOOR FINISH AS
PER CLIENTS SPECS.

BEAM POCKET DETAIL - FOUNDATION

SCREW FASTENER
WINDOW SIDE JAMB
FASTENED TO WOOD BUCK ONLY

THE
ANCHORAGE

CANADA DIVISION

HAND PEELED LOG POST

LOG RIDGE BEAM DETAIL (TYPICAL FOR TOP & BOTTOM
OF ALL POSTS EXCEPT @ SETTLER LOCATIONS)

WINDOW SILL DETAIL

STAIR / HANDRAIL DETAIL

841-A S. MACKENZIE AVE.
WILLIAMS LAKE, BC
V2G 3X8 CANADA
PH (250) 392-5577
FAX (250)- 392-5581

SIMPSON PC 66 COLUMN CAP

U.S. DIVISION

DOOR OR WINDOW
OPENING

P.O. BOX 301
PAYSON, ARIZONA
85547 - 0301
UNITED STATES
PH (928) 472-8073
FAX (928) 474-8991

LOG FLOOR JOIST
6x6 PT STRUCTURAL POST

FINISH CEILING TO CLIENTS
SPECS.

SIMPSON PB 66 COLUMN BASE
SLAB REINFORCEMENT
AS REQUIRED

KEYWAY

1 1/2" T&G DECKING

2x6 WOOD NAILER
MIN. 5" SETTLING SPACE

GYPSUM BOARD

SEE PLAN &
ENGINEERING SCHEDULE
2x4 WOOD TOP PLATE

ALTERNATE INTERIOR FOOTING
GYPSUM BOARD

LOG FLOOR JOIST WITH TOP
FLATTENED FOR FLOOR
ASSEMBLY ABOVE.

6"
1"

CUT KEYWAY FOR T&G DECKING.

STEEL SETTLER SITTING ON
DECK NAIL TO BLOCKING AT
CORNERS.

INTERIOR FRAME WALL SETTLING DETAIL

4"

LOFT FLOOR FRAMING DETAIL (EXCEPT BATHROOM)

6"

1"

PLAN VIEW
FLATTEN LOG FOR
FACE PLATE

3/4" FINISH FLOOR

INTERIOR SUBFLOOR

3/4" SUBFLOOR
2x8 JOISTS 16" o.c.
1 1/2" T&G DECKING

EXTERIOR DECKING

RIM JOIST
1 1/2" dia. REDI-ROD 36" LONG. 12" EXTENDED
ABOVE TOP OF CONCRETE.

PERSPECTIVE
VIEW

MIN. 8" dia. CONCRETE FILLED SONOTUBE
SITTING ON CONCRETE PAD FOOTING.

2x WOOD DECK JOISTS
METAL JOIST HANGER
CONCRETE FOUNDATION
WALL

PRESSURE TREATED LEDGER
BOLTED TO FRAMING

DECK JOIST/FOUNDATION WALL DETAIL

ELECTRICAL BOX

1 1/2" NF REDI-ROD 9"LONG

FLOOR JOIST

WASHER

DRAWN BY:

1 1/2" NF NUT

D. FITZEL

DRILL THROUGH LOG
TO INSIDE OF RIM JOIST

LOG FLOOR JOIST WITH TOP
FLATTENED FOR FLOOR
ASSEMBLY ABOVE.

SOLID BLOCKING
BETWEEN JOISTS @
BELOW SETTLER

CUT KEYWAY FOR T&G DECKING.
SUBFLOOR AND FINISH FLOOR

LOFT PLUMBING FLOOR

ALLOW MIN 5" SETTLER
SPACE AT SET UP

DATE:
MARCH 31 2005

3/8" x 6" MS PLATE
WOOD
SPACER

WOOD RIM JOIST

COVERED DECK LOG POST SETTLER DETAIL

SCALE:
1/4" = 1'-0"

2x WOOD DECK JOISTS

DETAILS

DETAILS

1"

LOG COLUMN

ALLOW MIN. 5" SETTLING
SPACE AT TIME OF SET UP.

FLOOR SUPPORT BEAM

4"

1"

ELECTRICAL SWITCH DETAIL
HAND PEELED LOG POST WITH
BASE SQUARED TO SETTLE
THROUGH DECK.

DRAWING TITLE:

RUN ELECTRICAL WIRES
IN KEYWAY BEHIND 2 x 4
& DRILL OVER TO BOX LOCATION

ELECTRICAL RECEPTICLE DETAIL

STEEL SETTLER UNDER LOG COLUMN

1/4" HOLES FOR NAILING,
4 PLACES EACH PLATE

THREADED ROD
WELDED TO PLATE

CHECKED BY:
SIDE VIEW

PAGE:

A-4