I. T$r's an# ($)!n!t!ons
absorbate
that substance absorbed by an absorbent.
absorbent
material which, due to an affinity, extracts one or more substances from a liquid or
gaseous medium with which it is in contact and which changes physically or chemically,
or both, during the process. Calcium chloride is an example of a solid absorbent, while
solutions of lithium chloride, lithium bromide, and the ethylene glycols are examples of
liquid absorbents.
absorber
1. device containing fluid, or other material, for absorbing refrigerant vapor or other
vapors.
2. chill factor part of the solar collector receiving the incident radiation energy and
transforming it into thermal energy. It may possess a surface through which energy is
transmitted to the transfer fluid; however, the transfer fluid itself can be the absorber.
absorber area in a solar collector!
1. total heat transfer area from which the absorbed solar irradiance heats the transfer
fluid.
2. area of the absorber medium if both transfer fluid and solid surfaces "ointly perform
the absorbing function; i.e., total area onto which incident solar radiation is absorbed.
#. total area onto which incident solar radiation is absorbed.
absorptance (⟨)
1. absorbed portion of the radiant energy stri$ing a surface.
2. ratio of the radiant flux absorbed by a body to that incident upon it. Compare
reflectance.
absorption
1. process whereby a porous material extracts one or more substances from an
atmosphere, a mixture of gases, or a mixture of liquids.
2. transformation of radiant energy to a different form of energy by interaction with
matter.
#. absorption of acoustical energy by acoustical materials and air.
absorptivity
absorbed portion of the radiant energy stri$ing unit area of a substance. Compare
absorptance.
acceleration due to gravity
rate of increase in velocity of a body falling freely in a vacuum; its value varies with
latitude and elevation. %he International &tandard, derived from the value at sea level
and '() latitude, is *.+,- -( metres per second per second m.s2!, or #2.1/' feet per
second per second ft.s2!
acceptance angle
angular 0one within which radiation is accepted by the receiver of a concentrator.
1adiation is said to be accepted if radiation incident within this angle reaches the
absorber after passing through the aperture.
accessible
as applied to equipment! equipment is accessible when close approach is not
prevented by loc$ed doors, elevation, or other effective means. Compare readily
accessible.
readily accessible
capable of being reached quic$ly for operation, renewal, or inspections, without
requiring those to whom ready access is requisite to climb over or remove obstacles
or to resort to portable ladders, chairs, etc. Compare accessible.
accessory
part or assembly that aids the effectiveness of equipment without changing its function.
accumulator
1. vessel for storing low2pressure2side liquid refrigerant; also $nown as a low2pressure
receiver, surge drum, surge header, or surge tan$.
2. pressure vessel whose volume is used in a refrigerant circuit to reduce pulsation.
#. pressure vessel connected to more than one circuit of a pneumatic system to obtain
the average pressure of the connected circuits.
'. apparatus to store cold by accumulation of ice on a coil.
accuracy
1. conformity of an indicated value to an accepted standard value, or true value.
3uantitatively, it should be expressed as an error or an uncertainty. %he property is
the "oint effect of method, observer, apparatus, and environment. 4ccuracy is
impaired by mista$es, by systematic bias such as abnormal ambient temperature, or
by random errors imprecision!.
2. degree of freedom from error, that is, the degree of conformity to truth or to a rule.
4ccuracy is contrasted with precision, e.g., four2place numbers are less precise than
six2place numbers; nevertheless a properly computed four2place number might be
more accurate than an improperly computed six2place number.
#. ability of an instrument to indicate the true value of a measured physical quantity.
Compare precision, reliability, repeatability.
acoustics
1. science of the production, transmission, and effects of sound.
2. characteristics of a room that determine the qualities of sound therein, relative to
hearing.
activated carbon
form of carbon made porous by special treatment by which it is capable of adsorbing
various odors, gases, and vapors.
actuator
device, either electrically, pneumatically, or hydraulically operated, that acts as a motor
to change the position of movable devices such as valves or dampers.
addenda
set of revisions to a standard in the form of a supplement.
adiabatic exponent
exponent $ in the equation pv$ 5 constant, representing an adiabatic change $ is the
ratio of the specific heat at constant pressure to the specific heat at constant volume!.
adiabatic process
thermodynamic process during which no heat is extracted from or added to the system.
ad"ustable2frequency drive 467!
electronic device that varies its output frequency to vary the rotating speed of a motor,
given a fixed input frequency. 8sed with fans or pumps to vary the flow in the system as
a function of a maintained pressure.
adsorbent
material that has the ability to cause molecules of gases, liquids, or solids to adhere to
its surfaces without changing the adsorbent physically or chemically. Certain
commercially available solid materials, such as silica gel, activated carbon, and
activated alumina, have this property.
adsorption
1. process in which fluid molecules are concentrated on a surface by chemical or
physical forces, or both.
2. surface adherence of a material in extracting one or more substances present in an
atmosphere or mixture of gases and liquids, unaccompanied by physical or chemical
change.
aerodynamic excitation
time varying loads acting on the blades of a fan due to nonconformities of the air flow.
9ote: &patial nonuniformities of airflow which are steady in time give rise to harmonic
excitation at frequencies which are integer multiples of the rotation rate of the fan. %ime
excitations of the airflow give rise to random excitation.
aerosol
small particles, solid or liquid, suspended in air, e.g., dust, fumes, fog, and smo$e. %he
diameter of the particles may vary from micrometres formerly micron! down to less
than ,.,1 micrometre. &ee fumes.
air
the atmosphere; the mixture of invisible, odorless, tasteless gases nitrogen, oxygen,
and others! that surrounds the earth.
ambient air
surrounding air usually outdoor air or the air in an enclosure under study!.
cleansed air
air that has been treated to remove pollutants, particulates, and odors.
combustion air
air required to provide for the complete combustion of fuel, and usually consisting of
primary air, secondary air, and excess air.
conditioned air treated air!
air treated to control its temperature, relative humidity, purity, pressure, and
movement.
cooling air
1. cooled air used to lower the temperature of a space or products stored in a space.
2. atmospheric air used to remove heat from a device, space, or system.
dry air
1. air without entrained water vapor.
2. air unmixed with or containing no water.
Note: Composition of dry air is defined in ISO 2533-1975 and shown in the ASHRA
p!"#i$ation Psychrometrics;Theory and Practice%
excess air
in combustion, percent of air greater than that required theoretically to completely
oxidi0e the fuel.
exhaust air extracted air!
air discharged from a space to the outdoors as differentiated from air transferred from
one space to an ad"acent one.
exit air
air that is e"ected from a system and replaced by fresh air.
first air
in a clean room, air that issues directly from the <=>4 filter before it passes over any
wor$ location.
ma$eup air
1. air brought into a building from the outside to replace that exhausted.
2. in a clean room, air introduced to the secondary air system for ventilation,
pressuri0ation, and replacement of exhaust air.
outdoor air
air outside a building or ta$en from outdoors and not previously circulated through the
system.
outside air
external air; atmosphere exterior to refrigerated or conditioned space; ambient
surrounding! air.
primary air
1. any air that is mixed with fuel at or in a burner prior to burning.
2. treated air introduced to a terminal device, where it mixes with room air circulated
by induction or fan power.
#. in a clean room, air that recirculates through the wor$ space.
recirculated air
air ta$en from a space and returned to that space, usually after being passed through
a conditioning system.
return air
air extracted from a space, and totally or partially returned to an air conditioner,
furnace, or other heat source. Compare recirculated air.
saturated air
1. air in which the partial pressure of the water vapor is equal to the vapor pressure of
water at the existing temperature.
2. air that holds the maximum water vapor possible at a specified temperature and
pressure.
secondary air
1. air for combustion supplied to the furnace to supplement the primary air after
ignition!.
2. primary air recirculated through an induction unit.
standard air I2>!
dry air at /,)6 and 1'.-*- psia. 8nder these conditions, dry air has a mass density of
,.,/( lb.ft#. %his is not the same as &I standard air.
standard air &I!
dry air at 2,)C and 1,1.#2( $>a absolute. 8nder these conditions, dry air has a mass
density of 1.2,' $g.m#. %his is not the same as I2> standard air.
supersaturated air
humid air that contains in a unit mass of dry air a mass of water vapor greater than
would be contained in saturated air at the same temperature; the excess water may
remain in the form of fog.
supply air
air entering a space from an air2conditioning, heating, or ventilating apparatus.
air age age of air!
time of passage of air from one point to another within an indoor space. &ee also airchange
effectiveness.
average age of air
average of local mean ages of air measured throughout an indoor airspace.
local mean age of air
average time for air to travel from an inlet to any point, >, in an indoor space. 9ote:
%he local mean age of air will be different at different points in the indoor space.
airborne sound
sound which reaches the point of detection by radiation through the air.
air2bound system
introduction of air causing either a flow restriction or a malfunction of the system.
air changes
expression of the amount of air movement or air lea$age into or out of a building in
terms of the number of building volumes or room volumes exchanged.
air2change effectiveness
average age of air that exits a building via all routes, divided by the arithmetic average
of the local ages of air, measured at breathing height. &ee also ventilation effectiveness.
building air2exchange effectiveness
arithmetic average of air that exits a building via all routes, divided by the building
mean age of air.
air change rate
airflow in volume units per hour divided by the building space volume in identical
volume units ?normally expressed in air changes per hour 4C< or 4C><!@. Aean air
change rate over a specific period can be measured using 4&%A = /'12+#, B%est
Aethod for 7etermining 4ir Cea$age 1ate by %racer 7ilution.D &ee also ventilating rate.
air circulation
motion of air, either natural or induced.
forced air circulation
movement of air by mechanical means.
air circulation rate air circulation ratio!
volume of air circulated within a closed space per unit time divided by the volume of the
space.
air cleaner
device used to remove airborne impurities from air. Compare filter. &ee also precipitator.
air.cloth ratio feet per minute!
value used in dust collector calculations to measure air velocity through the bag filter
media. 9ote: Calculated by dividing active cubic feet per minute of airflow by the
effective area square feet! of the cloth media.
air.media ratio
same as air.cloth ratio, but used where noncloth bag media, such as paper cartridges,
are the filter media.
air conditioner
assembly of equipment for the simultaneous control of air temperature, relative
humidity, purity, and motion. Compare air2conditioning system.
air2cooled air conditioner
one whose refrigerating system has an air2cooled condenser.
console air conditioner
pac$aged air conditioner mounted in a console, the condenser being water2cooled or
air2cooled; the air inta$e passes through the wall.
free2blow air conditioner free2delivery2type unit!
one which ta$es in air, treats it, and discharges it bac$ to the space being conditioned
without external ducts.
pac$aged air conditioner self2contained unit!
complete air2conditioning unit including refrigeration compressor, cooling coils, fans,
filter, automatic controls, etc. assembled into one casing. Compare air2conditioning
system ?pac$aged terminal air2conditioning system ptac!@.
roof2top air conditioner
pac$aged air conditioner mounted on a roof, the conditioned air being discharged
directly into the rooms below or through a duct system.
room air conditioner
pac$aged air conditioner designed for free air delivery of conditioned air, usually
mounted in window frame or in wall opening.
through2the2wall air conditioner
two2component air conditioner split2system!; its elements mounted on each side of a
wall and in2line with each other. Compare pac$aged air conditioner.
unitary air conditioner
one or more factory2made assemblies which normally may include an evaporator or
cooling coil, a compressor and condenser combination, and may include a heating
function.
unitary spot air conditioner
unitary air conditioner that cools a 0one within a space and discharges the re"ected
heat bac$ into that space. 4ir leaving the evaporator and condenser is discharged into
the same space, and there is no physical boundary separating these discharges.
water2cooled air conditioner
one whose refrigerating system has a water2cooled condenser.
window air conditioner
room air conditioner designed for mounting in window.
0one air conditioner
one which conditions the air of ad"acent rooms having similar requirements.
air conditioner capacity
useful net! available refrigerating capacity of an air conditioner for removing sensible
and latent heat from the space being conditioned.
useful latent air conditioner capacity dehumidifying!
available refrigerating capacity of an air conditioner for removing latent heat from the
space being conditioned.
useful sensible air conditioner capacity
available refrigerating capacity of an air conditioner for removing sensible heat from
the space being conditioned.
useful total air conditioner capacity
available refrigerating capacity of an air conditioner for removing sensible and latent
heat from the space being conditioned.
air conditioning process
in enclosed spaces, combined treatment of the air to control, as specified, temperature,
relative humidity, velocity of motion, and radiant heat energy level, including
consideration of the need for removal of airborne particles and contaminant gases.
&ome partial air conditioners that may not accomplish all of these controls are selected
for their capability to control specific phases of air treatment.
comfort air conditioning
treating air to control its temperature, relative humidity, cleanliness, and distribution to
meet the comfort requirements of the occupants of the conditioned space.
industrial air conditioning process air conditioning!
air treatment for an industrial process rather than for the comfort of occupants.
marine air conditioning
air conditioning applied on board ships for passengers or crew accommodations.
residential air conditioning
air conditioning as applied to private houses or apartments.
summer air conditioning
treating of air in a space when outdoor temperature or relative humidity outdoor drybulb
temperature or outdoor humidity ratio!, or both, are above those desired in the
space.
winter air
treating of air in a space when outdoor temperature and relative humidity outdoor drybulb
temperature or outdoor humidity ratio!, or both, are below those desired in the
space.
air2conditioning system
assembly of equipment for air treatment to control simultaneously its temperature,
humidity, cleanliness, and distribution to meet the requirements of a conditioned space.
&ee air conditioner. Compare air2conditioning process.
all2air air2conditioning system
air2conditioning system in which the thermal energy is carried from the central plant by
the air itself as against those systems in which another fluid transmits its energy to the
air at the points of usage.
central fan air2conditioning system
system in which air is treated at a central plant and carried to and from the rooms by
one or more fans and a system of ducts.
cooling heating! air2conditioning system
specific air2treating combination, which may consist of means for ventilation, air
circulation, humidity control, air cleaning, and heat transfer, with control means for
cooling heating!.
dense air system
old air system maintained under pressure greater than atmospheric in which air is
compressed, heat of compression dissipated, and the air, chilled by expansion and
performance of wor$, can create useful refrigeration.
dual2duct air2conditioning system
system of a central plant that produces conditioned air at two temperatures and
humidity levels, to supply air through two independent duct systems to the points of
usage where mixing may be carried out.
four2pipe air2conditioning system
multi2piping arrangement in which each unit is fitted with supply and return pipes
separately for hot and chilled water.
low2pressure air2conditioning system
system designed to have low pressure losses through the components of the
distribution system.
modular air2conditioning system
on2site assembly of prefabricated components, each with a functional role in air
conditioning air circulation, air filtration, cooling, heating, humidification, etc.!.
pac$aged terminal air2conditioning system ptac!
self2contained air2conditioning system for through2the2wall installation. 9ote: 4 ptac
often uses a wall sleeve.
self2contained air2conditioning system
single pac$age! air2conditioning unit having the means for air circulation and heat
removal, air cleaning, and the controls thereof, in the same cabinet.
single2duct air2conditioning system
system in which the air, having been conditioned in a central plant, is distributed to
various 0ones through a single duct.
split air2conditioning system
air2conditioning system consisting of equipment provided in more than one assembly
or enclosure, usually with supply air distribution equipment housed separately from
refrigerant condensing equipment.
three2pipe air2conditioning system
multi2piping arrangement in which each unit is fitted with two supply pipes hot and
chilled water! and a single return pipe common to the central heater and refrigerating
system.
air consumption
maximum rate at which air is consumed, under steady2state conditions, by a device
operating within its design limits.
air contaminant
unwanted airborne constituent that may reduce acceptability of the air.
dust
solid particles, smaller than 1,, micrometres, pro"ected into air by natural forces, or by
mechanical processes.
fog
fine airborne droplets usually formed by condensation of vapor.
fume
solid particles formed by condensation of vapors of solid materials. 9ote: >opularly,
the term BfumesD refers to any $ind of air contaminant; and many laws and regulations
add a qualification that the contaminant have some unwanted action.
mist
small airborne droplets of materials, ordinarily liquid, at normal temperatures and
pressure.
smog
commonly refers to air pollution. 4ir mixture of smo$e particles, mists, and fog droplets
of such concentration and composition as to impair visibility, in addition to being
irritating or harmful.
smo$e
1. small solid and.or liquid particles produced by incomplete combustion of organic
substances, varying in si0e often in the range of ,.1 to ,.# micrometre.
2. airborne solid and liquid particulates and gases evolved when a material undergoes
pyrolysis or combustion. 9ote: Chemical smo$es are excluded from this definition.
air cooler cooling unit; unit cooler!
encased assembly in which the temperature of air passing through it is reduced.
dry air cooler
cooler that removes sensible heat from dehydrated air.
dry2type air cooler
forced circulation air cooler wherein heat transfer is not implemented by a liquid spray
while in operation.
forced circulation air cooler
cooler which uses a fan or a blower for positive air circulation.
free delivery2type air cooler
cooler ta$ing air from and discharging it directly to the space to be treated without
ductwor$ external to the cooler that might impose air resistance.
natural convection air cooler
one depending on natural convection for air circulation.
sensible2heat air cooler
one having a surface temperature higher than the dew point of the entering air.
spray2type air cooler
forced2circulation air cooler, in which the coil surface is augmented by a liquid spray
during operation.
wet2type air cooler
unit bringing air in contact with liquid by bubbling through the liquid or spraying liquid
into it.
air curtain
controlled stream of air moving across the height and width of an opening with sufficient
velocity and volume to reduce the infiltration or transfer of air from one side of the
opening to the other; and to inhibit insects, dust, and debris from passing through; or
both.
air2curtain unit
mechanical air2moving device designed to produce an air curtain.
air diffusion performance index 47>I!
single number rating of the air diffusion performance of a system of diffusers, as
installed, at a specified air delivery rate, temperature, and moisture content.
air distribution envelope
surface or locus of points of equal velocity which describes an air distribution profile.
air drop
vertical distance between the base of an air outlet and the bottom of the airstream at the
end of the air throw. 9ote: 7rop occurs from the natural expansion of the airstream.
air dumping
rapid falling of cold air that occurs when a variable air volume E4E! box or other device
reduces airflow, and the supply air leaves the diffuser at very low velocity.
air eliminator air vent!
in a steam or water distribution system, a device which closes if either steam or water is
present in the vent body, and opens when air or noncondensables reach it.
air entrainment
capture of part of the surrounding air by an airstream discharged from an outlet;
sometimes called secondary air motion.
air handling unit
device, usually connected to ductwor$, to move air, which also may clean and condition
the air. &ee also ventilator.
central2station air2handling unit
factory2made, encased assembly consisting of the fan or fans and other necessary
equipment, designed to perform one or more of the functions of circulating, cleaning,
heating, cooling, humidifying, dehumidifying, and mixing of air; does not include a
source of heating or cooling.
cooling2heating unit
unit that includes means for cooling and heating, and which may also include means
for other air2handling unit functions.
cooling unit
unit that includes means for cooling and which may also include means for other airhandling
unit functions.
heating unit
unit that includes means for heating, and which may also include means for other airhandling
unit functions.
ma$eup air unit
factory2assembled fan2heater unit used to supply tempered fresh air to ma$e up for air
exhausted. Centrifugal or axial fans are utili0ed with direct gas2fired, steam, electric,
or water heater sections.
ventilating unit
unit with means to provide ventilation, and which may also include means for other airhandling
unit functions.
air heater, forced convection unit heater!
assembly of a heating element and a distribution fan.
air horsepower
air power expressed in horsepower.
air infiltration building!
uncontrolled inward lea$age of air that may contain entrained water vapor! through
crac$s and interstices in any building element and around windows and doors of a
building, caused by the pressure effects of wind or the effect of differences in the indoor
and outdoor air density. &ee also specific infiltration ratio!.
lea$age area
equivalent amount of open area assuming unit discharge coefficient! that would let
pass the same quantity of air as would pass collectively through the building envelope
at a reference pressure of ' >a ft2! ?m2@ ,.,1- in. of water!.
lea$age class
one of ten divisions of airtightness based on normali0ed lea$age.
neutral pressure level
neutral 0one! building height at which there is no difference between inside and
outside building air pressure.
normali0ed lea$age
dimensionless value calculated from the lea$age area, building height, and floor area
that describes the relative airtightness of the building.
air inlet core area
total plane area of the portion of a grille, face, or register bounded by a line tangent to
the outer edges of the outer openings through which air can pass.
air inlet free area
1. total area through which air can pass in a grille face or register.
2. actual open area between the fins of a grille or register.
air loc$
compartment whose purpose is to control air exchange into or out of a conditioned
space. %wo individual closures usually are used to restrict air transfer by $eeping one of
them closed.
air main
1. supply line from air compressor or central pressure2reducing station to branch feeder
in a pneumatic control installation.
2. tube carrying the supply of compressed air to the components of a pneumatic control
system.
#. pipe carrying air to the laterals supplying ice cans contained in a free0ing tan$.
air mass
totality of gas molecules in a defined volume of air.
air motor
1. device which converts compressed air into mechanical force.
2. air2operated device that is used primarily for opening or closing dampers.
#. pneumatic operator, a final control device that assumes a position as directed by an
input2pressure signal.
air outlet distribution outlet!
see also air supply fixtures.
ceiling outlet
round, square, rectangular, or linear air diffuser in the ceiling which usually provides a
hori0ontal distribution pattern of primary and secondary air over the occupied 0one
and induces low velocity secondary air motion through the 0one.
no00le outlet
discharge opening suitably shaped to produce a "et of air or other fluid, of regular form
and given throw.
slotted outlet
long, narrow air distribution outlet, comprised of deflecting members, located in the
ceiling, side2wall, or sill, with an aspect ratio greater than 1,, designed to distribute
supply air in several directions and planes, and arranged to promote mixing of primary
air and secondary room air.
vaned outlet
register, or grille, equipped with vanes to direct the flow of air, or control the rate of
flow.
air pollution concentration
olf
unit for quantifying the source strength of air pollution. Fne olf is the emission rate of
air pollutants bioeffluents! from a standard person.
decipol
unit for quantifying perceived air pollution. Fne decipol is the pollution caused by one
standard person one olf!, ventilated by 1, C.s of unpolluted air
?1 decipol 5 ,.1 olf C.s!@.
air power operational!
power required to move air at a given rate of flow against a given resistance. %he ratio
of air power to input power of a fan or blower is termed Befficiency.D
air power theoretical!
power required to drive a fan or blower as though there were no losses in the fan or
blower 1,,G efficiency!.
air separation air fractionation!
separation of the various components of air through distillation at very low temperature.
air separation unit
device used to remove air from another fluid stream. &ee also purge.
air spread
divergence of an airstream after it leaves an outlet.
air splitter
blade or blades fitted across an air duct to divide the airstream into a number of streams
in parallel. &ee turning vane.
air supply fixtures
devices or openings through which air flows into a room. &ee air outlet; diffuser; grille;
perforated ceiling; register.
air terminal device
device e.g., a grille! placed in a duct opening to a room, through which controlled air
enters or leaves. &ee also E4E box.
air throw blow!
hori0ontal or vertical axis distance an airstream travels after leaving an air outlet before
the stream velocity is reduced to a specific, so2called terminal value.
airtightness
qualitative term describing the integrity of the building envelope relative to air
permeation; the resistance of the building envelope to the flow of air and entrained
moisture. Compare air infiltration.
air velocity
rate of motion of air in a given direction, measured as distance per unit time. &ee also
velocity.
face air velocity frontal velocity!
axial velocity of the air entering or leaving a given effective face area.
air vent
manual or automatic device for removing air from circulating hot or chilled water
systems; also used for removing air from steam systems.
air washer
unit for spraying or atomi0ing clean water into an air supply system; capable of heating,
cooling, humidifying, or dehumidifying the air, depending on whether the water is heated
or chilled. &ee scrubber.
capillary air washer
enclosure with an assembly of cells pac$ed with fibrous materials over which water is
sprayed and through which air is passed to clean it.
spray2type air washer
enclosure in which water is sprayed by no00les into the airstream to wash it.
alarm
1. signal, either audible or visual or both, which alerts an operator to an off2normal
condition which requires some form of corrective action.
2. off2normal condition such as a pressure, temperature, etc., that has deviated above
or below an established operating range.
maintenance alarm
alarm designed to alert operating personnel that maintenance is required.
alarm point
that point in the range of a variable which is the threshold of an off2normal condition.
albedo
ratio of reflected solar radiation from a surface and the incident solar radiation. &ee also
reflectance.
algae
minute freshwater plants which form a scum on the surfaces of recirculated water
apparatus, interfering with fluid flow and heat transfer.
algaecide
any substance inhibiting the growth of algae.
algorithm
prescribed set of well2defined rules, or process, for the solution of a problem in a finite
number of steps, e.g., a full statement of an arithmetical procedure for evaluating sine x
to a stated precision.
alpha H factor
effective area of an air terminal, equal to the measured airflow rate divided by the
velocity reading of a particular instrument used in a prescribed manner.
ampacity
ability of a wire to carry electric current safely without undue heating. 6ormerly current
capacity.
ampere 4!
unit of electric current.
full2load amperes
1. current that a rotating machine will draw from the power line when the machine is
operating at rated voltage, speed, and torque.
2. current in amperes through a device when at maximum demand. 9ot to be confused
with inrush amperes at start2up! or stall amperes wor$ exceeds rating!.
amplifier
1. circuit used to increase the power, voltage, and.or current level of a signal.
2. device whose output is an enlarged reproduction of the essential features of an input
signal and which draws power from a source other than the input signal.
#. device that enables an input signal to control power from a source independent of the
signal and thus be capable of delivering an output that bears some relationship to,
and is generally greater than, the input signal.
analog display
1. display of analog data values. continued on next page!
2. display of a physical variable in a continuous form.
analog indication
analog display; e.g., a meter, or gage, which shows an analog value to an operator.
analy0er
device in the high side of an absorption system for increasing concentration of
refrigerant in the vapor entering the rectifier or condenser.
anechoic termination
device placed at the end of a test duct to prevent excessive reflection of the sound
waves bac$ into the test duct where they would interfere with the waves to be
measured.
anemometer
device to sense and measure velocity of airflow at a point.
acoustic anemometer
device to sense velocity of air at a point by use of the 7oppler effect on the velocity of
sound. It may also sense temperature.
cup anemometer
device with several often hemispherical! cups attached to the ends of symmetrical
radial arms that rotate by air motion wind! at a speed proportional to the wind velocity.
deflecting2vane anemometer
device containing a pivoted vane that rotates within its casing from the force of air
moving through the casing so that the indicated tension in a coil spring, with damping,
is related to the velocity of the air at that instant; useful in evaluating air velocities in a
room and indicating sources of drafts.
digital anemometer
generally a revolving vane anemometer the shaft of which provides impulses electric,
magnetic, etc.! which are pic$ed up by an electronic circuit and transmitted to the
indicating apparatus.
electronic anemometer
device sensitive to air movement past an electronic circuit to measure air velocity.
mechanical anemometer
mechanical instrument which directly measures air velocity; a device which is
sensitive to air movement with a calibrated airspeed measuring dial.
revolving vane anemometer
device consisting of rotating propeller2type vanes; the air velocity is indicated from the
rotational speed of the vanes.
thermal anemometer
device that relies on the cooling effect of the airflow to change the temperature of a
heated body in proportion to the airspeed. %ypes include hot2wire anemometer,
heated bulb thermometer, heated thermocouple anemometer, and heated thermistor
anemometer.
aneroid capsule
thin, dis$2shaped box or capsule, usually metallic, partially evacuated and sealed, held
extended by a spring, which expands and contracts with changes in atmospheric or gas
pressure.
angle of discharge
largest included angle between centerlines of principal "ets of primary air.
angle of incidence
angle between the direct solar irradiance and the normal to the aperture plane.
anion
ion that is negatively charged; e.g., chloride, silicate, sulfate. Compare cation.
annealing
1. process involving controlled heating and subsequent controlled, generally slow,
cooling; applied usually to induce ductility in metals.
2. treatment intended to remove internal stresses, alter mechanical or physical
properties, produce a definite microstructure, and remove gases.
annunciation
1. an BalertD to an operator. 9ot to be confused with alarm, the operator is informed of a
change in a system. %his change could require an alarm but not necessarily.
2. displaying of a condition by a visual or audible means.
anode
positive electrode in an electrolytic system, such as applied in cathodic protection. %he
electrode at which oxidation or corrosion occurs, or from which the current is
transmitted to the electrolyte. Compare cathode.
antibiotic
substance produced by a living organism i.e., fungi, bacteria! that inhibits the growth of,
or $ills, another living organism. Compare bactericide.
appliance vent connector
portion of the venting system that connects the gas appliance or its draft hood to the
chimney or vent terminal.
appliance vent pipe
passage or conduit in a direct vent or direct exhaust system through which gases pass
from the combustion chamber to the outdoor air.
application rating
rating based on tests performed at stated application conditions other than standard
rating conditions.
approach
1% in heat e&$han'ers( temperat!re differen$e "etween the #ea)in' f#!ids%
2. in a water cooling tower or evaporative cooling device, the difference between the
average temperature of the circulating water leaving the device and the average wetbulb
temperature of the entering air.
architectural area of a building!
the sum of the areas of the several floors of the building, including basements,
me00anine and intermediate floored tiers, and penthouses of headroom height,
measured from the exterior faces of exterior walls or from the centerline of walls
separating buildings. 9ote: 7iscretion is advised in calculating areas of interstitial
space; covered wal$ways, open roofed2over areas that are paved, porches, and similar
spaces shall have the architectural area multiplied by an area factor of ,.(,; the
architectural area does not include such features as pipe trenches, exterior terraces or
steps, chimneys, and roof overhangs.
architectural volume of a building!
cube or cubage! the sum of the products of the architectural areas using the area of a
single story for multistory portions having the same area on each floor! and the height
from the underside of the lowest floor construction system to the average height of the
surface of the finished roof above for the various parts of the building.
artificial intelligence 4I!
capability of a device to perform functions that normally are associated with human
intelligence, such as reasoning, learning, and self2improvement. &ee also expert
system; neural networ$.
4&<14= atmospheric dust spot efficiency
measure of the ability of a device to remove atmospheric dust from the test air.
4&<14= arrestance
measure of the ability of a device to remove 4&<14= atmospheric dust from test air.
4&<14= synthetic arrestance dust
compounded test dust used for arrestance measurement and for loading filters.
aspiration
production of movement in a fluid by suction created by fluid velocity. &ee also venturi.
athermour barrier
substance or space that does not allow the passage of radiant heat.
atmosphere of reference
reference atmosphere, the characteristics of which are defined by standards for given
purposes.
atmospheric dust
particulate matter naturally occurring in the air supplied to the test duct. &ee also air
contaminant.
atomi0e
verb. to create a fine spray from a liquid.
authority of a controller!
ratio of effect on a manipulated variable of one input signal as compared to that of
another.
auxiliary air
supply or supplemental air delivered to a laboratory fume hood to reduce room air
consumption.
average specific infiltration
value of the specific infiltration that is typical for an average climate in the 8nited &tates
or Canada.
a0eotropic point
temperature at which a liquid mixture boils and produces a vapor having the same
composition as the liquid.
bac$flow
reverse flow in a water system from the normal or intended direction. 9ote: Iac$flow
generally is more evident in an open water system.
bac$flow preventer I6>!
device designed to prevent reverse flow in a water system. 9ote: %erm normally used
where bac$ pressure2type bac$flow is implied.
double2chec$ valve 7CE! bac$flow preventer
device designed for continuous or intermittent pressure where pollutants are involved.
double2detector chec$ 77C! bac$flow preventer
device designed to serve also as a detector chec$ on fire2protection systems where
pollutants are involved. 9ote: 77C includes a line2si0e, approved double2chec$ valve
bac$flow preventer with a metered bypass, into which has been incorporated a threequarter
inch, approved double2chec$ valve bac$flow preventer.
dual2chec$ 7uC! bac$flow preventer
device designed for containing water system to residences, mobile homes, etc., as a
second line of defense, and for isolating residential systems, such as lawn sprin$ler
systems, where pollutants are involved.
intermediate2atmospheric vent I4E! bac$flow preventer
small bac$2pressure and bac$ siphonage2type bac$flow2prevention device designed
to operate under continuous pressure, for use where certain quasi2contaminants are
involved.
reduced pressure 0one 1>J! bac$flow preventer
bac$ pressure and bac$ siphonage2type device designed to operate under continuous
pressure, where contaminants are involved.
reduced pressure2detector chec$ 1>7C!
bac$2pressure and bac$ siphonage2type device designed to serve as a detector chec$
on fire2protection systems where contaminants are involved. 9ote: 1>7C includes a
line2si0e approved, reduced pressure 0one bac$flow preventer with a metered
bypass, into which has been incorporated a three2quarter inch, approved reduced
pressure 0one bac$flow preventer.
bac$flow prevention
program, ordinance, or code designed to prevent bac$flow into a potable water system;
and to discover, to eliminate, to prevent all uncontrolled cross2connections, existing or
potential.
cross2connection control bac$flow prevention
first line of defense! installation of a bac$flow preventer, or a vacuum brea$er, at each
cross2connection on a premises, to protect both premises system and the main
system.
containment bac$flow prevention *se$ond #ine of defense+
installation of a bac$flow preventer at the service connection to a premises, to protect
the main water system only.
bac$flow2prevention device specialist
person qualified and certified to test and to repair bac$flow2prevention devices, and who
has proved competency to the applicable regulatory agency.
bac$flow2prevention device tester
person qualified and certified to test, but not to repair, bac$flow2prevention devices, and
who has proved competency to the applicable regulatory agency.
bac$ pressure
increase in pressure in a consumer water system, or a branch, above the pressure at
the service connection. 9ote: Iac$ pressure generally is caused by pumps, thermal
expansion, or reasons other than reduction or loss of incoming pressure. It generally is
more evident in a closed water system.
bac$ siphonage
reverse flow in a water system caused by negative pressure in an incoming pipe, when
the point of use is at atmospheric pressure. 9ote: Iac$2siphonage generally is more
evident in an open water system.
bac$2siphonage preventer
device, installed in a water system, designed to prevent reverse flow where negative
supply pressure occurs.
bacterial decay
food deterioration caused by microorganisms.
bactericide
chemical or physical agent capable of $illing bacteria.
bacteriostatic
property of a substance capable of inhibiting the growth of bacteria by causing bacteria
to form aggregations, without $illing them.
baffle
surface, usually in the form of a plate or wall, used for separating spaces or deflecting
fluids.
refrigerator baffle
plate, wall, or partition, which is designed to perform one or more of the following
functions: 1! prevent contact of food with refrigerated surfaces; 2! prevent dripping of
condensate on food; #! regulate and.or direct circulation of refrigerated air.
balancing station
assembly to measure and control fluid flow; composed of a measuring device, a volume
control device, and recommended lengths of straight ductwor$ or pipe leading into and
out of the measuring device.
ballast
electrical device used with an electric2discharge lamp to obtain the necessary circuit
conditions voltage, current, waveform! for starting and operating.
ballast losses
electric power watts! consumed internally by the ballast components.
barometer
device for measuring atmospheric pressure.
aneroid barometer
barometer in which the pointer is driven by a capsule containing no liquid. &ee aneroid
capsule.
barometric effect
variations in barometric pressure caused by altitude or weather changes.
base unit power density Pb!
maximum allowed power density, in K.ft2, for the listed areas.activities of an ideal space
prior to area factor ad"ustment.
bearing
machine part in which another part as a "ournal or pin! turns or slides.
footstep bearing
thrust bearing used to support the lower end of a vertical shaft.
needle bearing
type of roller bearing in which rod2li$e rollers have small diameters relative to their
lengths.
pedestal bearing
separate bearing mounted in a pedestal and located ad"acent to a reciprocating
compressor to provide support, e.g., for an overhung flywheel.
roller bearing
bearing consisting of a number of rollers in a cage between the inner and outer races.
sleeve bearing
bearing consisting of one or more solid tubular pieces of material of low coefficient of
friction.
thrust bearing
bearing designed to withstand an axial load. Compare thrust collar.
bellows
1. flexible corrugated chamber which converts pressure variation into mechanical
movement.
2. flexible fluid2containing vessel that will expand or contract as a result of a change in
the pressure of the contained fluid. Can be used to transmit force and.or motion in a
pneumatic or hydraulic system or as a sensor of temperature or pressure when the
bellows is sealed.
bias
tendency of an estimate to deviate in one direction from a true value a systematic
error!. &ee error. Compare precision.
bimetallic element
actuating element consisting of two strips of metal with different coefficients of thermal
expansion attached so that internal strains caused by temperature changes bend the
compound strip to open or close contacts, or a pneumatic device.
bin
in the bin method, a statistical class or category sometimes class interval! for outdoor
air temperature, with the class limits expressed in a temperature unit.
bin method
energy calculation method, usually used in prediction, in which the annual or
monthly! energy use of a building is calculated as the sum of the energy used for all of
the outdoor temperature bins. %he bin method allows heat pump or other heater or
cooler! performance, which is different for each bin, to be accounted for.
binary
characteristic or property involving a selection, choice, or condition in which there are
two possibilities as binary numbers in a computer, on2off, or open2closed switch
position!.
blac$body
1. body that absorbs all the radiant energy falling on it.
2. body that has the maximum theoretical radiant energy emittance at a given
temperature. &ee also absorber.
blast gate
heavy2duty duct closure device.
bleeder
pipe attached to a unit, as a condenser, to bleed off liquid refrigerant parallel to main
flow.
blowdown
1. discharge of water from a steam boiler or open recirculating system that contains
high total dissolved solids. %he addition of ma$eup water will reduce the
concentration of dissolved solids to minimi0e their precipitation.
2. in pressure2relief devices, the difference between actuation pressure of a pressurerelief
valve, and reseating pressure, expressed as a percentage of set pressure, or in
pressure units.
boiler
vessel in which a liquid is heated with or without vapori0ation; boiling need not occur.
cast2iron sectional boiler
assembly of individual hollow cast2iron sections connected with push nipples, external
headers, or internal seals.
fire2tube boiler
boiler with straight tubes surrounded by water through which tubes pass the products
of combustion.
high2pressure boiler
1. boiler for generating steam at pressure in excess of 1( psig ?1,#.' $>a gage!@.
2. hot2water boiler intended for operation at pressures exceeding 1-, psig ?11,, $>a
gage!@ and.or temperatures exceeding 2(,)6 12,)C!.
hot water supply boiler
boiler completely filled with water that furnishes hot water to be used externally to
itself at pressures not exceeding 1-, psig or at temperatures not exceeding 2(,)6
12,)C! at or near the boiler outlet.
low2pressure boiler steam or hot water!
electric, gas, or oil2burning appliance designed to supply low2pressure steam or hot
water for space heating application. 4 low2pressure steam boiler operates at or below
1( psig ?1,# $>a gage!@ steam pressure; a hot water boiler operates at or below 1-,
psig ?11,, $>a gage!@ water pressure and 2(,)6 12,)C! water temperature.
modular boiler
boiler designed and constructed to include increments of capacity as required for the
installation.
pac$aged boiler
boiler shipped complete with heating equipment, mechanical draft equipment,
automatic controls, and accessories; usually shipped in one or more ma"or sections.
&cotch boiler
fire2tube boiler consisting of a cylindrical shell with one or more cylindrical internal
furnaces in the lower portion, and a ban$ of tubes attached to both end closures.
steam boiler
enclosed vessel in which water is converted into steam.
water2tube boiler
boiler in which tubes contain water and steam, with heat applied to their outside
surfaces.
boiler2burner unit
boiler designed especially for gas and oil and sold integrally with the burner.
boiler capacity
design maximum rate of heat output.
boiler crown sheet
part of a boiler forming the top of the furnace in a firebox boiler, or the equivalent
surface in other types.
boiler feedwater
water supplied to a boiler by pumping.
boiler feedwater heater
apparatus for raising the temperature of the boiler feedwater, usually with exhaust
steam.
boiler foaming
carryover of slugs of water into the piping from overloading of the boiler. Compare boiler
priming.
boiler generator
part of an absorption machine in which the refrigerant vapor is driven off by heat.
boiler heating surface
surfaces of the boiler which are exposed to the products of combustion on one side and
water on the other, expressed in area units of the side receiving the heat!.
boiler horsepower
e,!i)a#ent e)aporation of 3-%5 #"% of water per ho!r from and at 212)6% .his is e,!a# to
heat o!tp!t of 97/%3 ⋅ 3-%5 0 33(-75 1t!2h( appro&imate#y 93/9%5 4%
boiler priming
carryover of boiler water with the steam, due to insufficient steam space, faulty boiler
design, or operating conditions. Compare foaming.
boiler rating
design maximum rating of a steam or water boiler expressed as the total heat
transferred by the heating surfaces in Itu.h. &ometimes expressed in horsepower or
pounds of steam per hour.
boiler water leg
space which contains water, between the outer shell and furnace shell.
boiler waterline
level at which water is maintained within a steam boiler.
boiler water temperature control
device that senses boiler water temperature and controls boiler burner operation.
boiling ebullition! process
vapori0ation of a liquid with formation of bubbles.
nucleate boiling
boiling in which bubble formation is at the liquid2solid interface rather than from
external or mechanical devices.
pool boiling
ebullition on a heated surface in contact with a liquid mass which is not agitated
except by the process itself.
boil2off gas
liquefied gas lost by vapori0ation during storage in a tan$.
bolometer
sensitive thermal device for measuring radiant energy.
bonding electrical ground!
connection to ground potential of a metal part on an appliance or component which may
become energi0ed by an electrical fault, or develop a static charge.
booster
accessory to increase output of, for example, a compressor or a pump, or a header.
boot
sheet metal transformation piece used to ma$e connection between round and
rectangular ductwor$.
boundary conditions
physical conditions values of physical quantities, conditions of energy interchange,
etc.! imposed on a system at the boundaries separating the system from its
surroundings.
boundary layer
region of retarded fluid2flow near the surface of a body moving through the fluid, or past
which the fluid moves. &ee also flow boundary2layer flow!.
bra$e horsepower
bra$e power expressed in horsepower.
bra$e power
actual power delivered by or to a shaft from the use of a bra$e to measure power!.
branch
1. in ducts, piping, or conduit; another section of the same si0e or smaller, at an angle
with the main.
2. section of pipe from a main to a register or radiator.
#. computer! a set of instructions that are executed between two successive decision
instructions.
branch circuit
electrical wiring between the last overcurrent protection device and the connected
outlets.
branch line
air supply line connecting a controller and controlled device.
bra0e
verb. to "oin metals by fusion of nonferrous alloys that have melting points above +,,)6
'2()C!, but lower than those of the metals being "oined. Aay be accomplished by
means of a torch torch bra0ing!, in a furnace furnace bra0ing!, or by dipping in a
molten flux bath dip or flux bra0ing!.
bra0ed
ad". "oined by fusion using a spelter of brass; considered equivalent to hard soldering.
brea$er
1. brea$er strip, a relatively poor conductor of heat used to "oin the inner and outer shell
of an internally refrigerated container such as a refrigerator.
2. device designed to interrupt the current of an electrical circuit during an overcurrent
condition and also used as a disconnecting means for a load.
breather plug
removable plug, cap, or other means of venting a space containing insulating material
through vaportight sheathing.
breeching
passage for conducting the products of combustion from a fuel2fired appliance to a vent
or chimney.
brine
1. formerly any liquid cooled by a refrigerant and used for heat transmission without a
change in its state, having no flash point or a flash point above 1(,)6 --)C!. 9ow
called a secondary coolant.
2. secondary coolant that is a solution of salt in water. 4&A= I#1.(!. &ee coolant.
Iritish thermal unit Itu! an I2> unit!
heat ener'y in a 1t!% Re#ated thro!'h spe$ifi$ heat to the Internationa# .a"#e $a#orie so
that 1 $a#2*5'67+ 0 1 1t!2#"6)8 for 1 #" 0 -53%592 37 '% .he 8ifth Internationa#
Conferen$e on the 9roperties of Steam *195:+ defined the Internationa# .a"#e $a#orie as
-%13:3 ;% .herefore( the Internationa# .a"#e 1t! is e&a$t#y 1 /55%/55 352 :2 ;% .he
me$hani$a# e,!i)a#ent ener'y of a 1t! is appro&imate#y 773%1:9 2:2 ft⋅ #"% .he heat
ener'y of a 1t! is appro&imate#y that re,!ired to raise the temperat!re of a po!nd of
water from 59 to :/)8%
buffer
1. computer! digital circuit element used to increase fan2out the number of outputs a
circuit can drive! or to convert input or output levels for signal level compatibility.
4lso, any isolating amplifier stage.
2. salts or other compounds that reduce the changes on the p< of a solution upon the
addition of an acid or al$ali.
#. storage device used to compensate for a difference in rate of flow or data or time or
occurrence of events when transmitting data from one device to another.
'. insulating circuit used to avoid reaction of a drive circuit on any driven circuit.
building area
area included within surrounding exterior walls or exterior walls and fire walls.area
separation walls! exclusive of courts. %he area of the building not provided with
surrounding walls is the usable area under the hori0ontal pro"ection of the roof or floor
above. Compare architectural area.
building envelope
outer elements of a building, including walls, windows, doors, roofs, and floors,
including those in contact with earth.
building thermal envelope
elements of a building which enclose spaces, and which control or regulate heat and
mass transfer air, water vapor, and entrained moisture! between the interior spaces
and the building exterior. 9ote: %he interior surfaces of insulated floors, walls,
windows, and ceilings generally comprise the thermal envelope. &ee air infiltration.
building envelope opaque areas
all exposed areas of a building envelope which enclose space, except openings for
windows, s$ylights, doors, and building service systems; i.e., all areas of a building
envelope which permit passage of radiant energy in or out of the building space.
building envelope void
any locali0ed area of the building envelope which has a thermal resistance significantly
different from the area surrounding it. %he void may be due to partial or complete
absence of thermal insulation.
building height
vertical distance from level grade or average grade to the highest finish roof surface in
the case of flat roofs, or to a point at the average height of the highest roof having a
pitch.
building management system electric!
energy management system, usually with additional capabilities, relating to the overall
operation of the building in which it is installed, such as equipment monitoring,
protection of equipment against power failure, building security, etc.
building power2line carrier >CC!
method of transmitting control signals using existing electrical wiring. &ignals are
introduced by superimposing on, or altering, existing waveforms. &ignals are sensed by
detecting these modifications of the waveforms with a remotely controlled receiver. 4
building >CC uses relatively low communication energy of low radio frequency,
generally between 1,, and (,, $ilohert0, to transmit and.or receive information
exclusively over secondary distribution lines whose primary purpose is the distribution
of electric power at user facility.
building volume
?of a building that exchanges air with the outside ambient! air cubic feet or cubic
metres!@ space that is deliberately conditioned for human comfort. &ee also
architectural volume.
bulb
1. glass envelope used in the assembly of an electric lamp or electron tube.
2. portion of a thermal2sensing system that is placed in the controlled or measured!
variable.
#. in botany, a modified underground stem, such as that of an onion or tulip. 9ote: &ome
bulbs are treated and stored in refrigerated conditions.
bun$er
space in refrigerator for ice or cooling element.
dry2ice bun$er
in a refrigerated vehicle, a compartment containing dry ice to $eep the load cooled.
refrigerated truc$ end bun$er end2bun$er refrigerated railcar!
a refrigerated vehicle, where the space given to the ice or cooling element is in the
end of the truc$ or rail car.
burner
part of a fuel2burning device as a stove or furnace! where flame is produced.
air atomi0ing burner
burner in which the oil is atomi0ed by compressed air which is forced into and through
one or more streams of oil, brea$ing the oil into a fine spray.
atmospheric burner
gas burner in which air for combustion is supplied by natural draft and the inspirating
force created by gas velocity through orifices.
conversion burner
burner intended for field installation which changes the fuel of an existing furnace or
boiler.
dual fuel burner
burner designed to burn either gas or oil but not both simultaneously.
forced draft burner
burner which has a fan capable of supplying all necessary air for proper combustion
with positive pressure in the firebox.
intermittent ignition burner
burner for which ignition is supplied initially to start, not continually, and at timed
intervals so long as combustion is required.
mechanical atomi0ing burner
burner supplied with fuel oil under pressure, causing self2atomi0ation.
natural2draft burner
burner which depends primarily on the natural draft created in the chimney or venting
system to induce the air required for combustion into the burner.
rotary2atomi0ing burner rotary cup burner!
burner in which atomi0ation is accomplished by feeding oil to the inside of a rapidly
rotating cup.
steam2atomi0ing burner
burner in which the firing oil is atomi0ed by steam.
vapori0ing burner
burner designed to utili0e the temperature of the heated combustion chamber to
vapori0e the liquid fuel fed into such chamber.
burner flame failure response time
interval between the occurrence of flame extinction and the activation of safety shutoffs.
burner ignition
1. initiation of combustion.
2. process or means of igniting a fuel2air mixture.
intermittent burner ignition
ignition source that is automatically ignited or energi0ed when an appliance is called
on to operate, and that remains continuously ignited or energi0ed during each period
of main burner operation 49&I &tandard J 21.1#!.
interrupted burner ignition
ignition source that is automatically ignited or energi0ed when an appliance is called
on to operate, and that remains ignited or energi0ed during the main flameestablishing
period. %he ignition source is automatically extinguished or deenergi0ed
when each main burner flame2establishing period is completed 49&I &tandard J
21.1#!.
burner low2fire setting
setting that determines the fuel firing rate at which burner ignition occurs where lowhigh2
low2off, or modulating combustion controls are used. %he firing rate corresponds to
approximately one2third or less of the full burner delivery rate for rotary burners. It
corresponds to approximately one2fifth or less of the full burner delivery rate of air for
mechanical atomi0ing burners.
burner register
series of air2directing vanes usually ad"ustable! that are used to direct and.or control
the combustion airflow through the burner.
burner throat
sleeve, usually formed of refractory, located at the burner exit, within which combustion
starts.
burner window box
device to introduce secondary combustion air into the furnace in a #-,) pattern around
the flame and, with an ignition cone, to cause accelerated vapori0ation of the oil.
bus electrical!
common portion of one or more conductors used for transmitting signals or power from
one or more sources to one or more destinations.
bypass
pipe or duct, usually controlled by a valve or damper, for conveying a fluid around an
element of a system.
C47 computer2aided design!
system in which engineering designs are created graphically on the computer screen,
or in the form of a computer printout.
C47.C4A
parts design and manufacturing method utili0ing a computer data base where drawings
are not needed. &ynonymous with computer2integrated manufacturing.
C477
computer2aided design and drafting.
calculated variable
1. variable that cannot actually be measured directly, but one which can be calculated
by measuring other variables. =xample: Aeasure wet2bulb temperature and
measure dry2bulb temperature to determine enthalpy.
2. variable which is calculated from one or more inputs.
calibration
correcting or determining the error of an existing scale, or of evaluating one quantity in
terms of readings of another.
calorie
heat required to raise the temperature of 1 gram of water 1)C; specifically from ' to ()C.
%he 6ifth International Conference on the >roperties of &team 1*(-! defined the
International %able calorie as '.1+-+ L. Aean calorie 5 1.1,, part of the heat required to
raise 1 gram of water from , to 1,,)C. Mreat calorie or $ilocalorie 5 1,,, calories%
calorimeter
1. device for measuring heat quantities, such as machine capacity, combustion heat,
specific heat, vital heat, heat lea$age, etc.
2. device for measuring quality or moisture content! of steam or other vapor.
#. equipment for measuring emitted or absorbed heat quantities.
compressor calorimeter
apparatus for determining the refrigerant flow rate, and subsequently, the capacity of a
refrigerant compressor by measuring the heat input required to balance the
refrigerating effect produced in the evaporator by the compressor.
condensing unit calorimeter
apparatus for determining refrigerant flow rate, and subsequently the capacity of a
condensing unit by measuring the heat input required to balance the refrigerating
effect produced in the evaporator by the condensing unit.
room calorimeter
1. generally, a room used for the measurement of quantities of heat energy.
2. test facility for small air conditioners, consisting of two contiguous calorimeters with
a common partition through which the air conditioner to be tested is mounted.
C4A computer2aided manufacture!
system in which a computer directs the manufacture and assembly of a product.
capacitance
property of an electric device or capacitor that permits storage of electric energy in an
electrostatic field, and the release of that energy at a later time.
capacitor condenser!
in an alternating electrical system, a device that will store an electric charge used to
change a power factor.
capacity
1. maximum load for which a machine, apparatus, device, or system is designed or
constructed.
2. measure of the maximum amount of energy or material that may be stored in a given
system. &ee also nameplate rating; air conditioner capacity; thermal storage capacity
integrated!.
gross capacity
load uncorrected! that a machine, apparatus, device, or system is designed to carry.
net capacity effective capacity!
1. capacity volume! of a room after deducting the loss of space due to coils, columns,
air ducts, dunnage, and other dedicated space required to provide air circulation.
2. equipment! maximum load that a machine, apparatus, device, or system is capable
of carrying under service conditions.
capacity reducer
in a compressor, a device, such as a clearance poc$et, movable cylinder head, or
suction bypass, by which compressor capacity can be ad"usted without otherwise
changing the operating conditions.
capillarity
action by which the surface of a liquid in contact with a solid as in a small bore tube! is
raised or lowered proportional to surface wetting.
carbonation
absorption of in"ected CF2 into a liquid, usually preceded or accompanied by liquid
cooling.
carbonator
apparatus for in"ecting CF2 into water for preparing carbonated beverages.
carboni0ation
formation of carbonaceous deposits which may be produced by decomposition of
lubricating oil or other organic materials.
cargo
freight carried by a ship, airplane, or other vehicle.
chilled cargo
cargo maintained at an assigned cold temperature above its free0ing point.
dry cargo
unrefrigerated cargo.
refrigerated cargo
cargo maintained at an assigned temperature by means of refrigeration.
cargo batten
series of protection members applied permanently to the interior of a refrigerated
compartment to provide airspace between the stowed cargo and the sides of the
compartment.
cargo dunnage
strips of wood or other suitable material used in stowing cargo to provide airspaces
between pieces, pac$ages, or between them and walls and floors.
carrier frequency
1. in a periodic carrier, the reciprocal of its period. 9ote: %he frequency of a periodic
pulse carrier often is called the pulse repetition frequency in a signal transmission
system.
2. modulated amplifier! the frequency that is used to modulate the input signal for
amplification.
cathode
negative electrode in an electrolytic system; e.g., 6eNN, CuNN, CaNN, AgNN. Compare
anode.
cathode2ray tube C1%!
1. electronic vacuum tube containing a screen on which information may be shown by
modulated beam of electrons a beam of cathode rays!.
2. electronic storage tube.
#. oscilloscope tube.
'. picture tube.
cathodic protection
technique to minimi0e corrosion of a metal surface by coating the cathodic surface of an
electrochemical cell.
cation
positively charged atom or group of atoms, or a radical that moves to the negative pole
cathode! during electrolysis. Compare anion.
cavitation
1. formation of cavities on a surface of a solid by liquid moving over it with velocity high
enough to induce erosion of the surface when the cavity collapses.
2. formation by mechanical forces of vapor in liquids; specifically, the formation of vapor
cavities in the interior or on the solid boundaries of liquids in motion, where the
pressure is reduced to a critical value without a change in ambient temperature.
cell in a cooling tower!
smallest tower subdivision which can function as an independent heat exchange unit. It
is bounded by exterior walls or partitions. =ach cell may have one or more fans or
stac$s and one or more distribution systems.
central processor
data processor which compiles, processes, and stores information gathered from
peripheral field gear.
C2factor thermal conductance!
time rate of steady2state heat flow through a unit area of a material or construction
induced by a unit temperature difference between the body surfaces. C 5 q.⊗%.
C6C
chlorofluorocarbon.
changeover
1. change from one set of controls to another.
2. change from heating to cooling, or vice versa.
automatic changeover
changeover from one operation to another without operator intervention; e.g., a
thermostat which changes from heat to cool without need for manual operation of
levers or set points.
manual changeover
changeover from one operation to another by means of operator intervention.
semiautomatic changeover
selection of heating or cooling operation by means of a combination of manual and
automatic switches, which usually are located at the room thermostat.
channel
1. output of a load2management system; usually corresponding to a specific relay.
2. computer! path along which signals can be sent, e.g., data channel, output channel.
#. portion of a storage medium that is accessible to a given reading station, e.g., trac$,
band.
charge thermal storage!
verb. to supply cooling or heating to storage.
load2leveling
charging a thermal storage system at a constant rate during a complete cycle.
charging connection
device to enable a refrigerating system to be charged with refrigerant. 4lso, the tube or
hose through which charging is accomplished.
chiller
1. refrigerating machine used to transfer heat between fluids.
2. complete, indirect refrigerating system of compressor, condenser, and evaporator
with all operating and safety controls.
absorption chiller
refrigerating machine using heat energy and absorption input to generate chilled
water.
mechanical chiller
refrigerating machine using mechanical energy input to generate chilled water.
spin chiller
rotary2type chiller for poultry, in which the birds are conveyed and tumbled in ice water.
chiller barrel
shell2and2tube evaporator used to cool water or a secondary coolant. 9ote: %erm
applies only to water2chilling pac$ages, not to heat exchangers.
chiller drip tray
drawer located directly beneath the refrigerated surfaces of a manual or semiautomatic
defrosting refrigerator for food chilling and.or water collecting during defrosting. It may
also serve as a baffle to regulate compartment temperature.
chiller drip tray volume
product of the mean inside width and length of the tray and the mean height between
the inside bottom of the tray and the outside bottom of the surface of the refrigerated
plate or coil when the tray is in its lowest position.
chill factor wind chill factor!
temperature of relatively calm ' mph or -.' $m.h! air that would produce the same chill
effect on bare flesh as the combination of wind and temperature.
contact icing
process of chilling in which finely crushed ice is placed in contact directly with the
product in its unpac$ed or pac$ed state.
chimney
one or more passageways, vertical or nearly so, for conveying flue gases to the outside
atmosphere.
low2temperature chimney
one intended to handle the products of combustion with a temperature at the point of
leaving equipment, of -,,)6 #1()C! or less under normal operating conditions.
medium2temperature chimney
one intended to handle the products of combustion, at the point of leaving equipment,
with a temperature between -,, to 1,,,)6 #2, to (',)C! under normal operating
conditions.
chlorofluorocarbon C6C!
generally any of several compounds comprised of carbon, fluorine, chlorine, and
hydrogen, used chiefly as refrigerants and as blowing agents in plastic foams. Compare
fluorocarbon; halocarbon.
fully halogenated chlorofluorocarbon
C6C compound in which all of the hydrogen atoms are replaced by chlorine and
fluorine atoms.
circuit
1. complete path of an electric current in or into a building, including usually the source
of electric energy.
2. assemblage of electronic components.
duplex circuit
1. circuit that has two separate sources of supply.
2. pair of circuits with either one usable when failure occurs in the other.
four2wire circuit
1. two2way circuit using two paths so arranged that the electric waves are transmitted
in one direction only by one path and in the other direction only by the other path.
9ote: %he transmission paths may or may not use four wires.
2. circuit that is fed from both ends of the line and enables any device to transmit bac$
with a single brea$ in both conductors.
refrigeration circuit
assembly of refrigerant2containing parts used in a refrigerating cycle.
simplex circuit
1. circuit derived from a pair of wires by using the wires in parallel with a ground
return.
2. single circuit.
two2wire circuit
metallic circuit formed by two ad"acent conductors insulated from each other. It is
possible to use the two conductors as a one2way transmission path, a half duplex
path, or a full duplex path.
clean room
specially constructed, enclosed area environmentally controlled with respect to airborne
particulates, temperature, humidity, air pressure, air pressure flow patterns, air motion,
vibration, viable organisms, and lighting.
as2built clean room
one that is complete and ready for operation, with all services connected and
functional, but without production equipment or personnel within the room.
at2rest clean room
one that is complete and has the production equipment installed and operating, but
without personnel within the room.
conventional flow clean room
one with non2unidirectional or mixed airflow patterns and velocities.
laminar flow clean room
one having airflow nominally in one direction.
operational clean room
one in normal operation with all services functioning, and with production equipment
and personnel present and performing normal wor$ functions.
clean room critical surface
in a clean room, the surface of the wor$ part to be protected from particulate
contamination.
clean room wor$station
open or closed wor$ surface in a clean room, with direct air supply.
laminar flow wor$station
one with airflow nominally in one direction through the wor$ area.
nonlaminar flow wor$station
one without uniform airflow patterns and velocities.
clean space
in a clean room, a defined area in which the concentration of airborne particles is
controlled within specified limits.
clearance
1. space in a cylinder not occupied by the piston at the end of the compression stro$e or
the volume of gas remaining in a cylinder at the same point, measured in percentage
of cylinder volume at the end of the expansion stro$e.
2. clearance for maintenance or repair; the distance between the item requiring
maintenance and the closest interfering surface.
clearance volume
space existing between the cylinder head and the top of the piston after completion of
compression stro$e.
clo
non2&I unit of clothing insulation, defined as the thermal insulation necessary to $eep a
sitting person comfortable in normally ventilated room at /,)6 21)C! and (,G relative
humidity. In physical terms, the thermal resistance of one
clo 5 ,.++)6O ft2Oh.Itu ,.1(( HOm2.K!.
closed process
series of changes of state in a system at the termination of which the system is reverted
to its original state.
coal
blac$ to brownish2blac$ combustible solid formed by the decomposition of ancient
vegetation in the absence of air, under the influence of biochemical action, moisture,
pressure, and heat.
anthracite coal
dense, hard coal with a very high percentage of fixed carbon, usually above *,G.
bituminous coal
soft coal containing from 1, to 2,G hydrocarbons yielding pitch or tar when distilled.
lignite coal
soft coal having a bed moisture of #, to '(G, nonca$ing and nonco$ing.
coaxial cable coax!
specially constructed single or multiconductor cable which provides shielding from
electrostatic fields.
coefficient
1. mathematics! number or letter, especially the former, put before a mathematical
expression to indicate that the expression is to be multiplied by that number; as in the
expression, 'ab, ' is the coefficient of ab; in 'abx, 'ab is the coefficient of x.
2. physics! number indicating the degree of a quality possessed by a substance, either
always or under fixed conditions; as, the coefficient of expansion of iron. contPd...!
=xamples: coefficient of expansion, a number that, when multiplied into the number
expressing the rise of temperature, gives the resulting expansion of a body;
coefficient of friction, a number that, when multiplied into the number expressing
the pressure between two bodies, gives the resulting friction; coefficient of
restitution, a fraction that, when multiplied into the relative velocity of two colliding
bodies "ust before impact, gives their relative velocity "ust afterward; differential
coefficient, ratio of the infinitesimal increase of a function to that of a variable on
which the function depends; a derivative.
cogeneration
sequential production of either electrical or mechanical power and useful thermal
energy heating or cooling! from a single energy form. &ee also electric power
generation cogeneration!.
coil
cooling or heating element made of pipe or tube that may or may not be finned, formed
into helical or serpentine shape.
blast coil
heat transfer surface, most frequently of an extended surface arrangement, over
which air is blown to be heated or cooled, depending on the temperature of the fluid
within the coil.
ceiling coil ceiling grid; overhead coil!
heating or cooling coil fitted in the ceiling of a room or space.
condenser coil
condenser constructed of pipe or tubing, not enclosed in a pressure vessel.
cooling coil
coil that uses refrigerant or secondary coolant to provide cooling, or cooling with
dehumidification.
desuperheating coil
heat exchanger, preceding the condenser or incorporated in it, for removing all or part
of the superheat.
direct expansion coil
coil used in direct refrigerating method.
domestic water coil
coil of tubing within a boiler to heat potable water for household use; usually a hot
water tan$ is used for hot water storage.
drier coil
additional length of pipe or coil added to direct expansion evaporator in order to
provide superheat at thermostatic expansion valve sensing bulb without using
evaporator tubing.
evaporator coil
evaporator constructed of pipe or tubing not enclosed in a pressure vessel.
expansion coil
evaporator constructed of pipe, plate, or tubing.
heating coil
coil that uses a heat transfer fluid, condensing refrigerant, or direct electrical
resistance elements to provide heating.
holdover coil
apparatus to store cold by fusion of ice or eutectic on a refrigerated coil.
pipe coil
cooling or heating element made of pipe or tubing more particularly made from one or
more bent pipes!.
preheat coil
heating coil installed upstream of cooling coil, or at the front of an air2handling system
to preheat air.
reheat coil
heating coil installed downstream of cooling coil.
wall coil wall grid!
cooling coil fitted in a wall of a room or a space.
coil dec$
insulated hori0ontal partition between refrigerated space and bun$er.
coil depth
number of rows of the tubes in the direction of airflow.
coil face area
product of the length and width of the coil face.
coil height
dimension of the vertical face of the coil as installed, including only the height over
tubes and fins exposed to the flow of air. 9ote: &ome steam coils have vertical tubes.
coil length
dimension of the face of the coil in the direction of the bare tubes or finned tubes, or
both, exposed to the flow of air.
coil width
dimension of the face of the coil exposed to the flow of air perpendicular to the direction
of the tubes.
co$e
solid substance remaining after the partial burning of coal in an oven distillation or in a
retort.
cold box
in a gas separation unit, the insulated section which contains the low2temperature heat
exchangers and distillation columns.
cold chain
continuity of means successively employed to provide the refrigerated preservation of
perishable foodstuffs from the production to the consumption stage.
cold in"ury low2temperature in"ury!
storage at a temperature below which physiological disorder in produce will manifest
itself. %his temperature will vary with the produce.
cold room cold chamber!
insulated structure served by a refrigerating system.
"ac$eted cold room
cold room which is entirely surrounded by insulated cavities or corridors in which cold
air is circulated.
sectional cold room
cold room constructed from factory prefabricated insulated sections which are
assembled on2site.
cold room door
cold room flexible door
two2way push2through type door made of thic$ plastic sheeting.
cold room flush2fitting infitting! door
door that does not protrude beyond the face of the wall.
cold room sliding door
single or multiple door that is movable laterally, usually in guides.
cold room swinging door
door pivoting on a vertical axis and which can be either pulled or pushed open.
cold room door di$e
pro"ection on the door which extends into the refrigerated compartments! and which
functions primarily as a barrier to minimi0e heat flow to the interior of the cabinet.
cold shrin$ fitting
process for assembling two precision2machined parts by cooling the inner member so
that it can be inserted into the outer member; the members fit tightly together when both
are at the same temperature.
cold trap
apparatus in which the walls are cooled in order to condense and trap vapors; can be
used to reduce pressure.
colloidal particle
parti$#es dispersed in a medi!m and ha)in' a state of s!"di)ision( at #east in one
dire$tion( in dimension ro!'h#y "etween 1 nm and 1 m%
color rendition
effect of a light source on the color appearance of an ob"ect, in a conscious or
unconscious comparison with the color appearance observed under a reference light
source, usually daylight.
combustion
chemical process of oxidation that occurs at a rate fast enough to produce heat and
usually light either as a glow or flame.
incomplete combustion
burning with an insufficient supply of air so the burning substance is only partially
consumed and could have been burned further with additional air supply. &ee
stoichiometric reaction.
perfect combustion
fuel burning condition in which all combustibles are consumed with no excess air so
that only the theoretical amount of oxygen is used.
combustion chamber
enclosure, with or without lines or baffles, into which fuel or gaseous derivatives of fuel
are discharged so that combustion can occur.
combustion control
device or series of devices that control the flow of fuel and combustion air in the desired
ratio to provide efficient combustion.
full2modulation combustion control
ad"ustment of the fuel rate and air2fuel mixture ratio, in response to heating load and
the temperature and excess air condition of the flue gas, over the full range of the
burner capacity from some preset minimum to 1,,G.
combustion detector
part of primary safety control which is responsive directly to flame properties.
combustion products
effluents from the combustion of a fuel including the inerts, but excluding excess air.
combustion gas! tests
sampling of combustion products to determine the percentage of constituents and their
temperature.
combustion volume
space provided for the burning of fuel.
commissioning of an installation!
process for achieving, verifying, and documenting the performance of buildings to meet
the operational needs of the building within the capabilities of the design and to meet
the design documentation and the ownerPs functional criteria, including preparation of
operator personnel.
commissioning authority
qualified person, company, or agency that plans and carries out the overall
commissioning process.
commissioning plan
overall document, usually prepared by the commissioning authority, which outlines the
organi0ation, scheduling, allocation of resources, documentation, etc., pertaining to the
overall commissioning process.
communications2based system
energy management system in which a computer is the central controlling device.
compliance
act of complying with the rules or requirements of a standard.
certified compliance
demonstrated compliance as "udged by an agency or authority not within 4&<14=.
compound compression
compression which is accomplished by stages as in two or more cylinders in series.
compressibility
1. relative variation of the departure from the perfect gas laws.
2. ease with which a fluid may be reduced in volume by the application of pressure. It
depends on the state of the fluid as well as the type of the fluid itself.
compression
process by which the pressure of a gas is increased by reducing its volume.
adiabatic compression
compression of a gas during which no heat is exchanged with the surroundings.
dry compression
compression of initially dry saturated or superheated vapor.
dual compression
compression of refrigerant entering a single cylinder from two sources at different
suction pressures.
multistage compression
compression in two or more stages; usually the low stage compressor discharges to
the suction of a higher stage compressor.
polytropic compression
compression of a fluid involving heat exchange with temperature change and
temperature variation not isothermal!.
single2stage compression
compression from evaporator to condenser pressure by passing through one
compressor stage only.
wet compression
compression of vapor that initially is not saturated or superheated.
compression stage
each part at compression whereby the total compression of a gas is accomplished by
several compressors in series to reduce the compression ratio for each stage.
compression stro$e
that movement of a piston in a compressor cylinder during which the gas is compressed
and discharged.
compressor
1. device for mechanically increasing the pressure of a gas.
2. specific machine, with or without accessories, for compressing refrigerant vapor
4&A= &tandard I#1.(!.
axial2flow compressor
turbocompressor in which the com2pressed fluid flows generally in a direction parallel
to the axis of rotation.
booster compressor
compressor for raising the pressure of a gas delivered to a following compressor.
centrifugal compressor
nonpositive displacement compressor which depends for pressure rise, at least in
part, on centrifugal forces. 4 turbocompressor.
closed cran$case compressor
one in which the cran$case is completely sealed from the atmosphere, but connected
with the low2pressure side of the system.
compound compressor
compressor in which compression is accomplished by stages, as in two or more
cylinders.
diaphragm compressor
type of oil2free compressor in which flexion of a diaphragm creates compression.
double2acting compressor
compressor which has two compression stro$es per revolution of cran$shaft per
cylinder, i.e., both faces of the piston are wor$ing faces.
double2suction compressor
split suction valving arrangement on compressor for carrying two suction pressures.
dry2piston compressor
type of oil2free compressor in which no lubricating oil is used in the cylinder; the piston
is usually equipped with low friction labyrinth rings.
dual2effect compressor
compressor in which the cylinders have an additional suction inlet partway along the
compression stro$e which enables refrigerant to be drawn in at two different suction
pressures.
flexible2shaft centrifugal compressor
impeller and shaft are a one2piece assembly, the latter of a small diameter so that it
can flex and spontaneously balance the inertial forces resulting from rotation.
multistage compressor
compressor in which compression is accomplished in more than two stages in
separate cylinders.
multivane rotary compressor
sliding vane compressor with several vanes, sliding in slots in the rotor, and
maintaining continuous contact with the inner periphery of the fixed casing.
nonpositive displacement compressor
rotary compressor in which the compression is obtained without reduction of internal
volume of the compression chamber.
oil2free compressor
compressor in which no oil is used in the compression chamber. &ee dry2piston
compressor.
open2type compressor
refrigerant compressor with a shaft or other moving part extending through its casing
to be driven by an outside source of power, thus requiring a shaft seal or equivalent
rubbing contact between fixed and moving parts.
positive displacement compressor
machine that increases the pressure of refrigerant vapor by reducing the volume of
the compression chamber through wor$ applied to the mechanism.
reciprocating compressor
positive2displacement compressor in which the change in internal volume of the
compression chambers! is accomplished by the reciprocating motion of one or more
pistons.
return flow compressor
compressor in which the suction valve is located in the cylinder head of the
compressor.
rolling piston compressor
special type of small rotary compressor having a rotor aligned eccentrically within the
stator, used in domestic refrigerators.
rotary compressor
positive displacement compressor in which the change in internal volume of the
compression chambers! is accomplished by the rotary motion of a positive
displacement members!.
screw compressor
rotary compressor relying on the intermeshing of two helical rotors to produce
compression.
scroll compressor
positive2displacement compressor in which the reduction in internal volume of the
compression chamber is accomplished by an orbiting scroll involute spiral! within a
mating stationary scroll.
sealed unit compressor hermetic compressor!
motor2compressor assembly having the compressor contained within a gas2tight
casing through which no shaft extends. 7rive is usually by a motor within the same
casing but may be induced by external means.
semihermetic compressor
compressor directly coupled to an electric motor and contained within a gas2tight
bolted casing.
single2acting compressor
compressor having one compression stro$e per revolution of the cran$ for each
cylinder.
single2vane rotary compressor
sliding vane compressor with one vane, sliding in a slot in the fixed casing,
maintaining continuous contact with the rotor, and separating the suction and the
delivery ports.
sliding vane compressor
rotary compressor having a rotor aligned eccentrically within a cylindrical housing,
with one or several vanes located in slots in the rotor or in the housing.
stepped piston compound compressor differential piston compressor!
single2acting compressor for compound operation, the lower stage of which is
compressed in a chamber in which the larger diameter of the stepped piston moves
and the higher stage is compressed in a chamber in which the smaller diameter of the
piston moves.
stiff shaft centrifugal compressor
impeller and the shaft are a one2piece assembly with the shaft of large diameter so
that it cannot flex.
subsonic compressor
turbocompressor in which the speed of fluid flow is subsonic in all parts of the
compressor.
supersonic compressor
turbocompressor in which the fluid flow, in certain parts of the machine, attains
supersonic velocity.
swash plate compressor wobble plate compressor!
compressor in which the pistons move parallel to the cran$shaft, actuated by a cam or
by a plate mounted axially on the shaft and inclined to it.
tandem compressor dual compressor!
1. two compressors driven by the same motor mounted on the same base or frame.
2. assembly of two semihermetic compressor units having a common suction
chamber.
turbocompressor
turbine2driven compressor, usually a centrifugal compressor.
twin2cylinder compressor
reciprocating compressor with two identical operating cylinders.
uniflow compressor
compressor in which the suction gas passes through the piston.
vertical compressor
compressor with a vertical cylinder or, in small si0es, with a vertical cran$shaft.
compressor capacity refrigerating!
design maximum rate of heat removal by the refrigerant assigned to the compressor in
a refrigerating system. %his is equal to the product of the mass rate of refrigerant flow
produced by the compressor and the difference in specific enthalpies of the refrigerant
vapor at its thermodynamic state entering the compressor and the refrigerant liquid at
saturation temperature corresponding to the pressure of the vapor leaving the
compressor.
compressor capacity reducer
device, such as a clearance poc$et, movable cylinder head, or suction bypass, by which
compressor capacity can be ad"usted without otherwise changing the operating
conditions.
compressor clearance poc$et
space of controlled volume to give the effect of greater or less cylinder clearance,
thereby changing compressor capacity.
compressor discharge
that part of the compressor at the high2pressure side.
compressor discharge stro$e
that part of the piston stro$e between the opening of the discharge valve and the top
dead center.
compressor displacement
actual volume of gas or vapor at compressor inlet conditions moved by a compressor,
per revolution or per unit of time. Compare piston displacement.
compressor economi0ing
process whereby a side port in the compressor usually a screw compressor or
multiwheel centrifugal compressor! is used to provide refrigerant sub2cooling, resulting
in an improvement in overall system efficiency.
compressor motor, sealed hermetic type!
compressor and motor enclosed in the same housing without external shaft or shaft
seals, with the motor operating in the refrigerant.
compressor oil return
transport of oil from the evaporator to the compressor.
compressor piston displacement
volume swept by a piston during one stro$e, or one revolution of the cran$shaft.
compressor refrigerating effect
rate of heat removal by the refrigerant assigned to the compressor in a refrigerating
system. %his is equal to the product of the mass rate of refrigerant flow produced by the
compressor and the difference in specific enthalpies of the refrigerant vapor at its
thermodynamic state entering the compressor and refrigerant liquid at saturation
temperature corresponding to the pressure of the vapor leaving the compressor.
compressor starting
no2load start unloaded start!
practice of starting a compressor after equali0ing pressures in high2 and low2side
pressures.
compressor unloader
1. device on or in a compressor for equali0ing the high2 and low2side pressures for a
brief period during starting in order to decrease the starting load on the motor.
2. device for controlling compressor capacity by rendering one or more cylinders
ineffective.
compressor surge
condition achieved in a centrifugal compressor when the momentum of the refrigerant
gas through the compressor is insufficient to overcome the thermal lift requirement.
7irection of flow temporarily reverses through the compressor until the lift requirement
decreases. %he condition repeats until the operating condition is corrected. 4ccelerated
wear and damage can eventually result.
compressor theoretical displacement
total volume swept by the wor$ing stro$es of all the pistons of a compressor per
revolution of the cran$shaft or per unit of time.
compressor unit
a refrigerating component designed to compress a specific refrigerant vapor, consisting
of compressor, prime mover, and regularly furnished accessories.
compressor wor$
mechanical energy required by, or load imparted to, the piston of a compressor or shaft
of a centrifugal compressor.
compressor wor$ theoretical!
enthalpy difference along an isentrope.
effective compressor wor$
net wor$ input absorbed at the shaft of a compressor, irrespective of time.
indicated compressor wor$
wor$ equivalent of indicator card area for a reciprocating compressor or engine. &ee
also indicator diagram.
computer
1. machine for carrying out calculations.
2. by extension, a machine for carrying out specified transformations on information.
#. stored program data2processing system. continued on next page!
'. device capable of solving problems by accepting data, and supplying the results of
these operations. Earious types of computers are calculators, digital computers, and
analog computers.
(. in information processing, usually, an automatic stored program computer.
computer based system
energy management system in which a computer is the central controlling device.
computer code
set of symbols or abbreviations used to represent data.
symbolic computer code
code which expresses computer programs in source language, i.e., by referring to
storage locations and machine operations by symbolic names and addresses which
are independent of their hardware2determined names and addresses.
computer hardware
physical entities such as computers, circuit boards, C1%s cathode2ray tubes!, and
printers.
computer input
1. data to be processed.
2. state or sequence of states occurring on a specified input channel.
#. device or collective set of devices used for bringing data into another device.
'. channel for impressing a state on a device or logic element.
(. process of transferring data from an external storage to an internal storage.
analog input
1. a verifying quantity; e.g., pressure, voltage, or temperature, which can have any
value between a minimum and a maximum, used as the initiating part of a control
system.
2. input of a physical variable in a continuous form such as a voltage input to a
voltmeter.
computer memory
general term for the computer equipment that holds information in any usually binary
language in electrical, optical, or magnetic form. %his equipment also receives
information for storage and gives out the stored information for storage and later use.
%he word BmemoryD usually means storage inside the computer, while BstorageD refers
to optical and electrical media storage outside of the computer.
electrically erasable programmable read2only memory ==>1FA!
erasable in2soc$et requires no batteries!.
erasable programmable read2only memory =>1FA!
field erasable via exposure to ultraviolet light, and reprogrammable requires no
batteries!.
programmable read2only memory >1FA!
not field2modifiable, nonvolatile requires no batteries!.
random2access memory 14A!
memory providing access time that is independent of the address, and is addressable
for both reading from and writing into memory.
read2only memory 1FA!
memory with stored data that can be read but not changed or written into.
computer overflow
1. condition that arises when the result of arithmetic operation exceeds the capacity of
the storage space allotted in a digital computer.
2. digit arising from this condition if a mechanical or programmed indicator is included,
otherwise the digit may be lost.
computer printer
device capable of producing printed copy.
computer printout
hard copy output of a printer.
computer reset
1. verb. to return a memory or storage element to its BstandardD state, usually B,D. 4lso
called clear.
2. verb. to restore a storage device to a prescribed state, not necessarily that denoting
0ero.
#. computer2control state in which integrators are held inoperative and the proper initial
condition voltages or charges are applied or reapplied.
'. verb. to place a binary cell into the B0ero state.D
computer run
performance of one program to its end on a computer thus the performance of one
routine, or several routines lin$ed so that they form an automatic operating unit during
which manual manipulations by the computer operator may be 0ero or minimal.
computer significant digit
digit that contributes to the precision of an accurate numeral. %he number of digits is
counted beginning with the digit contributing the most value, called the Bmost significant
digit,D and ending with the one contributing the least value, called the Bleast significant
digit.D
computer simulation
1. computer2aided decision process in which proposals are tested in a computer before
one or more of the proposals are considered for use.
2. general! representation of an actual system by analogous characteristics of some
device easier to construct, modify, or understand.
#. physical! the use of a model of a physical system in which computing elements are
used to represent some but not all of the subsystems.
computer software
1. programs and instructions put into a computer.
2. totality of programs and routines used to extend the capabilities of computers, such
as compilers, assemblers, narrators, routines, and subroutines.
computer software library
1. general collection of software pac$ages available for a particular data2processing
system.
2. computer programs and called into a routine to perform a special assignment.
computer sort
verb. to arrange items of information according to rules dependent on a $ey or field
contained in the items or records; e.g., to digital sort is to sort first the $eys on the least
significant digit, and to resort on each higher order digit until the items are sorted on the
most significant digit.
computer space
1. site intended for the storage of data, e.g., a site on a printed page or a location in a
storage medium.
2. basic unit of area, usually the si0e of a single character.
#. one or more blan$ characters.
'. verb. to advance the reading or display position according to a prescribed format,
e.g., to advance the printing or display position hori0ontally to the right or vertically
down.
(. open2circuit condition in a (2level or +2level 4&CII! signal code. 4lso the shift down in
a frequency shift $ey 6&H! telemeter system.
computer storage
1. device into which data can be entered and from which it can be retrieved later.
2. loosely, any device that can store data.
computer storage buffer
1. element between two different forms of storage, usually between internal and
external.
2. input device in which information is assembled from external or secondary storage
and stored ready for transfer to internal storage.
#. output device into which information is copied from internal storage and held for
transfer to secondary or external storage. Computation continues while transfers
between buffer storage and secondary or internal storage or vice versa, ta$e place.
'. device that stores information temporarily during data transfers. Clarified by buffer.
computer subroutine
1. in a routine, the set instructions that cause a computer to carry out a well2defined
mathematical or logical operation.
2. routine which is part of a larger routine and whose action is dependent on findings or
manipulations prior to reaching the subroutine.
#. subunit of a routine. 4 subroutine is often written in relative or symbolic coding even
when the routine to which it belongs is not.
'. routine which is arranged so that control may be transferred to it from a master
routine and so that, at the conclusion of the subroutine, control reverts to the master
routine. &uch a subroutine is usually called a Bclosed subroutine.D
(. a single routine may simultaneously be both a subroutine with respect to another
routine and a master routine with respect to a third. 8sually control is transferred to a
single subroutine for more than one place in the master routine; the reason for using
the subroutine is to avoid having to repeat the same sequence of instructions in
different places in the master routine.
computer switch
point in a programming routine at which two courses of action are possible, the correct
one determined by a condition prevailing elsewhere in the routine or by a physical
disposition of the system.
computer time division multiplex
1. device which samples all data input from different low2speed devices and retransmits
all the samples in an equal amount of time.
2. process or device in which each modulating wave modulates a separate pulse
subcarrier, the pulse subcarriers being spaced in time so that no two pulses occupy
the same time interval. 9ote: %ime division permits the transmission of two or more
signals over a common path by using different time intervals for the transmission of
the intelligence of each message signal.
computer time sharing
use of a device for two or more purposes during the same overall time interval;
accomplished by interspersing component actions in time.
condensate
liquid formed by condensation of a vapor. In steam heating, water condensed from
steam; in air conditioning, water extracted from air, as by condensation on the cooling
coil.
condensation
change of state of a vapor into a liquid by extracting heat from the vapor.
droplet condensation
phenomenon encountered when the condensate does not wet the cold surface, but
settles in the form of separate droplets.
film2forming condensation
phenomenon encountered when the condensate wets a cold surface to form a
continuous film that separates this surface from the vapor.
solid phase condensation
direct formation of the solid phase by cooling a vapor below the triple point.
condenser
heat exchanger in which vapor is liquefied by the re"ection of heat to a heat sin$. &ee
also condensing unit.
air2cooled refrigerant condenser
refrigerant condenser in which heat removal is accomplished entirely by heat
absorption by the air flowing over condensing surfaces.
air2cooled unit
condensing unit which utili0es refrigerant2to2air heat transfer means.
atmospheric condenser
condenser in which the pipes in open air are cooled by water flowing over them.
barometric condenser
apparatus in which steam is condensed at reduced pressure by direct contact with
water.
coaxial condenser
water2cooled condenser in which water and refrigerant flow in parallel paths but in
opposite directions.
double bundle condenser
condenser that contains two separate tube bundles allowing the option of either
re"ecting the heat to the cooling tower or to another building system requiring heat
input.
double pipe condenser tube2in2tube condenser!
condenser constructed of concentric tubes in which the refrigerant circulates through
the annular space and the cooling medium through the inner tube.
evaporative condenser
condenser in which the removal of heat from the refrigerant is achieved by the
evaporation of water from the exterior of the condensing surface, induced by the
forced circulation of air and sensible cooling by the air.
multishell condenser
condenser consisting of a number of closed shell2and2tube units.
natural convection condenser
condenser cooled by natural circulation of atmospheric air.
open shell2and2tube condenser
condenser in which the water passes in a film over the inner surfaces of the tubes,
which are open to the atmosphere.
plate2type condenser
1. air2cooled condenser consisting of plates between which are arranged channels for
the circulation of refrigerant.
2. water2cooled condenser consisting of a coil through which the refrigerant circulates,
arranged between two plates, water circulating between coil and plates.
receiver condenser
water2cooled condenser comprising a shell with the bottom located below the heatexchanging
elements to form a receiver; in principle designed to hold the entire
refrigerant charge of the installation.
secondary condenser
condenser cooled by the evaporator of a secondary system.
shell2and2coil condenser
condenser in which the cooling medium circulates in a coil located in a shell
containing the condensing refrigerant.
shell2and2tube condenser
condenser consisting of an outer shell containing multiple tubes.
split condenser
condenser comprising several heat exchanging components operating on one or
several refrigeration systems.
submerged coil condenser submerged condenser!
condenser in which the piping is submerged in a vessel containing cooling water.
tube2in2tube condenser
condenser consisting of a tube inserted in a second tube in a helical coil, serpentine
coil, or parallel tubes.
water2cooled condenser
condenser in which heat of the refrigerant is removed by water flowing over
condensing surfaces.
water2cooled units
condensing units which transfer heat from the refrigerant to water.
condenser heat2re"ection effect condenser duty!
amount of heat energy re"ected to its surroundings by a condenser.
condensing unit
machine specifically designed to condense refrigerant vapor to a liquid by compressing
the vapor in a positive2displacement compressor and re"ecting heat to a cooling
medium. %he unit consists usually of one or more positive2displacement compressors,
motors, condensers, liquid receivers when required!, and necessary accessories,
mounted on a common base.
hermetically sealed condensing unit
sealed compressor unit in which the housing is permanently sealed by welding or
bra0ing and is not provided with means of access for servicing internal parts in the
field.
sealed condensing unit
mechanical compressor unit in which the compressor and compressor motor are
enclosed in the same housing with no external shaft or shaft seal, and the compressor
motor operating in the refrigerant atmosphere.
service2sealed condensing unit
sealed compressor unit in which the housing is sealed by one or more gas$ets, and
means of access are provided for servicing internal parts in the field.
condensing unit capacity
condensing unit refrigerating effect
rate of heat removal by the refrigerant assigned to the condensing unit in a
refrigerating system. %his is equal to the product of the mass rate of refrigerant flow
produced by the condensing unit and the difference in the specific enthalpies of the
refrigerant vapor entering the unit at a specified superheat, and the refrigerant liquid
leaving the unit at a specified subcooling.
conditioned floor area
hori0ontal pro"ection of interior space within exterior walls that is conditioned directly or
indirectly.
conditioned space
space within a building provided with heated or cooled air, or both or surfaces!; and,
where required, with humidification or dehumidification means, to maintain conditions
for an acceptable thermal environment.
condition line
on a psychrometric chart the infinite number of wet2 and dry2bulb temperatures which
will satisfy the requirements of an air supply for a given room temperature.
conductor
1. substance or body capable of transmitting electricity, heat, etc.
2. substance or body that allows a current of electricity to pass continuously along it.
#. wire or combination of wires not insulated from one another, suitable for carrying an
electric current.
'. portion of a lightning2protection system designed to carry the lightning discharge
between air terminal and ground.
conduit
1. tube or pipe used for conveying fluid.
2. tube or pipe in which wires may be enclosed for protection.
connecting rod
part of a compressor that connects the piston to a cran$ used to interchange rotating
motion and reciprocating motion.
connection2in2parallel
system in which flow is divided among two or more channels from a common starting
point or header.
connection2in2series
system in which flow through two or more channels is in a single path entering each
succeeding channel only after leaving the first or previous channel.
consensus
substantial agreement reached by concerned interests according to the "udgment of a
duly appointed authority after a concerted attempt at resolving ob"ections. It implies
much more than a simple ma"ority, but not necessarily unanimity.
consensus process
procedures adopted by a standards2developing organi0ation to reach consensus.
consensus standard
in 4&<14=, a standard developed by the consensus process reflecting a consensus of
professional opinions of the members of a committee of balanced interests, with the
support of other experts who review and comment on drafts during open public review.
conservation of energy law
see thermodynamics laws.
constant
mathematical value that does not change during a particular process.
contact
conducting part that coacts with another conducting part to complete or to interrupt a
circuit.
contact2closure input
1. signal sent to the coil of a relay causing it to change the position of its contacts.
2. input in which the input device is a normally open contact which closes on operation.
contactor
electromagnetic switching device.
contaminants refrigerating system!
most important and universal contaminant is moisture. Fther contaminants include dirt,
waxes, metal particles, and organic materials such as acids, sludges, or other products
of chemical reactions ta$ing place while the system is operating. &ee also air
contaminant; refrigerating system contaminants; water contaminant.
contractor
in construction terminology, the person or entity responsible for performing the wor$ and
identified as such in an owner2contractor agreement.
licensed contractor
person or entity certified by governmental authority, where required by law, to engage
in construction contracting.
prime contractor
contractor on a pro"ect having a contract directly with the owner.
subcontractor
person or entity who has a direct contract with the contractor to perform any of the
wor$ at the site.
control.controller.control system
1. device for regulation of a system or component in normal operation, manual or
automatic. If automatic, the implication is that it is responsive to changes of pressure,
temperature, or other variable whose magnitude is to be regulated.
2. industrial! broadly, the methods and means of governing the performance of any
apparatus, machine, or system; system governing the starting, stopping, direction of
motion, acceleration, speed, and retardation of the moving member; designation of
how the equipment is governed; i.e., by an attendant, by automatic means, or
partially by automatic means and partially by an attendant; frequently, one or more of
the components in a mechanism responsible for interpreting and carrying out
manually initiated directions.
#. verb. to execute the function of control as defined above.
'. in a digital computer, those parts that affect the retrieval of instructions, and the
application of the proper signals to the arithmetic unit and other parts in accordance
with this interpretation. Compare controller. &ee also thermostat.
ambient2compensated control
one designed to negate the effects of ambient conditions surrounding the body of the
control, thereby not affecting the control output.
anticipating control
one which, by artificial means, is actuated sooner than it would be without such means
to produce a smaller differential of the controlled variable.
application2specific control
digital controller dedicated to a specific application such as a E4E box or water2source
heat pump.
automatic sequence control
one in which successive operations are carried out in a sequence either
predetermined or resulting from the correct execution of each successive operation.
capacity control capacity regulator!
1. variation of the quantity of refrigerant circulated by the compressor in order to vary
the refrigerating capacity.
2. in a refrigerating compressor, a device by which capacity can be ad"usted without
otherwise changing the operating conditions.
cascade control
complex control system in which the set value of one or more controllers is altered by
one or more controlling equipment devices.
central control
1. location from which more than one control action can be manipulated.
Computeri0ed data processors are not a prerequisite.
2. ability to control all functions from one central location, thereby enabling the
operator to request and respond to all commands from one location.
changeover control
control used to change a system over from one mode of operation to another, using
automatic or manual devices.
closed loop control feedbac$ control!
1. control system in which the effect of the control action on the controlled variable is
sensed and used by the controller to provide a new output feedbac$ control!.
Compare open2loop control.
2. signal path which includes a forward path, a feedbac$ path, and a summing point,
and forms a closed circuit.
combination control
control device in which one or more control variables are being monitored, such as a
combination high2 and low2pressure control for a refrigerant system.
cycling control
control which functions by automatic cycling between desired limits as differentiated
from a limit control and a continuous control.
defrost control
act of controlling the refrigerating cycle or heating cycle to periodically melt the
unacceptable accumulation of ice on evaporator tubes, windows, etc.
derivative control
control action in which the output is based on the rate of change of the input.
differential controller
1. device used to maintain a given difference in pressure or temperature between two
pipelines or spaces.
2. controller reactive to the difference between values of two variables.
differential pressure control
1. method of maintaining a given pressure difference in two pipelines or spaces.
2. device that maintains a set difference in pressure between two reference points.
direct digital control 77C!
mode of control wherein digital outputs are used to control a process or element
directly.
dual2effect control
device responsive to temperatures of two 0ones or to two variable conditions.
dual2pressure control
1. two pressure controls in one enclosure.
2. use of a single device to accomplish some form of pressure control at two distinct
set points, such as a dual2pressure switch.
#. combined pressure regulating device, one part connected to the low2pressure side
of the system and one part to the high2pressure side of the system, with a common
switch mechanism.
fixed2setting control
control in which the set point cannot be altered.
flame safeguard control
system for sensing the presence or absence of flame and for indicating, alarming, or
initiating control action.
floating control
mode of control in which the final control element moves at a predetermined rate in a
corrective direction until the controller is satisfied or until a movement in the other
direction is called for.
flow control
modulation of a fluid flow rate through a system of piping, ductwor$, or variable
devices.
free0e2up control
1. control device to prevent failure of a refrigerating system due to formation of ice at
the expansion device or from frost formation on a coil. continued on next page!
2. thermostatic device that senses the approach of a free0ing condition and ta$es
corrective action.
head pressure control
pressure2operated control which opens an electrical circuit if the high side pressure on
a refrigerating machine becomes excessive. 4lso called high2pressure cutout. &ee
high2pressure control, under control.controller.control system.
high event control
control action that occurs at the higher value of the activating variable being sensed.
high2low control
two2level action in which both levels are controlled within defined limits.
high2pressure control
pressure2responsive device which cycles and.or stages condensers, cooling tower
fans, and pumps to control head pressure.
humidity control humidistat, hygrostat!
device which responds directly or indirectly to deviation from a desired humidity by
actuating a control or initiating a control sequence.
ice2ban$ control
control of the thic$ness of a ban$ of ice for off2pea$ cool storage; also for use with mil$
coolers and other refrigerating cabinets in which refrigerating capacity is stored by
means of ice.
limit control
control device used to limit the desired maximum or minimum state of the controlled
variable, or to provide an alarm if those limits are exceeded.
low2pressure control
1. pressure2responsive device actuated directly by refrigerant vapor pressure in the low
side.
2. electric switch and pressure2responsive element connected into the suction side of a
refrigerating system to control the operation of the system.
master controller
1. instrument whose variable output is used to change the set point of a submaster
controller.
2. central device that develops corrective action, in response to the area control error,
for execution at one or more generating units.
#. controller that contains the necessary circuits to operate slave controllers.
modulating control
method of control in which the output of the controller may vary infinitely over its
range. Compare two2position control.
numerical control
control in which digital computers are used for the control of operations, particularly of
automatic machines; e.g., drilling or boring machines, wherein the operation control is
applied at discrete points in the operation or process.
oil pressure cut2out differential oil pressure switch; oil failure switch!
safety device used to stop the compressor when the oil pressure reaches a preset,
abnormally low value.
oil temperature cutout
safety device used to stop the compressor when the oil temperature reaches a preset,
abnormally high value.
open2loop control
control system in which the effect of the control action is not felt by the sensed
variable; e.g., outside air when it is used for reset. Compare closed loop control.
pneumatic electric control
1. control device which interfaces pneumatic to electric systems.
2. control device with a pneumatic input and an electric output.
pressure control
device which responds directly or indirectly to deviation from a desired pressure by
actuating a control or initiating a control sequence.
process control
1. control for automatic regulation of operations or processes, or both.
2. closed loop control as applied to processes or operations, or both. 9ote: <E4C
systems may be considered as processes.
programming control
control system that provides for performing various operations in predetermined
sequences related to time or other variables.
remote control
control of a device or system from a location other than at site of operation, using
direct wire, carrier current, microwaves, supervisory control, or mechanical means.
reset control integral control; automatic reset!
control method using a remote or external signal to modify the set point of a controller.
safety safety cut2out! control
control that causes equipment to cease operation when adverse or excessive
conditions occur.
self2powered control self2operated control; system2powered control!
method of control which requires no external or auxiliary power supply.
sequence control
1. group of devices which act in series or in a time order.
2. operation of two or more final control elements in separate stages as opposed to
unison.
servo control
mechanism which automatically actuates a system according to the variation of input.
%he device is designed so that a small input power controls a much larger output
power.
snap action control
1. control that ma$es or brea$s a circuit in a positive two2position manner.
2. mechanism operation requiring low operating forces, high repeat accuracy, and fast
operating time.
step controller
multiple2switch assembly in which a moving element trips multiple output steps
successively.
submaster controller
1. controller whose set point is automatically read"usted from a remote location over a
predetermined range by variations in an applied signal from a master.
2. controller whose set point may be automatically reset at the command of either a
conventional or master controller.
temperature controller
device which responds directly or indirectly to deviation from a desired temperature by
actuating a control or initiating a control sequence.
two2position control
control that is either F9 or F66 or F>=9.CCF&=7 or some similar pair of states!.
Compare valve modulating control!.
control action of a controller or a controlling system!
nature of the change of the output produced by the input.
creep action
slow ma$e.brea$ action of a switch mechanism in a controller, as differentiated from
snap action or toggle action.
snap action
response of a switch to very small movements of its actuating button or lever,
changing rapidly and positively from one contact position to the other. &ee also control
snap action control!.
toggle action
action of a switch to change to an alternate contact position as in a flip2flop.
control channel
communication lin$ that carries electrical signals directing performance of a digital
system but does not carry main power.
control detecting element
in a control measuring unit, the element which responds directly to, or senses, the
variable to be measured.
control device
individual device used to execute a control function.
control element final!
mechanism that directly acts to change the value of the controlled variable.
controlled atmosphere storage gas storage; C4 storage!
in food storage rooms, the addition of carbon dioxide to the atmosphere, particularly in
large concentrations, with no attempt to regulate the amount of oxygen.
controlled device
one that receives a signal from a controller and acts on the process plant to vary its
operating condition in accordance with the information received. In <E4CQ1 systems,
controlled devices typically are valves, dampers, and motors.
controlled medium
substance that is to be maintained at a specific value of temperature, concentration, or
flow rate.
controller
device that accepts the sensed value of a variable, compares it with a set point to
determine an error signal, and provides an output which is a result of that comparison.
continued on next page!
%he output is sent to a controlled device but may also be used for rest or other
purposes.
controller error signal
difference between the control point actual value of the controlled variable! and the set
point. %his quantity may have a plus or minus sign.
controller gain gain of a controller!
ratio of change in controller output to the change in the value of the sensed value.
controller proportional band
range of controller output as it goes from one extreme to the other.
control concentration level in a laboratory fume hood!
average concentration of gas, parts of tracer gas per million parts of air by volume
ppm!, that is not exceeded at the hood face at given release rate.
control measuring element
element used to measure the status of a controlled variable.
control modes
derivative control mode
one that contributes to the output of the controller an amount equal to the derivative of
the error signal, multiplied by the derivative gain.
integral control mode
one that contributes to the output of the controller an amount equal to the integral of
the error signal over time, multiplied by the integral gain.
proportional control mode
one that requires offset from the desired set point to move the controlled device
through its proportional band.
control panel
assembly of the indicating devices and remote control units required for the operation of
a system.
unit control panel 8C>!
location where one or more accessory panels are grouped to serve a single remote
system. Contains both accessory devices and local loop controls.
control point
1. value of a directly controlled variable at which the instrument is controlling. &et point
plus offset is equal to control point.
2. mean value of a controlled temperature maintained by a thermostat under specific
operating conditions.
control power element
actuator in an automatic control.
convector
surface designed to transfer its heat to a surrounding fluid largely or wholly by
convection.
conversion
1. process of changing information from one form of representation to another, such as,
from the language of one type of machine to that of another or from magnetic tape or
dis$ to the printed page. continued on next page!
2. process of changing from one data2processing method to another, or from one type
of equipment to another.
#. verb. to change from use of one fuel to another.
coolant
fluid used to transfer heat from one place to another. Compare refrigerant.
brine
secondary coolant consisting of a solution of a salt in water.
primary coolant
refrigerant used to lower the temperature of a secondary coolant.
secondary coolant secondary fluid!
liquid used for the transmission of heat without a change of state, having no flash
point, or a flash point above 1(,)6 -(.-)C!.
cooler
thermally insulated enclosure $ept at a reduced temperature by a refrigeration. &ee also
air cooler; cooling system.
Iaudelot cooler falling film surface cooler!
liquid cooler in which the liquid to be cooled passes by gravity over a refrigerated
surface.
brine cooler
heat exchanger for cooling brine or other secondary coolant.
chill2room cooler
room refrigerated to chill the product without free0ing it.
cold2storage cooler
ins!#ated room maintained !s!a##y at "e#ow ',)6 ()C! but not below #,)6 *R1)C!%
cooler2stabili0ed operation
operating condition at which all test values would be repetitive or cyclic! if the
machine were operated for an extended period.
drin$ing water cooler
unit in which drin$ing water is cooled by refrigeration and usually dispensed by a
manual valve.
drum cooler
rotating refrigerated cylinder whose surface is in contact with the liquid to be cooled.
enclosed liquid cooler
1. within a pressure2tight vessel, a heat exchanger consisting of an assembly of tubes
containing the liquid to be cooled.
2. apparat!s for $oo#in' f#!id o!t of $onta$t with the atmosphere%
evaporative cooler
one that cools indoor air by moisture evaporation, thereby lowering its dry2bulb
temperature and raising its wet2bulb temperature, all at a constant energy level.
&ee also cooling evaporative!.
ice2ban$ cooler
water cooler in which ice is allowed to collect on the evaporator tubes.
mil$ cooler
apparatus capable of cooling mil$ to the required temperature prior to collecting,
processing, or delivery.
nonpriming cooler
one in which tubes are omitted from the top segment of the shell, leaving a gas space
above the tubes approximately equal to one2fourth of the inside shell diameter.
oil cooler
heat exchanger which can be cooled by air, water, or refrigerant vapori0ation, to cool
oil in a lubrication system.
panel cooler
refrigerated flat surface, mainly by radiation.
plate liquid cooler
heat exchanger made of thin plates so formed that liquid to be cooled flows through
the passage between the plates and the cooling fluid flows through the alternate
passages.
precooler
1. cooler for removing sensible heat before shipping, storing, or processing.
2. device for cooling a fluid before it enters a system.
scuttlebutt cooler
evaporator cooler used for cooling drin$ing water at a central plant.
sensible2heat cooler
cooling surface located on the leaving side of a dehydrator, frequently treating room
air which is not circulated through the dehydrator.
swamp cooler
slang for evaporative cooler.
tunnel cooler
chilled, elongated space for cooling foodstuffs on a movable transport system by rapid
circulation of cold air.
unit cooler
direct2cooling, factory2made encased assembly including an air2cooling coil,
refrigerating compressor and condenser, fan and motor usually! and directional
outlet, including the necessary automatic controls. &ee air cooler.
wal$2in cooler
cooling chamber large enough to wal$ in.
cooling
process for reducing the temperature of a space or system below a specified level.
Compare refrigeration.
air2blast cooling
cooling by forced circulation of air at high velocity. Compare "et cooling.
comfort cooling
refrigeration for comfort as opposed to refrigeration for storage or manufacture.
contact cooling
cooling by direct contact with a cold surface.
district cooling
concept of providing and distributing, from a central plant, cooling to a surrounding
area district! of tenants or clients residences, commercial businesses, or institutional
sites!. Compare district heating.
evaporative cooling
sensible cooling obtained by latent heat exchange from water sprays or "ets of water.
&ee cooling system.
flood2type hydrocooling
obsolete term. 8se immersion hydrocooling.
forced2draft cooling
1. cooling air or gas by forced circulation over the cooling surface.
2. cooling a space by means of air cooled by forced convection.
#. cooling condenser water by moving air across its spray.
hydrocooling
cooling of produce generally vegetables or fruit! by direct contact with chilled water.
immersion hydrocooling
process of cooling fruits and vegetables by submerging them in a chilled water bath.
"ac$et cooling
cooling process in which produce is placed either in a room surrounded by a "ac$et of
cold air, or in a tan$ surrounded by a "ac$et of cold liquid.
"et cooling
quic$2chilling process using air at very high speed forced around the products, usually
while those products are continuously moving on a conveyor belt. Compare air2blast
cooling.
magnetic cooling
cryocooling by adiabatic demagneti0ation of certain paramagnetic substances.
natural convection cooling
1. cooling a fluid by natural convection over the cooling surface.
2. cooling a spa$e "y means of air $oo#ed "y nat!ra# $on)e$tion%
oil cooling
transfer of heat from oil in pipe or tubing to a refrigerant or brine.
precooling
cooling fruits and vegetables prior to free0ing or prior to shipment, before or after they
enter a shipping carrier.
pressure cooling
process that forces cold air under pressure, but at low speed, into pac$ages
containing produce to be cooled.
radiant cooling system panel air system!
system using panel coolers to absorb radiant heat.
recooling
cooling of air that has been previously heated.
regenerative cooling
process of using heat that must be re"ected or absorbed in one part of the cycle to
perform a useful function in another part of the cycle.
roof spray cooling
system that reduces heat gain through a roof by cooling the outside surface with a
water spray; suited for only temporary treatment, because high humidity may be
introduced by air inta$es on the roof.
spot cooling
cooling the air of a limited portion of an enclosed space without the use of walls or
partitions.
spray cooling
cooling by spraying a low2temperature liquid on the ob"ect to be cooled.
subcooling
cooling a substance below its saturated condition or its free0ing temperature.
surface cooling
method of cooling air or other gas by passing it over cold surfaces.
transpiration cooling
cooling produced by evaporation of water lost by a body.
vacuum cooling vacuum chilling!
cooling by vapori0ation under vacuum of part of the water contained in the material to
be cooled.
waterside economi0er cooling
economi0er process that uses cooling2tower water directly or indirectly in the cooling
coils, permitting the chiller to be shut down when the outside wet2bulb temperature is
sufficiently low.
cooling capacity total cooling capacity!
design maximum rate, expressed in watts, at which equipment removes heat from the
air passing through it under specified conditions of operation.
latent cooling capacity
design maximum rate at which equipment removes latent heat, or reduces the
moisture content of air passing through it, under specified conditions of operation.
sensible cooling capacity
design maximum rate at which the equipment removes sensible heat.
cooling element
heat transfer unit containing refrigerating fluid in the location where refrigerating effect is
desired.
cooling medium
substance used, with or without a change of state, to lower the temperature of other
bodies or substances. &ee coolant.
cooling range
in a cooling process! difference between the average temperatures of a fluid entering
and leaving a cooler.
cooling rate
decrease in temperature in unit time.
cooling surface
surface that is lower in temperature than the fluid being cooled by contact with it.
cooling system
apparatus for lowering the temperature of a space or product to a specified
temperature.
direct cooling system
system in which the evaporator is in direct contact with the material or space
refrigerated, or is located in air2circulating passages communicating with such spaces.
indirect cooling system
system in which a liquid such as brine or water, cooled by the refrigerant, is circulated
to the material or space to be refrigerated, or is used to cool air so circulated.
radiant cooling system panel air system!
system using panel coolers to absorb radiant heat.
roc$2bed regenerative cooling system
system of air conditioning in which pac$ed beds of crushed stone or gravel are used
for both evaporative cooling and heat energy storage.
cooling tower
heat2transfer device, often tower2li$e, in which atmospheric air cools warm water,
generally by direct contact evaporation!.
atmospheric tower natural2draft cooling tower!
one in which air movement through the tower occurs by aspiration or natural
convection, as opposed to mechanical means.
counterflow tower
one in which air, drawn in through air inlets at the tower perimeter induced draft!, or
forced in forced draft! at the base by the fan, flows up through the fill material in a
direction opposite to the falling hot water.
crossflow tower
one in which air, drawn or forced in through the air inta$es by a fan, flows hori0ontally
across the fill section perpendicular to the falling hot water.
film cooling tower
cooling tower with a type of pac$ing over which the water spreads in a thin film.
forced2draft water cooling tower
type of mechanical draft tower in which one or more fans are located at the air inlet to
force air into the tower.
hyperbolic tower
cooling tower of hyperbolic shape which depends on natural draft for air movement
through the tower. It can be either crossflow or counterflow. &ee natural draft tower
cooling tower.
induced draft water cooling tower
type of mechanical draft tower in which one or more fans are located in the air outlet to
induce airflow through the air inlets.
mechanical draft water cooling tower
tower through which air movement is effected by one or more fans. %here are two
main types: forced draft with fans located at the air inlet; induced draft with fans
located at the air exhaust.
natural draft water cooling tower
one in which air movement is dependent upon the difference in density between the
entering air and internal air. 4s the heat of the water is transferred to the air passing
through the tower, the warmed air tends to rise and draw in fresh air at the base of the
tower. &ee hyperbolic tower.
splash filled tower
cooling tower with a type of pac$ing which repeatedly interrupts the flow of falling
water, brea$ing the water into fine droplets as it falls.
spray filled water cooling tower
tower which has no fill; water2to2air contact depends entirely on the brea$up of the
water by means of pressure2spray no00les.
water cooling tower
enclosed device for evaporatively cooling water by contact with air.
wet2dry cooling tower
wet evaporative! cooling tower in combination with a dry nonevaporative! heat
exchanger system, used to reduce or abate cooling tower fogging during cold weather
by modifying the tower exhaust air condition.
cooling tower fogging
fog condition created when the exhaust air or plume from a cooling tower, which is
essentially a saturated air2water vapor mixture warmer than ambient air, becomes
supersaturated so that part of the water vapor condenses into visible liquid droplets.
cooling tower pac$ing tower filling!
that part of a crossflow, counterflow, or natural2draft tower consisting of splash bars,
vertical sheets of various configurations, or honeycomb assemblies, tile, or other
materials, which are placed within the tower to effect heat and mass transfer between
the circulating water and the air flowing through the tower.
plate film fill! cooling tower pac$ing
closely spaced embossed or corrugated sheets.
splash cooling tower pac$ing
thin wooden bars of various materials and configurations causing water to brea$ up into
drops.
cooling tower plume
visible exhaust from a cooling tower. Compare cooling tower fogging.
critical nucleate boiling heat flux pea$ nucleate boiling heat flux!
heat flux for which the surface coefficient of heat transfer between a heating wall and a
liquid under nucleate boiling is a maximum. 4lso called maximum nucleate2boiling heat
flux. Compare gas binding.
critical process
processes with environmental control needs that are more constrained than occupancy
comfort parameters. =xamples of typical processes or areas that have unique needs
and are thus critical are: printing, paperma$ing, textiles, computer rooms, broadcasting
studios, food processing, medical and hospital areas, clean rooms, controlled
laboratories, unusual safety and health needs, explosive areas, cold storage, milling
and machining, casting, and glassma$ing.
critical speed
operating speed at which the vibration of a unit reaches an unacceptable limit.
critical velocity
1. )e#o$ity at whi$h 'i)en phenomena o$$!r%
2. in fluid mechanics, the velocity above which flow in a pipe is no longer laminar.
3. for he#i!m *He II+( the ma&im!m )e#o$ity at whi$h s!perf#!id f#ow $an "e maintained%
critical volume
specific volume at the critical point of a gas.
crosstal$
undesirable transfer of energy from active signal lines! to one or more independent
signal lines, creating signals that may reach proportions to cause system errors.
cryocooling cryogenic cooling!
cooling below 12, H R2'#)6!.
cryogenic equipment
everything used to produce or maintain cryotemperatures.
cryogenic liquid
liquefied gas below 12, H R2'#)6!.
cryogenics
science that deals with the production of very low temperatures and their effect on the
properties of matter.
cryogrinding free0e2grinding! process
grinding at low temperature of a substance that otherwise could not be ground or would
be spoiled by the temperature rise resulting from the operation.
cryohydrate
eutectic mixture of which one component is water. &ee also eutectic solution.
cryopump
device designed for producing ultrahigh vacuum by condensation or adsorption of a gas
at a very low temperature, usually below // H R#2,)6!.
cryostat
batch operating apparatus in which a cryogenic liquid or solid evaporates to maintain a
cryotemperature, which need not be constant but may vary in a predetermined fashion.
cryotrap
surface cooled below 12, H R2'#)6! in order to condense vapors. Can be used to
reduce pressure.
cusec ?cubic feet.second cf.s!@
unit of volume flow rate in pumping. 4n improper term. 1 cf.s 5 ''+.+# gpm 2+.#2 C.s!,
the preferred term.
cut2in
initiation of an event for which control is applied.
constant cut2in
used in refrigerating devices constructed to permit the cut2in point to remain constant
while providing a variable cut2out variable differential! range when the dial shaft is
turned.
cut2in point
predetermined value pressure, temperature, etc.! at which operation commences.
cut2out
1. cessation of an event for which control is applied.
2. device that causes the cessation, either manual or automatic.
#. time when a water heater thermostat has acted to reduce the energy or fuel input to
the heating elements or burners under its control to a minimum.
high2discharge temperature cut2out
safety device which acts when an abnormal rise in the discharge temperature starts an
alarm or stops the compressor.
high2pressure safety cut2out
switch designed to stop the compressor when the discharge pressure reaches a
predetermined high value.
low2pressure safety cut2out suction pressure safety cut2out!
switch designed to stop the compressor motor when the suction pressure reaches a
predetermined low value.
pressure differential cut2out
cut2out control reactive to the difference between two pressures.
cut2out point
predetermined value pressure, temperature, etc.! at which operation ceases.
C2value
improper term. 8se C2factor for thermal conductance.
cycle
1. interval of space, or time, or a sound wave in which one set of repetitive events or
phenomena is completed.
2. set of operations that is repeated regularly in the same sequence. %he operations
may be sub"ect to variations on each repetition.
#. complete series of values of a periodic quantity that occur during a period.
'. in alternating current, the time for a change of state from a 0ero through a positive
and a negative maximum, and bac$ to 0ero.
(. complete course of operation of wor$ing fluid bac$ to a starting point, measured in
thermodynamic terms functions!.
-. in the operation of a thermostat, the period of operation from cut2in to cut2in.
/. process or series of processes wherein the initial and final states of the system are
identical. %herefore, at the conclusion of a cycle, all the properties have the same
value as at the beginning. &ee also storage cycle.
closed cycle
one in which the fluid is used over and over without introduction of new fluid, typical of
a sealed system.
compressing cycle refrigeration!
refrigerating cycle comprising four principal stages: vapori0ation of the refrigerant;
compression of the vapor; liquefaction of the vapor; expansion of the liquid.
cycle of concentration
1. in boilers, the ratio of chlorides in the boiler water to the chlorides in the feedwater.
2. in cooling tower operation, the ratio of chlorides in the recirculating cooling tower
water to the chlorides in the ma$eup water.
defrosting cycle
duration of the Boff2cycleD of a refrigerating system sufficient to permit defrosting of a
cooling coil.
diesel cycle
in a two2 or four2stro$e reciprocating engine, air without fuel is compressed, usually to
more than (,, psig #(,, $>a!, to raise its temperature above the ignition
temperature of the fuel that is in"ected into the hot compressed air at or near the start
of the power stro$e. In modified diesel engines, a glow plug is used to aid ignition
when the engine is started.
Ftto cycle
in a two2 or four2stro$e reciprocating engine, the compressed fuel2air mixture is ignited
by a spar$ at or near the start of the power stro$e as in conventional automobile
engines.
reverse cycle
cycle obtained when a fluid is made to follow the different thermodynamic stages of a
cycle in the reverse order.
vapor "et steam "et! refrigerating! cycle
refrigerating cycle using an e"ector to compress the refrigerant vapor from the
evaporator to the condenser. %he term Bsteam "etD is used when water is the
refrigerant.
cycling
1. continuous oscillation occurring without periodic stimuli. 4 situation in a closed2loop
system where the controller output to an input change causes instability.
2. periodic change in the controlled variable from one value to another. 4lso called
hunting.
duty cycling electric!
process of turning off electrical equipment for predetermined periods of time during
operating hours to reduce consumption and demand.
cycling life
expected total duration of lifetime cycling expressed in time or number of events.
cylinder head
in a reciprocating engine, pump, or compressor, the end of a cylinder opposite to that
from which the piston rod or connecting rod pro"ects.
safety cylinder head
movable cylinder head retained in position by springs powerful enough to oppose
normal compression pressures, but capable of lifting in case of slugging.
daily range
difference between high and low temperatures for a typical day. 8sed in <E4C load
calculations.
damper
device used to vary the volume of air passing through an outlet, inlet, or duct; or
generally through a confined cross section by varying the cross2sectional area.
bac$draft damper shutter!
device which, when mounted in a duct or opening, permits the flow of air in one
direction only.
barometric damper
mechanically balanced damper that rotates from changes in pressure within
breeching to bleed air into the breeching to maintain a steady draft.
blast gate damper
in an air2handling system, a sliding damper.
butterfly damper
1. damper consisting of a plate turning on a diametral axis inside a duct.
2. pair of flaps hinged to a common diametrical spindle and permitting flow in one
direction only.
ceiling damper
device to protect air openings in fire rated ceiling assemblies that operates to interrupt
airflow automatically in the event of fire to restrict passage of heat and flame.
equali0ing damper
device to maintain constant static pressure or volume flow.
fire damper
device that interrupts airflow automatically through part of an air system to restrict
passage of flame. Installed in a fire rated wall or floor and closes automatically in the
event of fire to maintain the integrity of the fire rated separation.
guillotine damper
isolation damper having a blade which is withdrawn from the duct area when the
damper is fully open.
muffler2noise damper
device intended to dampen noise; more particularly an expansion chamber in the
exhaust line of an internal combustion engine.
multileaf multiblade! damper multiple2louver!
damper having two or more blades.
single2leaf single2blade! damper
damper with a single blade.
slide damper
damper consisting of a plate that can be slid between two guides that are generally
perpendicular to the axis of the duct.
volume control damper
device mounted in a duct or opening used to vary the volume of air flowing through.
damper actuator motor!
device that provides the necessary force to position a damper.
damping
1. reducing the amplitude of vibrations by dissipating the corresponding mechanical
energy to some suitable absorbing sin$.
2. progressive diminution with time of certain quantities characteri0ing a phenomenon.
darcy unit
measure of permeability. 4t one darcy, a material will pass a fluid of one centipoise
viscosity through a section of one square centimetre at a rate of one cubic centimetre
per second, with a drop in pressure of one standard atmosphere.
data
1. general term used to denote any or all facts, numbers, letters, and symbols that refer
to or describe an ob"ect, idea, condition, situation, or other factors.
continued on next page!
2. representations such as characters or analog quantities to which meaning might be
assigned.
analog data
data represented in a continuous form, as contrasted with digital data represented in a
discrete discontinuous! form; an analog of the variable represented.
data ban$
any electronic depository of data.
data base
ordered and named collection of data particularly for use in computeri0ed information
systems.
data display module
device that stores computer output and translates this output into signals which are
distributed to a program2determined group of lights, annunciators, and numerical
indicators in operator consoles and remote stations.
data logging
1. device used for collection of characters or analog signals.
2. recording of data about events that occur in time sequence.
#. real2time processing! processing of data in synchronism with a physical process so
that the results of the data processing are useful to the physical operation.
data processing device machine!
general name for a machine which can store and process numeric and alphabetic
information.
peripheral data processing device
1. unit or equipment distinct from the central processor.
2. console device that is not a part of the central processor, but is connected to the
central electronics processor function cards via the console cabling system or other
input2output means, i.e., the $eyboard, visual display, teletypewriter, pro"ector, pilot
lights, C1% display, and tape reader.
data reduction
process of transforming masses of raw test or experimentally obtained data, usually
gathered by automatic recording equipment, into useful, condensed, or simplified
intelligence.
data table
collection of data with each item uniquely identified either by some label or by its relative
position.
dead air poc$et dead 0one!
stagnant area in a space unaffected by air circulation.
dead band dead 0one!
range of values within which an input variable can be varied without initiating any
noticeable change in the output variable.
dead time lag time!
time interval between a change in the input variable and the initiation of the
corresponding change in the output variable.
debug
1. to operate equipment prior to use to detect and replace parts that are defective or
expected to fail, and to correct error in fabrication or assembly.
2. to isolate and remove a mista$e or malfunction.
decay rate
any physical attribute that decreases with time in a regular fashion. 4n example is the
rate of decay of the concentration of a tracer gas, as used to measure the air infiltration
rate of a building. &ee also sound decay rate.
decibel
unit used in acoustics for expressing the relation between two amounts of airborne
power. Iy definition, the difference in decibels between two powers >1 and >2, >2 being
the larger is: db difference 5 1, log to the base 1,! >2.>1.
declination of sun
angle of the sun above or below the equatorial plane. It is plus if north of the plane and
minus if south.
decrement
1. quantity by which a variable is decreased.
2. specific part of an instruction word in some binary computers; thus, a set of digits.
deflector turning vane!
fixed or ad"ustable device, usually in a duct, to change direction of airflow.
defrosting
planned process to remove or prevent accumulation of frost ice! on coils of
refrigerating units.
automatic defrosting
defrosting automatically at set intervals, based on time or temperature conditions, or
both.
electrical defrosting
defrosting by means of electrical heating.
external defrosting
defrosting using heat from external sources.
hot2gas defrosting internal defrosting!
method which utili0es heat from inside the pipes of the evaporator, usually the highly
superheated vapori0ed refrigerant from the compressor.
manual defrosting
defrosting by natural or manual means with manual initiation and termination of overall
defrost operation.
off2cycle defrosting
1. method of defrosting in which the temperature of the evaporator coils is allowed to
rise naturally during an Boff cycle,D no refrigerant being supplied.
2. rapid heating of the evaporator coil during the off part of each cycle.
reverse2cycle defrosting
defrosting an evaporator by reversing its function with that of the condenser.
semiautomatic defrosting
defrost system in which the defrost cycle is started manually and ends automatically
with automatic resumption of normal refrigeration at the end of defrost operation.
thermoban$ defrosting
use of a storage tan$ heated by compressor discharge gas during normal
refrigeration, to evaporate liquid produced during hot gas defrosting, thus preventing
liquid from returning to the compressor.
time defrosting
defrosting process automatically and intermittently operated for a predetermined
period.
time2initiate, temperature2terminate defrosting
process which starts the defrost cycle at a predetermined time or intervals and by a
thermostat, and stops when the heated coils reach a set temperature.
time2initiate, time2terminate defrosting
process which starts and stops the defrost cycle at a predetermined time or intervals,
but has no thermostatic control for the heating coil.
water defrosting
defrosting in which water is sprayed or poured over the frosted surface.
defrosting system
equipment and controls designed to remove frost ice! from cooling coils of a
refrigerating system.
demand defrost
automatic defrosting system in which the defrost cycle is initiated by a drop in
performance of the refrigerating system.
degradation
failure of a superconductor to carry the current which would be expected from a
$nowledge of the critical current field relationship of that material.
degree2day 77!
difference in temperature between the outdoor mean temperature over a 2'2hour
period, and the given base temperature of a building space. Compare $elvin day.
cooling degree2days C77!
sum of the degree2days for cooling, using a common base of /()6 2()C in Canada!,
is used with other factors to evaluate the energy requirements of a cooling season.
heating degree2days <77!
sum of the degree days for heating, using a common base of -()6 1+)C in Canada!,
used with other factors to evaluate the energy requirements of a heating season.
infiltration degree2day )62day; )C2day!
measure of the severity of the climate as it relates to building air infiltration.
degreening
imposed transformation from a green color to a yellow or orange color especially with
citrus fruits!, due to destruction of chlorophyll.
degrees of freedom
number of variables necessary to determine the state of individual phases less
the number of phases more than one. =quals two plus independent components minus
number of phases.
dehumidification
removal of water vapor from air.
dehumidifier
air cooler, or an absorption or adsorption device used for lowering moisture content.
surface dehumidifier
1. dehumidifier with a surface at a temperature below the dew point.
2. air2conditioning unit, designed primarily for cooling and dehumidifying air by
passing the air over cooling coils that are below the dew point of the air.
dehumidifying effect
mass of water condensed during cooling or the equivalent refrigerating capacity
expressed in terms of the latent heat of the water condensed per unit of time.
dehydration drying!
removal of water from any substance.
dehydrator drier!
device for removing moisture from refrigerant or other substance.
demand demand load!
electric power delivered to or by a system, part of a system, or a piece of equipment;
expressed in $ilowatts, $ilovolt2amperes, or other suitable unit at a given instant or
averaged over any designated period.
demand2limit tripping electric!
1. process of, or equipment for, automatically opening an electric2service disconnect
device
2. removing interruptible or deferrable loads! at the user level when electric power or
current flow to that user, or to a portion of the load, exceeds a specified level for more
than a specified time, as determined by agreement. %he automatic function can be
enabled or disabled remotely by the serving utility via centrali0ed communication.
demand limiter
electrical.electronic, mechanical, or electromechanical device that monitors user
electric power demand and causes that demand to be limited in a manner not to exceed
a selected or programmed maximum value.
demodulation
modulation process wherein a wave resulting from previous modulation is employed to
derive a wave having substantially the characteristics of the original modulating wave;
sometimes used to describe the action of a frequency converter or mixer, but this use is
deprecated.
density
1. mass per unit of volume.
2. measure of the light transmitting or reflecting properties of an area. Compare specific
gravity.
desiccant
absorbent or adsorbent, liquid or solid, that removes water or water vapor from a
material.
activated alumina desiccant
form of aluminum oxide, readily used as a drying agent, which absorbs moisture.
phosphorous pentoxide desiccant >2F(!
although an effective drying agent, it becomes gummy on reacting with moisture so is
not used as a drying agent in refrigerating systems.
silica gel desiccant aerogel!
form of silicon dioxide which absorbs moisture and may be used as a drying agent.
desiccation
1. process for evaporating water or removing water vapor from a material.
2. complete removal of water from a material.
design airflow
required airflow when the system is operating under assumed maximum conditions of
design, including diversity.
design conditions
specified environmental conditions, such as temperature and humidity, required to be
produced and maintained by a system.
design professional
individual responsible for the design and preparation of architectural or engineering
contract documents.
design professions environmental!
professions collectively responsible for the design of human physical environment,
including architecture, engineering, landscape architecture, urban planning, and similar
environment2related professions.
architect licensed architect!
designation reserved, usually by law, for a person or organi0ation professionally
qualified and duly licensed to perform architectural services, including but not
necessarily limited to analysis of pro"ect requirements, creation and development of
pro"ect design, preparation of drawings, specifications and bidding requirements, and
general administration of the construction contract.
architect2engineer
individual or firm offering professional services as both architect and engineer.
field engineer
term used by certain governmental agencies to designate their representative at the
pro"ect site.
prime professional
person or entity having a contract directly with the owner for professional services.
professional engineer licensed engineer!
designation reserved, usually by law, for a person professionally qualified and duly
licensed to perform engineering services such as civil, electrical, mechanical, sanitary,
and structural.
pro"ect architect
architect designated by the principal2in2charge to manage the firmPs services related
to a given pro"ect.
pro"ect engineer
engineer designated to be responsible for the design and management of specific
engineering portions of a pro"ect.
resident engineer
engineer employed by the owner to represent the ownerPs interests at the pro"ect site
during the construction phase.
registered engineer
appropriately qualified and licensed professional engineer.
desorption
liberation of a gas held in a substance by sorption.
deviation
difference between the set point and the value of the controlled variable at any instant.
standard deviation
square root of the average of the squares of the deviations from the mean root2meansquare
deviation!; a measure of the dispersion of a population.
dew
1. deposit of water droplets on cold surfaces formed by the condensation of water
vapor.
2. hydrometeor produced on ob"ects at or near the ground.
7ewar vacuum! flas$
silvered glass flas$ with double walls with the space between them highly evacuated.
dew2point depression
difference between dry2bulb temperature and dew2point temperature.
dew2point rise
increase in moisture content specific humidity! of air expressed in terms of a rise in
dew2point temperature.
dial
1. industrial control! a plate or dis$, suitably mar$ed, that serves to indicate angular
positions, as for example the position of a handwheel.
2. automatic switching! type of calling device used in automatic switching that, when
wound up and released, generates pulses required for establishing connections.
diathermanous
pertaining to the nature of a substance or a space which allows the passage of heat
more particularly radiant heat!.
dielectric strength
maximum electric field that an insulator can withstand without brea$down.
differential
1. of a control, the difference between cut2in and cut2out temperatures or pressures.
2. range which the controlled variable must pass in order to actuate the control element.
operating differential
difference between the cut2out and cut2in at the sensing element.
diffuse flux!
indicates that radiant flux propagates in many directions as opposed to a single
direction; as in a direct beam, which refers to collimated flux.
diffuser
1. circular, square, or rectangular air distribution outlet, generally located in the ceiling
and comprised of deflecting members discharging supply air in various directions
and planes and arranged to promote mixing of primary air with secondary room air.
2. duct of increasing area following the outlet of a rotary blower so that the reduced
velocity of the fluid will convert some of the $inetic energy into pressure energy.
&ee also air outlet.
ceiling diffuser
supply2air diffuser designed for ceiling mounting.
slot diffuser
elongated type of air diffuser consisting of a single or a number of slots.
diffuser radius of diffusion
hori0ontal distance air throw! from a ceiling air diffuser to the point of preset terminal
velocity of the air.
diffusion
1. displacement of the molecules of a fluid within another fluid.
2. distribution of air within a space by an outlet discharging supply air in various
directions and planes.
diffusion area
effective area covered by a "et of air on leaving a distribution outlet.
digital display
data displayed by alphanumeric display instead of a dial indicator or meter.
digital indication
1. digital display.
2. direct numeric readout of a measurable property or condition.
#. displaying of data in an electrical readout based on the use of discrete integral
numbers.
digital transmission
transmission of data in a serial format of two discrete signal levels on a discrete time
interval.
diluent
neutral fluid added to another fluid to reduce the concentration of the second fluid in a
mixture.
dimensionless number
ratio of various physical properties such as density or heat capacity! and conditions
such as flow rate or mass!, of such nature that the resulting number has no defining
units of mass, rate, etc. 4lso called a nondimensional parameter.
direct drive
in a machine, the drive and the driven units are directly coupled, either by a common
shaft or by a mechanical coupling.
direct exhaust system
mechanical appliance venting system supplied or recommended by the manufacturer
through which the products of combustion pass directly from the appliance to the
outside, and which does not employ a means of draft relief.
direct vent system appliance!
system supplied by a manufacturer which provides outdoor air directly to a unit for
combustion and for draft relief, if the unit is equipped with a draft control device, and
which provides for discharge of all flue gases to the outside atmosphere.
discharge line hot2gas line!
line through which refrigerant vapor flows from a compressor to a condenser.
discharging thermal storage!
withdrawing cooling or heating capacity from storage.
compressor2aided discharging
operating the compressor of an ice storage system during the discharging period.
distribution system
1. conveying means, as ducts, pipes, wires, to bring substances or energy from a
source to the points of use.
2. parts of a cooling tower, beginning with the inlet connection, that distribute the hot
circulating water within the tower to the points where it contacts the air.
distributor
device for dividing flow of fluids into parallel paths.
district cooling
concept of providing and distributing, from a central plant, cooling to a surrounding area
district! of tenants or clients residences, commercial businesses, or institutional sites!.
district cooling system cooling density
measure of cooling demand per unit area. Customary units are $K.hectare, or tons.
acre.
district heating
concept of providing and distributing, from a central plant, heating to a surrounding area
district! of tenants or clients residences, commercial businesses, or institutional sites!.
Compare district cooling.
geothermal district heating
use of geothermal energy passing through a heat exchanger to a secondary loop,
from which the secondary fluid is circulated through the distribution system.
low2temperature district heating
use of fluids less than (,)C 2,,)6! in round numbers! for district heating supply;
permitting use of energy sources formerly discarded.
waste2heat reclamation district heating
use of collected heat from an available process as a source for a district heating
system.
district2heating system heating density
meas!re of heatin' demand per !nit area% C!stomary !nits are 542he$tare or
1t! ⋅ 1/:2a$re%
domestic
ad". refers to use in residential and small commercial buildings.
double brea$
1. condition that results when a switching device opens an electrical circuit by providing
two gaps in a single supply line. continued on next page!
2. brea$er arrangement whereby dual circuit brea$ers are used to reduce li$elihood of
extended power outages of any circuit due to circuit brea$er trouble; permits brea$er
maintenance without a feeder outage.
double line brea$
loss of continuity in a double2line system. &ee double brea$.
double suction riser
in a compressor, a riser arrangement designed to assure adequate oil return at all
conditions of refrigerant flow.
draft
current of air, when referring to:
1. pressure difference that causes a current of air or gases to flow through a flue,
chimney, heater, or space.
2. locali0ed effect caused by one or more factors of high air velocity, low ambient
temperature, or direction of airflow, whereby more heat is withdrawn from a personPs
s$in than is normally dissipated.
#. change in cross section that occurs during rolling or cold drawing of metals.
balanced draft
two fans connected to a combustion unit, one to supply the combustion air and the
other to induce draft.
forced draft
combustion air supplied under pressure to the fuel burning equipment.
induced draft
fan exhaust of hot gases from the heat absorbing equipment.
natural draft
airflow resulting from the difference between atmospheric density and some lower
density existing in the furnace or gas passages of heat generating unit, chimney
effect.
draft hood
device not an integral part of a furnace or boiler, connected to the furnace or boiler by a
short length of flue pipe. It is designed to 1! provide for the exhaust of products of
combustion in the event of no draft, bac$ draft, or stoppage beyond the draft hood; 2!
prevent a bac$ draft from entering the furnace; #! neutrali0e the effect of stac$ action of
the chimney or gas vent upon the operation of the furnace.
draft hood relief opening
opening provided in draft hood to permit the ready escape to the atmosphere of the fuel
gases in the event of no draft or stoppage beyond the draft hood, and to permit
inspiration of air into the draft hood to neutrali0e strong chimney or vent updraft.
draft regulator see regulator.
draft relief
1. provision for drafts to escape the venting system of a boiler or furnace.
2. relief or taper given to a pattern, die, or mold to enable the wor$ to be easily
withdrawn.
drain pan
vessel or tray placed under an evaporator coil to receive condensed moisture, melted
frost, or ice. 4lso called drip tray, defrost pan.
drawing
graphic and pictorial document showing the design, location, and dimensions of the
elements of a pro"ect.
axonometric drawing
perspective drawing showing plan and partial elevations on the same drawing.
clarification drawing
1. graphic interpretation of the drawings or other contract documents issued by the
architect.
2. drawing to correct an ambiguity in a previous drawing.
detail drawing
drawing, at a larger scale, of a part of another drawing, indicating in detail the design,
location, composition, and correlation of the elements and materials not shown on the
smaller scale.
elevation drawing
two2dimensional graphic representation of the design, location, and dimensions of a
pro"ect, or parts thereof, seen in a vertical plane viewed from a given direction.
isometric drawing
form of three2dimensional pro"ection in which all of the principal planes are drawn
parallel to corresponding established axes and at true dimensions.
orthographic drawing
plan and elevation detail drawing.
perspective drawing
graphic representation of a pro"ect or part thereof as it would appear threedimensionally.
plan drawing!
two2dimensional graphic representation of the design, location, and dimensions of a
pro"ect, or parts thereof, seen in a hori0ontal plane viewed from above.
preliminary drawing
drawing intended for use during the early stages of the design of a pro"ect, and not to
be used for construction.
record drawing
construction drawing revised to show significant changes made during the
construction process, usually based on mar$ed2up prints, drawings, and other data
furnished by the contractor or anyone who prepared the original drawings.
rendering
drawing of a pro"ect or portion thereof, with an artistic delineation of materials, shades,
and shadows.
schematic design drawing
drawing illustrating the relationship of pro"ect components.
section drawing
drawing of a surface revealed by an imaginary plane cut through a pro"ect, or portion
thereof, in such a manner as to show the composition of the surface as it would
appear if the part intervening between the cut plane and the eye of the observer were
removed.
shop drawing
drawing, diagram, schedule, and other data specially prepared for the wor$ by the
contractor or any subcontractor, manufacturer, supplier, or distributor to illustrate
some portion of the wor$.
study drawing!
preliminary s$etch or drawing to facilitate the development of a design.
topographic survey drawing!
configuration of a surface, including its relief and the locations of its natural and manmade
features, usually recorded on a drawing showing surface variations by means of
contour lines indicating height above or below a fixed datum.
wor$ing drawing
drawing suitable for actual construction.
drier dehydrator!
1. device in a refrigerating system that contains a desiccant.
2. desiccant or refrigeration device placed in the main air line of a pneumatic control
system to reduce moisture. Compare desiccant. &ee also dryer.
drift
1. change in mechanical or electrical characteristics with the passage of time, change in
temperature, or both.
2. movement of current carriers in a semiconductor under the influence of an applied
voltage.
#. change in output2input relationship over a period of time with the change unrelated to
input, environment, or load.
'. in a cooling tower, water lost as liquid droplets entrained in the exhaust air. It is
independent of water lost by evaporation.
drift eliminator carryover eliminator!
assembly constructed of any suitable material which serves to remove entrained
moisture from the discharged air.
drip tray defrost pan!
vessel or tray placed under the cooling coil to receive the melt from frost or ice. 4lso
called drain tray.
drive
means for giving motion to a machine or machine part.
droop
1. linear term referring to the percentage decrease in output voltage for a square wave
or rectangular wave as a function of time. 4lso can apply to voltage error caused by
lea$age in a sample and hold circuit.
2. deviation from the no2load control point that results from a change in the heating or
cooling load.
dryer
appliance that removes moisture. Compare drier.
dry ice
solid carbon dioxide, CF2. 4 proprietary term.
duct
1. tube or conduit for conveying or encasing purposes.
continued on next page!
2. passageway made of suitable material, not necessarily lea$2tight, used for conveying
air or other gas at low pressures.
air duct
tube or conduit for conveying air. 9ote: 4ir passages of self2contained systems are not
recogni0ed as air ducts. &ee also warm air duct.
flexible duct
flexible passageway used to connect an air distribution duct to an outlet or diffuser.
outside air inta$e duct
duct which delivers outside air to a central installation or air2conditioning apparatus.
pipe duct
tube or conduit for encasing pipe.
warm air duct
1. in commercial refrigerators, the passage through which warm air ascends from
storage space to the bun$er.
2. in heating, ventilating, and air conditioning, pipes or ducts for conveying warm air
into or out of a space or room.
wire duct
tube or conduit for encasing wire.
duct brea$out noise
transmission or radiation of noise from some part of a duct system to an occupied space
in the building. 4lso called flan$ing, and duct radiation.
duct si0ing
calculation of dimensions of ducting for a given air distribution system.
equal2friction method duct si0ing
method in which ducts are si0ed so that their frictional resistance per unit length is
constant.
static regain method duct si0ing
method in which ducts are si0ed so that the regain in static pressure due to decreased
velocity between two points totally or partially compensates for the frictional resistance
between the points.
velocity2reduction method duct si0ing
method in which ducts are si0ed so that selected velocities occur in specific duct
lengths.
duct transition section
section of duct, breeching, or stac$ used to connect those elements with structures of
different cross2sectional dimensions.
dummy product
in testing, material used for filling refrigerator spaces not occupied by test pac$ages.
dunnage
strips of wood or other material placed between stored materials to permit air circulation
between them. &ee also cargo dunnage.
dust
air suspension aerosol! of solid particles, usually with particle si0e less than l,,
micrometres. &ee air contaminant.
dust eliminator
device, usually applied at a dust2generating source, that traps dust particles suspended
in the air or gases passing through it. Compare filter.
dust extracting plant
system that traps dust particles in the gas or airstream passing through it.
dust spot opacity
percentage decrease in light transmission of a dust2spot sampling target relative to the
light transmission of the clean target at any chosen amount of dust accumulation on the
target.
dust spot opacity index
number which expresses the relative dust accumulation on a dust2spot sampling target,
corrected for the nonlinearity of opacity increase, at constant dust accumulation rate.
ebullator turbulator, turbulence promoter!
device inserted in flooded evaporator tubes to prevent the evaporator from becoming
oil2bound or the refrigerant liquid from becoming quiescent at a pressure lower than its
boiling point.
economi0er
1. device that, on proper variable sensing, initiates control signals or actions to
conserve energy. 9ote: %he economi0er decision should be made at a fixed outside
air temperature, or by comparing return and outside air temperatures, or by
comparing the return and outside air total heat enthalpy!.
2. control system that reduces the mechanical heating and cooling requirement. 8sually
refers to use of outside air, but with logic to maintain a fixed minimum of outside air
and to ta$e only the minimum amount of outside air when the total heat of the return
air exceeds the total heat of the outside air.
compression economi0er
device that reduces compressor energy use by introducing intermediate pressure gas
into the compressor during the compression stro$e.
fan economi0er defrost!
device that prevents operation of the fan motor on a cold defrost during the shutdown
period after the coil has been defrosted.
feedwater economi0er
feedwater heater installed in the hot2gas duct between the boiler and the stac$ to
transfer a portion of the heat that would be lost up the stac$! to the feedwater.
economi0er cycle
integrated economi0er cycle
cycle logic that uses the economi0er mode in con"unction with mechanical cooling,
typically based on return and outside air total heat.
waterside economi0er cycle
economi0er cycle that uses the condenser water side of the system. &ee also cooling.
eddy current
electric current induced in the body of a conductor when that conductor either moves
through a nonuniform magnetic field or is in a region where there is a change in
magnetic flux.
eddy current test
nondestructive test in which the change of impedance of a test coil brought close to a
conducting specimen indicates the eddy currents induced by the coil, thereby indicating
certain properties or defects of the specimen; for example, thic$ness.
eddy flow
see flow turbulent!.
e"ector
in a fluid2carrying pipe, a device with a reduced diameter to increase the fluid velocity
sufficiently to induce a lower static pressure at that point to draw another fluid into the
line. &ee also in"ector; venturi.
steam "et air e"ector
device for air removal from closed vessels in which the operating pressure is less than
atmospheric.
elastomer
material that can be stretched mar$edly and repeatedly and, immediately on release of
the stress, returns to its approximate original length.
electrical conductance
reciprocal opposite! of resistance. %he current carrying capacity of any wire or
electrical component.
electrical conductor common neutral
neutral electrical conductor that is common to, or serves more than one, circuit.
electrical degree
#-,th part of the angle subtended at the axis of the machine by two consecutive field
poles of li$e polarity. Fne mechanical degree thus equals as many electrical degrees as
there are pairs of poles in the machine.
electrical demand
1. $ilowatt load averaged over a specified time usually 1( or #, minutes!. %he demand
for any given interval is that value of power in $ilowatts that, if held constant over the
interval, accounts for the same consumption of electrical energy as the real power.
%he average of the real power over the demand interval. %his is commonly identified
as the bloc$ interval method.
2. electric power utili0ation! load integrated over a specified time interval.
#. installation or system! load at the receiving terminals averaged over a specified
interval expressed in $ilowatts, $ilovolt2amperes, $ilovars, amperes, or other suitable
units.
electrical diagram
1. diagram that shows the connections of an installation or its component devices or
parts.
2. diagram that shows, by graphic symbols, the electrical connections and functions of a
specific circuit arrangement.
#. diagram in the form of a vertical ladder with the outer vertical lines representing the
electrical supply conductors and the hori0ontal steps representing each individual
circuit with all component devices.
'. diagram showing where wires go. It may show physical location, terminal symbols,
and color codes.
electrical enclosure
case enclosing electrical equipment and wiring which is designed expressly to prevent
1! a person from accidentally contacting uninsulated energi0ed parts; 2! burning or
molten materials from contacting ad"acent combustible materials or falling onto
combustible materials; #! conductive or combustible materials from dropping on
uninsulated energi0ed parts; and '! mechanical abuse of electrical equipment not
designed or approved to withstand the intended normal use without such additional
enclosure.
electrical fault
short circuit, either line2to2line or line2to2ground.
electrical induction
process of producing electron flow by the relative motion of a magnetic field across a
conductor.
electrical insulation
material having high electrical resistivity and therefore suitable for separating ad"acent
conductors in an electric circuit, or preventing possible future contact between
conductors.
electrical resistance omega!
opposition that limits the amount of current that can be produced by an applied voltage
in an electrical circuit, measured in ohms.
electrical resistor
1. electrical component which adds resistance to an electrical networ$.
2. material used to produce heat or reduce voltage by passing a current through it.
electrical volume resistivity
electrical resistance of a substance contained between flat, parallel electrodes,
multiplied by the area of the electrodes and divided by the thic$ness of the substance.
electric current
movement or flow of charge in an electrical circuit, measured in amperes.
alternating current
electric current that reverses its flow periodically. &ee frequency.
direct current
current in an electrical circuit that does not reverse polarity. 9ote: 7irect current is said
to flow from positive to negative, but electrons travel from negative to positive.
electric current single phasing
interruption of any one conductor in a three2phase system.
electric power
time rate of generating, transferring, or using electric energy, expressed in watts K! or
$ilowatts $K!.
apparent power
product of the volts and amperes of a circuit. %his product generally is divided by 1,,,
and designated in $ilovolt2amperes $E4!. It comprises both real and reactive power.
reactive power
portion of apparent power that does no wor$. It is measured commercially in $ilovars.
1eactive power must be supplied to most types of magnetic equipment, such as
motors. It is supplied by generators or by electrostatic equipment, such as capacitors.
real power
energy or wor$ producing part of apparent power. %he rate of supply of energy,
measured commercially in $ilowatts. %he product of real power and length of time is
energy, measured by watt2hour meters, and expressed in $ilowatt2hours $Kh!.
electric power demand charge
part of an electric bill based on $ilowatt demand and the demand interval, expressed in
dollars per $ilowatt. 9ote: 7emand charges offset construction and maintenance of a
utilityPs need for large generating capacity.
electric power demand interval
period during which $ilowatt demand is monitored by a utility service, usually 1( or #,
minutes.
electric power demand load
actual load on a circuit at any time. &um of all loads which are F9. =qual to the
connected load minus the loads that are F66.
electric power demand period
electric power demand interval
on2pea$ period
1. time of day during which creating electrical demand incurs more cost.
2. time of day when use of power within a building is at a maximum; which may be the
pea$ period of either the consumer or of the utility.
off2pea$ period
time of day other than the on2pea$ period of electrical demand.
electric power generation
baseload generation
large, steady electric load of an electric system produced by the largest, most efficient,
generating facilities within the system. 9ote: %hese facilities are operated to the
greatest extent possible to maximi0e system mechanical and thermal efficiency, and
to minimi0e system operating costs.
cogeneration
any of several processes that either use waste heat from generation of electricity to
satisfy thermal needs, or process waste heat in the steam generation of electricity.
&ee also cogeneration.
on2site generation
generation of any electrical energy on customerPs property, with or without use of
recoverable heat.
electric power load factor =C6!diversity factor!
comparison of electricity use to electric demand. Calculated by dividing electricity usage
in $ilowatt2hours $Kh! by the product of electric demand in $ilowatts $K! times the
hours in the period under consideration.
electric power load shedding
control method of stopping selected power uses to avoid overloading power supply, or
to avoid demand charges.
electromotive force emf!
electric potential difference, measured in volts, between the terminals of any device
used as a source of electrical energy, i.e., to supply an electric current.
electropneumatic device
one that converts an electric signal to a pneumatic signal.
=AC&
energy monitoring and control system.
=AC& architecture
structure that lin$s hardware units, software pac$ages, sensors, control devices, and
other =AC& components into a system dedicated to perform the required control,
energy management, and management information functions on <E4C processes in
buildings.
=AC& end2to2end accuracy
accuracy with which the measured condition is displayed or recorded.
=AI electromagnetic interference!
electrical interference generated at radio frequencies inside systems. Compare 16I.
emulsion
relatively stable suspension of small but not colloidal particles of a substance in a liquid
with the suspended particles undissolved.
endothermic reaction
one in which heat must be supplied to further the reaction. Compare exothermic
reaction.
energy
1. capability for doing wor$.
2. capacity for producing an effect. <aving several forms, which may be either stored or
transient, and can be transformed from one into another. 6orms include thermal
heat!, mechanical wor$!, electrical, radiant, and chemical.
available energy
energy in the form of shaft wor$ or in a form completely convertible to shaft wor$ by
ideal processes.
chemical energy
1. energy possessed by a system caused by the arrangement of atoms composing
the molecules.
2. energy related to chemical phenomena in the formation and decomposition of
compounds, in the reactions that occur in electrochemistry.
electrical energy electricity!
energy derived from either moving or stationary electric charge, usually electrons;
measured in "oules. In the electric utility industry, measured in $ilowatt2hours $Kh!.
internal energy
sum of all $inetic and potential energies contained in a substance due to the states of
motion and separation of its several molecules, atoms, and electrons. It includes
sensible heat vibration energy! and that part of latent heat represented by the
increase in energy during evaporation.
$inetic energy
energy caused by the velocity of the molecules.
mechanical energy
capacity for doing wor$, usually expressed in wor$ units foot2pounds or newtonmetres!;
sometimes in heat units Itu or "oule!. =nergy may be inherent in the speed
of a body $inetic energy! or in its position relative to another body potential energy!.
new energy
energy, other than recovered, used for heating, cooling, or lighting.
nuclear atomic! energy
energy possessed by the system from the cohesive forces holding protons and
neutrons together as the nucleus of the atom.
potential energy
energy possessed by a system caused by the attractive forces existing between
molecules, or the elevation of the system.
radiant energy
energy passing through space in the form of electromagnetic radiation, such as light,
or ultraviolet or infrared radiation; or as a stream of particles, e.g., electrons or
protons.
thermal energy
energy possessed by a system caused by the motion of the molecules and.or
intermolecular forces; i.e., heat.
0ero point energy
residual energy of a system at absolute 0ero.
energy audit
identification and documentation of gross energy usage during a calendar period using
any of several means, such as source, department, product, equipment, and cost.
energy availability
maximum fraction of energy in a system that, in the presence of a medium at a given
temperature %,, can be converted into useful wor$ during a process at the end of which
the system temperature is %,.
energy cascading
multiple use of an energy stream for successive needs.
energy concept total energy system!
utili0ation of energy derived from a single fuel source for providing all energy services
such as generation of electricity, heating, and cooling.
energy factor
measure of overall efficiency in terms of energy output compared to energy
consumption over a 2'2hour cycle.
energy management function
effective management to achieve efficient use of energy in buildings.
energy management system =A&!
formal system of building energy conservation through all available means.
energy quality
temperature of an energy stream as a measure of potential energy.
district heating energy quality
temperature of the district heating energy stream as a measure of potential energy.
9ote: 3uality is a measure of both absolute and relative energy source potential: while
an energy stream at ()C is of lesser absolute quality than one at 1()C, the ()C stream
provides higher quality cooling potential relative to a 2,)C ambient.
energy recovered
energy used that would otherwise be wasted.
energy sources
conventionally, fossil fuels, hydro, nuclear, solar, geothermal, and wind.
alternative energy sources
nondepletable sources alternative to energy derived from combustible waste or heat
recovery processes.
nondepletable energy sources
sources of energy excluding minerals! derived from incoming solar radiation,
including photosynthetic processes, from phenomena including wind, waves and
tides, la$e or pond thermal differences, and energy derived from the internal heat of
the earth, including nocturnal thermal exchanges.
waste energy sources
collectively, energy available and thermally satisfactory for a heating, cooling, or
process requirement within an industrial site, partially degraded to ambient conditions,
and normally to be exhausted, drained, or removed from the site or thermally
converted and removed by the <E4C system.
enthalpy heat content!
thermodynamic quantity equal to the sum of the internal energy of a system plus the
product of the pressure2volume wor$ done on the system. h 5 = N pv, where
h 5 enthalpy or total heat content, = 5 internal energy of the system, p 5 pressure,
and v 5 volume.
specific enthalpy
enthalpy per unit mass of a substance.
enthalpy chart enthalpy diagram!
graphical representation of thermal properties of a substance with enthalpy as one of
the coordinates.
entropy chart entropy diagram!
graphical representation of thermal properties of a substance with entropy as one of the
coordinates.
entry loss
loss in pressure caused by a fluid stream flowing into a pipe, duct hood, or vessel.
en0yme
complex organic substance such as diastase, pepsin, etc.! capable of transforming
other compounds by catalytic action; a soluble ferment.
equali0er
1. piping arrangement on an enclosed compressor to equali0e refrigerant gas pressures
in cran$case and suction; also a device for dividing the liquid refrigerant between
parallel low2side coils; also a piping arrangement to divide the lubricating oil between
the cran$cases of compressor operating in parallel or in tandem.
continued on next page!
2. piping arrangement to maintain a common liquid level or pressure between two or
more chambers.
#. piping arrangement to equali0e steam header pressure and condensate return
pressure in a steam boiler.
external equali0er
in a thermostatic expansion valve, a tube connection from a selected control point in
the low2side circuit to the pressure2sensing side of the control element.
internal equali0er
in a thermostatic expansion valve, an integral internal part or passage whereby the
actuating element diaphragm or bellows! is exposed to pressure leaving the valve.
equation of time
difference between true solar time and local mean time as the result of earthPs orbit
about the sun. %he difference varies throughout the year, reaching a maximum of 1-
minutes during the first wee$ of 9ovember. &ee solar time true solar time!.
equilibrium
steady2state condition, during which the fluctuations of variables remain within
prescribed operating tolerances.
evaporative equilibrium
condition attained when the wetted wic$ of a wet2bulb instrument has reached a
stable and constant temperature. %his temperature approaches the true wet2bulb
temperature when the instrument is exposed to air at velocities over
*,, ft.min '.- m.s!.
mechanical equilibrium
equilibrium obtained in a system when the performance of the various components of
the system remains unchanged.
thermal equilibrium
equilibrium obtained in a system when the temperatures are nonvarying.
equilibrium point dryness =>7!
water contact of a liquid refrigerant after being in contact long enough to reach an
equilibrium state. =>7 is expressed as parts of water per million parts of refrigerant
ppm! on a mass basis.
equivalent length
resistance of fittings or appurtenances in a conduit through which the fluid flows,
expressed in length of straight conduit of the same diameter or shape that would have
the same resistance; also expressed in length.diameter units.
error bias!
1. incorrect step, process, or result.
2. difference between the true or actual value to be measured input signal! and the
indicated value output! from the measuring system. =rrors can be systematic or
random.
#. part of an erratum due to a particular identifiable cause; e.g., a truncation error
contrasted with mista$e. In a restricted sense, that deviation due to unavoidable
random disturbances, or to the use of finite approximations to what is defined by an
infinite series.
random error
statistical error caused by chance and not recurring. 4 general category for errors that
can ta$e values on either side of an average value. %o describe a random error, its
distribution must be $nown.
systematic error
persistent error not caused by chance; li$ely to have the same magnitude and sign for
every instrument constructed with the same components and procedures.
error band limit or span over which error can occur.
eudiometer
instrument for volumetric measurement and analysis of gases.
eupatheoscope
instrument for assessing comfort environment in terms of operative temperature.
eutectic
mixture of substances whose solid and liquid phases in equilibrium have identical
composition. &uch a mixture has a minimum free0ing point.
eutectic plate
thin, rectangular container containing eutectic mixture, generally with a coil to be
connected to a refrigerating system in order to free0e the mixture.
eutectic point
free0ing temperature of a liquid mixture which produces a solid phase of the same
composition.
eutectic solution
mixture that melts or free0es, normally at a specific temperature, with constant
composition. Its melting point is usually the lowest possible for mixtures of given
substances. &ee also cryohydrate.
evaporation
change of state from liquid to vapor.
equivalent evaporation
amount of water a boiler would evaporate, in pounds per hour $ilograms per second!,
if it received and vapori0ed feedwater at 212)6 1,,)C! and standard atmospheric
pressure. 8sed for comparison of different boilers.!
evaporation loss cooling tower!
water evaporated from the circulating water into the atmosphere by the cooling process.
evaporation rate
mass of substance evaporated per unit time.
evaporator
part of a refrigerating system in which the refrigerant is evaporated to absorb heat from
the contacting heat source.
circulation2type evaporator
flooded evaporator comprising a low2pressure receiver, in which the unvapori0ed
refrigerant returns to the evaporator inlet by gravity or by means of a pump or an
e"ector.
dry2expansion ?direct2expansion 7S!@ evaporator
refrigerant evaporator with organi0ed distribution, from which the refrigerant exits at a
vapor quality of one, usually with superheat. Compare flooded evaporator.
dry2type evaporator
continuous tube evaporator, in which refrigerant from a pressure2reducing device is
fed into one end, and the suction line connects to the outlet end.
embossed plate evaporator
evaporator in which the refrigerant passages are formed by sheets having pressed
corrugations and welded together.
flooded evaporator
refrigerant evaporator characteri0ed by no organi0ed flow, in which most of the
evaporator surface is in contact with the liquid refrigerant, and from which the
refrigerant exits at a vapor quality of one, without significant superheat. Compare
dry2expansion evaporator.
gravity circulating evaporator
organi0ed evaporator with circulation induced by a static head of liquid refrigerant
driving an opposing column of boiling refrigerant in the evaporator; sometimes
referred to as a thermosiphon.
herringbone E2coil! evaporator
evaporator in which the tubes, arranged in the vertical plane, are bent in the form of a
vee.
ice ban$ evaporator
evaporator immersed in water, on which an ice ban$ is formed.
liquid overfeed liquid circulation! system evaporator
evaporator feed system whereby refrigerant liquid is flashed to saturated suction
pressure and temperature in an accumulator and is then fed by a mechanical pump or
by refrigerant vapor pressure to the evaporators. %his liquid is normally fed at a rate
greater than the evaporation rate for the refrigerant to ensure wetting of the entire
evaporator surface for better heat transfer.
plate evaporator
evaporator consisting of two plates between which are arranged channels for the
circulation of refrigerant or of a tube grid welded onto a plate or sandwiched between
two plates.
pump fed evaporator
evaporator in which the refrigerant liquid is circulated by a mechanical pump.
recirculation2type evaporator
variant of the preferred terms, circulation2type evaporator, or liquid2overfeed
evaporator.
roll bond evaporator
evaporator consisting of two metal plates which are weld2bonded together with the
exception of the printed circuit forming the refrigerant passage which is obtained by
inflation under pressure.
shell2and2coil evaporator
closed cylindrical shell containing an evaporator coil which is in contact with the liquid
to be cooled.
shell2and2tube evaporator
evaporator in which the fluid to be cooled is passed through the tubes which are
immersed in the refrigerant.
spray2type evaporator
shell2and2tube evaporator in which the tubes are sprayed by liquid refrigerant.
starved evaporator condition when an evaporator does not receive sufficient refrigerant.
tube2in2sheet evaporator plate evaporator!
evaporator constructed from a pair of plates assembled to form a shallow
compartment containing a coil through which refrigerant flows, the fluid to be cooled
circulating in the compartment.
tube2on2sheet evaporator plate coil!
type of extended surface evaporator consisting of one or several metal sheets with a
coil through which refrigerant flows, bra0ed to one face.
vertical2type evaporator
evaporator consisting of a series of parallel tubes arranged vertically.
wrap2around evaporator
evaporator shaped to form an envelope around the space being cooled.
evaporator holdover
ability of an evaporator to stay cold after evaporation stops.
evaporator unit
assembly of refrigerating compressor, evaporator, and necessary accessories attached
to one base.
exchanger2diffuser
in controlled atmosphere storage, an apparatus with a membrane that enables
interchange of CF2 and F2 between controlled atmosphere rooms and the exterior, but
inhibits exchange of other gases.
excitation
1. armature current that induces the magnetic field in a rotating electric machine.
2. fans! external force applied to a system that causes the system to vibrate. &ee also
fan torsional excitation.
exergy
expression for the loss of available energy due to the creation of entropy in irrever2sible
systems or processes. %he energy loss in a system or component is determined by
multiplying the absolute temperature of the surroundings by the entropy increase.
exitance
total radiant flux that leaves unit area of a surface. %he sum of the radiant flux emitted
and reflected by the surface plus any radiant flux transmitted through that surface.
Compare radiosity.
spectral exitance
use radiance.
exothermic reaction
chemical reaction that releases more energy heat! than is required to start it. %he
combustion reaction burning! is an example, as are fission and fusion reactions.
Compare endothermic reaction.
expansion
increase in volume of a substance.
adiabatic expansion
expansion of a fluid during which no heat is exchanged with the surroundings.
dry expansion direct!
process of heat removal by a refrigerant in an evaporator fed by a flow control device,
responsive to temperature or pressure, or both, at some point in the evaporator, or
to the difference between high2 and low2side pressures and not to the liquid level in
the evaporator. 4ll entering refrigerant is evaporated before being recirculated. &ee
refrigerating system.
isenthalpic expansion
expansion of a fluid during which no heat or mechanical energy is exchanged with the
surroundings; the enthalpy remains constant.
multistage expansion
allowing refrigerant to pass through two or more expansion valves in series with each
other.
polytropic expansion
expansion of a fluid involving heat exchange.
thermal expansion
increase in one or more of the dimensions of a solid body or a liquid volume, caused
by a temperature rise.
expansion bend
bend, usually a loop, put into a pipe run to relieve stresses induced by expansion and
contraction from temperature changes.
expansion stro$e
part of the piston stro$e between the top dead center and the opening of the suction
valve.
expansion valve capacity
refrigerating effect in watts, Itu.h or tons 12,,,, Itu.h!, produced by the evaporation of
refrigerant passed by the valve under specified conditions.
expert system
computer programs that solve problems difficult enough to require human expertise, by
using a previously assembled $nowledge base and internal procedures. 4 form of
artificial intelligence.
face area
total plane area of the portion of a grille, coil, or other item bounded by a line tangent to
the outer edges of the openings through which air can pass.
facility cost
life cycle cost
cost of equipment over its entire life, including operating and maintenance cost.
replacement cost
estimate of the current or future cost to replace existing facilities either as currently
structured or as redesigned to embrace new technology with facilities that will perform
the same functions.
reproduction cost
estimated cost to reproduce existing facilities in their current form and capability at
current cost levels.
failsafe
1. position or mode of operation a controlled device ta$es on removal of the control
signal and.or power.
2. verb. to return to a position that, on loss of control system power, allows the
controlled system to exist in a safe manner.
fan
device for moving air by two or more blades or vanes attached to a rotating shaft.
&ee also impeller.
airfoil
fan shaped blade bac$wardly inclined or forward curved! in a fan assembly to
optimi0e flow, with less turbulence.
attic fan
exhaust fan to exhaust air near the top of a building while air, generally cooler, is
forced drawn! in at lower levels.
axial fan
fan that moves air in the general direction of the axis about which it rotates.
bifurcated fan
tubeaxial fan ducted! whose motor is mounted outside a bifurcated divided! duct with
only the blades of the fan located in the airstream.
blower fan
multibladed, driven rotor enclosed so that air from an inlet is compressed to a higher
discharge pressure, which depends on conformation of the blades and the shroud at a
given rotational speed. &ee also impeller.
centaxial fan
in2line duct fan with centrifugal blades, which can develop static pressures higher than
normal duct fans.
centrifugal exhauster
factory2assembled fan consisting of one or several centrifugal wheels directly
connected to a motor and enclosed in a housing. 4n inlet grille and bac$2draft damper
usually are included. Installation can be in a ceiling or wall.
centrifugal fan
1. fan in which the air enters the impeller axially and leaves it substantially in a radial
direction.
2. fan rotor or wheel within a scroll2type casing shroud! that includes supports for
either belt drive or direct connection.
circulating fan
free2flow propeller fan designed to circulate the air in a room without any air duct.
crossflow fan tangential fan!
fan in which air flows through the impeller at a right angle to its axis both on entering
and on leaving the impeller at its periphery.
exhaust fan
fan used to draw air from a space by suction.
induced draft fan I7 fan!
fan exhausting hot gases by suction, normally associated with combustion equipment.
mixed flow fan
fan whose characteristics combine both centrifugal and axial airflow.
plenum fan plug fan!
fan assembly consisting of a single inlet impeller, mounted perpendicular to airflow,
that pressuri0es a plenum chamber in an air distribution system. %he impeller is
typically an airfoil or bac$ward inclined design.
propeller fan
1. fan in which the air enters and leaves the impeller in a direction substantially
parallel to its axis.
2. propeller or dis$2type wheel within a mounting ring or plate and including driving
mechanism supports for either belt drive or direct connection.
tubeaxial fan
1. propeller or disc2type wheel within a cylinder and including driving mechanism
supports for either belt drive or direct connection.
2. axial fan whose blades revolve in a cylindrical casing. %he term Bducted fanD is used
when the casing is of substantial length.
tubular centrifugal fan
fan with a centrifugal impeller within a cylindrical housing discharging the gas in an
axial direction.
vaneaxial fan
fan with a dis$2type wheel in a cylinder, a set of air guide vanes located either before
or after the wheel, and drive mechanism supports for either belt drive or direct
connection.
wind turbine fan aeolian fan!
rotating wind2driven device.
fan air density
density of air corresponding to the total pressure and total temperature at the fan inlet,
when the fan is operating.
fan appurtenances
accessories added to a fan for purposes of control, isolation, safety, static pressure
regain, wear, etc. &uch appurtenances include inlet boxes, inlet box dampers, variable
inlet vanes, outlet dampers, vibration isolation bases, inlet screens, belt guards,
diffusers, sound attenuators, wear protection, turning gears, etc.
fan boundary inlet and outlet!
interface between the fan and the remainder of the system, at a plane perpendicular to
the airstream where it enters or leaves the fan. 4ppurtenances such as inlet boxes, inlet
vanes, inlet cones, silencers, screens, rain hoods, dampers, and discharge cones may
be included as part of the fan between the inlet and outlet boundaries.
fan blast area
fan scroll outlet area less the area of the cutoff.
fan casing volute, scroll!
part of the casing of a centrifugal fan or compressor that receives fluid forced outward
from the impeller or diffuser and leads it to the discharge.
fan coil unit fan convector unit!
fan and a heat exchanger for heating and.or cooling assembled within a common
casing.
fan curve
diagram showing the pressure.volume characteristics of a fan, and often the power
required by the fan.
fan free2discharge area
area where the fan chamber meets the discharge scroll. 8sed in fan system effect
calculations.
fan inlet outlet! area
area of the fan or fan equipment fitting provided for connection to attached ductwor$.
fan nodal line
line of 0ero vibration response on the fan such that the blades on opposite sides of the
line vibrate in opposite phase.
fan performance curve constant speed performance curve!
graphical representation of static or total pressure and power input over a range of air
volume flow rate at a stated inlet density and fan speed. It may include static and
mechanical efficiency curves.
fan power
power input at the fan shaft, or the total of the power input to the fan shaft and the power
loss attributable to the power transmission device.
fan pressuri0ation test
test for determining the air lea$age of a building using a fan2induced pressure
difference.
fan propeller
propeller or disc2type wheel within a mounting ring or plate, and including driving
mechanism supports for either belt drive or direct connection. Compare impeller.
fan shroud
protective housing which surrounds the fan and which may also direct the flow of air.
Compare fan casing.
fan sound power
sound power radiated into a duct.
fan static pressure
difference between fan total pressure and fan discharge velocity pressure.
fan torsional excitation
type of excitation in which external force is applied to the fan through the hub in the form
of torque pulsations.
fan total pressure
arithmetic difference between fan outlet total pressure and fan inlet total pressure.
fan wheel
revolving part of a fan or blower. &ee also impeller.
fan wheel cone
inlet ring, impeller shroud, impeller rim annular plate, or conical ring on the air inlet
side of a centrifugal fan to which the impeller blades are fixed.
feedbac$
1. returning of a fraction of the output to the input.
2. measurement of an output signal and feeding it bac$ as an input to modify the output.
feeder electric!
main distribution line, usually three2phase, supplying electric energy within an electric
service area or subarea.
fenestration
1. in an external wall of a building, any area which allows light to pass.
2. commonly used to refer to any opening, usually gla0ed, in a building envelope;
windows.
fenestration elements
1. framing, mullions, muntins, and dividers.
2. gla0ing material, either glass or plastic.
#. external shading devices.
'. internal shading devices.
(. integral between2glass! shading systems.
field2installed device 6I7!
microprocessor 77C! control panel, field mounted and connected. Compare product
integrated control.
field of view 6FE!
total angular dimensions within which ob"ects can be imaged, recorded, and displayed
by an imaging device when pointed in a fixed direction.
instantaneous field of view I6FE!
angle determined by dividing the si0e of the sensorPs detector by the effective focal
length of the sensorPs ob"ective lens system and multiplying by 1,,,. 4lso called
resolution element.
figure2of2merit 6FA!
performance rating that governs the choice of a device for a particular application, e.g.,
the efficiency of a material used in a thermoelectric device. &ee also part2load value.
film boiling
boiling phenomenon corresponding to the development of a continuous vapor layer on
the heating surface that separates this surface from the boiling liquid.
filter
1. device to remove solid material from a fluid.
2. capacitor and.or inductor placed in a series.parallel combination across a 7C line to
remove the effects of the 4C signal or to decrease the ripple voltage in a 7C power
supply.
#. device to remove gases from a mixture of gases.
absolute filter
filter having an efficiency of **.*,G or higher, capable of dealing with particle si0es
down to ,.,1 micrometre; a <=>4 filter.
brush filter
air filter in which the filter medium consists of a screen of brushes.
carbon filter filter that utili0es a mass of granulated activated carbon to adsorb certain
gases.
cellular filter cartridge filter!
air filter of "uxtaposed square or rectangular elements which can be easily dismantled
for cleaning or replacement.
cyclone filter
funnel2shaped device for removing particles from air or other fluids by centrifugal
means.
disposable filter
filter whose elements are discarded after use.
dry layer filter
filter having dry filtering medium as opposed to a viscous filter!.
electrostatic filter
filter in which the airstream is passed through a high2voltage ioni0ing field to impart an
electrical positive charge to particles, then collecting them on electrically negative
plates. &ee also precipitator.
fabric filter
filter having a textile2based filter medium.
fibrous filter fiber2pad filter!
filter having a fibrous medium of glass, cellulose, plastics, metal, etc.
<=>4 filter absolute filter!
high2efficiency particulate air filter.
impact filter
filter in which air is submitted to sudden changes of direction and speed, to induce
deposit of heavier particles on an adhering surface.
roll filter moving curtain filter!
filter in which the filter medium is a continuous belt on movable rolls to bring clean
filter area into the airstream, either automatically or manually.
suction2line filter
device installed in the suction line of a refrigerating system for the purpose of
removing solid contaminants. %he device generally consists of a shell with fittings and
an internal filtering element.
viscous filter
filter in which the medium is made from materials which have been impregnated with a
viscous oil.
filter cell filter cartridge; filter unit; filter element!
interchangeable frame or cylinder containing a filter medium.
filter drier filter dehydrator!
encased desiccant, generally inserted in the liquid line of a refrigerating system, and
sometimes in the suction line, to remove entrained moisture, acids, and other
contaminants.
filter medium
portion of a filtrating system that provides the liquid2solid separation, such as closewoven
textiles, metal screens, papers, nonwoven fabrics, granular beds, or porous
media.
filter mixing box
in air2handling units, a combination filter section outside air.return air mixing plenum,
including control dampers. Compare E4E box.
filter press
device for removing liquid from a slurry or suspension of solids under pressure with the
liquid expressed through screens or other filter media until the desired density of the
slurry is attained.
fin
thin piece of metal attached to a pipe, tubing, or other surface in order to increase the
heat transfer area. &ee also heat transfer surface.
inner fin
fin that is formed or fitted inside a tube.
integral fin
surface extension formed from the parent material at time of manufacture.
longitudinal fin
strip of material parallel to the axis of the tube to which it is fixed.
plate fin
plate drilled or punched to receive a number of parallel tubes with the purpose of
increasing the heat transfer area.
spiral fin helical fin; strip fin!
continuous strip of metal helically wound and attached to a tube.
fin pitch
number of transverse fins per unit length of tube.
fin spacing
distance between two successive transverse fins on a tube.
finned length
on a finned tube, the distance between the two end fins excluding lengths for return
bends and other overall lengths!.
finned surface area
total area of fins and prime surface of tube or plate to which fins are attached.
fire point
lowest temperature at which a product ignites and continues to burn for a specified time
after a small flame has been applied to its surface under standardi0ed conditions.
Compare flash point.
first2hour rating
amount of hot water that a water heater can supply in an hour of operation.
fitting system
part used to "oin, ad"ust, or adapt other parts as in a pipe or duct system.
flame impingement
condition existing when the flame resulting from the combustion of the fuel comes into
contact with any interior surface of the furnace.
flange
1. dis$ rim on the end of a pipe for coupling pipes together, usually by bolts.
continued on next page!
2. pro"ection of metal on formed ob"ects.
#. parts of a channel at right angle to the central section or web. &ee also pipe fitting.
blan$ flange
solid flange that has not been machined.
blind flange
flange used to seal the end of a pipe.
companion flange
pipe flange to connect with another flange or with a flanged valve or fitting. It is
attached to the pipe by threads, welding, or other method and differs from a flange,
which is an integral part of a pipe or fitting.
flat2face flange
smooth2faced flange used with gas$ets that cover the full face of the flange.
male2female flange raised face flange; 126 flange!
male flange carries a boss which fits into a corresponding recess in the female flange.
raised face flange
flange that provides a raised, usually serrated, gas$et surface.
tongue2and2groove flange
male flange carries a pro"ection that fits into a corresponding groove in the female
flange.
weld2nec$ flange
flange with a small collar to provide for a butt2weld connection.
flan$ing transmission sound!
reduction in apparent sound transmission loss of a wall caused by being carried around
the wall by other paths structure2borne, lea$s, etc.!. &ee also duct brea$out noise.
flare nut
nut used to hold flared tubing on a flare fitting.
flaring tool flaring bloc$!
device for shaping the end of a ductile pipe or tube to increase its diameter to a shape
suited for a flare fitting.
flash chamber
in a refrigerating system, a separating tan$ placed between the expansion device and
evaporator to separate and bypass any flash gas formed due to pressure reduction.
flashing
flash vapori0ation.
flash intercooler
vessel located between compression stages where in"ected liquid refrigerant vapori0es
immediately.
flash point
1. lowest temperature to which a product must be heated for its vapors to ignite in the
presence of a flame when operating under standardi0ed conditions. Compare fire
point.
2. in a vacuum cooling chamber, that pressure corresponding to the vapor pressure at
the product temperature and below which water vapori0ing commences.
#. in a piping suction, the pressure below which the liquid will flash into vapor.
flash vapori0ation instantaneous vapori0ation!
partial or total vapori0ation obtained by sudden reduction of pressure.
floating action
continuous action in which the input variable determines the rate of change of the
output variable; e.g., in the case of a controller, of the system deviation change.
floating floor
composite flooring system which exhibits a high sound transmission loss value,
consisting of a BfloatingD flooring surface supported from a structural floor through the
use of a series of vibration isolation pads.
floc$ point
temperature observed at the start of the formation of wax or other solid; determined by a
standardi0ed test to assess the low2temperature compatibility of certain petroleum
products with refrigerants.
floor rac$ airflow floor!
type of floor used in vehicles or cold rooms; allows air circulation beneath the load of
ware.
flotation
method of treating material by floating in a liquid; an ice2ma$ing method in which ice
floats away from the surface on which it has been fro0en.
flow
continuous motion of a fluid in pipes, ducts, channels, or through openings. &ee also
bac$flow.
annular flow
form of two2phase flow in a pipe where the gas forms the core and the liquid flows
annularly against the internal walls of the pipe.
balanced flow
airflow where the supply volume equals the exhaust volume.
boundary2layer flow
flow of that portion of a viscous fluid in the area of a body in contact with the fluid, and
in motion relative to the fluid.
counterflow
in heat exchange between two fluids, the opposite direction of flow; i.e., the coldest
portion of one fluid meeting the coldest portion of the other.
dispersed flow
form of two2phase flow, where the overriding gaseous phase entrains dispersed large
liquid drops.
emulsion flow bubble flow!
form of two2phase flow where the liquid carries finely dispersed bubbles of gas.
laminar flow streamline!
fluid flow in which all the particles move in substantially parallel paths.
molecular flow
gaseous flow where the average free path of the gas molecules is greater than the
largest dimension of the cross section of the duct.
parallel flow
see heat exchanger parallel flow!.
plug flow piston flow!
1. form of two2phase flow in which plugs of gas and liquid flow alternately in the pipe.
2. flow regime where the flow is predominantly in one direction and any contaminants
are swept along with the flow.
#. flow of solids suspended in liquid, characteri0ed by slippage of the cylindrical mass
and equal velocity in cross section.
pulsating flow
fluid flow phenomenon characteri0ed by periodic or pseudoperiodic! variation in
velocity.
separated flow
phenomenon that occurs when a fluid flowing along a wall separates itself from the
wall, caused by a change in wall orientation such as a relatively short radius of
curvature. 9ote: &eparated flow occurs particularly at the edges of the blades of a
turbomachine.
stonewall flow cho$ing flow!
state at which gas flow through a pipe or a centrifugal compressor reaches conditions
that significantly impede flow.
slug flow
plug flow.
stratified flow
form of low velocity two2phase flow in hori0ontal pipes, so that the free surface of the
liquid remains level between a gaseous and liquid phase above and below it,
respectively.
superfluid flow
frictionless passage of helium <e II! through narrow channels or capillaries.
turbulent flow eddy flow!
fluid flow in which the velocity varies in magnitude and direction in an irregular manner
throughout the mass.
two2phase flow
simultaneous flow of two phases of a fluid, usually gas2liquid flows.
variable flow
throttling control of water during a cooling or heating process.
viscous flow
1. laminar flow or streamline flow.
2. type of gas flow in which the average free path of gas molecules is much smaller
than the smallest cross2sectional dimension of the pipe conveying the substance.
wavy flow
1. in hori0ontal pipes carrying two2phase liquid2vapor systems, the alternation of full
liquid and partially full liquid levels that progress as waves along the pipe.
2. separated flow of vapor and liquid in a conduit.
flow area
in a heat exchanger with a bundle of tubes, the section that is effectively traversed by
the external fluid. %his section often varies from one point to another of an exchanger.!
flow capacity of a filter!
refrigerant gas flow that a filter passes while maintaining a specified pressure drop
across the clean filter. %he flow capacity is expressed in lb.min g.s! flow at a specified
evaporator temperature and return gas temperature for the given refrigerant.
flow no00le
tube specially shaped to increase the discharge velocity of the fluid.
flow pattern
configuration of the direction and velocity of a flowing fluid.
flow velocity
velocity local or average! of a fluid in a pipe, duct, or canal, or from an orifice.
flue
1. passage through which flue gases pass from a combustion chamber to the outside
atmosphere.
2. conduit between the flue outlet of the furnace and the integral draft diverter, draft
hood, barometric draft regulator, vent terminal, or any other point of draft relief.
appliance flue
flue within an appliance.
chimney flue
chimney for conveying the flue gases to the outside atmosphere.
dilution flue
flue designed to effect the dilution of flue gases with air before discharge from an
appliance.
flue collar
that portion of an appliance designed for attachment of a chimney, vent connector, or a
draft hood.
flue gas collector
chamber designed to capture the products of combustion and accompanying excess
air.
flue gas receptor location
any point e.g., an openable window, an occupied terrace! at which a person in a
nearby building can become exposed to flue gases emanating from a chimney.
1eceptor locations include inta$es of air2conditioning and ventilating systems.
flue gas vent
conduit or passageway for conveying flue gases to the outer air.
flue outlet
opening provided in an appliance for the release of flue gases.
fluid
substance, as a liquid or gas, that is capable of flowing, and which changes shape when
acted on by a force.
wor$ing fluid
medium evolving within a thermodynamic cycle.
fluidics
science and technology of using the properties of flow of fluids, to perform functions of
sensing, amplifying, and control in nonelectric circuits, and without the use of any
mechanical moving parts.
fluid mechanics
mechanics of flowing deforming! fluids, involving changes in momentum, direction of
flow, turbulence, pressure, and volume.
fluorocarbon
any of a broad group of organic compounds analogous to hydrocarbons, in which all or
most of the hydrogen atoms of the hydrocarbon have been replaced by fluorine; some
types also contain chlorine, and these are called chlorofluorocarbons. %he saturated
aliphatic2type fluorocarbons comprise the series of refrigerants developed by Aidgeley
in the 1*#,s. Compare halocarbon.
flux
amount of some quantity flowing across a given area often a unit area perpendicular to
the flow! per unit time. 9ote: %he quantity may be, for example, mass or volume of a
fluid, electromagnetic energy, or number of particles. &ee also magnetic flux; heat flux.
bra0ing flux
substance or mixture that promotes fusion and prevents formation of or eliminates
oxides, nitrides, or other undesirable inclusions in the bra0ing area.
soldering flux
chemical substance that aids the flow of solder and serves to remove and prevent
formation of oxides on the pieces to be "oined.
flywheel
heavy wheel attached to a shaft to reduce rotation fluctuations.
foaming
formation of a foam or froth of oil refrigerant due to rapid boiling out of the refrigerant
dissolved in the oil when the pressure is suddenly reduced. &ee also boiler foaming.
forecooler
in an ice plant, a device for cooling water before pouring into ice2ma$ing cans;
precooler.
fractionation
separation of a liquid mixture into parts by the preferential evaporation of the more
volatile component.
free water
in organic tissues, that part of water which can be easily removed, because it is not held
by adsorptive forces.
free0ant
medium, usually a liquid cooled by the evaporator of a refrigerating system, used to
free0e products.
free0e concentration cryoconcentration!
concentrating a solution by partial free0ing of water and removing ice crystals.
free0e desalination
free0ing saline or brac$ish water, so that salt2free ice crystals are formed, then removed
and melted.
free0e dryer
apparatus or system for drying substances by dehydration in a fro0en state.
drum free0e dryer
apparatus having a rotating cylinder in which a product is free0e dried.
free0e drying lyophili0ation!
dehydration of a substance by free0ing, and subsequent sublimation of ice.
atmospheric free0e drying
process in which the solid phase of the solvent is sublimed at atmospheric pressure.
centrifugal free0e drying
process in which a liquid product is vacuum fro0en while being centrifuged in order to
avoid foaming.
continuous free0e drying
process in which the product is continuously moved through the drying chamber.
secondary drying
in free0e drying, the removal of most of the solvent retained in the product after
primary drying.
spray free0e drying
free0e drying process during which a liquid product is spray fro0en prior to sublimation
of the ice.
free0e drying additive
substance added to a product to be free0e dried in order to facilitate recovery of the
fro0en mass.
free0e out
to separate the constituents of a mixture by free0ing one of them.
free0er
1. in cold storage, an insulated room $ept below #,)6 R1)C!.
2. device for free0ing perishables. &ee free0ing room.
blast free0er
chamber in which cold air is circulated rapidly around products to be fro0en so that
free0ing occurs rapidly enough to avoid formation of large ice crystals that may
damage the product.
carrying free0er
cold storage free0e room, generally $ept between R2, and 2,)6 R2* and R/)C! to
receive and hold fro0en goods.
chest free0er
free0er in which access is gained by raising a lid.
contact free0er
free0er in which the product is fro0en by contact with a refrigerated surface.
double2contact free0er
contact free0er in which the product to be fro0en is placed between two refrigerated
surfaces and ma$es contact with both.
fluidi0ed bed free0er
trough having a perforated bottom through which an upward flow of cold air suspends
the produce, usually of small unit si0e, and causes it to flow li$e a fluid.
household free0er
cabinet designed for extended storage of fro0en food at a recommended temperature
of ,)6 R1+)C!, with inherent capability for free0ing of food and a source of
refrigeration; intended for household !se%
multiplate free0er
double contact free0er consisting of a series of parallel refrigerated metal plates.
plate free0er
contact free0er in which the refrigerated surface is a flat metal plate. Compare doublecontact
free0er.
scraped surface free0er
apparatus in which a liquid free0es on the surface of a cooled drum to form a thin layer
which is removed by a scraper.
sharp free0er
cold storage free0er room, generally $ept at R#, to R1,)6 R#' to R2#)C!, to receive
unfro0en goods and free0e them.
spray free0er
insulated enclosure in which refrigerated liquid is sprayed over the product to be
fro0en.
tunnel free0er free0ing tunnel; blast2free0e tunnel!
elongated enclosure provided with rapid cold air circulation for the free0ing of
foodstuffs.
upright free0er
free0er in which access is gained through a side2opening door.
wal$2in free0er
free0er chamber large enough to wal$ in.
free0er burn
damage to fro0en produce caused essentially by excessive desiccation. Compare cold
in"ury.
free0er capacity
amount of produce that can be installed at one operation.
free0e2thaw resistance
property of a material which permits it to be alternately fro0en and thawed through many
cycles without damage.
free0e2up
1. failure of a refrigerating unit to operate normal2ly due to formation of ice at the
expansion device.
2. frost formation that impedes airflow through a coil.
free0e2up control
1. control device that prevents failure of a refrigeration system due to formation of ice at
the expansion device or in a coil such that it impedes airflow.
continued on next page!
2. thermostatic device that senses the approach of an icing condition and ma$es
compensating ad"ustments.
free0ing
process of changing a liquid substance or the liquid content of a food or other
commodity to a solid state by removing heat.
bul$ free0ing
free0ing of unpac$aged products.
contact free0ing
free0ing of produce by direct contact with a refrigerated surface.
crust free0ing shell free0ing!
very quic$ free0ing of the outer part of a product mainly poultry!, final free0ing being
completed by conventional methods.
food gla0ing
free0ing a coat of ice on fro0en foods by dipping the product in water, with the latent
heat absorbed inward.
individual quic$2free0ing I36!
free0ing of food units of small si0e e.g., peas, shrimp! individually separated.
"et free0ing
quic$ free0ing process using cold air at very high speed forced onto the produce. 4lso
called blast free0ing.
quic$2free0ing deep2free0ing!
free0ing of a food or other commodity at a rapid rate of temperature reduction to
produce a desired crystalline structure in the fro0en product.
refrigerated plate free0ing
heat removal by direct contact of the pac$aged product with refrigerated plates.
shell free0ing
free0ing of a liquid in thin layers on the walls of rotating bottles.
slow free0ing
free0ing of produce without attempting to reduce the temperature rapidly below that of
the 0one of maximum crystalli0ation.
soil free0ing
1. in public wor$s, free0ing the moisture in unstable water2bearing soils, in order to
facilitate digging mine shafts, tunnels, or foundations.
2. accidentally occurring under the floors of cold rooms frost heave!.
spray free0ing
free0ing of produce by spraying with a refrigerated liquid.
still air free0ing
free0ing of produce in a room without mechanical movement of air.
tray free0ing
free0ing food arranged on shallow trays which are placed on portable rac$s and put in
an insulated chamber through which cold air is blown.
vacuum free0ing
free0ing of a substance by lowering pressure to induce vapori0ation of a part of the
solvent usually water!.
free0ing capacity
mass of produce that can be fro0en per unit time by a particular free0er in specified
conditions of entry and final temperature.
free0ing mixture
mixture of salts with crushed ice to lower its melting point.
free0ing plant
installation, factory, etc. designed to free0e products, usually to prepare fro0en foods.
free0ing plateau thermal arrest!
during the free0ing of produce, that part of the graph of temperature against time, in
which the temperature remains virtually constant. It is induced by the time required to
remove latent heat.
free0ing2point depression
difference between the free0ing temperature of a pure solvent and that of a solution.
free0ing rate speed of free0ing!
ratio between the distance from the mean surface of a food mass to its thermal center
and the time elapsed between the surface reaching #2)6 ,)C! and the thermal center
reaching 1')6 R1,)C!.
free0ing room
cold chamber usually $ept at temperature of R22 to R#1)6 R#, to R#()C!, with high
volume air circulation. &ee free0er.
free0ing section
in a food processing plant, that section where foods are fro0en.
free0ing time
time for any complete free0ing process to ta$e place.
effective free0ing
time required from a given initial temperature, to free0e a product and to lower its
temperature at the thermal center to a given value.
nominal free0ing
time for a given product of specified dimensions and at an initial uniform temperature
of #2)6 ,)C!, the time it ta$es for the thermal center to reach 1')6 R1,)C!.
frequency
number of cycles per second through which an alternating electric current passes; in
9orth 4merica, generally standardi0ed at -, cycles per second -, <0!.
frequency response of a fan!
normali0ed motion response of a fan to a $nown excitation, expressed as a function of
the frequency of the excitation. %he frequency response usually is given graphically by
curves showing the relationship of the response to the excitation and, where
applicable, phase shift or phase angle! as a function of frequency.
freshness index
sensory index usually a * point scale! of sub"ective assessment of the purity of air by
occupants.
frictional resistance
resistance of fluid flow due to friction between the fluid and the contact surface over
which it flows.
friction loss
pressure loss due to friction between a flowing fluid and its contact surface.
friction ring rubbing ring!
component, rotary or fixed, of a shaft seal with a precision2machined contact face of the
ring that provides the gastight seal.
frost
water from airborne droplets or vapor fro0en on a surface.
frostbac$
coating of frost on suction line and cran$case due to liquid refrigerant leaving an
evaporator and carried along the suction line into the compressor cran$case.
frostbite frost damage; free0ing in"ury!
in"ury to living beings or produce caused by formation of ice in tissues.
frost deposit
frost formed on the cold surface tubes, plates! of a cooling coil.
frosted
coated with frost.
frost formation
frost formed on any cold part of a refrigerating circuit.
frost heave
rising of the cold store floor due to the expansion of free0ing water in the supporting soil.
frost level indicator
pipe loop pro"ecting from a vessel showing approximately the liquid level by the frost
formation.
fro0en earth storage fro0en ground storage; fro0en soil storage!
underground storage of liquefied gas within a space with walls, floor, and roof consisting
of fro0en soil or roc$.
fro0en food cabinet
refrigerated cabinet for the short2term storage of fro0en foods.
fro0en food display case
refrigerated counter designed for displaying fro0en foods.
fro0en food loc$er
individual loc$able compartment in a collective multicompartment establishment for the
free0ing and storage of food.
fro0en food store
store that contains exclusively fro0en food storage rooms.
fro0en food storage room free0er room!
cold room designated to receive and store fro0en foods.
fro0en food weight factor
conversion factor of #( lb.ft# (-, $g.m#! for a net free0er space weight rating. Aany
commercially available pac$aged fro0en foods weigh less than #( lb.ft# (-, $g.m#!.
fuel
1. substance which is burnable to provide heat.
2. nuclear substance usable in system energy generation, usually electricity.
fossil fuel
organic material occurring in nature excluding wood, including but not limited to coal,
oil, and natural gas.
refuse2derived fuel 176!
refuse used as a combustion fuel source to provide heat in a district heating plant.
fuel input rate
rate at which fuel is supplied to an appliance. %he rate may be expressed in Itu per
hour, watts, or thousands of Itu per hour; in cubic feet per hour, litres per second, or
thousands of cubic feet per hour; in therms th! or de$atherms dth! per hour, or in
gallons per hour.
fume hood
fume collection device mounted over a closed table or shelf serving to conduct
unwanted gases away from the area enclosed.
compensating hood
hood capable of compensating for local high velocities and turbulence caused by sash
equipment placed within, or operator interference at the hood face, or traffic past the
hood face.
fume hood face
plane of minimum area at the front portion of a laboratory fume hood through which air
enters when the sash is fully opened, usually in the same plane as the sash when
present.
fume hood performance rating
series of numbers and letters indicating the specific performance characteristics.
fume hood specified rating hood performance rating as specified, proposed, or
guaranteed in either the purchase of the hood, in the design and construction of the
laboratory, or both.
fume hood system
arrangement consisting of a fume hood, its ad"acent room environment, and the
equipment, such as blowers and ductwor$, required to ma$e the hood operable.
fumes
very small airborne particles, usually less than one micrometre in si0e, from burning or
melting materials.
fumigation
in the food industry, exposure of a product to gaseous substances, generally to $ill
insects, their eggs, and larvae.
functional performance
rating full range of chec$s and tests carried out to determine if all components,
subsystems, systems, and interfaces between systems function in accordance with the
contract documents. In this context, BfunctionD includes all modes and sequences of
control operation, all interloc$s and conditional control responses, and all specified
responses to abnormal and emergency conditions.
fungicide
substance capable of $illing parasitic fungi.
furnace
1. part of a boiler or warm air heating system in which energy is converted to heat.
2. enclosed chamber or structure in which heat is produced, as by burning fuel, or by
converting electrical energy.
attic2type central furnace
one designed specifically for installation in an attic or in a space with low headroom,
normally unoccupied.
condensing furnace
one that circulates the products of combustion and extracts available heat to a point
that causes condensation to occur. &ome of this latent heat of condensation is
recovered as usable energy, resulting in higher operating efficiency.
downflow2type central furnace
one designed with airflow essentially in a vertical path, discharging air at or near the
bottom of the furnace.
7utch oven furnace
extended furnace with a refractory cover, generally shaped to reradiate heat bac$ onto
the burning fuel.
forced warm air furnace
central furnace equipped with a blower which provides the primary means for
circulation of air.
hori0ontal2type central furnace
one designed with airflow through the furnace essentially in a hori0ontal path.
upflow2type central furnace
one designed with airflow essentially in a vertical path, discharging air at or near the
top of furnace.
warm air furnace
self2contained, direct2fired, or electrically heated furnace designed to supply heated
air through ducts to spaces that require it.
furnace firebox
combustion chamber in a furnace.
furnace sto$er
device that automatically feeds solid fuel to a furnace used mainly with coal!.
furnace volume
space enclosed by the chamber floor, the refractory walls, the heat2absorbing water
walls of a boiler firebox, and the crown sheet, shell, or water tubes of a boiler. If a target
wall bridgewall! is installed in the furnace, the furnace volume is reduced by the volume
behind the bridgewall.
fusible plug
safety device for release of pressure by melting a contained substance with a
predetermined melting temperature.
fusion
change of phase from solid to liquid.
gage gauge!
1. instrument for measuring pressure, flow, level, or other factor.
2. arbitrary scale of measurement for sheet metal thic$ness and wire and drill
diameters.
bourdon gage
mechanical pressure measuring instrument that senses pressure with a curved oval
tube that tends to straighten when the pressure increase and recurves when the
pressure decreases.
compound gage
pressure gage that indicates pressures above and below atmospheric pressure.
discharge gage high2pressure gage; head pressure gage!
gage fitted to the high2pressure side of a refrigerating system.
ioni0ation vacuum gage
gage operated via the ioni0ation of a gas, measuring the ionic current.
oil pressure gage
gage fitted to the delivery side of an oil pump.
pressure gage
instrument for measuring pressure above or below atmospheric pressure.
service pressure gage
pressure gage temporarily used during the installation and servicing of a refrigerating
system.
suction gage low2pressure gage; bac$2pressure gage!
gage fitted to the low2pressure side of a refrigerating system.
thermal conductivity vacuum gage
vacuum gage consisting of two surfaces at different temperatures between which heat
is transported by gas molecules in vacuum techniques!.
vacuum gage
gage for measuring pressures below atmospheric pressure.
gage glass
device for showing liquid level.
gas
state of matter in which substances exist in the form of nonaggregated molecules, and
which, within acceptable limits of accuracy, satisfy the ideal gas laws; usually a highly
superheated vapor. &ee state.
flash gas
portion of the liquid refrigerant which is vapori0ed by sudden reduction of pressure.
flue gas vent gas!
all gases in a flue during combustion in the combustion chamber, including reaction
products such as excess air, carbon dioxide, carbon monoxide, oxygen, water vapor,
nitrogen, and other inerts.
hot gas
refrigerant gas in the high2pressure side of the system.
ideal gas perfect gas!
gas whose internal energy and enthalpy depend solely on temperature and which is
defined by pv 5 1%.
incondensible gases
gases, other than water vapor, found in steam and produced at the boiler; containing
oxygen and carbon dioxide as causes of corrosion in steam and condensate systems.
inert gas
gas that neither experiences nor causes chemical reaction nor undergoes a change of
state in a system or process, e.g., nitrogen or helium mixed with a volatile refrigerant.
liquefied petroleum gas C>M!
mixed hydrocarbon gases stored under pressure in liquid form.
natural gas
naturally occurring mixture of hydrocarbon and nonhydrocarbon gases found in
porous geologic formations beneath the earthPs surface, often in association with
petroleum. %he principal constituent is methane.
noncondensable gas foul gas!
gas in a refrigerating system that does not condense at the temperature and partial
pressure at which it exists in the condenser, therefore imposing a higher head
pressure on the system.
storage gas
in controlled atmosphere storage, a gas or atmosphere with carbon dioxide added.
gas2air mixture
lean mixture
gas2air mixture of which the air content is more than adequate for complete
combustion, and the resultant combustion gases will contain an excess of oxygen.
rich mixture
gas2air mixture of which the air content is not sufficient for complete combustion, and
the resultant combustion gases will contain burnable but unburned hydrocarbons.
gas binding rate
gas ebullition rate that flushes liquid out of the evaporator, creating a pressure that
prevents infeed, resulting in drying of the evaporator surface.
gas capacity I2>!
concept of power throughput, in Itu.h, at 12inch water column pressure drop for the gas
being used.
gas demand rate
rate at which gas is delivered to or by a system, part of a system, or a piece of
equipment, expressed in cubic feet cubic metres or litres! or therms AL! or multiples
thereof, for a designated period called the demand interval. Compare gas load.
gas enrichment
increasing the heat content of a gas by mixing with it a gas of higher heat content.
gaseous state see state; gas; phase.
gas load
amount of gas delivered or required at any specified point or points on a system; load
originates primarily at the gas2consuming equipment of customers.
generating capability electric!
maximum load that a generating unit, generating station, or other electrical apparatus
can carry under specified conditions for a given period, without exceeding approved
limits of temperature and stress ratings.
gland
device for preventing lea$age at a machine "oint, such as where a shaft emerges from a
vessel containing a fluid under pressure.
gravity current
stream of incoming fluid that moves hori0ontally immediately ad"acent to the upper or
lower boundaries of a stagnant body of fluid. %he stream moves due to density
differences between the fluid in the stream and that in the stagnant body of fluid.
&ee also 6roude number.
grille
louvered or perforated covering for an opening in an air passage, which can be located
in a sidewall, ceiling, or floor.
ground coupling
in a thermal storage system or a heat pump, a closed loop of piping, plastic tubing, or
ducting used as a heat exchanger between the ground, acting as a low2grade heat
source, and a circulating fluid.
ground fault
unintentional electrical connection to ground. electrical ground 0ero voltage, or any
point electrically connected to the earth, or ground.
guide vane assembly
assembly of ad"ustable guide vanes fitted to the inlet of a fan or turbocompressor. Its
function is to modify the flow and the pressure.flow rate.
pre2rotary vane assembly
in a turbocompressor, an assembly of ad"ustable guide vanes fitted to the inlet; its
function is to orient the fluid so that the pressure.flow rate characteristics can be
modified.
pre2rotation vane pre2rotary vane!
guide vane in the pre2rotary vane assembly of a turbo2compressor.
halide torch
device to detect gas lea$s using the color changes of a flame in the presence of a
halogenated hydrocarbon.
halocarbon
compound containing carbon, one or more halogens, and sometimes hydrogen.
Compare fluorocarbon.
halogen
one of the electronegative elements of Mroup EII 4 of the periodic table of the elements
fluorine, chlorine, bromine, iodine, and astatine!; listed in the order of their chemical
activity, fluorine being the most active of all chemical elements.
hardening quenching!
1. rapid cooling from specific temperatures of metallic products, particularly steel, in
order to increase hardness.
2. cooling the product from the ice cream free0er in order to free0e most of the water not
solidified in the free0er.
hard2wired
1. in electronic circuits connected with wires.
2. method of programming a system to perform specified functions through the use of
wires often patchboard styles, or, more recently, read2only memory techniques! as
opposed to a stored program or software method.
<artford loop
condensate return arrangement for low2pressure steam2heating systems, featuring a
constant waterline in the boiler.
<C6C
halocarbon that contains fluorine, chlorine, carbon, and hydrogen.
head
1. energy per unit mass of fluid divided by gravitational acceleration.
2. in fluid statics and dynamics, a vertical linear measure. 9ote: %he terms head and
pressure are often mista$enly used interchangeably. &ee also suction head.
friction head
height of liquid that represents system resistance caused by the flow. 9ot an &I term.!
pressure head
hydrostatic height of fluid, equal to the fluid pressure divided by the density times the
gravitational acceleration.
static head
hydrostatic height of a fluid.
total head
sum of static head, pressure head, and velocity head.
velocity head
height of fluid corresponding to the $inetic energy per unit mass of fluid divided by
gravitational acceleration.
head loss dynamic head loss!
during flow, the reduction in the velocity head.
header
1. pipe or tube extruded, cast, or fabricated! to which a number of other pipes or tubes
are connected.
2. removable end cover.
steam header
1. hori0ontal piping connected to a boiler steam outlet or outlets.
2. in a location out of a boiler room, where a steam main extends into several
branches located close together.
heat
1. energy that is transferred in the direction of lower temperature.
continued on next page!
2. form of energy which is exchanged between a system and its environment or
between parts of the system induced by temperature difference existing between
them.
fermentation heat
heat evolved during a fermentation process.
heat of fusion fusion heat!
1. latent heat involved in changing between the solid and the liquid states.
2. heat energy required to cause a change of state from solid to liquid at constant
temperature. 6or ice2to2water: 1'#.( Itu.lb ###.+ $L.$g!.
humid heat
ratio of increase of enthalpy per unit mass of air, with its associated moisture, to the
rise of temperature under conditions of constant pressure and specific humidity.
latent heat
change of enthalpy during a change of state.
latent heat of condensation
quantity of heat released on change of unit mass of vapor to liquid with no change in
temperature.
latent heat of vapori0ation
heat energy required to cause a change of state from a saturated liquid to a saturated
vapor, measured in Itu.lb mass L.$g!.
mechanical equivalent of heat
in &I, one "oule of heat equals one "oule of mechanical wor$.
metabolic heat
heat produced by oxidation of food elements i.e., metabolism! in humans or animals.
%he met represents the average heat produced by a sedentary man: approximately *,
$cal.h or 1,, K #', Itu.h!.
radiant heat
heat transferred by radiation.
recoverable heat
portion of thermal input to a prime mover that is not converted to mechanical power
and can be reclaimed.
respiratory heat
in plants, heat evolved during the respiratory process absorption of oxygen and
evolution of CF2!.
sensible heat
heat which causes a change in temperature.
specific heat
ratio of the quantity of heat required to raise the temperature of a given mass of any
substance one degree to the quantity required to raise the temperature of an equal
mass of a standard substance one degree ?usually water at (*)6 1()C!@.
total heat
enthalpy.
waste heat
unused heat re"ected from a system, usually a heat engine or combustion furnace, to
its surroundings.
heat anticipation
ability of a thermostat to terminate heat input at a temperature lower than its setting, and
in advance of the time that the rising air temperature at the thermostat normally would
cause the thermostat to terminate heating.
heat balance
statement that shows the changes in a system from heat and wor$ input to output
losses.
heat bridge heat channel; heat lea$!
part of the boundary construction of an insulated enclosure through which heat can flow
readily by conduction.
heat capacity
amount of heat necessary to raise the temperature of a given mass one degree;
numerically, the mass multiplied by the specific heat.
heated slab
concrete slab2on2ground floor, heated by integral wires, cables, pipes, or ducts, that
radiates heat to a conditioned space.
heat equivalent of wor$
heat energy corresponding to a unit of mechanical energy. &ee heat, mechanical
equivalent of.
heater
apparatus or appliance to supply heat to a space or a fluid. &ee also water heater.
blast heater
set of heat transfer coils or sections used to heat air which is drawn or forced through
them by a fan. 4 unit heater.
direct2fired heater
fuel burning device in which the heat from combustion and the products of combustion
are transferred directly to the space to be heated.
electric heating element
unit assembly of a resistor, insulated supports, and terminals for connecting the
resistor to electric power.
indirect2fired heater
one in which combustion products do not come into contact with the material to be
heated; heating of the material is accomplished by radiation or conduction from the
heated surface.
integrated heater
boiler operated in con"unction with an indirect2fired storage water heater or an external
storage tan$ in which domestic water, heated by the boiler, is stored.
noncontaminating heater
one used with a heavy oil burner that avoids contamination of the water supply to the
heater.
unit heater
heater consisting of a fan for circulating air over a heat2exchange surface, all enclosed
in a common casing.
water heater
low2pressure, hot water boiler having a volume not exceeding 12, gallons '(, C!, or
a heat input not exceeding 2,,,,,, Itu.h -, $K!, or an operating temperature not
exceeding 2(,)6 12,)C!, to provide hot water to a system.
heater cable heater tape; heater strip!
electrical heating element usually fitted to cold room doors to prevent icing.
heater mat
electrically heated wire mesh or heated liquid networ$ embedded in a cold store floor to
prevent free0ing of water, which may be in the soil below.
heat exchange
process of heat transfer in which heat flows from one substance to another.
heat exchange surface
surface area of any heat exchanger available for transmitting heat.
extended heat exchange surface augmented surface!
increased area for heat flow by means of fins, dis$s, etc.
heat exchanger heat interchanger!
device to transfer heat between two physically separated fluids.
air2to2air heat exchanger
exchanger that transfers heat from an exhaust airstream to a separated supply
airstream. 9ote: 6ixed plate, rotary wheels, heat pipes, runaround coil loops, and
shell2and2tube are the most common types.
counterflow heat exchanger
heat exchanger in which fluids flow in opposite directions approximately parallel to
each other; inlets for the two fluids are at opposite ends of the exchanger.
crossflow heat exchanger
heat exchanger in which fluids flow perpendicular to each other.
direct contact heat exchanger
apparatus in which the fluids exchanging heat are brought into contact with each
other.
double pipe heat exchanger
two pipes arranged concentrically, one within the other, and in which one fluid flows
through the inner pipe and the other through the annulus between them.
double wall heat exchanger
two fluids separated by two walls with the space between open to the atmosphere so
that a fracture on one wall will not transfer one fluid into the other. 8sed in water
systems with a potable fluid and a potentially ha0ardous fluid.
heat pipe heat exchanger
tubular closed chamber containing a volatile fluid in which heating one end of the pipe
causes the liquid to vapori0e and transfer to the other end where it condenses and
dissipates its heat. %he liquid that forms flows bac$ toward the hot end by gravity or by
means of a capillary wic$.
indirect heat exchanger water heater!
heat exchanger ta$ing heat from steam or water rather than heat directly.
liquid or suction heat exchanger
superheater.
multichannel heat exchanger
apparatus in which fluids exchange heat by flowing in an assembly of separated
channels.
multitubular heat exchanger multipipe heat exchanger!
heat exchanger consisting of an assembly of tubes which convey one of the heat
exchange fluids.
parallel flow heat exchanger
heat exchanger in which fluids flow approximately parallel to each other and in the
same direction.
plate heat exchanger
fixed plates that separate and $eep the hot and cold fluids separate. &ee also cooler
plate liquid cooler!.
rotary heat exchanger
apparatus in which the heat exchange surface rotates.
runaround heat exchanger
finned tube coils closed system! or spray chambers open systems! in which a liquid
is circulated by gravity or pump action through a heat source exchanger and then
through a heat sin$ exchanger. 4ntifree0e may be used in the coil loop, and a
desiccant in the spray system.
scraped heat exchanger
exchanger having a surface on which a fluid can be solidified and the solid layer
scraped off.
shell2and2tube heat exchanger
nest of tubes or pipes, or a coil of tube or pipe, contained in a shell or container. %he
pipes! carries a fluid through it, while the shell is also provided with an inlet and outlet
for flow of another fluid.
heat exchanger casing
structure which encloses the heat exchanger and forms a passage around it for the fluid
being heated.
heat exchanger face area
in a heat exchanger, with a bundle of tubes, the section that is effectively traversed by
the external fluid "ust before it passes through the tube bundle. %he area measured is
the lesser area of the two heat exchanger surfaces.
heat exchanger heating surface
area intended for transferring heat.
extended surface
assembly consisting of fins, pins, or ribs that receives heat by conduction from the
prime surface; an extension normally of the side of the fluid with the lower coefficient
of heat transfer. &ee also heat transfer surface.
primary surface direct surface!
1. surface that is in direct contact with both the heat2absorbing and heat2emitting
media.
2. portion that is exposed to radiation from the fire and transfers heat directly to the air
being heated.
prime surface
surface having the heating medium on one side and fluid or extended surface! on the
other.
secondary heating surface
portion of the heat exchanger not exposed to direct radiation from the fire that
transfers heat by direct convection from the combustion products to the air to be
heated. %he area of the outer casing, inner lining, or any radiation shields are not
considered heating surfaces.
secondary surface indirect surface!
in extended surface exchangers, the additional surface that is not in direct contact with
both the heat absorbing and heat2emitting media.
heat exchanger removable head removable end cover!
in shell2and2tube heat exchangers, a head which can be unbolted for cleaning or
maintenance.
heat exchanger system
assembly factory2 or field2assembled! of components necessary to comprise a
complete heat exchanger system.
energy recovery system
heat exchanger assembly for transferring heat between two isolated airstreams;
incorporating an exhaust air blower, auxiliary heaters or coolers, auxiliary dampers
inta$e, exhaust, face and bypass, and recirculating!, controls operating and safety!,
and other custom2designed features.
heat recovery ventilator <1E!
factory2assembled unit for transferring heat between two isolated airstreams;
incorporating exhaust and fresh air fans, auxiliary components necessary for
operation dampers and heaters!, and controls safety and operating!.
heat exchanger tube plate tube sheet!
plate located at the ends! of a multitubular shell2and2tube heat exchanger, into which
the tubes are fixed.
heat flow
passage of heat from one point to another or one space to another by one or more of
the three modes, conduction, convection, and radiation. &ee also thermal
transmittance.
transient heat flow
heat flow induced by a temporary temperature difference.
heat flow meter
apparatus designed to measure the heat flow from or into a surface.
heat flow path
in a variable temperature field, the lines of heat flow.
heat flow rate
quantity of thermal energy flowing in unit time.
heat flux density of heat flow rate!
heat flow rate from a surface per unit area.
heat gain heat upta$e!
quantity of heat absorbed by an enclosed space or system.
solar heat gain sun effect!
solar energy flowing into a building, through both windows and structural materials.
heating
process of adding heat energy causing a rise in temperature, or a transfer of sensible
heat into latent heat. &ee also district heating; heating system.
electric space heating
permanently installed electric heating as the principal source of space heating
throughout an entire dwelling or business establishment.
regenerative heating
heat re"ected in one part of a system used to perform a useful function in another part.
thermodynamic reverse cycle! heating
heating by use of a heat pump.
heating coil
coil supplied with either heated liquid or vapor, designed to heat fluids air, gas, or
liquids!.
heating stac$ loss
sensible heat carried away by the flue gas, and the sensible and latent heat carried
away by the water vapor in the flue gas.
heating system
one in which heat is transferred from a source of energy through a distribution net2wor$
to spaces to be heated see hot water heating system.
central heating plant
1. one serving all or most of the rooms in a building, as distinguished from individual
room heaters.
2. one serving two or more buildings, also termed district heating.
direct heating system
heating, air2conditioning, or refrigerating system in which electric heating elements or
products of combustion, or the refrigerant, exchange heat directly with the material or
space to be heated, or with the air in a passageway communicating with such space.
direct return heating system
two2pipe system in which the heating medium is returned from the terminal exchange
unit to the boiler.
down2feed heating system
piping arrangement for heating, air2conditioning, or refrigerating systems, in which
heating and cooling fluid is circulated through supply mains which are above the
levels of the heating or cooling units they serve.
dry return heating system
steam heating in which a return pipe carries both condensate and air. %he return pipe
is always above the waterline in the boiler in a gravity system.
dual heating system
heating system utili0ing two fuel or energy sources, such as gas, oil, coal, or electric
power, either as alternate sources or with one as a booster to the other.
dump trap liquid return heating system
method of separation and automatic return of liquid refrigerant from an accumulator in
the low side to the high side of the plant.
heat2of2light system
system in which heat due to lighting intensity is utili0ed for heating spaces in a
building.
hot water heating system hydronic heating system; wet heating system!
heating system for a building use in which the heat2conveying medium is hot water
and the heat emitters are radiators, convectors, or panel coils.
indirect heating system
one in which a fluid, such as air, is circulated to the material or space to be heated, or
is used to heat air so circulated.
one2pipe steam system
system in which the condensable vapor from the supply main passes into a heating
unit and returns as condensate through the same supply main.
radiant comfort heating
system in which temperatures of room surfaces are ad"usted in order to control the
rate of heat loss by radiation from sub"ects within that room.
reverse return heating system
heating system in which the hot water return piping from terminal units is si0ed to
provide equal lengths for balanced flow rates.
series perimeter loop heating system
hot water heating system in which each radiator is connected in series with the next,
and all flow returns to the boiler in the loop.
wet heating system see hot water heatin' system
wet return heating system
steam heating system in which a return pipe carries condensate. %he pipe usually is
located below the level of the waterline in the boiler, although not necessarily so.
heating system performance factor <&>6!
total heating output of a heat pump during its normal period for heating, in Itu, divided
by the total electric energy input during the same period, in watt2hours. 6or &I use,
compare coefficient of performance.
heating value
amount of heat produced by the complete combustion of a unit quantity of fuel. %he
gross or higher heating value is that obtained when all the products of combustion are
cooled to the temperature existing before combustion, the water vapor formed during
combustion is condensed, and all the necessary corrections have been made. %he net
or lower heating value is obtained by subtracting the latent heat of vapori0ation of the
water vapor formed by the combustion of the hydrogen in the fuel, from the gross or
higher heating value.
heat lag thermal lag!
time elapsing between the initiation of a thermal phenomenon and the appearance of its
effect.
heat losses
1. infiltration losses! energy required to warm outdoor air lea$ing in through crac$s and
crevices around doors and windows, or through open doors and windows, and
through porous building materials.
2. transmission losses! heat transferred through confining walls, glass, ceiling, floor, or
other surfaces.
heat loss rate thermal storage!
rate at which heat is lost from a storage device per degree temperature difference
between the average storage medium temperature and the ambient temperature or
ground temperature, if the storage device is buried!.
heat of reaction
heat per unit mass or per mole! of reagents and substances in a chemical reaction;
exothermal if heat is given off, endothermal if absorbed.
heat of subcooling
quantity of heat removed from a liquid to reduce it from its saturation temperature at
saturation pressure, to some lower temperature at the same pressure.
heat of the liquid
enthalpy of a mass of liquid above an arbitrary 0ero.
heat output
heat input less heat loss; when electricity is the energy source, output is the same as
input.
heat pump
thermodynamic heating.refrigerating system to transfer heat. %he condenser and
evaporator may change roles to transfer heat in either direction. Iy receiving the flow of
air or other fluid, a heat pump is used to cool or heat.
cooling and heating heat pump
system designed to alternately or simultaneously use heat extracted at a low
temperature and heat re"ected at a higher temperature for cooling and heating
functions, respectively.
heating heat pump
refrigerating system designed primarily to use re"ected heat for desired heating.
thermoelectric heat pump
one based on the >eltier effect.
heat pump balance point
temperature at which the heat pump capacity and the building heat requirement are
equal.
heat pump heating effect
see compressor heating effect.
heat rate
measure of generating station thermal efficiency, generally expressed in Itu per net
$ilowatt2hour. Computed by dividing total energy content of fuel burned for electric
generation by the resulting net $ilowatt2hour generation.
heat recovery
use of heat that would otherwise be wasted from a heating system.
heat recovery ventilator <1E!
factory2assembled unit that incorporates a means to circulate air for ventilation and
provision to transfer heat between two isolated airstreams.
heat reservoir
system that can absorb or re"ect heat from storage.
heat sin$ cold source!
substance or environment into which unwanted heat is directed.
heat source
substance or environment from which heat is ta$en.
low2grade heat source
heat source at a temperature too low to be efficiently used by an exchanger for the
heating intended, but which may be used through the intermediary of a heat pump.
heat transfer heat transmission; heat transport; thermal transmission!
flow of heat energy induced by a temperature difference.
heat transfer fluid
fluid used in a heat transfer process.
heat transfer medium
material used within rotary heat exchangers, also referred to as matrix or heating
medium; a fluid, such as water, steam, air, or flue gas to convey heat from a boiler,
furnace, or other heat source, and deliver it, directly or through a suitable heating
device, to a substance or space to be heated.
heat transfer surface
outside area of a heat exchanger through which heat flows. &ee fin.
extended surface augmented surface!
increase in area of a heat transfer surface by addition of fins, dis$s, or other means;
used on the side of the heat2transfer surface which has the lowest coefficient of
surface film transmission.
heat transmission
1. time rate of heat flow; usually refers to conduction, convection, and radiation
combined.
2. in thermodynamics, a general term sometimes used for heat travel; but, since most
applications have continuity of time, heat flow is the more appropriate term.
#. general term for the process by which incident flux leaves a surface or medium on a
side other than the incident side.
heat trap
energy conserving arrangement of the hot water piping leaving the water heater
constructed to counteract the convective forces of the heated water thermosiphoning!
during standby periods.
heat treatment
heating and cooling a metal or alloy to obtain desired properties or conditions.
heat value heating value; heat of combustion!
amount of heat released in the oxidation of one mole of a substance at constant
pressure, or constant volume.
helium
inert, noncombustible gaseous element of atomic number 2, that liquefies at '.2 H to
form helium I. <elium II is formed on cooling helium I below its transition point. It has the
property of Bsuperfluidity,D i.e., exhibiting extremely high thermal conductivity, and
viscosity approaching 0ero.
<6C
halocarbon that contains only fluorine, carbon, and hydrogen.
higher heating value <<E!
amount of heat produced per unit of fuel when complete combustion ta$es place at
constant pressure, and the products of combustion are cooled to the initial temperature
of the fuel and air, and when the vapor formed during combustion is condensed. %he
higher heating value is expressed in Itu.lb or Itu.ft# K.m#! for gaseous fuel, or Itu.lb
AL.$g! or Itu.gal for liquid fuel.
<ilsch21anque effect
spot cooling effect produced in a tube into which gas is introduced tangentially
producing vortex flow.
<ilsch21anque tube pulse tube!
device in which the <ilsch21anque effect is produced.
hipot test
electrical insulation test, which consists of the application of a high voltage between a
circuit and its frame.
hoarfrost
deposit of ice crystals, produced in a manner similar to dew but at a temperature below
#2)6 ,)C!.
home run wiring
wiring from the device all the way to the distribution panel. %his wiring is usually run in
the most direct paths but with standard wiring practices and does not contain any
splices, branches, or devices.
horsepower
unit of power in the I2> system; wor$ done at the rate of ((, ft O lb.s /'(./ K!. &ee also
bra$e horsepower.
hot dec$
hot air chamber forming part of an air handler.
hot gas bypass regulator
automatic valve operated by the suction pressure which it maintains above a given
value by diverting a certain quantity of high side vapor to the low side of the system.
hot2gas line
1. line used to convey discharge gas from the compressor to the condenser.
2. line used to convey discharge gas from the compressor to the evaporator for the
purpose of defrosting.
humidifier
device to add moisture to air or gases.
central humidifier
device that humidifies air to be circulated through ducts in an air2conditioning system.
direct in"ection humidifier
device that in"ects boiler steam into airflow through ducting.
room spray humidifier
air humidifier which sprays atomi0ed water directly into the room.
self generating humidifier
unit producing steam at or about atmospheric pressure for in"ection, either directly into
the air through a room fan unit, or directly into ducting through an in"ection manifold.
spinning dis$ humidifier
apparatus using centrifugal action to atomi0e and distribute moisture into an
airstream.
humidify
to add water vapor or moisture to any moisture2absorbing material, including the
atmosphere.
humidifying effect
product of the mass of water evaporated times the latent heat at the evaporating
temperature.
humidity
absolute humidity vapor concentration; water2vapor density number!
in a mixture of water vapor and dry air, the mass of water vapor in a specific volume of
the mixture. Compare relative humidity.
relative humidity
1. ratio of the partial pressure or density of water vapor to the saturation pressure or
density, respectively, at the same dry2bulb temperature, and barometric pressure of
the ambient air.
2. ratio of the mole fraction of water vapor to the mole fraction of water vapor
saturated at the same temperature and barometric pressure.
specific humidity
ratio of the mass of water to the total mass of a moist air sample.
humidity controller
device sensitive to relative humidity variations used for system regulation.
humidity percentage
ratio in percent of the mass of moisture at a given temperature to the maximum possible
at the same temperature. &ee relative humidity.
humidity ratio mixing ratio!
ratio of the mass of water vapor to the mass of dry air.
humidity saturation ratio
ratio of the specific humidity to that at saturation at the same temperature and pressure,
usually expressed as a percentage.
hunting in a control system!
condition that occurs when a controller, controlled device and system, individually or
collectively, continuously overrides and undershoots or overshoots the control point,
with resulting fluctuation and loss of control of the condition to be maintained. &ee
cycling.
hydraulic diameter
four times the flow area divided by the perimeter of the solid boundary in contact with
the fluid.
hydraulic lift
in a pumping system, the static height head! to be overcome by the pump.
hydraulic shoc$
internal pressure stress imposed in piping systems by a sudden change in liquid
velocity, as by the sudden stopping of flow.
hydrocooling
cooling of produce generally vegetables or fruit! by direct contact with chilled water.
hydrolysis
alteration of a chemical substance by water.
hydrometeor
any product of condensation or sublimation of atmospheric water vapor, whether
formed in the free atmosphere or at the earthPs surface. =xamples are rain, snow, sleet,
and hail.
hydrometer
instrument that indicates the density of a liquid by the depth of its submergence while it
is floating.
hydronics
science of heating and cooling water.
hydrostat
device for controlling the level of a liquid in a reservoir.
hydrostatic loc$up
potential internal pressure stress in piping or vessels due to temperature rise in liquids
such as refrigerants, water, or secondary coolants, when the containment volume is
completely filled with liquid.
hygrometer
instrument responsive to relative humidity, usually relative humidity in the atmosphere.
Compare psychrometer.
absorption hygrometer chemical hygrometer!
1. instrument in which the relative humidity is determined from the absorption of water
vapor by a hygroscopic material.
2. chemicals impregnated into small paper cards that change color with specific
relative humidities.
dew2point hygrometer
device that measures the temperature at which water droplets "ust appear on a cooled
polished surface.
electrical hygrometer
one whose sensitive element has electrical properties that vary with humidity.
electrolytic hygrometer
one that indicates relative humidity from the electrical resistance of a hygroscopic salt.
organic hygrometer
instrument that indicates relative humidity by variations in shape or length of units of
organic matter.
hygroscopic
capable of absorbing and retaining.losing moisture.
hypothermia
severe chilling of the human body; may be used for limited periods in certain surgical
cases.
hysteresis
in control systems, the difference between the response of a system to increasing and
decreasing signals.
ice
fro0en water; the solid phase of <2F.
briquette ice
ice produced as small regularly shaped and si0ed pieces.
chip ice chipped ice!
ice in thin fla$es.
clear ice crystal ice!
bloc$ ice obtained by agitating the water during free0ing, and subsequently removing
by suction the core of unfro0en water where impurities are concentrated.
crushed ice
small, irregularly shaped pieces of ice produced by crushing bloc$ ice or plate ice.
cube ice
ice manufactured in small cubes or regular pieces.
dynamic ice
ice formed on a cooling surface, then removed to be stored in an insulated container
tan$!. Compare ice harvester.
eutectic ice
fro0en eutectic mixture used as cold accumulation.
fragmented ice
ice manufactured on refrigerated surfaces and harvested by hot gas and mechanical
choppers.
plate ice
ice manufactured in thic$ sheets or harvested in winter from la$es or rivers.
ribbon ice
ice produced in the form of long, thin ribbons obsolete!.
rime ice
granular deposit of opaque ice on a surface, formed by quic$2free0ing of supercooled
water droplets.
seawater ice
ice made by free0ing seawater.
shell ice
ice manufactured on external surfaces of vertical refrigerated tubes and harvested by
hot gas.
slice ice scale ice; fla$e ice!
ice produced by free0ing a thin layer of water on a refrigerated cylinder and removing
by a scraper.
slush ice
small pieces of wet ice, usually wet snow ice or wet fla$e ice.
static ice
ice formed in containers or on pipe coils.
white ice
opaque ice in which air or salts present in the raw water are trapped.
ice builder
refrigerated coils immersed in a tan$ of water used for forming ice, and to provide ice
water. Compare thermal storage device.
ice core suc$ing2and2filling system
combination of a pump, distributing piping, hose, and device by which impure water
may be withdrawn from the unfro0en core of an ice bloc$, and, connecting the source of
water supply, the core may be refilled with pure water.
ice cream
sweet fro0en food containing cream, or one of various substitutes, and flavoring.
ice cream free0er
apparatus for partially free0ing an ice2cream mixture.
ice cream hardening process
refrigerating process in which ice2cream mixture is hardened immediately after partial
free0ing.
ice harvester
machine that manufactures ice on a cooling surface, then delivers it to storage.
ice ma$er
automatic ice2ma$ing machine in which ice is formed, harvested, and stored.
cyclic ice ma$er
automatic ice ma$er with separate and sequential water fill, free0ing, and harvesting
phases of the ice2ma$ing operation.
noncyclic ice ma$er
continuous ice ma$er with simultaneous water supply, free0ing, and harvesting
phases in the ice2ma$ing operation.
ice ma$ing capacity
actual productive mass output of an ice2ma$ing plant in a given time.
ice ma$ing temperature
temperature range in which most free0ing ta$es place, i.e., about 2( to #,)6
R' to R1)C! for water. 4lso called 0one of maximum crystal formation.
ice ma$ing water forecooler
1. device for cooling water before it is fed into the ice cans.
2. ice2melting equivalent heat absorbed by ice at #2)6 ,)C! in liquefying to water at
#2)6 ,)C!. 6or precise data, 1'#.( Itu.lb. ##'.' $L.$g!; for definition of ton,
1'' Itu.lb.
ice point melting point!
1. equilibrium temperature of ice and water usually at standard atmospheric pressure!.
2. temperature at which water free0es under normal atmospheric pressure 1'.-*- psig,
#2)6 1,1.#2( $>a, ,)C!.
ice regelation
1. refree0ing phenomenon; for ice, after removal of pressure induced by contacting
materials, such as ice s$ates, wheels, wires, and bars.
2. refree0ing of the water film that forms on or within ice when the pressure from applied
material is sufficient to reduce the free0ing point to below the ice temperature at that
location.
ice slurry liquid ice!
suspension of ice crystals in a secondary coolant.
ice storage system
thermal storage system, used for chilling processes or for comfort cooling, that uses the
phase change of ice to water. Ice is formed during periods of low refrigerating demand,
for delivery of cooling during periods of high refrigerating demand.
ice surfacing
treatment to smooth the ice surface.
ice tray
container for free0ing water into ice.
ice water
1. melted ice.
2. water chilled, as with ice.
ignition
initiation of combustion. 9ote: Combustion may be evidenced by glow, flame,
detonation, or explosion. %he combustion may be sustained or transient.
illuminance
luminous photometric! irradiance.
impedance
total restriction resistance and reactance! that an electrical circuit presents to the flow
of an alternating current; specifically the ratio of voltage to current and the phase angle
between them.
input impedance
impedance in an electrical circuit or networ$ as seen from outside at input terminals.
load impedance
1. impedance that an electrical load imposes on a circuit.
2. impedance that an electrical load should by design impose on a circuit.
nonlinear impedance
1. impedance that varies with applied voltage.
2. impedance that cannot be represented by a first2order mathematical equation.
impeller rotor; wheel!
rotating part of a device fan, blower, compressor, or pump! that moves fluid. &ee also
fan.
bac$ward2curved impeller
centrifugal rotor in which the convex sides of blades face in the direction of rotation.
forward2curved impeller
centrifugal rotor in which the concave sides of blades face in the direction of rotation.
radial2bladed impeller paddle2bladed impeller!
one in which the blades are flat and disposed radially from the fan hub to the outer
edge.
unshrouded impeller open impeller!
impeller with the blades left uncovered.
impeller bac$plate impeller hub dis$; impeller hub plate!
dis$ rotating with the axle, to which the impeller blades of a centrifugal fan are fixed.
impeller reaction
ratio of the variation of the fluid pressure in the impeller to the total variation of pressure
in the device.
impeller running noise frequency
in a turbomachine, the noise frequency resulting from the rotational speed of the
impeller.
inch of water inch water gage; inch water column!
in the I2> system, a unit of head equal to a column of liquid water 1 inch high at #*.2)6.
indicated horsepower
horsepower absorbed as measured by means of an indicator diagram.
indicated wor$
wor$ absorbed as measured by an indicator diagram, independent of time.
indicator diagram indicator card!
pressure2volume diagram tracing a gas in a compressor or engine cycle in terms of
pressure and volume displaced. &ee also volumetric efficiency.
indicator diagram reexpansion line
curve on an indicator card representing the pressure; the total volume relationship of
clearance fluid during the initial portion of the return stro$e of the piston prior to the
opening of the suction valve.
indoor air quality I43!
attributes of the respirable atmosphere climate! inside a building including gaseous
composition, humidity, temperature, and contaminants. &ee also freshness index.
acceptable indoor air quality
air in which there are no $nown contaminants at harmful concentrations, as determined
by cogni0ant authorities, and with which a substantial ma"ority +,G or more! of the
people exposed do not express dissatisfaction. &ee also sic$ building.
induction entrainment!
entrainment of room air by the "et action of a primary airstream.
induction unit
air terminal device that delivers a small quantity of conditioned primary! air through
high2velocity "ets, to induce a large quantity of room secondary! air into the supply
airstream. 4 heating coil may be located in the primary or secondary airstream. >rimary
air often is predominately outside air. 8nits generally discharge directly through a grille
into the space due to limited downstream static pressure capability.
high2pressure induction unit
one that uses no00les which produce high2velocity "ets; the high2velocity "et of primary
air induces a flow of secondary air through coils located in the secondary airstream.
low2pressure induction unit
one using a "et of conditioned air or primary air! to induce into the unit a flow of room
or secondary air which mixes with the primary air. %he mixture is discharged into the
room through a grill at the top of the unit. <eating coils are located in the secondary
airstream for use in heating.
room air induction unit
one consisting of a cooling coil or cooling and heating coil! and means for delivery of
preconditioned air received under pressure from an external source mixed with
recirculated air by air induction process to the space being conditioned. %his device is
normally designed for free delivery of air into rooms.
inductive load
alternating current load in which current lags voltage.
infrared CF2 meter
instrument for estimation of carbon dioxide content, based on absorption of infrared
radiation.
infrared detector
device that transduces the infrared irradiance incident on it into some other form of
energy, in most cases electrical.
infrared imaging system
apparatus which converts the two2dimensional spatial variations in infrared radiance
from any ob"ect surface into a two2dimensional thermal map of the same scene in which
variations in radiance are displayed in gradations of gray tone.
infrared noise
equivalent temperature difference measure of the electric! noise of an infrared imaging
system or line scanner; the target2to2bac$ground temperature difference between a low
spatial frequency blac$body target and its blac$2body bac$ground at which a ratio of
one is obtained between the pea$2to2pea$ signal and 1A& noise at the output of the
detector processing electronics of the sensor in question.
infrared panning
infrared surveying procedure in which an infrared device is moved bac$ and forth
across a sub"ect surface thereby permitting thermal anomalies to be identified.
infrared I1! radiation
range of electromagnetic radiation wavelengths greater than those of visible light and
shorter than those of microwaves; generally between ,.+ micrometre and 1 millimetre.
I1 originates from either incandescent or nonincandescent hot bodies or from flames.
%he energy is used as a means of direct heat transfer from the source to the ob"ects!,
to be heated without materially heating the intervening air.
infrared thermal! resolution
measure of the capability of an infrared sensing device to distinguish the apparent
radiance temperature difference between two blac$bodies near the same temperature.
limiting resolution
highest spatial frequency of an ob"ect space target which an imaging sensor is able to
resolve. %he spatial frequency of the target is determined by ta$ing the inverse of the
ratio of two bar widths divided by the distance from sensor to target. %his number
generally is multiplied by 1,,, and expressed in cycles per milliradian.
ob"ect plane resolution
si0e in the ob"ect plane which corresponds to the products of the systemPs
instantaneous field of view in radians and the distance from the system to the ob"ect.
spatial resolution
planar angle defined by the instrument instantaneous field of view, i.e., the resolution
element.
infrared scanner
infrared detector mounted on a motor2driven platform which causes it to scan a field of
view line2by2line, much as in television.
imaging line scanner
apparatus which scans in a single dimension and is moved perpendicular to the scan
direction to produce a two2dimensional thermal map of the scene. &ee also infrared
survey.
line scanner
apparatus which scans along a single line of a scene to provide a thermal mapping of
a discrete width or slice of the scene.
infrared sensing device
wide class of instruments used to display and.or record information which is
proportional to or equivalent to the thermal radiation from any ob"ect surfaces viewed by
the instrument. %he instrumentation varies from simple spot radiometers, which
measure only one spot or area, to two2dimensional thermal imagers, which provide
photographic quality pictures and which map the scene radiosity.
infrared survey airborne!
generation of thermograms of building structures as viewed from overhead using an
imaging line scanner.
imaging exterior survey
generation of thermograms of outside surfaces of a building.
imaging interior survey
generation of thermograms of portions of a building as viewed from the building
interior.
nonimaging survey
generation of a set of apparent temperature measurements of building surfaces
usually the interior! obtained with a nonimaging thermal sensing device.
inherent regulation
property of a system to reach a steady state after a disturbance without the intervention
of a control equipment.
in"ector
1. device for forcing water into a boiler against the pressure of the boiler by means of a
steam "et.
2. device for lifting or pumping one fluid by using another, higher pressure fluid to create
a partial vacuum. &ee also e"ector.
input2output device
equipment that introduces data into or receives data from a data communications
system.
input rating
fuel2burning capacity of an appliance in Itu.h K!, as specified by the manufacturer.
4ppliance input ratings are based on sea level operation, and need not be changed for
operation up to 2,,, feet -,, metres! altitude.
instruction
statement that specifies an operation and the values or locations of all operands. In this
context, the term BinstructionD is preferable to the terms BcommandD or Border,D which are
sometimes used as synonyms. Command should be reserved for electronic signals.
Frder should be reserved for sequence, interpolation, and related use. Ioth command
and order have important military applications.
logical instruction
instruction that carries out a logical operation, such as 497, F1, 9F1.
microinstruction
small single, short, add, shift, or delete type of command.
instruction repertoire
1. part of an instruction cycle during which the control or data2processing system is
capable of performing.
2. set of instructions which an automatic coding system assembles.
instruction time
1. portion of an instruction cycle during which the control unit is analy0ing the instruction
and setting up to perform the indicated operation.
2. same as execution time.
instrument sensitivity
measure of the smallest incremental change to which an instrument can respond.
insulated door
door built with materials that resist heat flow, often designed for service in cold or
free0er rooms, or for service in high2temperature rooms, or for specified fire resistance.
insulating cement
mixture of dry granular, fla$y, fibrous, or powdery materials that when mixed with water
and applied to a surface forms a coherent thermal insulating covering after drying.
insulating mastic
premixed soft material that possesses some thermal resistance, applied by spray,
trowel, brush, or by hand.
insulation
see electrical insulation, sound insulation, thermal insulation.
integral draft diverter heating appliances!
device that is an integral part of an appliance designed 1! to provide exhaust of the
products of combustion in the event of no draft, bac$ draft, or stoppage beyond the draft
diverter; 2! to prevent a bac$ draft from entering the unit; and #! to counteract the
effect of stac$ action of the chimney or gas vent on the operation of the unit.
integrating sphere
optical device used either to collect flux reflected or transmitted from a sample into a
hemisphere, or to provide isotropic irradiation of a sample from a complete hemisphere.
It consists of a cavity that is spherical in shape, with apertures for admitting and
detecting flux, and usually having additional apertures over which sample and reference
specimens are placed.
intelligent building
building in which direct digital control systems are employed to control mechanical,
electrical, and elevator systems; fire and smo$e systems; and security systems for a
complete, integrated building automation and display, for operation and maintenance.
intercooler interstage cooler!
apparatus for cooling compressed gas or vapor between two compression stages.
intercooling
removal of heat from compressed gas between compression stages.
interface
connection between a computer and some other device that either transmits information
to or receives information from the computer.
interpretation of a standard!
written explanation of the meaning of specific provisions, as determined by the issuing
body in response to an inquiry.
interrupt device
device to disconnect a load from a power source, or distribution center under an
overload or short circuit condition; e.g., a fuse, disconnect switch, etc. %his interrupt is
not an integral part of the operating equipment.
external interrupt device
1. one not an integral part of the operating equipment, such as a fuse or disconnect
switch.
2. one generated by an alarm point that causes an alarm. &ee also switch.
interruptible load electric!
1. commercial and industrial! those loads that by contract can be interrupted by the
supply system in the event of a capacity deficiency in the supplying system.
2. load management! those loads that by user agreement can be interrupted in the
event of a capacity deficiency in the supply, transmission, or distribution systems, or
for load deferral.
interruptible rate electric!
price rate normally covering reduced pricing for a supply of electricity that can be
interrupted at the utilityPs option, either instantaneously as required or with advance
notice.
interstitial space
space between two 0ones, rooms, or floors of a building.
intrinsic barrier electric!
component or circuit that limits the energy available in a ha0ardous location to a level
that is incapable of igniting the ha0ardous atmosphere.
ioni0ing radiation treatment
atomic particles and rays applied to foods to destroy microorganisms. Compare
irradiation.
I2> units inch2pound units!
units using inches, pounds, and other designations; as opposed to &I units in the metric
system. =xamples are: foot, Itu, horsepower, gallon.
irradiance
radiant flux density. &ee also solar irradiance.
irradiance at a point of a surface!
quotient of the flux incident on an element of a surface containing the point, by the area
of that element, measured in watts per square metre.
bac$ground irradiance
irradiance at the entrance aperture of the infrared sensing system that is not radiated
directly from the ob"ect being investigated.
direct normal beam! irradiance
irradiance received from the sun without significant change of direction from the
apparent position of the sun. &ee also pyrheliometer.
diffuse s$y! irradiance
solar radiation that has been scattered in passing through the earthPs atmosphere. It is
equal to the global irradiance less the direct normal and ground2reflected components.
global hemispherical! irradiance
quantity of solar energy incident on a unit surface area in unit time through a unit
hemisphere above the surface, expressed in Itu.hO ft2 K.m2!.
instantaneous irradiance
quantity of solar radiation incident on a unit surface area in unit time, measured in
Itu.hO ft2 K.m2!.
integrated average irradiance
quantity of solar radiation incident on a unit surface area during a specified time
divided by the duration of that time period.
spectral irradiance
density of the radiant flux incident on a surface per unit of wavelength K.m2Onm!.
total irradiance
quantity of radiant energy incident upon a surface over all wavelengths.
irradiation
1. sub"ecting foods, etc., to radiations of special wavelengths, such as the ,.2(#/
micrometre wavelength, which $ills certain bacteria.
2. quantity of radiant energy incident on a surface of unit area in unit time.
isenthalp
thermodynamic change at constant enthalpy. &ee expansion isenthalpic!.
isentrope
line of equal or constant entropy.
isentropic process reversible adiabatic!
thermodynamic change at constant entropy.
isochor
graph that shows the variation of one quantity with another; for example, the variation of
pressure with temperature, when the volume of the substance is held constant.
isobar
1. line graph of state representing an isobaric process.
2. line at one barometric pressure.
isobaric isopiestic!
thermodynamic change at constant pressure.
isochome
thermodynamic change at constant volume.
isolated combustion system
installation in which a unit is installed indoors but all combustion and ventilating air is
admitted through grilles or ducts from outdoors and all such air does not communicate
with air in the conditioned space.
isomer
one of a group of substances with the same ultimate chemical composition but different
molecular structure.
isopsychric
state of constant relative humidity.
isotherm
graph of a state line that represents one temperature.
isothermal
process at constant temperature.
isotope
one of two or more atoms with the same number of protons, but different numbers of
neutrons in their nuclei. Isotopes have very nearly the same chemical properties, but
often different physical properties.
iterative procedure
process which repeatedly executes a series of operations until some prescribed
condition is satisfied.
"ac$et
1. sealed space around a piece of equipment or a storage unit, through which a thermal
medium can be circulated.
2. integral covering, sometimes fabric reinforced, which is applied over insulation, or the
core, shield, or armor of a cable to provide mechanical or environmental protection.
water cooled "ac$et
hollow casing around the cylinder head and.or walls of a compressor, through which
cooling water is passed.
"oint
area at which two ends, surfaces, or edges are attached.
bra0ed "oint high2temperature!
gastight "oint obtained by "oining metal parts with alloys that melt at temperatures
higher than 1(,,)6 +,,)C!, but at less than the melting temperatures of the "oined
parts.
bra0ed "oint low2temperature!
gastight "oint obtained by the "oining of metal parts with metallic mixtures or alloys that
melt at temperatures below 1(,,)6 +,,)C!, but above 1,,,)6 (',)C!.
butt "oint
"oint between two members lying approximately in the same plane.
compression "oint
multipiece "oint with cup2shaped threaded nuts which, when tightened compress
tapered sleeves so that they form a tight "oint on the periphery of the tubing that they
connect.
expansion "oint
device in a structure, a pipe run, etc., that can by linear compensation accept variation
of length from expansion or contraction due to temperature changes.
flanged "oint
one made by bolting together a pair of flanged ends.
flared "oint flare fitting!
metal2to2metal compression "oint in which a conical spread is made on the end of a
tube that is compressed by a flare nut against a mating flare.
mechanical "oint
general form for gastight "oints obtained by "oining metal parts through a positive
holding mechanical construction such as flanged "oint, screwed "oint, flared "oint!.
>ittsburgh loc$ "oint
longitudinal folded "oint used in rectangular sheet metal duct construction.
poc$et loc$ "oint
transverse "oint used in rectangular sheet metal duct construction.
slip "oint
method of constructing transverse seams in rectangular sheet metal ducts.
snaploc$ "oint
longitudinal folded "oint used for rectangular sheet metal duct construction in which
the seam is snapped together.
soldered "oint
gastight "oint obtained by "oining metal parts with metallic mixtures or alloys that melt
at approximate temperatures above ',,)6 2,,)C!, but not exceeding +,,)6 '#,)C!.
standing seam "oint
folded "oint used for transverse "oints in rectangular sheet metal duct construction and
for apparatus casing seams.
sweat "oint
type of fitting formed by a melted filler metal alloy flowing by capillary action between
the parts to be "oined.
swing "oint
arrangement of screwed fittings and pipe provided for expansion in pipelines.
welded "oint
gastight "oint obtained by "oining metal parts in the plastic or molten state.
"oint creep
tendency of a soldered "oint to part when sub"ected to tensile force.
"oint ring
gas$et in the form of a torus used for a seal between flanges or "oints.
$atharometer $atherometer!
instrument for measuring the CF2 concentration in a cold2storage atmosphere wor$ing
on the principle that CF2 has a thermal conductivity different from other gases.
Concentrations of other gases can also be measured using this principle.
$elvin day
&I unit of accumulated temperature departure; a degree2day in $elvin temperature units.
Compare degree2day.
laboratory fume hood
box2li$e structure enclosing a source of air contamination, with one open or partially
open side into which air is moved for the purpose of containing and exhausting air
contaminants and generally used for bench2scale laboratory operations, but not
necessarily involving the use of bench or table.
lea$age current
1. nonreversible constant electric current component of the measured current that
remains after the capacitive current and absorption current have disappeared. 9ote:
Cea$age current passes through the insulation volume, through any defects in the
insulation, and across the insulation surface of solid or liquid insulation.
2. current that flows when a semiconductor device is in the off or bloc$ed state usually
in the nanoampere range!.
leased line computer!
transmission path rented from a common carrier for purposes of interconnecting data
modems. Frdinarily, a voice2grade channel path for data transmission.
leased line networ$
total leased line conductors between all interconnected data modems in a data
transmitting system.
interexchange leased line networ$
leased line networ$ with data modems connected at multiple locations through central
offices. 8sually synonymous with intercity or interstate.
intraexchange leased line networ$
leased line networ$ with data modems connected at multiple locations through a
single common carrier central office, or offices in the case of a big city or a city with
suburbs. 8sually limited to shorter distances because of leasing charges.
single2premises leased line networ$
leased line networ$ on a single customer premises, either interbuilding or multiple
building, that does not run bac$ through the common carrier central office.
least squares
estimate in statistics and econometrics, the method of estimation that involves the
choice of an estimate such that the sum of the squares of the deviations of the data
from the estimate is a minimum.
life cycle cost
cost of equipment over its entire life, including operating and maintenance cost.
light emitting diode C=7!
low2current, low2voltage semiconductor light used as an indicator in electronic circuitry.
limit stop
physical stop or device that prevents an operator from ad"usting the set point of a
controller beyond a maximum or minimum setting, often for safety.
linear regression
finding of a straight line that best fits the data points, commonly by use of the leastsquares
technique.
linear swell
percentage increase in the length of a test specimen, usually an elastomer, as a result
of exposure to refrigerants or oils.
liner
enclosure forming the interior of the general refrigerated compartment or some free0er
compartments!. %he complete liner comprises the compartment liner in the cabinet, the
exposed brea$er strip surfaces, and the door liners!.
liquefaction
change of state to liquid; generally used instead of the term, condensation, in cases of
substances ordinarily gaseous.
liquid
state of matter intermediate between crystalline substances and gases in which the
volume of a substance, but not the shape, remains relatively constant.
compressed liquid
one in which the existing pressure is greater than the saturation pressure for the given
temperature.
saturated liquid
liquid existing at the saturation temperature and pressure.
supercooled liquid
one in which the existing temperature is lower than the saturation temperature for the
given pressure.
liquid cooler
heat exchanger designed to cool liquids.
liquid line
tube or pipe carrying the refrigerant liquid from the condenser or receiver of a
refrigerating system to a pressure2reducing device.
liquid poc$et liquid slug!
accidental trapping of liquid refrigerant at any point in the system.
liquid2vapor mixture
liquid and gaseous phases of a single substance or a0eotrope usually at saturation.
liquor
solution used in absorption refrigeration.
strong liquor rich liquor; strong solution!
solvent with a relatively high concentration of dissolved refrigerant.
wea$ liquor wea$ solution!
solvent with a relatively low concentration of dissolved refrigerant.
load
1. amount of heat per unit time imposed on a refrigeration system by the required rate of
heat removal.
2. energy absorbing device.
#. material, force, torque, energy, or power applied to or removed from a system or
element.
'. to put data into a register or storage. &ee also Iritish thermal unit Itu!; capacity; ton.
connected load
sum of all loads on an electrical circuit at a selected time.
cooling load
1. amount of cooling per unit time required by the conditioned space or product.
2. heat a cooling system must remove from a controlled system over time.
design load pea$ load!
pea$ instantaneous load that a system is expected to meet.
gross load
sum of the space heating or air2conditioning load, domestic hot water load, process
load, and the piping and pic$up load.
heating load
heating rate required to replace heat loss from the space being controlled.
latent heat load moisture tons; wet tons!
cooling load to remove latent heat.
loc$ed2rotor load rotating machinery!
electrical loads that exist when the circuits of a motor are energi0ed, but the rotor is
not able to turn.
pic$up load
actual load for heating the system following setbac$.
piping load
unusable heat loss or gain from piping.
refrigerating load
amount of heat per unit time imposed on a refrigerating system for the required rate of
heat removal.
refrigerating service load
quantity of heat to be removed from a refrigerated space to compensate for opening
doors, presence of personnel, heat from electric lights, etc.
resistive load
1. electric load without capacitance or inductance or one in which inductive portions
cancel capacitive portions at the operating frequency.
2. electric load with all energy input converted to heat and light.
sensible heat load
cooling load to remove the sensible heat. &ee also sensible heat ratio.
thermal load
thermal capacity of a system under specified conditions. &ee also capacity.
usage load
sum of the air change, product, and miscellaneous loads on a refrigerator; the sum of
the loads exclusive of wall, floor, or ceiling heat gains.
load management electric!
deliberate control or influencing of user loads to affect the time of use of electric power
and energy.
automatic2to2user load management
as a part of indirect load management, the automatic monitoring and control by a user
of loads to ta$e advantage of electric rate economic incentives.
direct load management
subfunction of power system distribution automation that controls interruptible user
loads or otherwise selected user appliances from one or more centrali0ed, utilityoperated
locations in chosen groups, load classes, and.or timed patterns.
Characteri0ed by remote control by the serving utility of user interruptible loads.
4lso called active load management.
indirect load management
subfunction of power system distribution automation that implements economic
incentives to induce user action, including automation provided by the user.
Characteri0ed by user local control of loads in response to economic incentives
applied. 4lso called passive load management.
system load management
subfunction of equipment hardware! and programming software! that implements
direct and.or indirect load management, coordinated with other functions of energy
management in an electric utility system.
loading error
1. error due to the adverse effect of a load on the transducer or signal source driving it.
2. error in transferring data from a data source to a computer memory. &ee also error.
load profile
summary of thermal loads in a system over time. 9ote: e.g., 4 common load profile on a
pea$ design day, for thermal storage designs would show hourly system load
requirements for 2' hours.
loc$ed rotor current C14; loc$ed rotor amperage!
steady2state current ta$en from the line with the rotor loc$ed and with rated voltage and
rated frequency in the case of alternating2current motors! applied to the motor.
loc$er plant
cold2storage loc$er.
logic
1. science of dealing with the criteria or formal principles of reasoning and thought.
2. systematic scheme which defines the interactions of signals in the design of an
automatic data2processing system.
#. basic principles and application of truth tables and interconnection between logical
elements required for arithmetic computation in an automatic data2processing
system.
logical decision
choice or ability to choose between alternatives. %his amounts to an answer yes or no
to a question of equality or relative magnitude.
logical flowchart
detailed statement of the wor$ order in terms of logic, or built2in operations and
characteristics, of a specified machine. Concise symbolic notation is used to represent
the information and describe the input, output, arithmetic, and logical operations by use
of a standard set of bloc$ symbols. 4 coding process normally follows a logical
flowchart.
loop
1. sequence of instructions that is repeated until a terminal condition prevails.
2. communications circuit between two private subscribers or between a subscriber and
a local switching center.
#. electric circuit containing a complete, continuous path as in a feedbac$ loop.
loss2of2charge protector
1. device which is capable of discerning the loss of refrigerant charge in a refrigerating
machine and of reacting to protect the apparatus from motor burnout.
2. splitting of a dry condensate line to permit vapors to pass above and condensate to
pass below an obstruction.
loss of head
pressure loss expressed by the height of a column of the fluid.
louver
1. assembly of sloping vanes intended to permit air to pass through and to inhibit
transfer of water droplets; outdoors, to shed rain.
2. device comprising multiple blades which, when mounted in an opening, permits the
flow of air but inhibits entrance of other elements in a reverse direction.
ad"ustable louver
louver in which the blades may be operated manually or by mechanical means.
fixed louver
louver in which the blades do not move.
low pressure side low side!
1. portion of a refrigerating system operating at approximately the evaporator pressure.
2. suction side.
low pressure stage
compression stage from a low to an intermediate pressure level.
low temperature
generally, a temperature below free0ing. &ee temperature.
low water cutoff
in a boiler system, a device to automatically cut off the fuel supply when the surface of
the water falls to the lowest safe waterline.
lubrication
reducing friction between bearing surfaces in relative motion by a low2friction fluid film,
or other means.
forced lubrication pump lubrication; mechanical lubrication;
forced2feed oiling!
lubricating system with the oil fed under pressure by a pump.
splash lubrication
lubricating system for a compressor with the oil in the cran$case fed to all moving
parts and to cylinder walls by the splashing action of a dip or paddle integral or
attached to the cran$shaft ends of the connecting rod.
machine room
1. engine room, a room in which mechanical equipment is permanently installed and
operated.
2. main computer room.
magnetic flux
lines of force that exist about a magneti0ed body and collectively constitute a magnetic
field.
magnetic flux density
degree of concentration of magnetic lines of force.
maintainability
specific period within which a system or facility can operate in an economical, fully
restored condition.
maintenance maintenance program!
maintenance concept in terms of time and resource allocation. It documents the
ob"ectives and establishes the criteria for evaluation and commits the maintenance
department to basic areas of performance such as prompt response to mechanical
failure, maintenance, and attention to planned functions that protect the capital
investment and minimi0e downtime or failure response.
corrective maintenance
classification of expended or reserved resources used to predict and correct
impending failure. Corrective action is strictly remedial and always performed before
failure occurs.
planned maintenance
classification of maintenance department resources that are invested in prudently
selected functions at specified intervals. 4ll functions and resources attributed to this
classification must be planned, budgeted, and scheduled. It embodies two concepts:
preventive and corrective maintenance.
predictive maintenance
function of corrective maintenance. &tatistically supported ob"ective "udgment is
implied. 9ondestructive testing, chemical analysis, vibration and noise monitoring, as
well as visual inspection and logging are all classified under this function, providing
that the item tested or inspected is part of the planned maintenance program.
preventive maintenance
classification of resources allotted to ensure proper operation of a system or
equipment under the maintenance program. 7urability, reliability, efficiency, and safety
are the principal ob"ectives.
management information function
provision of information useful for management of a building environment, and.or its
energy efficiency and.or <E4C system maintenance.
manifold
portion of a main in which several branches are close together. 4lso, a single piece in
which there are several fluid paths.
water manifold
water connection wherein one pipe communicates with several other lateral outlets
through a common housing or fitting.
manometer
instrument for measuring head or pressure; basically a 82tube partially filled with a
liquid, usually water, mercury, or light oil, so constructed that the difference in level of
the liquid legs indicates the pressure exerted on the instrument.
membrane manometer diaphragm manometer!
pressure gage with a flexible membrane whose deformations are used to indicate
pressure.
viscosity manometer
pressure gage which uses the variations of viscosity of a gas with pressure in
vacuum techniques!.
manufactured home
manufactured building intended to be used as a dwelling. 9ote: %he 8.&. 7epartment of
<ousing and 8rban 7evelopment <87! has adopted a legal definition, found in '2
8&C (',2.
mass transfer mass transport!
transfer of one component of a mixture, relative to the motion of the mixture. It is the
result of a concentration gradient. Compare heat transfer.
mean tan$ temperature
arithmetic mean of tan$ water temperatures determined, using multiple thermocouples
or other measuring devices.
meat $eeper
enclosed compartment or container which is designed for the storage of fresh meat at
or near #2)6 ,)C!.
mechanical properties
properties of a material that reveal the elastic and inelastic reaction when force is
applied, or that involve the relationship between stress and strain; for example, the
modulus of elasticity, tensile strength, and fatigue limit.
Aeissner state
thermodynamic state shown by all superconductors in a sufficiently wea$ magnetic
field, characteri0ed by the exclusion or expulsion of magnetic flux from everywhere
within the superconductor except a thin surface layer.
melting
change of state from solid to liquid caused by absorption of heat.
melting point
for a given pressure, the temperature at which the solid and liquid phases of the
substance are in equilibrium.
memory capacity
amount of data that can be contained in a memory storage device.
meniscus
1. free surface of a liquid which, near the walls of a vessel, is curved because of surface
tension.
2. in a manometer, the datum point measured at the center of the free surface.
met
unit of metabolic rate of people. Fne met is defined as 1+.' Itu.hO ft2 (+.1( K.m2!,
which is equal to the energy produced per unit surface area of a seated person at rest.
%he surface area of an average man is about 1* ft2 1.+ m2!.
metabolism
chemical changes in living cells by which energy is provided for vital processes.
meter
measuring device.
meter constant electric!
multiplier applied to the register reading to obtain $ilowatt2hours.
microclimate
conditions such as temperature, humidity, and motion of air within an enclosure or
limited outdoor area.
microwave thawing ultrahigh frequency thawing!
dielectric thawing, usually of fro0en food, heat being produced by microwave passage.
miscibility
ability of a liquid or gas to dissolve uniformly in another liquid or gas.
mixed state
thermodynamic state of certain superconductors in which an array of fluxons carries
magnetic flux through the superconductor.
mixing box blending box; mixing unit!
compartment into which two air supplies are mixed together before being discharged.
mixing section
in a duct system, a section for mixing airstreams at differing temperatures or humidities,
or both.
mnemonic
type of instructions for a computer written in a form which is easy for the programmer to
remember a memory "ogger! but which must later be converted into machine language.
modeling
representing of a process, device, or concept in mathematical simulation.
modem
acronym for modulator.demodulator. <ardware device used for changing digital
information to and from an analog form to allow transmission over voice2grade circuits.
mode of vibration
in a system undergoing vibration, the characteristic pattern of displacement assumed by
the system vibrating at one of its resonance frequencies.
modulate
1. to ad"ust by small increments and decrements.
2. to vary a voltage or other variable with a signal.
modulation of a control!
ad"ustment of controller action by increments and decrements.
modulus
constant or coefficient that expresses, usually numerically, the degree in which a
property is possessed by a substance or body.
bul$ modulus of elasticity
ratio of the compressive or tensile force applied to a material per unit surface area to
the change in volume of the material per unit volume. 4lso $nown as bul$ modulus,
compression modulus, or hydrostatic modulus.
modulus of elasticity ToungPs modulus!
ratio of stress nominal! to corresponding strain below the proportional elastic! limit
of a material, expressed in force per unit area based on the average initial crosssectional
area. 9ote: %he proportional limit is the greatest stress that a material is
capable of sustaining without any deviation from proportionality of stress to strain
<oo$ePs law!.
modulus of rupture in bending
maximum stress per unit area that a specimen can withstand without brea$ing when it
is bent, as calculated from the brea$ing load under the assumption that the specimen
is elastic until rupture ta$es place.
modulus of rupture in torsion
maximum stress per unit area that a specimen can withstand without brea$ing when
its ends are twisted, as calculated from the brea$ing load under the assumption that
the specimen is elastic until rupture ta$es place.
moisture
1. water vapor.
2. water in a medium such as soil or insulation; but not bul$ water or flowing water.
grain of moisture
convenient unit of measurement of water vapor. 1 grain 5 1./,,, pound avoirdupois
historically, the average weight of a grain of wheat!.
residual moisture
in a free0e2dried product, the ratio of the mass of residual water to the original mass of
product.
moisture carryover
retention and transport of water droplets in a gas stream usually air!.
moisture indicator
device indicating the moisture content of a substance.
moisture proofing damp proofing!
process for ma$ing things impervious to liquid. 9ote: If not completely impervious, use
moisture retarder.
mold
1. minute fungi growing on moist organic matter.
2. matrix or cavity in which anything is shaped or formed.
mole mol!
amo!nt of s!"stan$e of a system that $ontains as many e#ementary entities as there
are atoms in /%/12 5' of $ar"on 12 *i%e%( :%/23 ⋅ 1/23+% Note: 4hen the mo#e is !sed(
the e#ementary entities m!st "e spe$ified and may "e atoms( mo#e$!#es( ions(
e#e$trons( other parti$#es( or spe$ified 'ro!ps of s!$h parti$#es%
molecular diffusion
diffusion in a body at rest.
molecular sieve
adsorbent composed of porous aluminosilicates with pores of uniform molecular
dimensions that selectively adsorb molecules of the substance to be adsorbed.
molecule
group of atoms held together by chemical forces. %he smallest unit of a compound that
can exist by itself and retain all its chemical properties.
Aollier diagram Aollier chart!
graph of enthalpy versus entropy of a vapor on which isobars, isothermals, and lines of
equal dryness are plotted.
motor overload protection
devices that automatically disconnect a motor from its energy supply when
predetermined unsafe temperatures or overcurrent conditions exist.
inherent motor protection
1. device buried in the motor winding to detect the winding temperature and interrupt
the supply line when the allowable winding temperature is exceeded.
2. feature of electrical motor whereby protective devices are mounted integrally to the
motor.
line2brea$ motor protection
1. control device which automatically opens the line connections to a motor when a
predetermined unsafe temperature exists in the windings of the motor.
2. electrical motor protective action which causes the power line to the motor to be
interrupted on protective requirement.
overcurrent motor protection
1. overload devices, either eutectic alloy or bimetal, which protect a motor against an
overcurrent. 6uses and circuit brea$ers do not protect a motor, they only protect
branch wiring.
2. device used to interrupt the supply voltage to a motor when the allowable full2load
current is exceeded.
solid2state motor protection
1. solid2state switch used with a current sensor to interrupt the supply line to a motor
to provide motor protection.
2. protective device using electronic solid2state materials as opposed to conventional
electromechanical devices.
starting overload
1. motor2starting device equipped with overload trip mechanism for protection of the
motor.
2. starting a device with a load connected that will require the device to operate
outside its designed operating range.
temperature motor protection
inherent motor protection.
motor power engine!
machine in which power is applied to do wor$ by the conversion of various forms of
energy into mechanical force and motion.
multi0one
1. spatial divisions of a building having different air2conditioning loads.
2. air2conditioning unit capable of handling variable loads from different sections of a
building simultaneously.
nadir
1. point of the celestial sphere that is directly opposite the 0enith and vertically
downward from the observer.
2. ob"ect point that is directly beneath an aircraft flying an airborne imaging survey.
nameplate rating
full2load continuous rating of a generator, prime mover, or other equipment under
specified conditions, as designated by the manufacturer; and usually indicated on an
attached plate. Compare capacity.
natural air circulation
air circulation caused by differences of density induced by differences of temperature.
natural ventilation
movement of air into and out of a space through intentionally provided openings, such
as windows and doors; or through nonpowered ventilators; or by infiltration.
nebuli0e
to supply very fine water spray or steam into an airstream or enclosure.
net positive suction head 9>&<! available!
head at the pump inlet greater than the vapor pressure expressed as head! at the
operating temperature of the liquid being pumped.
neural networ$
computer circuits patterned after the complex interconnections among nerve cells in the
brain.
night cover
removable cover placed over an open2top refrigerated display case during overnight
periods in order to reduce energy transfer with the environment.
nitrogen capacity of a refrigerating capillary tube!
cfm C.s! equivalent to the mass flow rate of dry nitrogen which would be passed for a
specified inlet pressure if discharge had been to standard atmospheric conditions of
2*.*2 in. 1,1.#2( $>a! absolute pressure.
nitrogen purge
procedure in which nitrogen gas is bled into piping as it is welded, bra0ed, or soldered;
or after, to displace gases within the piping. %he nitrogen displaces the air from inside
the pipe, minimi0ing oxidation and resultant scale formation.
noise
sound, or a sound of any sort; especially sound without agreeable musical quality.
ambient noise bac$ground noise when equipment is not in operation.
electric noise
random electrical signals, introduced by circuit components, natural disturbances, or
other and unrelated circuits, which tend to degrade the performance of a control
system.
white noise
1. noise, either random or impulsive, having a flat frequency spectrum at the
frequency range of interest.
2. generated noise having the same noise per unit bandwidth anywhere in the
spectrum.
noise criteria curves 9C curves!
curves that define the limits which the octave2band spectrum of a noise source must not
exceed if a certain level of occupant acceptance is to be achieved.
noise reduction 91!
difference between the average sound pressure levels, or sound intensity levels, of two
spaces. 8sually those two spaces are two ad"acent rooms called, respectively, the
source room and the receiving room.
nomenclature
system of names identifying or classifying component items or constituent parts,
particularly in mathematics, science, and engineering.
nondestructive test 97%!
procedure that evaluates equipment fitness and integrity without permanently altering
physical state or arrangement.
nonisothermal "et
"et in which the primary air temperature differs from the mean space temperature.
nonuniform flow
fluid flow varying in velocity across the plane perpendicular to the flow.
nonvolatile refrigerant see refrigerant ?secondary refrigerant secondary coolant!@.
normali0ed lea$age
dimensionless value calculated from the lea$age area, building height, and floor area
that describes the relative airtightness of the building envelope. &ee also air infiltration
building!.
normally closed device
1. controlled device that closes when the control signal is off.
2. device that returns to the closed position when power is off.
normally open device
device that returns to the open position when power is off.
no00le
short tube with a taper or constriction used to speed up or direct a flow of fluid.
oil burner no00le
no00le for mechanically atomi0ing fuel oil in a burner.
return2flow no00le
no00le for a mechanical atomi0ing oil burner in which part of the oil supplied to the
atomi0er is withdrawn and returned to storage or to the oil line to the atomi0er.
spray no00le
orifice through which liquid is sprayed as in air washers and humidifiers.
oil
various viscous, combustible, water2immiscible liquids that are soluble in certain
organic solvents, and may be animal, vegetable, mineral, or synthetic in origin.
distillate oil
light fraction of oil, separated from crude oil by fractional distillation.
fuel oil
products of petroleum graded according to energy content and viscosity 9o. 1 to -!;
9o. - is residual oil, with the highest energy content and viscosity rating.
naphthenic oil
petroleum lubricating oil fraction in which naphthenic ring hydrocarbon structures
predominate.
paraffinic oil
petroleum lubricating oil fraction in which straight2 and.or branched2chain hydrocarbon
structures predominate.
refrigerating oil
stable fluid which is compatible with system components, will form a friction2reducing
film between rubbing surfaces, seal critical clearances, and has low2temperature
properties suitable for the application.
semisynthetic oil
mixture of synthetic and petroleum oils that can act as a lubricant.
synthetic oil
synthesi0ed material, often derived from petroleum compounds, but containing no
petroleum oil fractions, that can act as a lubricant.
white oil
severely refined petroleum2base lubricating oil fraction essentially free of aromatic
hydrocarbons.
oil charge
normal quantity of oil in a reciprocating compressor or engine.
oil2distribution system central!
system of piping through which oil is supplied from remote central supply tan$s! to one
or more buildings, mobile homes, recreational vehicles, or other structures.
oil fired
support of combustion in a furnace, stove, etc., by the in"ection of fuel oil.
oil pressure delivery
pressure of an oil pump in pressure2lubricated machines, or oil burners.
oil receiver
vessel for receiving and separating collected oil prior to returning to or discharging from
the refrigerating system.
oil rectifier oil still!
apparatus for purifying oil by vapori0ing the refrigerant contained.
oil removal
removal of oil or oil vapor from a refrigerant vapor.
oil return
migration of oil from the evaporator to the cran$case of the compressor. &ee
compressor oil return.
oil separator
device for separating oil and oil vapor from the refrigerant, usually installed in the
compressor discharge line.
oil still
device to separate oil from refrigerant by a distillation process.
oil trap
device for separating and collecting oil at a given point in a refrigerating circuit.
open2loop control system
control system that controls outputs by inputs only and the actual system output is not
considered.
operating life
expected useful life of a device, usually expressed in number of operations or years,
months, hours of typical operation.
operating load
point actual system operating capacity at the time of ta$ing an instrument reading.
orifice meter
instrument that measures fluid flow by recording differential pressure across a
restriction placed in the flow stream and the static or actual pressure acting on the
system.
orifice plate
relatively sharp2edged orifice in a plate used for the calculation of fluid flow rates from
measurements of the pressure difference between the two sides of the orifice.
Frsat apparatus
gas analy0er based on absorption of CF2, F2, etc. by separate chemicals that have a
selective affinity for each of those gases.
outlet area
gross overall discharge area of a given component in an air distribution system.
outlet valve see valve discharge!.
output
1. capacity, duty, performance, net refrigeration produced by a system.
2. general! current, voltage, power, or driving force delivered by a circuit or device;
terminals or other places where current, voltage, power, or driving force may be
delivered by a circuit of device.
#. electronic digital computer. 7ata that have been processed; state or sequence of
states occurring on a specified output channel; device or collective set of devices
used for ta$ing data out of a device; channel for expressing a state of a device or
logic element.
'. process of transferring data from an internal storage.
analog output
1. continuous variable used to represent another; e.g., in temperature measurement,
an electric voltage or current output represents temperature input.
2. varying quantity, e.g., pressure, voltage, or temperature, which can have any value
between a predetermined minimum and maximum, used as the corrective action in
a control system.
#. output that is continuously variable representing a physical variable such as a
voltage, current, or pressure output.
variable output
for each element of a control system, a physical quantity whose changes are
governed ultimately by the functioning of the element.
output rating
heating output capacity of a fuel2burning appliance.
overall thermal transfer value F%%E!
quantity of heat transferred per unit of temperature difference into a building through its
walls or roof, due to solar heat gain and outdoor2indoor temperature difference.
overpressure
pressure in excess of the designed normal operating range.
overshoot
1. condition in a control system where the controlled variable exceeds the desired set
point as a result of approaching that set point too quic$ly.
2. amount of the overtravel of an indicator beyond its final steady deflection when a new
constant value of the measured quantity is suddenly applied to the instrument.
#. excursion of the controlled variable beyond the differential or proportional band.
pac$ing
1. stuffing around a shaft or valve stem to prevent fluid lea$age. &ee also gland.
2. cooling tower pac$ing. &ee stuffing box.
shaft pac$ing gland pac$ing!
substance used in a stuffing box for pac$ing a gland to prevent lea$age.
parallax
1. apparent displacement of an ob"ect as seen from two different points not on a straight
line with the ob"ect.
2. inaccurate reading of a meter due to misaligned or angled line of vision between the
scale and the indicator.
particle
1. any relatively small subdivision of matter, ranging in diameter from a few nanometres
as with gas molecules! to a few millimetres as with large raindrops!.
2. any very small part of matter, such as a molecule, atom, or electron. 4lso $nown as
fundamental particle.
particle concentration
number of individual particles per unit volume of air.
particle si0e
apparent maximum linear dimension of a particle in the plane of observation.
particulate particulate matter!
state of matter in which solid or liquid substances exist in the form of aggregated
molecules or particles. 4irborne particulate matter is typically in the si0e range of ,.,1
to 1,, micrometres. &ee also atmospheric dust, respirable particles, total suspended
particulates.
part2load value >CE!
single number figure2of2merit expressing part2load efficiency for equipment on the basis
of weighted operation at various partial2load capacities for the equipment; expressed in
$ilowatts per ton of refrigeration.
application part2load value 4>CE!
part2load value based on operation at actual design conditions; typically used in
system design and specification.
integrated part2load value I>CE!
part2load value based on operation at standard 41I conditions; typically used for 41I
rating purposes.
pasteuri0ation
heat treatment of a fluid, usually at 1#, to 1-,)6 (( to /,)C! $illing bacteria, as in mil$,
without greatly changing its chemical composition, and greatly extending its shelf life.
penthouse
roofed structure incorporating louvers or louver blades in all or part of the walls, and
usually designed to be on the roof of a building.
perforated ceiling
one composed of perforated panels used to distribute the air uniformly throughout the
ceiling or portion of the ceiling.
peripheral equipment computer!
auxiliary machines that may be placed under the control of a central computer.
=xamples include magnetic tape drives and printers. >eripheral equipment may be
used on2line or off2line depending on computer design, "ob requirements, and
economics.
perm
empirical unit of water2vapor permeance; one perm 5 one grain avoirdupois! of water
vapor per hour flowing through one square foot of a material or construction induced by
a vapor2pressure difference of one inch of mercury across the two surfaces. 9ote: Aass
flow rate may be restated in other units consistent with the defined units. Fne perm is
the generally accepted maximum allowable permeance value for the residential building
envelope in a (,,, heating degree2day climate.
permafrost
in polar regions, and at some high2altitude areas, perennially fro0en soil. 9ote: It may
have an active layer of varying thic$ness at the surface, and it is this active layer that
causes most of the difficulties with permafrost.
permeability
time rate of water2vapor transmission through unit area of flat material of unit thic$ness
induced by unit vapor pressure difference between two specific surfaces, under
specified temperature and humidity conditions. Khen permeability varies with
psychrometric conditions, the spot or specific permeability defines the property at a
specific condition. 9ote: >ermeability is a property of a material, but the permeability of
a body that performs li$e a material may be used. >ermeability is the arithmetic product
of permeance and thic$ness.
permeance
water2vapor transmission of a body between two specified parallel surfaces, induced by
the vapor pressure difference between two surfaces. %he test conditions must be
stated. 4n accepted unit of water2vapor permeance is the perm. 9ote: >ermeance is a
performance evaluation and not a property of a material. &ee perm; rep.
phase
1. in thermodynamics, one of the three states of matter, solid, liquid, or gas.
continued on next page!
2. in an alternating electric current, the definite time relation of the alternations to the
rotational position of the alternator. In a polyphase machine, the phases are
separated by #-, electrical degrees divided by the number of phases.!
#. position in a cycle.
'. one conductor of several, each with different electrical phase.
phase change
shift of a material or system from one phase to another, such as liquid to gas, liquid to
solid, solid to gas. &ee state.
phase2change material pcm!
substance that undergoes changes of state while absorbing or re"ecting thermal energy
at constant temperature.
phon
unit of loudness level. &ound pressure level of a 1,,, hert0 reference tone, "udged by
the average listener to be equally loud to the sound being rated. Compare decibel.
photometer
radiometer designed for measuring luminous intensity, luminous flux, or illumination.
photovoltaic
ad". capable of generating a voltage as a result of exposure to visible or other radiation.
photovoltaic cell
device that detects or measures electromagnetic radiation by generating a potential at a
"unction barrier layer! between two types of material, on absorption of radiant energy.
4lso $nown as barrier2layer cell, barrier2layer photocell, boundary2layer photocell,
photronic photocell.
pie0ometer
instrument for measuring pressure or compressibility.
pilot duty
class of operation in which the ultimate load is controlled by auxiliary means.
pilot duty rating
volt2ampere rating that is applied to electric devices intended to control an
electromagnetic load, other than an electric motor, such as a control coil or other
solenoid.
pipe
hollow tube conduit for conveying gases, liquids, semiliquids, or finely divided solids;
and having wall thic$ness sufficient to be threaded. Compare piping; tube.
alloy steel pipe
steel pipe with one or more chemical elements other than carbon, which give it greater
resistance to corrosion and more strength than carbon steel pipe.
butt2weld pipe
pipe welded along a butted longitudinal seam, and not scarfed or lapped.
carbon steel pipe
pipe that owes its properties chiefly to the carbon content of the steel.
copper pipe
seamless copper pipe conforming to the particular dimensions commercially $nown as
standard pipe si0es.
galvani0ed steel pipe
pipe coated with 0inc to resist corrosion.
sparge pipe
pipe or tube containing a series of holes designed to equali0e the distribution of one
fluid stream into another.
pipe coupling
short internally threaded pipe for "oining two externally threaded pipe ends. &ee also
pipe fitting.
quic$2release pipe coupling quic$ coupler!
special type of connector which enables the easy coupling or uncoupling of fluid lines.
pipe fitting
parts used to "oin, adapt, or ad"ust other parts of the piping. &ee also flange; "oint;
manifold.
close nipple
nipple with a length twice the length of a standard pipe thread.
cross pipe
fitting with four branches in the same plane with right angles between them.
diversion pipe fitting
venturi "et or orifice in a tee that induces flow through branch lines by reducing the
pressure in the main following the branch.
elbow ell!
pipe fitting to ma$e an angle between connected pipes. If angle is not specified, a *,)
angle is implied.
nipple
short length of externally threaded pipe for connecting two internally threaded fittings.
pipe bushing
hollow plug with internal and external threads.
reducing pipe
bushing a reducing adapter with one end male and one end female.
pipe grids
1. in an ice rin$, the networ$ of pipes laid on the floor, through which refrigerant or a
cooling medium circulates to produce the ice slab.
2. in cold storage construction, a networ$ of pipes under the structure through which
heated fluid is circulated to prevent free0ing and consequent frost heave.
pipe run
1. assembly of more than one piece of pipe.
2. portion of a fitting having its end in line or nearly so, as distinct from the branch or
side opening, as of a tee.
pipe schedule
pipe si0e system listing outside diameters and wall thic$nesses for a variety of
pressures.
piping
1. system of pipes for carrying fluids.
continued on next page!
2. pipe or tube mains for interconnecting the various parts of a refrigerating system.
Compare system piping!.
grooved2"oint piping
coupling system that "oins pipes end2to2end by engaging circumferential grooves in
the pipe, using split couplings and a gas$et.
refrigeration piping
pipe or tube mains for interconnecting the various parts of a refrigerating system;
including pipe, flanges, bolting, gas$ets, valves, fittings, the pressure2containing parts
of other components such as expansion "oints, strainers, and devices that serve such
purposes as mixing, separating, muffling, snubbing, distributing, metering, or
controlling flow, pipe2supporting fixtures, and structural attachments.
piping cross connection nonpressure!
in a piping system, a connection in which a pipe carrying potable water is connected or
extended! below the overflow rim of a receptacle or in an environment! that is at
atmospheric pressure and that contains nonpotable fluid.
pressure cross connection
in a piping system, a connection in which a pipe carrying potable water is connected to
a closed vessel or system! that is above atmospheric pressure, and that contains
nonpotable fluid.
piston displacement swept volume!
volume displaced in one shaft revolution in a reciprocating compressor; may be given
for one piston or all pistons for total displacement.
piston stro$e
length of travel twice its cran$ radius!.
pitot tube
small bore tube inserted perpendicular to a flowing stream with its orifice facing the
stream to measure total pressure. 4t present, the term is often used for a double2tube
instrument from which the flow velocity can be calculated with one orifice facing the
flowing stream to register total pressure and the other perpendicular to the stream to
register static pressure.
pitting
formation of small depressions in a surface due to sand blasting, mechanical gouging,
acid etching, or corrosion.
plane radiant temperature
uniform temperature of an enclosure in which the incident radiant flux on one side of a
small plane element is the same as in the existing environment.
plastic
any of various nonmetallic compounds, synthetically produced usually from organic
compounds, by polymeri0ation! that can be molded into various forms, and hardened
for commercial use.
plenum chamber
in an air distribution system, that part of the casing, or an air chamber furnace, to or
from which the air duct system delivers conditioned air.
plug
1. an external2thread pipe fitting that is inserted into the open end of an internal thread
fitting to seal the end of a pipe. continued on next page!
2. sealing a hole in a vessel, such as a pipe or tan$, by inserting material in the hole and
then securing it.
#. material used to plug the hole.
polytrope
graphical line representing a polytropic process.
polytropic process
one in which heat is being exchanged with the surroundings, represented by the
equation pvn 5 constant n is the polytropic exponent!.
positive heat supply
heat supplied to a space by design or by heat losses occurring from energy2consuming
systems or components associated with that space.
postpurge operation
operating a burner fan after flame shutdown. &ee purge.
potentiometer
1. instrument for measuring or comparing small electromotive forces, such as those
produced by thermocouples.
2. instrument for comparing small electromotive forces, or for measuring small
electromotive forces, by comparison with a $nown electromotive force. Its principal
advantage is that during the measurement, no current flows through the source of
electromotive force.
#. three2terminal rheostat, or a resistor with one or more ad"ustable sliding contacts, that
functions as an ad"ustable voltage divider.
power
time rate of doing wor$, usually expressed in horse2power $ilowatts!. &ee horsepower.
precipitator
device to remove fine ash, tars, dusts, or smo$e particles from flue gases or other
gaseous streams; the device may employ mechanical, electrostatic, or chemical
means, or a combination of these. &ee air cleaner.
electric precipitator
device for removing dust from air by means of electric charges induced on the dust
particles.
electrostatic precipitator
device for removing dust from the air by inducing an electric charge on the dust
particles.
precision
closeness of agreement among repeated measurements of the same characteristic by
the same method under the same conditions. &ee accuracy; reliability; repeatability.
preheating
1. heating a food product prior to a subsequent treatment.
2. in air conditioning, to heat the air ahead of other processes.
prepurge operation
operating a burner blower prior to flame ignition to blow out possible lea$ed gas. &ee
purge.
pressure
1. thermodynamically, the normal force exerted by a homogeneous liquid or gas, per
unit of area, on the wall of the container.
2. force exerted per unit area. 9ote: %he terms head and pressure often are used
interchangeably; however, head is the height of a fluid column supported by fluid
flow, while pressure is the normal force per unit area. 6or liquids, it is convenient to
measure the head in terms of the flowing fluid. Kith a gas or air, however, it is
customary to measure pressure on a column of liquid.
absolute pressure
pressure above a perfect vacuum; the sum of gage pressure and atmospheric
pressure.
ambient pressure
1. environmental pressure in which a device operates.
2. pressure of the medium surrounding a device.
atmospheric pressure
1. pressure of the outdoor atmosphere.
2. standard atmospheric reference pressure assumed sea level! is defined by the
IC4F International Civil 4eronautics Frgani0ation! as 1,1.#2( $>a. In I2> units the
value is approximately 1'.-*- psi, or 2*.*21 inches of mercury at #2)6.
balance pressure
pressure in a system or container equal to that outside.
condensing pressure
pressure of a gas at which it condenses.
critical pressure
for a specific fluid, the vapor pressure at which the liquid and vapor have identical
properties.
design wor$ing pressure
1. in the 8nited &tates, the maximum wor$ing pressure for which an apparatus has
been designed.
2. in some countries, the design pressure is greater than the maximum wor$ing
pressure. &ee operating pressure.
differential pressure
difference in pressure between any two points in a system.
discharge pressure
operating pressure in a system measured in the discharge line at the compressor or
fan outlet.
dynamic pressure
additional pressure exerted by a fluid due to motion.
excess pressure pressure exceeding the design value or a standard value.
final pressure
pressure of a fluid leaving a process.
gage pressure
pressure above atmospheric pressure.
head pressure
operating pressure measured in the discharge line at a pump, fan or compressor
outlet; i.e., at the head.
hydrostatic pressure
1. pressure exerted by a fluid at rest.
2. normal force per unit area that would be exerted by a moving fluid on an
infinitesimally small body immersed in it if the body were carried along with the
fluid.
impact pressure
velocity pressure plus static pressure.
initial pressure
pressure of fluid entering the system.
intermediate pressure interstage pressure!
pressure prevailing between stages of multistage compression.
maximum allowable pressure
maximum gage pressure permitted on a completed system; the setting of the
pressure2relieving devices protecting the system.
negative air pressure
in a building, pressure lower than pressure outside. 9ote: 4s the negative pressure
increases, outside air is drawn in through any openings in the building envelope.
operating pressure wor$ing pressure!
pressure indicated by a gage when the system is in normal operation.
osmotic pressure
differential pressure which must be applied to the fluid on one side of a
semipermeable membrane to prevent diffusion through the membrane.
partial pressure
portion of total gas pressure of a mixture attributable to one component 7altonPs law
of gases!.
positive air pressure
in a building, pressure greater than pressure outside. 9ote: 4s the positive pressure
increases, it forces indoor air out through any openings in the building envelope.
residual pressure
in free0e drying, the pressure of the gas usually air! at the trap.
reverse pressure
1. pressure differential existing in a heat pump! reversing valve to effect a reversal of
flow through the valve.
2. output pressure of a reversing relay which changes in opposition of the input signal,
i.e., as the input pressure increases, the output pressure decreases.
saturation pressure
for a pure substance at a given temperature, the pressure at which vapor and liquid, or
vapor and solids, can exist in equilibrium.
static pressure
1. pressure exerted by a fluid at rest.
2. in a flowing fluid, the total pressure minus velocity pressure. &ee hydrostatic
pressure.
suction pressure
operating pressure in a system measured in the suction line at the compressor inlet.
supply pressure
1. energy source to a controller or auxiliary device.
2. pressure of supply mains of a pneumatic control system.
test pressure
pressure, usually higher than the design wor$ing pressure, to which a piece of
equipment is sub"ected for testing according to specified procedures.
total pressure
in fluid flow, the sum of static pressure and velocity pressure.
velocity pressure
in a mo)in' f#!id( the press!re d!e to the )e#o$ity and density of the f#!id( e&pressed
"y the )e#o$ity s,!ared times the f#!id density( di)ided "y two *⟩V 222+%
pressure dependent >7!
ad". varying flow rate through a flow control device in response to changes in pressure.
pressure drop
1. loss in pressure, as from one end of a refrigerant line to the other, from friction, static,
heat, etc.
2. difference in pres2sure between two points in a flow system, usually caused by
frictional resistance to fluid flow in a conduit, filter, or other flow system. Compare
pressure loss.
pressure equali0ing
allowing high2 and low2side pressures to equali0e or nearly equali0e during idle periods
by an unloading valve or by a vapor loc$ liquid control, or nearly equali0ing inlet and
discharge pressures on compressors to reduce starting torque load.
pressure2imposing element
device for increasing the pressure on a fluid, e.g., refrigerant or other gases.
pressure independent >I!
ad". uniform flow rate through a flow control device unaffected by changes in system
pressure.
pressure2limiting device
pressure2responsive mechanism designed to stop automatically the operation of a
pressure imposing element at a predetermined pressure.
pressure loss
change in total pressure due to friction and turbulence. Compare pressure drop.
pressure regulator
device to maintain controlled downstream fluid pressure with varying upstream
pressure.
pressure relief
designed automatic reduction of excessive pressure in a vessel.
pressure relief device
1. valve or rupture member designed to relieve excessive pressure automatically.
2. means for relieving internal pressure and preventing explosive shattering of the
housing.
pressure relief vessel
container or tan$ which allows the relief into it of excessive pressure automatically.
pressure tubing
1. practical designation for seamless steel tubing less than 1.( in. outside diameter
#/ mm!. 4&%A 1,- pressure tubing in steam plant design.
2. any plastic or metal tubing to convey fluid under pressure.
pressure vessel
container for fluids at a pressure different from atmospheric pressure vacuum to high!,
capable of withstanding associated stresses.
refrigeration pressure vessel
any refrigerant2containing receptacle in a refrigerating system. %his does not include
evaporators each separate section of which does not exceed ,.( ft# ,.,1' m#! of
refrigerant2containing volume, evaporator coils, compressors, condenser coils,
controls, headers, pumps, and piping.
prime mover
engine, turbine, water wheel, or similar machine which drives an electric generator.
product integrated control >IC!
direct digital control 77C! panel, factory2mounted and connected, able to monitor,
control, and diagnose the significant functions of the equipment of which it is a part.
Compare field2installed device.
psychrometer
instrument for measuring relative humidities with wet2 and dry2bulb thermometers. &ee
hygrometer.
aspirated psychrometer
psychrometer having mechanical means for rapidly circulating air to be tested over dry
and wet bulbs.
sling psychrometer
hygrometer of two matched thermometers, one with its bulb wetted and the other dry,
capable of being whirled rapidly on a sling, to indicate the temperature differences
related to relative humidity.
psychrometric
ad". relating to the measurement or determination of atmospheric conditions,
particularly regarding moisture mixed with air.
psychrometric chart
graphical representation of the properties of moist air, usually including wet2 and drybulb
temperatures, specific and relative humidities, enthalpy, and density.
psychrometry
branch of physics concerned with the measurement or determination of atmospheric
conditions, particularly the moisture in air.
psychrophilic
ad". pertaining to microorganisms growing at low temperatures, and having an optimum
growth temperature near #2)6 ,)C!.
pulldown test
first operational chec$ on a refrigerating installation to measure the time ta$en to pull
the temperature down to the desired conditions, while also measuring the
temperatures, pressures, and associated data.
pump
machine for imparting energy to a fluid causing it to do wor$, drawing a fluid into itself
through an entrance port, and forcing the fluid out through an exhaust port. Aain types
are air lift, centrifugal, diaphragm, positive displacement, reciprocating, and rotary.
boiler feed pump
pump which returns condensed steam, ma$eup water, or both directly to the boiler;
normally installed with a large receiver.
centrifugal pump
pump having a stationary element casing! and a rotary element impeller! fitted with
vanes or blades arranged in a circular pattern around an inlet opening at the center.
%he casing surrounds the impeller and usually has the form of a scroll or volute.
condensate return pump
pump used to transfer condensate from one point in a system to another receiver;
usually installed with a receiver tan$ and a float valve; the pump being controlled by
tan$ level.
"et pump
e"ector or in"ector pump.
liquid mechanical vacuum pump
vacuum pump in which the flow of the gas is induced by a vaned rotor and a mass of
liquid pro"ected by centrifugal force against the stator.
pressure2powered pump
receiver device having inlet and outlet nonreturn valves and a float2operated
mechanism, enabling a secondary medium steam, compressed air, or inert gas! to
pressuri0e the receiver body through a fill2and2discharge cycle actuated from the float
mechanism.
vacuum diffusion pump
pump in which the motion of a gas is induced by its diffusion into the vapor phase of a
wor$ing fluid in the pump.
vacuum pump
1. pump for exhausting a system; pump designed to produce a vacuum in a closed
system or vessel.
2. pump used to remove air and moisture from the inside of a refrigeration system.
#. ion pump! vacuum pump operated via the ioni0ation of gases, the produced ions
being transported by an electrical or magnetic field.
pumpage
general term for any fluid that is mechanically pumped.
pumpdown
of refrigerant, withdrawal of all refrigerant from the low side of a system by pumping it to
either the condenser or the liquid receiver.
purge
1. removal of unburned gases from a combustion chamber.
2. removal of air from a water2heating system.
#. device to remove noncondensable gases from a refrigerating system.
purge recovery system purger!
system used to recover refrigerant from purged mixture of gases and water.
static purge system
system in which differential pressure is used to remove noncondensables from a
centrifugal system.
pyranometer
radiometer !sed to meas!re so#ar radiation re$ei)ed from the who#e hemisphere *2 
steradians+% Note: .he instr!ment is s!ita"#e for meas!rement of '#o"a# or diff!se so#ar
radiation%
pyrgeometer
radiometer designed to measure terrestrial long wavelength! radiation only.
pyrheliometer
radiometer used to measure the direct or beam solar irradiance incident on a surface
normal to the sunPs rays.
pyrometer
instrument for measuring temperature, usually above the range of mercury
thermometers.
quad
one quadrillion; 1, to the 1(th power 1,1(! not an &I quantity!.
quality assurance
testing and inspection of all or a portion of a final product, assembly, or system to
ensure that the desired quality level is attained.
quality control
inspection, analysis, and action applied to a portion of a product, assembly, or system in
the manufacturing or construction operation, to estimate overall quality, and to
determine what, if any, changes must be made to achieve or maintain a desired quality
level.
quasi2steady state solar collector!
condition of operation of the collector and.or system in which the measured solar
irradiance, flow rates, and thermodynamic states of temperature and pressure at
various points in the collector and.or system do not vary during the period of test
measurements.
radial distance chimney!
shortest distance from receptor location to centerline of the chimney outlet.
radiance
total radiant flux emitted from a surface through unit pro"ected area by unit solid angle. It
includes the self2emitted radiation plus reflections from sources other than the ob"ect
evaluated as interpreted from the direction of measurement. %he term intensity of
radiation is sometimes used as a synonym for radiance. &ee also radiosity.
radiant
ad". radiating rays of light; emitting or reflecting beams of light; vividly shining; glowing;
brilliant.
radiant flux !
time rate of flow of radiant energy watts!.
radiant flux density
measure of radiant power per unit area flowing across or onto a surface. 4lso called
irradiance!.
radiant reflectance luminous reflectance! ⟩!
ratio of the reflected radiant or luminous! flux to the incident radiant or luminous! flux.
radiant temperature asymmetry
difference between the plane radiant temperature of two opposite sides of a small plane
element.
radiant transmittance luminous transmittance! © !
ratio of the transmitted radiant or luminous! flux to the incident radiant flux.
radiation
act or process of radiating, specifically the process by which energy is emitted from
molecules and atoms, owing primarily to internal temperature change.
electromagnetic radiation
electromagnetic waves, and especially the associated electromagnetic energy.
radiation angle factor shape factor!
when the space above an element of surface is partially occupied by a body exchanging
radiant energy with the surface, the angle factor represents the fraction of the angular
field of view where energy exchange is ta$ing place.
radiation pasteuri0ation
irradiation, using moderate doses, to enhance $eeping quality by $illing most of the
spoilage microorganisms present; viruses are not affected.
radiation shield
1. device designed to intercept radiated heat.
2. in a furnace, a sheet of metal or other material supported between the heat
exchanger and the casing to protect the casing from heat; not to be considered as a
heat transfer surface.
radiation sterili0ation
irradiation using high doses to $ill the microorganisms present.
radiator convector radiator!
terminal unit used in hot water or steam systems to deliver heat to a space but primarily
by convection and not radiation!.
baseboard radiator
heating device located at or replacing a room baseboard.
finned2tube radiator
wall2mounted heater with a plurality of fins bonded to a tube, usually carrying steam or
hot water.
radiometer
instrument for measuring irradiance in energy or power units.
radiosity
total radiant flux that leaves unit area of a surface. %he sum of radiant flux emitted and
reflected by the surface, plus any radiant flux transmitted through that surface.
Compare exitance.
14A
random access memory computer!.
rate base electric!
monetary value established by a regulatory authority, on which a utility is permitted to
earn a specified rate of return.
rating
assigned value of those performance characteristics under standard rating conditions!
by which a unit may be selected to fit its application. 9ote: %hese values apply to all
units of li$e nominal! si0e and type identification! produced by the same manufacturer.
application rating
rating based on tests performed at other than standard rating conditions.
standard rating
rating based on tests performed at standard rating conditions.
rating conditions
set of operating conditions under which a single level of performance results, and which
causes only that level of performance to occur.
application rating conditions
rating conditions other than standard rating conditions.
standard rating conditions
rating conditions used as the basis of comparison of performance characteristics.
reciprocating
ad". moving forward and bac$ward alternately.
recirculation of discharge air
1. condition pertaining to cooling towers and evaporative condensers in which a portion
of the discharge air enters along with the fresh air; the amount of recirculation is
determined by equipment design, placement in regard to ad"oining ob"ects, and
atmospheric conditions. %he effect is generally evaluated on the basis of the
increase in entering wet2bulb temperature compared to the ambient.
2. a condition pertaining to air2cooled condensers in which a portion of the discharge air
enters along with the fresh air; the amount of recirculation is determined by
equipment design, placement in regard to ad"oining ob"ects, and atmospheric
conditions. %he effect is generally evaluated on the basis of the decrease in unit
capacity.
recirculation refrigerating system
liquid overfeed system preferred term!. &ee refrigerating system.
recirculation2type evaporator
circulating2type evaporator preferred term!. &ee evaporator.
rectifier
1. externally2cooled heat exchanger in the high side of a refrigerating absorption system
for condensing absorbent and separating it from the refrigerant before passing it to
the condenser.
2. in electricity, a device for converting 4C to 7C current.
reefer
refrigerated space or refrigerated transport carrier
reflectance
portion of the incident radiation on a surface that is reflected from the surface. 9ote:
6or an opaque surface, the sum of the reflectance and the absorptance is unity at
equilibrium. 4bsorptances and reflectances are of various types, as are emittances. 6or
most engineering purposes, the counterparts of the hemispherical total emittance
suffice.
diffuse reflectance
directional hemispherical reflectance less the specular reflectance.
reflectivity
portion of the radiation stri$ing unit area of a surface that is not absorbed or transmitted
by the surface. &ee reflectance.
refrigerant
1. in a refrigerating system, the medium of heat transfer which pic$s up heat by
evaporating at a low temperature and pressure, and gives up heat on condensing at
a higher temperature and pressure.
2. refrigerating fluid! fluid used for heat transfer in a refrigerating system which absorbs
heat at a low temperature and low pressure of the fluid and transfers heat at a higher
temperature and a higher pressure of the fluid, usually involving changes of state of
the fluid. Compare coolant.
alternate refrigerant
replacement refrigerant that can accomplish the same tas$ as the one being replaced,
but may require that refrigeration or air2conditioning equipment be redesigned or
replaced. Compare drop2in refrigerant.
ammonia refrigerant
anhydrous ammonia 9<#!.
a0eotropic refrigerant
blend of two or more component refrigerants whose equilibrium vapor2phase and
liquid2phase compositions are the same at a given pressure. Compare 0eotropic
refrigerant.
drop2in refrigerant
replacement refrigerant that has thermodynamic properties similar to one being
replaced, and does not require air2conditioning or refrigerating equipment to be
replaced, but may require modifications.
expendable refrigerant
1. liquefied gas generally liquid nitrogen! whose vapor is lost after change of phase.
2. solid carbon dioxide dry ice!.
flammable refrigerant
refrigerant that is ignitable when mixed with air, e.g., ethyl chloride, methyl chloride,
and the hydrocarbons. 9ote: &ee 4&<14= &tandard #' for flammability categories.
halocarbon refrigerant
hydrocarbon compound with fluorine, chlorine, or bromine.
primary refrigerant
wor$ing fluid of a refrigerating cycle as opposed to secondary refrigerant!.
secondary refrigerant secondary coolant!
volatile or nonvolatile substance in an indirect refrigerating system that absorbs heat
from a substance in space to be refrigerated and transfers this heat to the evaporator
of the refrigerating system.
0eotropic refrigerant
blend of two or more component refrigerants whose equilibrium vapor2phase and
liquid2phase compositions are different at a given temperature.
refrigerant charge
1. actual amount of refrigerant in a closed system.
2. weight of refrigerant required for proper functioning of a closed system.
critical refrigerant charge
compromise refrigerant quantity required by a system to maximi0e performance when
a capillary or fixed restriction expansion device is used.
holding charge service charge!
reduced quantity of refrigerant or inert gas used to avoid the ingress of air and
moisture into a component, before startup.
limited refrigerant charge
charge that does not exceed the design pressure at complete evaporation.
optimum refrigerant charge
charge achieving maximum possible refrigerant effect within design limitations.
refrigerant compressor
component of a refrigerating system which increases the pressure of a compressible
refrigerant fluid and simultaneously reduces its volume, while moving the fluid through
the device. &ee also compressor.
accessible hermetic semihermetic! refrigerant compressor
hermetic refrigerant compressor whose housing is sealed by one or more gas$eted
"oints and is provided with means of access for servicing internal parts in the field.
welded hermetic refrigerant compressor
hermetic refrigerant compressor whose housing is permanently sealed by welding or
bra0ing and is not provided with means of access for servicing internal parts in the
field.
refrigerant cylinder gas bottle!
cylindrical steel pressure vessel with operable closure for the storage and transport of
refrigerant.
service cylinder gas bottle!
small refrigerant cylinder used by a service person.
refrigerant distributor
device used in con"unction with a thermostatic expansion valve to ensure equable
refrigerant distribution from the valve to individual parallel sections of an evaporator.
refrigerant flow rate
mass flow rate of refrigerant pumped or moved through a system at specified
temperature and pressure.
specific refrigerant flow rate
flow rate in lb.min g.s! required to produce one ton $K! of refrigerating effect at the
conditions indicated.
refrigerant heat re"ection
total useful capacity of a refrigerant condenser for removing heat from the refrigerant
circulated through it.
condensing heat re"ection
that portion of the total refrigerant heat2re"ecting effect of a condenser which is used
for condensing the entering refrigerant vapor to a saturated liquid at the entering
refrigerant pressure.
desuperheating heat re"ection
sensible heat re"ection in a condenser from gaseous refrigerant generally occurring
prior to the gas2to2liquid phase change!.
subcooling heat re"ection
sensible heat re"ection in a condenser from liquid refrigerant generally occurring after
the gas2to2liquid phase change!. &ee also cooling; refrigerant subcooling.
refrigerant hydrolysis
splitting of refrigerant compounds by reaction with water; e.g., reaction of
dichlorodifluoromethane or methyl chloride with water, forming acid products.
refrigerant2liquid pressure reducer
device or devices, in a refrigerating system, in which the pressure of the fluid is reduced
from that of condensed liquid to that of the evaporator.
refrigerant metering device
device which controls the flow of liquid refrigerant to an evaporator.
refrigerant pressure2imposing device
device or portion of equipment used for the purpose of increasing refrigerant pressure.
refrigerant processing
refrigerant reclaim
to reprocess refrigerant to new conditions, by means which may include distillation.
Aay require chemical analysis of the contaminated refrigerant to determine that
appropriate process specifications are met. %his term usually implies the use of
processes or procedures available only at a reprocessing or manufacturing facility.
refrigerant recovery
to remove refrigerant in any condition from a system and to store it in an external
container without necessarily testing or processing it in any way.
refrigerant recycling
to clean refrigerant for reuse by oil separation and single or multiple passes through
moisture absorption devices, such as filter driers with replaceable cores. %his
procedure is usually implemented at the field site or at a local service shop.
refrigerant pump2out system
dedicated apparatus for transfer of refrigerant from a chiller or other refrigerating
system to a separate and distinct storage vessel.
refrigerant receiver
vessel in a refrigerating system designed to ensure the availability of adequate liquid
refrigerant for proper functioning of the system, and to store the liquid refrigerant when
the system is pumped down.
controlled2pressure receiver cpr!
intermediate pressure receiver used to flash cool refrigerant and to control the feed
pressure.
liquid receiver
vessel, permanently connected to a refrigerating system by inlet and outlet pipes, for
storage of liquid refrigerant.
low2pressure receiver surge drum; accumulator!
vessel on the low side of a refrigerating system into which liquid refrigerant can collect
to be used to supply evaporators.
refrigerant subcooler
heat exchanger, after the condenser, for subcooling the condensed refrigerant.
refrigerant subcooling
process of cooling refrigerant below condensing temperature for a given pressure; also,
cooling a liquid below its free0ing point where it can exist only in a state of unstable
equilibrium. &ee supercooling.
specific heat of a subcooled refrigerant
difference in specific enthalpies of a pure condensable fluid between the saturated
not subcooled! liquid state and the cooled liquid at a given temperature below its
condensation temperature at the same pressure.
refrigerate
to subtract heat from a substance or space to maintain the temperature below #,)6
R1)C!. 4bove this temperature, the process is called cooling.
refrigerated volume
space under refrigeration.
net free0er refrigerated volume
that portion of the net refrigerated volume 1! below #2)6 ,)C! average! for
household refrigerators, and 2! +)6 )1#)C! average! or below for household
combination refrigerator2free0ers and household free0ers exception: see net general
refrigerated volume!.
net general refrigerated volume
that portion of the net refrigerated volume 1! above #2)6 ,)C! average for household
refrigerators and Ball2refrigeratorsD or 2! above +)6 R1#)C! average for household
combination refrigerator2free0ers; including the volume of the refrigerated chiller tray
and other special compartments! for storage of fresh foods approaching #2)6 ,)C!.
net refrigerated volume
for household refrigerators and combination refrigerator2free0ers, the sum of the net
general2cooled volume and the net free0er2refrigerated volume. 6or household allpurpose
refrigerators, the net general refrigerated volume. 6or a household free0er,
the net free0er2refrigerated volume.
refrigerated warehouse
building used to preserve goods under refrigerated conditions.
refrigerating capacity gross!
total rate of heat removal from all sources by the evaporator of a refrigerating system at
stated conditions. It is numerically equal to the system refrigerating effect.
net cooler refrigerating capacity
rate of heat removal from a fluid flowing through a cooler air, water, brine, etc.! at
stated conditions; the difference in specific enthalpies of the cooling fluid entering and
leaving the cooler. In case frosting occurs within the cooler, the latent heat of fusion
and the subcooling heat of the ice frost! must be added in determining the net cooler
refrigerating capacity.
net refrigerating
remaining rate of heat removal remaining from all sources by the evaporator of a
refrigerating system, at stated conditions, after deducting internal and external heat
transfers to the evaporator that occur before distribution of the refrigerating medium
and after its return.
refrigerating capillary tube
tube of small bore ?down to ,.,2, in. I7 ,.(, mm!@ used for the simultaneous purposes
of metering the refrigerant and of accomplishing the expansion process between
condenser and evaporator in refrigerating systems. &ee also tube. Compare valve
?refrigerant control valve refrigerant expansion valve!@.
refrigerating cargo vessel
vessel whose holds are totally or partly refrigerated.
refrigerating heating system
interconnected parts forming a closed circuit in which refrigerant is circulated, and
having the condenser located to transfer heat to the 0one to be heated.
refrigerating plant
refrigerating system.
refrigerating system
system that, in operation between a heat source evaporator! and a heat sin$
condenser! at two different temperatures, absorbs heat from the heat source at the
lower temperature and re"ects heat to the heat sin$ at the higher temperature. &ee also
refrigerating unit.
absorption2type refrigerating system
refrigerating system in which refrigeration is created by evaporating a refrigerant in a
heat exchanger evaporator!, with the vapor then absorbed by an absorbent medium
from which it is subsequently expelled by heating at a higher partial vapor pressure in
a generator! and condensed by cooling in another heat exchanger condenser!.
brine spray refrigerating system
cooling of air by spraying brine into the airstream. 9ote: >rocess discontinued in meat
refrigerating plants because of salt corrosion of meat2carrying rails.
cascade refrigerating system
one having two or more refrigerant circuits, each with a pressure imposing element,
condenser, and evaporator, where the evaporator of one circuit cools the condenser of
another lower temperature! circuit.
central2plant refrigerating system
system with two or more low sides connected to a single, central high side; a multiple
system.
class of refrigerating system
formerly in extensive use but now becoming obsolete as a result of code change to
classification. &ee 4&<14= &tandard 1(.
closed secondary coolant refrigerating system
system in which the secondary coolant is completely enclosed and shut off from the
atmosphere throughout the cycle, except for a vented expansion tan$ at the high point
of the system.
compound refrigerating system
multistaged refrigerating system where a single charge of refrigerant circulates
through all stages of compression.
compression2type refrigerating system
system in which the temperature and pressure of a gaseous refrigerant are increased
mechanically. In most cases, the refrigerant undergoes changes of state.
direct refrigerating system
system in which the refrigerant evaporator or condenser is in direct contact with the air
or substance to be cooled or heated.
direct2expansion dry2expansion! refrigerating system
system in which the cooling effect is obtained directly from the refrigerant.
engineered refrigerating system
system that requires specific engineering analysis of all components as a group to
accomplish the desired results.
hermetically2sealed compression refrigerating system
system that uses a sealed hermetic! compressor.
indirect refrigerating system
system in which a secondary coolant, cooled or heated by the refrigerating system, is
circulated to the air or substance to be cooled or heated.
limited2charge system
system in which, with the compressor idle, the design pressure will not be exceeded
when the refrigerant charge has completely evaporated.
liquid2circulation refrigerating system
system in which refrigerant liquid is flashed to saturated suction pressure and
temperature in an accumulator and is then fed by a mechanical pump or by refrigerant
vapor pressure to the evaporators. %his liquid is normally fed at a rate greater than the
evaporating rate for the refrigerant to ensure wetting of the entire evaporator surface
for greater heat transfer.
liquid2overfeed system
system feeding an evaporator with refrigerant at a rate to ma$e the exit quality less
than one. Compare liquid2recirculation refrigerating system.
mechanical refrigerating system
refrigerating system using mechanical compression to remove the refrigerant from the
low2pressure side and to deliver it to the high2pressure side of the system.
multiple refrigerating system
system in which refrigerant is delivered to two or more evaporators in separate rooms
or refrigerators.
multistage refrigerating system
system in which compression of refrigerant is carried out in two or more steps.
no2frost refrigerating system
1. system in which all the refrigerated surfaces in the cabinet are defrosted by an
automatic defrost system.
2. use of a secondary coolant sprayed on evaporator surfaces to prevent formation of
frost; water absorbed in the coolant being removed by distillation.
open2brine refrigerating system
system in which the circulating brine returns to an open tan$ which serves as a
reservoir for the pump suction and as an inspection tan$ for the condition and flow of
brine.
partial2recovery refrigerating system
historic system in which the evaporating refrigerant is partially recovered by bringing it
into contact with a condenser e.g., halocarbon free0ing!.
piggybac$ refrigerating system
two chilling plants, centrifugal and absorption, usually steam2driven, using the same
steam supply in sequence, with chilled water running counterflow to stream.
recirculation refrigerating system
liquid overfeed system preferred term!. &ee refrigerating system.
regenerative air cycle system
air cycle refrigerating system fitted with heat regenerators.
removable2unit refrigerating system
system, readily removable as one unit from the cabinet or space that it cools and from
the building in which it is used without disconnecting any part of the system that
contains refrigerant. &ee also refrigerating unit.
resorption2type refrigerating system
system in which the refrigerant vapor is not condensed to a pure liquid but is absorbed
in a wea$ solution from which it is subsequently evaporated at a lower temperature to
produce refrigeration.
self2contained refrigerating system single2pac$aged!
unitary refrigerating system. &ee also refrigerating unit.
steam2"et refrigerating system
system in which high2pressure steam, supplied through a no00le and acting to e"ect
water vapor from the evaporator, maintains the requisite low pressure on one side and
produces a high pressure on the other by virtue of compression in a following diffusion
passage. &ometimes called e"ector2cycle refrigerating system.
total2loss refrigerating system
expendable refrigerating system.
unitary refrigerating system
complete factory2assembled and tested refrigerating system comprising one or more
assemblies which may be shipped as one unit or separately, but which are designed
to be used together. &ee also refrigerating unit.
vapor refrigerating system
system using a condensable vapor as the refrigerant.
water2vacuum refrigerating system
one that employs a vacuum to boil water at the temperature desired; one in which
evaporating water vapor is the refrigerant.
wet compression system
system of refrigeration in which some liquid refrigerant is mixed with vapor entering
the compressor to cause the discharge vapor from the compressor to be saturated,
rather than superheated.
refrigerating system contaminants
contaminants include water most important and universal contaminant!; dirt; particles;
organic materials such as waxes, acids, and sludges; or other products of chemical
reactions ta$ing place while the system is operating.
refrigerating system high side
parts sub"ected to approximately the condenser pressure.
refrigerating system low side
parts sub"ected to approximately the evaporator pressure.
refrigerating system machinery
refrigerating equipment forming a part of the refrigerating system including any or all of
the following: compressor, condenser, generator, absorber adsorber!, liquid receiver,
connecting piping, and evaporator.
refrigerating system pressure vessel
refrigerant2containing pressure vessel of a refrigerating system, other than evaporators
in which each separate section does not exceed ,.( ft# ,.,1' m#! of refrigerantcontaining
volume, evaporator coils, compressors, condenser coils, controls, headers,
and piping.
refrigerating system restrictor
device capable of providing the necessary difference in pressure between the high2 and
low2pressure sides of the refrigerating system.
refrigerating unit
unit assembly comprising a compressor, evaporator, condenser, and expansion device,
used for refrigerating and for extracting heat.
clip2on refrigerating unit
refrigerating unit which can be attached to an insulated cargo container to provide
cooling.
straddle refrigerating unit saddle unit; plug unit!
factory2assembled refrigerating system mounted at high level in the insulated wall of a
cold store with the evaporator inside the store and the rest of the unit outside.
thermoelectric refrigerating module thermoelectric battery!
small device using the >eltier effect, consisting of an assembly of semiconducting
bloc$s fed by a direct current. Fne face of the device cools while the other face warms
up, and the thermal effect may be reversed by reversing the direction of the current.
underslung refrigerating unit
unit that is attached under the chassis of a vehicle to be cooled.
refrigeration
1. process of extracting heat from a substance or space by any means; usually at a low
temperature.
2. any use of mechanical or absorption refrigerating machinery for applications other
than comfort of human beings. Compare cooling.
air cycle refrigeration
consists of four stages: compression of air, cooling the air down to ambient
temperature, expansion of the air, and heating of the cold air by heat absorption in the
space to be cooled.
thermoelectric refrigeration thermoelectric cooling!
method for cooling by the >eltier effect.
refrigerator
cabinet or room for $eeping food or other items cool.
closed refrigerator
food store self2service display refrigerator in which a pac$aged product is accessible
for removal by opening vertically hinged doors or sliding doors. Chest2type cabinets,
service delicatessen, and customer2service meat cases are not included.
commercial refrigerator
1. refrigerated enclosure containing goods which are accessible from the exterior
through a door.
2. types of refrigerators used commercially, including reach2ins, wal$2ins, and
refrigerated display cases all types being either service or self2service, which are
used by business establishments!.
dual2temperature refrigerator
two2compartment refrigerated cabinet, with one used for chilling foods and the other
for either free0ing foods or storing fro0en products.
electric refrigerator
self2contained unit comprising an insulated cabinet, evaporator, and electric motordriven
condensing unit with controls.
gas refrigerator
one using the heat of burning gas to cool a cabinet.
household refrigerator
cabinet or any part of a cabinet which is designed for the refrigerated storage of food
at temperatures above #2)6 ,)C! but preferably below ',)6 ()C!, has a source of
refrigeration, and is intended for household use. It may include a compartment for the
free0ing and storage of ice and for the short2term storage of food at temperatures
below #2)6 ,)C!.
low2temperature refrigerator
refrigerator in which the food product is fro0en.
medium2temperature refrigerator
refrigerator in which the food product temperatures are normally above free0ing.
nursery refrigerator
one having the cabinet interior designed to receive feed2bottle carriers.
reach2in refrigerator
self2contained, commercial refrigerator for product refrigeration, display, and
merchandising.
remote refrigerator
refrigerator which has the condensing unit located separate from the refrigerator.
9ormally, several refrigerators may be connected to the same condensing unit.
self2contained refrigerator
refrigerator that has the condensing unit built into the cabinet, as opposed to a remote
condensing unit.
wal$2in refrigerator
refrigerated enclosure large enough for persons to wal$ into.
refrigerator cabinet brea$er strip
separate insulating element or integral insulating extension of the cabinet interior
surfaces around the periphery of the cabinet door or drawer openings!, which functions
as a thermal barrier to minimi0e heat flow to the cabinet interior; i.e., it brea$s a thermal
lea$age path.
refrigerator load limit
maximum volume available within the display or storage compartments of the display
refrigerator usable for food products.
refrigerator shelf net area
calculated value based on the net area of the main shelves, door shelves, bottoms of
suspended containers or dispensers, and the bottom of the liners! of the general
refrigerated and free0er compartments.
regain of moisture
mass of moisture reabsorbed by a dried material when exposed to humid air.
register
combination grille and damper assembly over an air opening. &ee air outlet.
registered engineer
appropriately qualified and licensed professional engineer. &ee also design
professional.
regulator
device to establish or ad"ust the time, amount, degree, or rate of a unit or process.
barometric draft regulator
counterweighted damper set so that variations in chimney barometric pressure will
cause the damper to open or close gradually to maintain a constant draft directly
upstream of the damper.
cran$case pressure regulator
automatic control device used to maintain the maximum pressure in the cran$case of
a reciprocating positive displacement! compressor.
draft regulator
device installed in the breeching between a fuel2fired appliance and the chimney to
control chimney draft.
dual2pressure regulator
upstream pressure regulator equipped with two controls, used in refrigerant suction
lines to provide free0e2up protection or for safety pressure relief.
evaporator pressure regulator
automatic valve or control device used to maintain the pressure, and thereby the
temperature in an evaporator above a predetermined minimum.
power2operated draft regulator
control that is capable of maintaining a constant pressure in a furnace under all normal
operating conditions. In addition, it includes a low2draft cutoff that shuts off the burner
when the draft falls below the preselected minimum value.
thermostatic regulator
evaporator pressure regulator that is sensitive to temperature.
reheat
application of sensible heat to supply air that has been previously cooled below the
temperature desired for maintaining the temperature of the conditioned space.
relative humidity
1. ratio of the partial pressure or density of water vapor to the saturation pressure or
density, respectively, at the same dry2bulb temperature, and barometric pressure of
the ambient air.
2. ratio of the mole fraction of water vapor to the mole fraction of water vapor saturated
at the same temperature and barometric pressure.
relay
1. electrical mechanism which uses the current in a control circuit to open or close
electric contacts.
2. fluid liquid or pneumatic! device that uses variations in fluid pressure to actuate final
control devices.
#. thermal relay.
reversing relay
relay designed to reverse the direction of current flow or of function, on actuation.
time2delay relay
relay whose activation is delayed for a predetermined period of time. It may be either
time2delay opening %7F! or time2delay closing %7C!.
voltage relay
1. relay that responds to a predetermined voltage.
2. device that is voltage sensitive with the ability to sense between two or more
voltage levels to operate a set of contacts.
reliability
1. mathematical probability that a device will perform its ob"ective adequately for the
period of time intended under the operating conditions specified.
2. probability that a device will function without failure over a specified time period or
amount of usage. &ee accuracy; precision; repeatability.
#. probability that an instrumentPs repeatability and accuracy will continue to fall within
specified limits.
rep
empiri$a# !nit of resistan$e to water-)apor f#ow thro!'h a materia# or $onstr!$tion% One
rep 0 one ho!r ⋅ s,!are foot ⋅ in$h mer$!ry press!re differen$e "etween the two
s!rfa$es per 'rain *a)oird!pois+ water )apor *h6ft26in% H'2'r+% *.he resistan$e may "e
stated in other !nits $onsistent with this )a#!e%+ .he rep is the re$ipro$a# of the perm% It
is not an SI !nit%
repeatability
1. closeness of agreement among repeated measurements of the same variable under
the same conditions.
2. closeness of agreement among consecutive measurements of the output for the
same value of input approaching from the same direction. Compare accuracy;
precision; reliability.
resistance
1. property opposing movement of material, or flow of energy, and involving loss of
potential voltage, temperature, pressure level!.
2. property of an electric circuit or of any ob"ect used as part of an electric circuit which
determines for a given current the rate at which electric energy is converted into heat
or radiant energy, and which has a value such that the product of the resistance and
the square of the current gives the rate of conversion of energy.
#. thermal resistance. &ee electrical resistance; thermal resistance.
resonance
condition of high vibration response. %he exact resonance of a system in forced
vibration exists when any change, however small, in the frequency of excitation causes
a decrease in the response amplitude; i.e., when the driving frequency equals the
natural frequency.
resonance frequency
frequency at which resonance exists. Fften called the natural frequency.
resource energy impact
product of an energy resource includes application of 186! anticipated to be used in
providing fuel or energy to a building site, multiplied by a 1I6 for that particular form of
energy resource. %otal resource energy impact is the sum of all resource energy
impacts for a building pro"ect.
resource impact factor 1I6!
multipliers applied to fuel and energy resources required by a building pro"ect to permit
a quantitative evaluation on the economy of those resources resulting from the
selection of on2site fuel and energy forms. 4vailability, social, economic, environmental,
and national interest issues are considered.
resource utili0ation factor 186!
multiplier applied to the quantity of fuel or energy delivered to a building site, which
provides a quantitative estimate of the energy resources consumed in providing that
fuel or energy. Eariant multipliers account for the burden of processing, transporting,
converting, and delivering fuel or energy from the point of extraction to the building site.
respirable particles
particles small enough to be inhaled into a nonciliated portion of the lung. >ea$
deposition of respirable particles occurs within the si0e range of ,.2 to (., micrometres.
>articles greater than 1, micrometres aerodynamic diameter are not respirable.
respiration
1. production of carbon dioxide and heat by ripening of perishables in storage.
2. breathing process of animals.
retrofit
modification of existing equipment, systems, or buildings to incorporate improved
performance, updated operation, or both. 7erived from retroactive refit.
retrofit pro"ect
modification, in factory or field, of existing equipment, systems, or buildings to
incorporate improved performance or operation.
return
pipe or duct to carry fluid bac$ to the source.
reverberation
persistence of sound in an enclosed space after the sound source has stopped.
reverberation time
time for sound energy to decay -, decibels.
16I radio frequency interference!
interference from sources of energy outside a system. Compare =AI.
ripple
alternating current component from a direct2current power supply arising within a power
supply.
rotating blac$outs electric!
process of deliberately interrupting preselected loads from a power system, as a
nonroutine remedy of energy management implemented through transmission
supervision and substation automation, on a substation bus or distribution feeder basis
in a sequentially timed pattern for the purpose of matching demand to temporarily
limited supply.
rupture dis$ pressure relief device; pressure2limiting device!
valve or rupture member designed to relieve excessive pressure by mechanical failure
of the dis$.
12value thermal resistance!
1% ,!antity determined "y the temperat!re differen$e( at steady state( "etween two
defined s!rfa$es of a materia# or $onstr!$tion that ind!$es a !nit heat f#ow rate
thro!'h !nit area *R 0 ⊗T2q+% .he re$ipro$a# of therma# $ond!$tan$e%
2. measure of the acoustical absorption properties of a room; the average absorption of
all the surfaces in a room times the total surface, divided by the average reflection.
sabin
dimensionless unit of acoustical absorption, equal to the equivalent sound absorption of
one square foot of a surface of unit absorptivity i.e., 1 ft2 of surface that absorbs all
incident sound energy!.
safety interloc$
1. device to indicate the physical state of a required operational condition and to furnish
proof to the primary safety control circuit.
2. arrangement to ma$e a system inoperable when an improper or unsafe condition
exists.
salinometer
hydrometer calibrated in salt concentration.
saponification
process of converting chemicals into soap, which involves the al$aline hydrolysis of an
oil or fat or the neutrali0ation of a fatty acid.
saturation
condition for coexistence in stable equilibrium of a vapor and liquid, or a vapor and solid
phase of the same substance. 4s an example, steam over the water from which it is
being generated. &ee vapor pressure.
saturation deficiency
dimensionless difference between the humidity ratio of an air sample and the saturation
humidity ratio of air at the same temperature and pressure.
scale inhibitor
substance added to water used in condensers, boilers, piping, and cooling towers to
prevent or minimi0e the formation of insoluble deposits.
scfm
standard cubic feet per minute.
scraper ring
piston ring of special section, designed to prevent oil from the cran$case entering the
cylinder head.
scrubber air washer!
1. system to reduce noxious substances from a flowing stream, as in chimneys, or
process discharges.
2. device for reducing the CF2 content of a controlled atmosphere storage room.
regenerative scrubber
scrubber in which the active reagent can be regenerated.
tower scrubber
vertical vessel filled with plates or suitable pac$ing, through which scrubbing fluid
flows upward through the liquid, separating entrained liquids or solids from the gas.
seal
device to prevent the passage of a gas or liquid into or out of a pipe, container, or along
a shaft.
bellows seal
mechanical seal of flexible corrugated metal bellows with one end attached to a ring
pressed against the shoulder of the shaft, the other end to a disc pressed against the
housing.
labyrinth seal
device consisting of a series of grooves, fins, etc. machined into or fitted onto a shaft,
piston, pac$ing piece, etc., to prevent lea$age of a fluid.
mechanical seal
shaft seal with small enough clearance between moving parts to provide pressure
tightness between the inside and outside of a compressor or pump.
rotary seal
shaft seal in which a ring or collar encircling the shaft is held against the housing of the
shaft.
shaft seal
1. mechanical system of parts for preventing fluid lea$age between a rotating shaft and
a stationary cran$case.
2. rubbing seal or stuffing box used to prevent fluid lea$age between the shaft and
bearing of a compressor or other fluid2moving device.
sealed absorption system
unit in which all refrigerant2containing parts are made permanently tight by welding or
bra0ing.
&==1
seasonal energy efficiency ratio.
semiconductor
class of substances having an electrical conductivity intermediate between those of
metals and insulations at ordinary temperatures.
sensor
1. device or instrument designed to detect and measure a variable.
2. device placed in a medium to be measured that has a change in output signal related
to a change in the sensed medium.
remote sensor indication
1. indication located away from the actual sensing location.
2. indication of position or condition of remotely located devices. 9ote: 1emote
indication may be over direct wire, other types of interconnecting channels such as
carrier2current or microwave, or by mechanical means.
#. meter or gage at a point remote from the point of measurement.
separator filter
vessel that removes solids and entrained liquid from a liquid or gas stream, using a
combination of a baffle or a coalescer with a screening filtering! element.
sequence
1. to put a set of symbols into an arbitrarily defined order, i.e., to select 4 if 4 is greater
than or equal to I, or select I if 4 is less than I.
2. arbitrarily defined order of a set of symbols, i.e., an orderly progression of items of
information or of operation in accordance with some rule.
sequencer
instrument that provides sequence control.
service water heating
heating water for domestic or commercial purposes other than space heating.
setbac$
1. reduction of heating or cooling during hours when a building is unoccupied, or during
periods when lesser demand is acceptable.
2. intentional depression of the control point by means other than ad"ustment of the
scale setting.
set point
1. in process control systems, a fixed or constant command for a relatively long time.
2. point at which the desired value of the controlled variable is set.
set pressure
pressure level at which a pressure2relief device is set to operate; the value mar$ed on
the valve or indicated on the switch.
short2cycling
excessive frequency of starting and stopping in an operating system.
shrin$ disassembly
process of dismantling hollow members bushings, sleeves, etc.! with the inner
component cooled so that it can be extracted from its housing.
sic$ building sic$ building syndrome!
building in which the indoor air quality is unacceptable to a substantial ma"ority of
people exposed. 9ote: Eolatile organic compounds various types! are present in
concentrations sufficient to act synergistically on many occupants, resulting in a sic$
building syndrome, usually when concentrations are too high. %his syndrome does not
conform to a particular illness and is difficult to trace to a specific source. &ee indoor air
quality; volatile organic compounds EFC!.
sight glass
transparent tube or window bullPs eye! used to indicate the liquid level in a boiler, tan$,
bearing, and similar fluid2containing equipment.
signal converter
device that changes one set of codes, modes, sequences, or frequencies to a different
set.
analog to digital converter
device that converts a signal that is a function of a continuous variable into a
representative number sequence digital format!.
digital2to2analog converter
1. device which transforms digital data into analog data.
2. in power2system communications, a circuit or device whose input is information in
digital form and whose output is the same information in an analog form.
#. in data processing, a device that converts an input number sequence into a
continuous variable.
silencer
device or unit installed in air duct systems to control air noise in the duct, or to control
discharge noise.
&I units
Ce &ystUme International dP8nitVs; the international agreement on the metric system of
units.
slime
visible and tangible mucous layer of microbial colonies spread over a surface.
sludge
product of decomposition of oil resulting from impurities, moisture, or chemical reactions
and favored by excessive temperature. &ludge may be mushy, gummy, or hard.
slugging
effect produced by droplets of liquid refrigerant or oil, or a mixture of both that reach the
cylinder of a compressor.
slurry
suspension of a solid in a liquid. &ee ice slurry.
smudging
blac$ mar$s on ceilings and air outlets, generally caused by dirt particles suspended in
the room air. %his dirt is entrained in the mixed airstream and is deposited on the ceiling
and outlet.
snow gun snow ma$er!
apparatus that can produce and shoot artificial snow over a long distance; used to ma$e
or improve a s$i area.
snubber pulsation suppressor
restrictor placed in the liquid or vapor line to suppress pulsating or fluctuating
pressures.
softening point
temperature at which a solid loses rigidity or consistency in a standardi0ed test
procedure.
solar collector
device designed to absorb incident solar radiation and to transfer the energy to a fluid
passing through it.
concentrating collector
solar collector which uses reflectors, lenses, or other optical elements to concentrate
radiant energy by passing it through an aperture onto an absorber, the surface area of
which is smaller than the aperture area.
flat2plate collector
nonconcentrating solar collector in which the absorbing surface is planar and
approximately equal in area to the aperture.
nonconcentrating collector
solar collector in which the absorber heat flux is not greater than the solar irradiance
across the aperture area. It may or may not contain optical elements to direct the
radiant flux onto the absorber.
solar collector absorber
part of the solar collector that receives the incident radiation energy and transforms it
into thermal energy. It may possess a surface through which energy is transmitted to
the transfer fluid; however, the transfer fluid itself can be the absorber.
solar collector aperture area
maximum pro"ected area of a solar collector through which the unconcentrated solar
radiant energy is admitted.
solar collector cover
material covering the aperture to provide thermal and environmental protection.
solar collector drain bac$
system in which the collector fluid is allowed to drain bac$ to storage whenever solar
energy is not being collected, i.e., when the fluid circulating pump is not operating.
solar collector drain down
system in which the collector fluid is drained from the system under prescribed
circumstances.
solar collector gross area
maximum pro"ected area of the complete collector module including integral mounting
means.
solar collector instantaneous efficiency
ratio of the energy removed by the transfer fluid per unit of collector area to the total
solar radiation incident on the collector per unit area aperture or gross! during a test
period for which the condition of the test corresponds to the steady state or quasisteady
state.
solar collector loop heater
heater installed within the collector loop when testing the solar domestic water heating
system with a nonirradiated array.
solar collector tilt angle
angle between the hori0ontal plane and the plane of the collector aperture.
solar collector transfer fluid
primary transfer fluid
fluid that flows through a solar collector.
secondary transfer fluid
fluid that flows through a condenser as a coolant.
solar compensator
1. device which ta$es into account the effect of the sunPs radiation on a temperaturesensing
element.
2. device that will reset the control point of the space to compensate for changes in sun
load. &ee control.
solar constant
solar radiation incident on a surface normal to the sunPs rays outside the earthPs
atmosphere at a distance from the sun equal to the mean distance between the earth
and the sun. Its value is approximately '## Itu.hO ft2 1#-/ K.m2!.
solar energy
radiant energy originating from the sun. 4pproximately **G of solar energy lies
between wavelengths of #,, and #(,, nanometres.
solar energy source
source of thermal, chemical, or electrical energy derived from conversion of incident
solar radiation.
solar energy system
configuration of equipment and components used to absorb, convey, store, convert, and
distribute the energy from the sun.
solar irradiance
1. solar radiation.
2. rate at which solar energy is received, per unit area. &ee also irradiance.
solar noon
instant at which the sun reaches its highest point on the hori0on at any given location.
solar2optical properties
spectral, radiant, or luminous transmittance, reflectance, and absorptance within the
range of wavelengths characteri0ing solar radiation, i.e., #,, to #,,, nanometres.
solar time
time of day as indicated by the apparent position of the sun. Compare true solar time.
true solar time
local standard time ad"usted by the equation of time determined from an astronomical
almanac! and the longitude correction four times the difference between the standard
longitude of the observerPs time 0one and the observerPs actual longitude!. 4 time
reference used to compute the apparent position of the sun.
soldering
general term for hot "oining of metals by adhesion to both surfaces of a melted alloy a
solder!.
soft soldering
hot "oining operation in which the melting temperature of the filler metal is lower than
+,,)6 '(,)C!.
solid2state device
electronic device made with semiconductor components.
solubility
quantity of dissolved substance solute! which is contained in a unit quantity of
saturated solution at a given temperature and pressure.
solute
substance which is dissolved in another.
solvent
substance capable of dissolving another substance.
sorbate
substance absorbed by or adsorbed on a sorbent.
sorbent
material which extracts one or more substances present in an atmosphere or mixture of
gases or liquids with which it is in contact, due to an affinity for such substances.
sorption
general term covering both absorption and adsorption.
sound attenuation noise reduction; sound damping; sound deadening!
process in which sound energy is absorbed or otherwise diminished in intensity.
sound decay rate
rate at which the sound pressure level in an enclosed space decreases after the sound
source has stopped. It is measured in decibels per second.
sound insulation
acoustical treatment of constructions and equipment such as fan housings, supply
ducts, space enclosures, for isolation of vibration or to reduce transmitted noise.
sound level
magnitude of a sound or a noise, usually determined by measuring the amplitude of
variations in the sound pressure expressed in decibels.
sound power level !
air"orne power meas!red in de$i"e#s% It is the "ase 1/ #o'arithm of the so!r$e power
o!tp!t w( m!#tip#ied "y 1/( and referen$ed at 1/− 12 4 *1 p4+% Or: Lw 0 1/ #o'*w21/− 12+
0 1/ #o' w < 12/ d1
sound pressure level "
defined as Cp 5 2, log p N *' dI
where referen$e press!re 0 2/ 9a
speech interference level &IC!
average of the sound pressure level measured in the three octave bands centered at
(,,, 1,,,, and 2,,, hert0.
specification
precise statement of a set of requirements to be satisfied by a material, product,
system, or service that indicates the procedures for determining whether each of the
requirements is satisfied. 9ote: It is desirable to express the requirements numerically
in terms of appropriate units, together with their limits.
specific gravity
ratio of the mass of a given volume of a substance to the mass of an equal volume of
water, usually at ')C. Fbsolete term. 8se density.
specific heat
ratio of the quantity of heat required to raise the temperature of a given mass of any
substance one degree to the quantity required to raise the temperature of an equal
mass of a standard substance one degree ?usually water at (*)6 1()C!@.
specific humidity
ratio of the mass of water to the total mass of a moist air sample.
specific volume &E!
volume of a unit mass of a material. 8sually expressed in cubic feet per pound cubic
metres per $ilogram!. %he reciprocal of density.
spinning reserve electric!
reserve generating capacity connected to the utility bus and ready to ta$e load.
spool piece
piece of pipe with flanges on both ends that is inserted into a pipeline in place of a valve
or instrument.
spray dec$
overhead bun$er where air is cooled and circulated by brine sprays.
spray pond
system for lowering the temperature of water by conductive and evaporative cooling of
the water in contact with outside air. Kater to be cooled is sprayed by no00les into the
air above a pond of water and allowed to fall by gravity into it.
spring range
1. range through which the signal applied must change to produce total movement of
the controlled device from one position to another.
2. difference between the start and finish pressure on a pneumatic operator.
stability
1. for a feedbac$ control system or element, the property such that its output is
asymptotic, i.e., will ultimately attain a steady state within the linear range and
without continuing external stimuli. 6or certain nonlinear systems or elements, the
property such that the output remains bounded, e.g., in a limit cycle of continued
oscillation, when the input is bounded.
2. general! property of a system or element by virtue of which its output will ultimately
attain a steady state.
stac$
1. portion of the exhaust system downstream of the draft diverter, draft hood, or
barometric draft regulator.
2. vertical train of a system of soil, waste, or vent piping extending through one or more
stories.
#. an organi0ed set of things fitting or resting one over another in a regular fashion.
stac$ effect chimney effect!
movement of air or other gas in a vertical enclosure e.g., duct, chimney, building!,
induced by the density difference between the air or other gas in the enclosure and the
ambient atmosphere. 9ote: &tac$ effect is a significant concern in heating system
design for tall buildings in cold climates.
stac$ing density
density to which a product can be stac$ed, ta$ing into account sufficient free space
around the product for proper cold air circulation.
stand2alone system energy!
energy management system that performs all control functions without direction from
any other unit.
standard
in 4&<14=, a document that defines properties, processes, dimensions, materials,
relationships, concepts, nomenclature, or test methods for rating purposes.
rating standard
standard that sets forth a method of interpreting the results of tests of individual units,
at specified conditions, in relation to a product manufactured in quantity.
testing standard
standard that sets forth methods of measuring capacity, or other aspects of operation,
of a specific unit or system of a given class of equipment, together with a specification
of instrumentation, procedure, and calculations.
standard acceleration due to gravity
#2.1/' ft.s2 *.+,- -( m.s2!.
standard conditions
1. set of physical, chemical, or other variables of a substance or system which defines
an accepted reference state or forms a basis for comparison.
2. operating conditions of a refrigerating system corresponding to a standard such as
evaporating temperature, condensing temperature, subcooling temperature,
superheat.
standard ton conditions
conditions for comparing refrigerating systems are: ()6 R1()C! evaporation;
adiabatic compression of saturated gas; +-)6 #,)C! condensation; and +-)6 #,)C!
liquid to expansion valve.
standard cubic feet per minute scfm!
volumetric rate of flow of air at standard conditions ?dry air at /,)6 and 1'.-*- psia
2,)C and 1,1.#2( $>a!@. 8nder these conditions, air has a mass density of ,.,/( lb.ft#
1.2, $g.m#!.
standard rating
capacity in energy units per unit time based on tests performed under standard
conditions.
standards review
study to determine whether a standard is valid, or if it needs to be revised and the
nature of the revisions.
startup
procedure to start a prime mover and supporting auxiliaries, including synchroni0ing
and loading the generator.
state
condition or stage in the physical being of something.
change of state
1. change from one of the three phases, solid, liquid, or gas, to another.
continued on next page!
2. occurrence in a remote system causing the contact of an alarm or status device to
move from one of two possible positions to the other, e.g., into alarm, causing the
contact of an alarm device to close or return to normal causing the contact to open.
corresponding state
states of fluids when the ratios of their state variables pressure, temperature! to the
critical values of these variable have equal values, respectively.
critical state critical point!
state of a substance at which the corresponding physical properties pressure,
volume, temperature! of liquid and gas are identical.
equation of state
thermodynamic expression relating the volume, pressure, and temperature of a given
substance.
gaseous state
one of the three states of matter characteri0ed by the greatest freedom of molecules
and the lac$ of any inherent fixed shape or volume.
intermediate state
thermodynamic state, exhibited by all type I superconductors and certain type II
superconductors, in which a specimen of finite demagneti0ing coefficient divides itself
into macroscopic domains that are alternatively in the Aeissner state and either the
normal state for type I superconductors! or the mixed state for type II
superconductors!.
liquid state
one of the three states of matter characteri0ed by limited freedom of molecules and by
substantial incompressibility. &ee also liquid.
solid state
1. one of the three states or phases of matter characteri0ed by stability of dimensions,
relative incompressibility, and molecular motion held to limited oscillation.
2. device, circuit, or system whose operation is dependent on any combination of
optical, electrical, or magnetic phenomena within a solid. &pecifically excluded are
devices, circuits, or systems dependent on the macroscopic physical movement,
rotation, contact, or noncontact of any combination of solids, liquids, gases, or
plasmas.
steady state
state of a system in which movement of matter or energy phenomena are ta$ing
place, when the various physical phenomena are independent of time.
superconducting state superconductive state!
low2temperature thermodynamic state in which a superconductor exhibits the property
of superconduction.
triple2point state
physical state temperature at which solid, liquid, and gaseous phases exist in
equilibrium.
unsteady state
state of a system when the various physical quantities at any location vary randomly.
state diagram
diagram representing, in a system of suitable coordinates, the thermodynamic
equilibrium states of a substance.
static suction
same as static suction head, but a negative value; measured at the inlet to the pumping
device.
static suction head
same as static discharge head, but measured at the inlet to the pumping device. It is a
positive value. &ee static suction lift.
static suction lift
vertical distance between the pump centerline and the source of liquid below the pump.
steam
water in the vapor phase.
dry saturated steam
steam at the saturation temperature corresponding to the pressure and containing no
liquid water in suspension.
superheated steam
steam at a temperature higher than the boiling temperature corresponding to the
pressure at which it exists.
wet saturated steam
steam at the saturation temperature corresponding to the pressure and containing
water particles in suspension.
steam exhaust
steam discharged from a machine or system.
steam quality
fraction of vapor in a mixture of liquid and vapor, expressed as a percentage by weight.
steam separator
device used to remove moisture from steam after it leaves the boiler.
steam trap
device for allowing the passage of condensate and preventing the passage of steam, or
for allowing the passage of air as well as condensate. &ee trap.
float and thermostatic steam trap
trap that relies on the density of water to raise a float2and2lever mechanism to operate
a valve head. It discharges condensate as it forms and enters the trap body. It
includes a thermostatic balance pressure or bimetallic air vent to allow free passage of
air on start2up, and discharges incondensible gases reaching the trap during
operation.
inverted buc$et steam trap
trap in which the inlet is channeled to the bottom of the trap body so that the
condensate enters underneath the inverted buc$et. 4 small hole in the top of the
buc$et helps discharge incondensible gases and entrapped air. %he outlet from the
trap is at the top, and as long as the trap is filled with steam, it floats in the condensate
and $eeps the outlet closed. %he valve opens when the trap fills with condensate,
sin$s, and discharges the condensate into the return line.
liquid2expansion steam trap
trap with an ad"ustable bellows and steel valve head located downstream of the steam
system. It operates on temperature rise, with the set point ad"ustable from the outside.
continued on next page!
It discharges at a fixed temperature for protection from free0ing and for high2capacity
venting requirements.
thermodynamic steam trap dis$ trap!
trap constructed with a cap containing a steel dis$, which fits against a flat seat.
Condensate, discharging at close to saturation temperature, increases in velocity and
draws the dis$ down toward the seat, due to the lower pressure caused by the
increased velocity Iernoulli effect!. Condensate discharging from high to low
pressure flashes off, and creates the closing pressure above the dis$ within the cap.
4s this flash steam condenses, pressure is dissipated, and the cycle repeats. %he trap
has limited air2venting capabilities.
thermostatic balanced pressure steam trap
trap installed on the discharge side of a heating unit and designed to pass air freely on
start2up, and condensate at a subcooled temperature; but to prevent steam vapor
passing into the return. It can have a bellows or encapsulated metallic diaphragm
containing a small quantity of volatile liquid. 4t the bottom of the diaphragm or bellows
is attached a hardened, self2centering valve head operating on the pressure side of
the valve seat. 4t ordinary temperatures and atmospheric pressure, the valve is fully
open to permit free passage of air and cold condensate. %he trap discharges at a fixed
temperature below that of steam saturation temperature and closely follows the steam
pressure.temperature curve.
thermostatic bimetallic steam trap
trap installed where low2temperature discharge is required. It incorporates a bimetallic
element that, when heated, deflects and causes a downstream valve head to be
drawn up, closing the orifice. It discharges air and cold condensate freely on start2up.
It is installed only where a high waterlogging effect is tolerated.
upright buc$et steam trap open2top buc$et trap!
trap with a buc$et that is usually hinged, so when condensate enters in sufficient
quantity to fill the buc$et and it sin$s, the downward motion opens a valve. Kater is
then discharged into the return line through a tube which extends almost to the bottom
of the buc$et. 4fter the discharge, the buc$et returns to its normal position. 9ow
seldom manufactured.
sterili0ation
heating foods or other materials to $ill microorganisms, usually to a temperature of
212)6 1,,)C! or higher. Compare pasteuri0ation.
stoichiometric reaction
having the precise mass relationship of the elements in a chemical compound; or
quantities of reacting elements or compounds! in the same mass relationship as the
theoretical combining mass of the elements involved. &ee combustion.
storage cell
elementary unit of computer memory storage, e.g., binary cell, decimal cell.
storage cycle thermal storage!
complete charge and discharge of a thermal storage device.
storage disease
in"ury to produce occurring during storage. Compare cold in"ury.
stratification
division into a series of layers, as with thermal gradients across a stream.
stream splitter water cooler!
test device used to establish the percent spill.
stress
force applied to a structural member, component, or assembly per unit of its area. &ee
also mechanical properties, pressure vessel.
hoop stress circumferential stress!
stress imposed in the wall of a cylindrical tube in the circumferential direction by
internal pressure.
longitudinal stress
tensile stress in an axial direction in tubular pipe or in vessels.
stripping column
section of a distillation column located above or below the inlet of liquid to be distilled. In
this section, the concentration of volatile constituents is reduced.
stuffing box
1. pac$ing gland surrounding a shaft, stem, or rod to prevent lea$age.
2. device for use where a cable passes into a "unction box or other piece of apparatus
designed to render the "oint watertight.
subbase
part containing terminals and switches, to which a thermostat is attached. It may also
contain other auxiliary components.
subcooled liquid
liquid whose temperature is lower than the condensation temperature at its given
pressure.
sublimation
change of state directly from solid to gas without passing through a liquid phase.
sublimation front sublimation interface!
during the sublimation process, the dividing interface within the substance between a
region which is fully hydrated and fro0en and a region which is nearly completely dry.
sharp sublimating front
refers to a distinct and sharp transition on both sides of the sublimating front.
submetering electric!
separated metering of energy purchased from a utility by a customer for distribution to
his tenants through privately owned or rented meters.
suction head
positive head on a pump inlet when the source of liquid supply is above the pump
centerline. &ee also head.
dynamic suction head
positive static suction head minus friction head and minus velocity head.
net positive suction head 9>&<! available!
head at the pump inlet greater than the vapor pressure expressed as head! at the
operating temperature of the liquid being pumped.
suction inlet
port through which gas enters.
suction lift
combination of static suction lift and friction head in suction piping when the source of
liquid is below the pump centerline.
dynamic suction lift
sum of suction lift and velocity head at the pump suction when the source is below the
pump centerline.
suction line
1. tube or pipe which carries the refrigerant vapor from the evaporator to the
compressor inlet.
2. tube or pipe which connects any line from a store to the suction side of a pump.
double2riser suction line
arrangement of two vertical suction lines in order to ensure oil entrainment or carryover
even at minimum load.
suction side
side of a compressor connected to low pressure, or the outlet side of an evaporator.
suction stro$e
movement of a piston in a compressor or engine cylinder during which fluid is drawn
into the cylinder.
superchilling
chilling a product to a temperature very near or sometimes below its free0ing point.
superconduction superconductivity!
property of certain substances characteri0ed by their 0ero dc electrical resistivity for low
currents when their temperature is sufficiently low.
superconductor
1. substance exhibiting or capable of exhibiting superconduction.
2. %ype I: superconductor for which the Aeissner state and the normal state can coexist
in thermodynamic equilibrium.
#. %ype II: superconductor capable of existing in the mixed state.
supercooling
cooling a substance below the normal free0ing point without solidification.
supercritical
state of fluids at pressures and temperatures above their critical values. 4lso used,
loosely, and especially for helium, for the state of the liquid at pressures exceeding the
vapor pressure.
superfluidity
property of helium <e II! flowing without viscous resistance through thin capillaries or
narrow slits.
superheat
extra heat in a vapor when at a temperature higher than the saturation temperature
corresponding to its pressure.
expansion valve superheat
difference between the temperature of the external bulb and the corresponding
system refrigerant saturation temperature at the bulb location.
expansion valve superheat change
change in superheat of a thermostatic expansion valve required to open the valve a
predetermined amount.
expansion valve static superheat
superheat at which the valve begins to open.
specific superheat
1. superheat in a unit quantity of fluid.
2. difference in specific enthalpies of a pure condensable fluid between vapor at a given
temperature above saturation and vapor at the dry saturated state at the same
pressure.
superheated vapor
vapor at a higher enthalpy than the enthalpy at saturation.
superheater
1. heat exchanger used on flooded evaporators, where hot liquid on its way to enter the
evaporator is cooled by giving up heat to both dry and superheat the wet vapor
leaving the evaporator.
2. group of tubes in a boiler which absorbs heat from the products of combustion to
raise the temperature of the vapor passing through the tubes above the temperature
corresponding to its pressure or saturation temperature.
supersaturation
1. condition of metastable equilibrium in which a vapor is at a pressure higher than the
saturation pressure corresponding to its temperature.
2. condition of metastable equilibrium in a solution where the solute remains dissolved
at a temperature lower than the initial solidification temperature.
surface effect
effect caused by entrainment of secondary air when an outlet discharges air directly
against, or parallel to, a wall or ceiling.
surface tension
forces in a liquid surface that cause it to remain continuous by the attraction between
molecules.
suspended ceiling hung ceiling!
suspension of the furring members below the structural members of a ceiling.
swaging tool
tool to expand or Bbell outD the end of a tube to fit over another tube of the same
diameter, or over a special fitting to accept such a shape.
sweating
condensing of moisture on a surface.
sweep rate fan!
time rate change of frequency, df.dt, where f is frequency and t is time.
swept volume
piston displacement.
switch
device for ma$ing, brea$ing, or changing the connections in an electrical or pneumatic
circuit. &ee also computer switch.
changeover switch selector switch!
switch for changing a circuit from one system of connections to another.
double pole switch
1. contact arrangement of two separate contacts, i.e., two single2pole contact
assemblies.
2. two isolated contacts operated in unison.
double throw switch
three2contact switch that can change the circuit connections from one to the other of
its two operating positions.
electronic switch
switch without mechanical contacts.
1. electronic device containing three or more layers of B>D or B9D type semiconductor
material and no moving parts, e.g., &C1, &C&, Iipolar %ransistor, 6=%.
2. semiconductor device designed to operate in one of two modes F9 or F66! and
used to interrupt an electronic circuit.
external interrupt switch!
1. device designed to disconnect load from a power source or distribution center
under an overload or short2circuit condition.
2. interrupt generated by an alarm point going into alarm. &ee also interrupt device.
float switch
device in which a float ball, through variations on the level of liquid, operates one or
more sets of electrical contacts to activate or deactivate other controls or alarms.
limit switch
control to limit some function. Fnce tripped, it should require manual reset. =xamples
are pressure limit switches which shut off the fuel burner when the steam pressure
reaches a predetermined point; similarly, temperature limit switches for hot water and
warm air. &ee also control.
manual switch
1. device for interrupting or changing the path of electric current or mass flow by a
physical means.
2. device used to manually turn on or interrupt an electric circuit.
mercury switch
glass tube partially filled with mercury. =lectrical contact is established when the tube
is tilted so that the mercury bridges the gap between contacts located at the same
end. %ilting in the opposite direction opens the circuit.
pneumatic2electric switch
control device that ma$es and.or brea$s an electrical circuit based on the level of a
pneumatic signal. %he device has an ad"ustable set point and optional ad"ustable
differential.
pressure switch pressurestat!
regulating or safety device actuated by change in pressure.
selector switch
1. manually operated multiposition switch for selecting alternative control circuits, e.g.,
heating, cooling, cycling fan, constant fan, etc.
2. switch arranged to permit connecting a conductor to any one of a number of
conductors.
#. manually operated multipositioning switch for selecting alternative control circuits.
single2pole switch
switch in which a pair of mating contacts serves only one line.
single2throw switch
electric switch that can be opened or closed.
thermostatic switch
1. device within an electric controller for completing or interrupting an electrical circuit
in response to a temperature change.
2. switch actuated by temperature.
system
1. organi0ed collection of parts united by regular interaction. &ee air2conditioning
system; cooling system; heating system; heat pump; refrigerating system; thermal
insulation system.
2. heating or refrigerating scheme or machine, usually confined to those parts in contact
with a heating or refrigerating medium; an arbitrarily chosen group of materials and
devices set apart for analytical study. &ee also air2conditioning system; control
system; defrosting system; expert system; heat exchanger; heating system;
refrigerating system; water system.
air agitating system
combination consisting of a blower, distributing piping, and flexibly connected fittings
for delivering air to the water in ice cans to agitate the water and promote production
of clear ice.
auxiliary electrical system
assembly of electrical energy2using components necessary to ma$e a main energy
conversion function; such as a power burner, induced or forced2draft blower motor,
ignition system but not a resistance heating element supplied by the manufacturer as
part of a water heater!.
brine spray system
refrigerating system for cooling by a mist of spray or brine.
building automation system I4&!
centrali0ed control and.or monitoring system having several forms. Iasic I4& may be
a computer2based central for an energy management system =A&! providing
operator interface terminal and alarm display with optional audible and.or printout.
I4& may further support networ$s of remote 77C, life safety, and.or securityintelligent
processors. I4& may have monochromatic or color graphic monitors with
printers for alarm, summary, and custom reports. I4& has one or more operator
stations.
central fan system
mechanical indirect system of heating, ventilating, or air conditioning, in which air is
treated or handled by equipment located outside the rooms served, usually at a
control location, and is conveyed to and from the rooms by means of a fan and a
system of distributing ducts.
closed system
heating or refrigerating piping system in which circulating water or brine is completely
enclosed, under pressure above atmospheric, and shut off from the atmosphere,
except that the expansion tan$ could be open to the atmosphere. &ee also water
system.
closed water system
system having a chec$ing device installed in the service pipe. 9ote: 4 chec$ valve,
bac$flow preventer, or pressure2reducing valve would create a closed system.
cold air distribution system
system that uses a primary air supply with a temperature range of approximately ', to
(,)6 1, to 1()C!. 9ote: %ypically used with ice storage systems. Compare cold water
distribution system.
cold water distribution system
system that uses a primary chilled water supply with a temperature range of
approximately #' to ',)6 1 to 1,)C!. 9ote: %ypically used with ice storage systems.
Compare cold air distribution system.
combined heat and power C<>! system
system combining power production with the use of a lower quality heat byproduct of
power generation for district heating.
commercial system
heating, cooling, or refrigerating system used in a commercial or business place.
community energy system
centrali0ed facility for generation and distribution of the heating and cooling needs of a
community, rather than individual heat or cold generators i.e., furnace or air
conditioner! at each residential, commercial, or institutional site.
consumerPs water system
all potable water piping, valves, fittings, and appurtenances on the premises side of
the service connection. It is the secondary component of a public water system.
cycle defrosting system
in household refrigerators and combination refrigerator2free0ers only, a system in
which the refrigerated surfaces of the general refrigerated compartments are
defrosted while maintaining nominal refrigerated food temperatures. 7efrost water is
disposed of automatically or collected in a container for subsequent manual removal.
diffusion2absorption system
refrigerating absorption system that, in addition to refrigerant and absorbent, also has
an inert medium such as hydrogen! to balance pressure in the various parts of the
refrigerating circuit.
downfeed system
see heating system.
duct system
series of ducts, elbows, and connectors to convey air or other gases from one location
to another.
energy management system =A&!
formal system of building energy conservation through all available means.
facility management system
building automation system within a building complex.
feedbac$ system
system that uses feedbac$.
forced2circulating system
heating, air2conditioning, or refrigerating system in which heating or cooling fluid is
circulated by a fan or pump.
gravity2circulating system
heating or refrigerating system in which heating or cooling fluid is circulated by the
forces induced by the differences in densities of cooler and warmer fluids in the
system or surrounding atmosphere.
industrial system
system used in the manufacturing or processing of material, such as ice2ma$ing
plants, cold2storage warehouses, ice2cream plants, dairy plants, pac$ing houses,
chemical plants, and other places of similar industrial enterprise.
integrated system
1. system in which many subsystems of a building are combined into a single
pac$age, e.g., fire, security, cloc$, and <E4C.
2. more than one building system, such as lights and air distribution, combined into a
common design.
isolated system
in thermodynamics, a system which can interchange neither matter nor energy with its
surroundings.
off2pea$ system
refrigerating or cooling system with control which normally avoids use of power during
pea$ load periods, usually requires means for storage of energy.
one2pipe steam system
piping system in which the condensable vapor withdrawn from the supply main
passes into a heating unit and returns as condensate to the same supply main.
open system
heating or refrigerating piping system in which the circulating water or brine return
main is connected to an open2vented elevated tan$ which serves as a reservoir to
accommodate expansion and contraction of the fluid, and as an inspection point for
the condition of the fluid. &ee also water system.
open water system
system having no chec$ing device installed in the service pipe. 9ote: Kater from the
consumerPs system is free to bac$flow into the main.
overhead system
heating, air2conditioning, or refrigerating piping system in which the supply main is
above the heating or cooling units supplied.
piping system
system to carry fluids, including pipe, flanges, bolting, gas$ets, valves, fittings, the
pressure2containing parts of other components such as expansion "oints, strainers
and devices which serve such purposes as mixing, separating, snubbing, distributing,
metering or controlling flow, and pipe2supporting fixtures and structural attachments. It
does not include pressure vessels, compressors or pumps, and heat exchangers
including coil type, but does include all connecting refrigerant and brine piping starting
at the first "oint ad"acent to such apparatus. It does not include support structures.
radial energy2distribution system
system of radial feeders extending outward from a centrally2located district energy
plant heating or cooling!. =ach feeder normally is comprised of one supply pipe and
one return pipe.
runaround system
regenerative2type closed secondary system in which a continuously circulated fluid
absorbs heat from the primary system fluid at one place and sends it to the primary
system fluid at another place.
serial energy2distributing system
system that connect clients in series. It requires only a single pipe connecting users to
the central plant; but each downstream user sees a successively lower supply
temperature.
servo system
combination of devices for controlling a source of power in which the output or some
function thereof! is fed bac$ and compared to some reference at the input, the
difference of this comparison being used to effect the desired control.
split system
1. system in which the heating and ventilating are accomplished by means of radiators
or convectors supplemented by mechanical circulation of air heated or unheated!
from a central point.
2. air2conditioning system with remote condenser or remote condensing unit.
#. system that serves more than one 0one.
thermodynamic system
in thermodynamics, a region in space or a quantity of matter bounded by a closed
surface in which thermal actions occur. %he surroundings include everything external
to the system, and the system is separated from the surroundings by the system
boundaries. %hese boundaries can be either movable or fixed, either real or
imaginary.
two2pipe system
piping system in which the fluid withdrawn from the supply passes through a heating
or cooling unit to a separate return main.
upfeed system
piping arrangement for a heating, air2conditioning, or refrigerating system, in which
cooling fluid is circulated through supply mains which are below the levels of heating
or cooling units they serve.
water system public water system!
system operated as a public utility that supplies potable water to the service
connection of the consumerPs water system. It is the primary component of a public
water system.
system analysis
examination of an activity, procedure, method, technique, or a business to determine
what must be accomplished and how the necessary operations may best be
accomplished.
system effects
conditions in a distribution system that affect fan and pump performance and related
testing, ad"usting, and balancing wor$.
tan$
receptacle, open or closed, for holding, transporting, or storing fluids. &ee also thermal
storage device.
balance tan$
reservoir for balancing pressures, levels, etc.
brine tan$
1. in an ice plant, a main free0ing tan$, in which cans are immersed while ice is being
produced.
2. in a brine2circulating system, a storage or balance tan$ for brine.
#. in domestic and commercial fields, a container surrounding the evaporator and
filled with brine for storing refrigerant or equali0ing temperature at various points of
the evaporator, especially an ice2cream cabinet.
brine expansion tan$ head tan$!
vented reservoir in a closed circulating brine system for the accommodation of volume
expansion of brine due to temperature change.
brine return tan$
reservoir in an open circulating brine system for storing brine at the pump suction and
for inspecting the condition and flow of brine.
buffer tan$
tan$ fitted into a circuit to dampen fluctuations in flow.
compression tan$
pneumatic cushioning device, operating at system pressure, which absorbs fluid
expansion as a result of temperature change and prevents unnecessary periodic
operation of the relief valve. Compare expansion tan$.
dip tan$
liquid2holding process vessel in which components to be treated can be immersed.
equali0er tan$
receiver fitted between the compressor suction line and the return lines of several
evaporators in parallel.
expansion tan$
partially filled tan$, operating at atmospheric pressure, at the top of a water system for
the accommodation of volume expansion and due to the contraction of water.
Compare compression tan$.
free0ing tan$
vessel holding low2temperature fluid for process free0ing.
head tan$
brine expansion tan$.
hot water storage tan$
tan$ used to store water that is heated externally.
ice2ban$ tan$ ice buildup tan$!
water cooling tan$ in which ice is allowed to build up on the evaporator tubes to
provide a reserve for cooling.
self2supporting tan$ structural tan$!
in marine liquefied gas ship carriers, a structural barrier forming a tan$ that can resist
the static and dynamic forces exerted by the cargo and is relatively independent of the
shipPs structure.
spray2wall tan$
liquid cooling tan$ whose walls are sprayed with chilled water.
water forecooling tan$
one in which inlet water is cooled prior to free0ing.
tap
manually operated device on the end of a pipe in a fluid supply system to enable
drawing off quantities of the fluid.
%7
temperat!re differen$e= ⊗t%
temperature
thermal state of two ad"acent substances that determines their ability to exchange heat.
&ubstances in contact that do not exchange heat are at the same temperature.
%emperatures are indicated on defined scales, such as $elvin and 1an$ine for absolute
temperatures, and Celsius and 6ahrenheit for ordinary temperatures.
absolute temperature thermodynamic temperature!
temperature as measured above absolute 0ero.
absolute 0ero temperature
0ero point on an absolute temperature scale. &ee $elvin temperature; 1an$ine
temperature.
ambient temperature
1. temperature of the medium surrounding an ob"ect. In a domestic or commercial
system having an air2cooled condenser, it is the temperature of the air entering the
condenser.
2. temperature of the medium, such as air, water, or earth, into which the heat of
equipment is dissipated.
#. for self2ventilated equipment, the ambient temperature is the average temperature
of the air in the immediate neighborhood of the equipment.
'. for air2or gas2cooled equipment with forced ventilation or secondary water cooling,
the ambient temperature is ta$en as that of the ingoing air or cooling gas.
(. for self2ventilated enclosed including oil2immersed! equipment considered as a
complete unit, the ambient temperature is the average temperature of the air
outside of the enclosure in the immediate neighborhood of the equipment.
apparatus dew point
dew2point temperature of the air leaving the conditioning apparatus, used
interchangeably with maximum average coil surface temperature required to produce
dew.
apparent temperature
temperature of an ob"ect as determined from the measured radiance.
autogenous spontaneous! ignition temperature
temperature of spontaneous ignition of a product in the absence of a flame,
determined under standardi0ed conditions.
autoignition temperature
see autogenous ignition temperature, the preferred term.
average temperature mean temperature!
arithmetic mean of temperatures measured at a given point during a given lapse of
time, or at a given time in various points of a space or body.
base temperature
temperature from which temperature departure is calculated. &ee degree2day.
blac$body equivalent temperature apparent temperature!
apparent temperature of an ob"ect as determined from the measurement of its
radiance and the assumption that it is an ideal blac$body with emissivity of 1.,.
boiling point
temperature at which the vapor pressure of a liquid equals the absolute external
pressure at the liquid2vapor interface.
Celsius temperature
temperature scale used with the &I system in which the free0ing point of water is ,)C,
the triple point is ,.,1)C, and the boiling point is 1,,)C. 6ormerly referred to as the
centigrade scale.!
centigrade temperature
use Celsius temperature.
cloud point
temperature at which a clear liquid becomes ha0y or cloudy due to the formation of
crystals or particles, when tested under standardi0ed conditions.
color temperature
temperature of a perfect radiator blac$body! that would emit the same relative
intensity at two wavelengths usually red and green lights! as the relative intensity
radiated by the sub"ect surface.
condensation point
temperature at which a vapor liquefies if the latent heat is removed at standard or
stated pressure. &ee also dew point; saturation temperature; boiling point.
condensing temperature
temperature of a fluid at which condensation occurs.
corrected effective temperature
effective temperature corrected by accounting for the effect of radiation. &ee also
operative temperature.
critical temperature
saturation temperature corresponding to the critical state of the substance at which
the properties of the liquid and vapor are identical.
critical temperature superconduction!
temperature below which, in the absence of all external influences, a substance
becomes superconducting.
cryotemperature cryogenic temperature!
temperature within a few degrees of absolute 0ero 2.2 H!.
Curie point
temperature above which a given ferromagnetic substance becomes paramagnetic.
design air temperature
air temperature which an <E4C system or apparatus is designed to maintain inside
design! or to operate against outside design!.
dew point
temperature at which water vapor has reached the saturation point 1,,G relative
humidity!. Compare frost point. 9ote: It is improper to refer to the dew point as the
temperature at which condensation starts to occur, because condensation at the dew
point requires removal of latent heat from the vapor to induce condensation, and this
can occur only if the vapor is cooled below the dew point.
differential temperature
1. in control terminology, the difference in temperature between the high event and the
low event.
2. difference in temperature existing between any two points or states when measured
on the same temperature scale.
discharge temperature delivery temperature!
temperature of compressed fluid as discharged from a fan or a compressor.
dry2bulb temperature
temperature of air indicated by an ordinary thermometer.
effective temperature
use operative temperature.
evaporating temperature
temperature at which a fluid vapori0es within an evaporator.
6ahrenheit temperature
temperature scale on which at standard atmospheric pressure, the boiling point of
water is 212)6 and its free0ing point is #2)6; absolute 0ero is R'(*.-*)6.
flue temperature
temperature of the flue gases leaving the boiler or furnace, and prior to any dilution
caused by draft control devices.
free0ing point
for a particular pressure, the temperature at which a given substance will solidify or
free0e upon removal of heat. Compare solidification point.
frost point
temperature at which visible frost forms on a surface being chilled.
heat pump balance point temperature
temperature at which the installed heat pump capacity is equal to the heat
requirement of the building.
ignition temperature ignition point; $indling temperature!
temperature at which a combustible material will unite with oxygen in the atmosphere,
and combustion will commence.
$elvin temperature
&I absolute temperature scale on which the triple point of water is 2/#.1- H and the
boiling point is approximately #/#.1( H 1 H 5 1)C!. %he $elvin is the fraction 1.2/#.1-
of the temperature of the thermodynamic triple point of water. &ee triple point.
magnetic temperature
as measured by a magnetic thermometer.
mean radiant temperature A1%!
uniform surface temperature of a radiantly blac$ enclosure in which an occupant
would exchange the same amount of radiant heat as in the actual nonuniform
environment.
operative temperature
uniform temperature of a radiantly blac$ enclosure in which an occupant would
exchange the same amount of heat by radiation plus convection as in the actual
nonuniform environment.
pour point
lowest temperature at which a fluid, such as an oil, will continue to flow when it is
cooled by standardi0ed procedures.
1an$ine temperature
absolute temperature scale conventionally defined by the temperature of the triple
point of water equal to '*1.-+)1, with 1+, divisions between the melting point of ice
and the boiling point of water under standard atmospheric pressure 1)1 5 1)6!. &ee
triple point.
room dew point
temperature in a space at which the water vapor reaches saturation.
saturation temperature
boiling point.
solidification point
temperature at which a liquid substance will solidify, but not necessarily crystalli0e, on
removal of heat usually at standard atmospheric pressure!. Compare free0ing point.
stac$ temperature
temperature of the flue gases entering the exhaust stac$ or chimney, after any
dilution.
standard ambient temperature
reference condition for the rating of equipment, usually -+)6 2,)C!.
suction temperature
temperature of the vapor drawn into the compressor inlet.
transition temperature
temperature below which a substance becomes superconducting in the presence of a
specified external influence e.g., a specified magnetic field!.
triple point
particular temperature and pressure at which three different phases of one
substances can coexist in equilibrium. Kater is an example of a substance that has a
well2$nown triple point.
wet2bulb temperature
temperature indicated by a psychrometer when the bulb of one thermometer is
covered with a water2saturated wic$ over which air is caused to flow at approximately
*,, ft.min '.( m.s! to reach an equilibrium temperature of water evaporating into air,
when the heat of vapori0ation is supplied by the sensible heat of the air. &ee
psychrometer; thermometer; dew2point depression.
temperature difference
difference between the temperatures of two substances, surfaces, or environments
involving transfer of heat.
arithmetic mean temperature difference
in a parallel flow or counterflow heat exchanger, arithmetic mean of the temperature
differences between the two fluids at both ends of the exchanger.
diffusion temperature difference
temperature difference between the air temperature at supply openings and design
outdoor temperature.
effective temperature difference
difference between the room air temperature and the supply air temperature at the
outlet in the room.
wet2bulb depression temperature difference
difference between dry2bulb and wet2bulb temperatures.
temperature difference %7! method
procedure used in design and system analysis to calculate flow of air, water, or steam!
from load, or to determine load when flow and temperature differential are $nown.
temperature fluctuation
variation of temperature around a mean value.
temperature gradient
temperature variation per unit distance or time along the heat flow path.
temperature profile
graph representing the distribution of temperatures in a plane section of a body or a
space, or over a period of time.
terminal
1. conductor point at which an electrical component may be connected to another
electrical component.
2. conducting element of an equipment or circuit intended for connection to an external
conductor.
#. device attached to a conductor to facilitate connection with another conductor.
'. point in a system or communication networ$ at which data can either enter or leave.
terminal element
means by which the energy from a system is finally delivered, e.g., registers, diffusers,
radiators, lighting fixtures, and faucets.
terminology
1. system of terms belonging to or peculiar to a science, art, or speciali0ed sub"ect.
Compare nomenclature.
2. a compendium of terms.
test method
definitive procedure that produces a test result. 9ote: 4ppropriate functions of a test
method are identification, measurement, or evaluation of one or more qualities,
characteristics, or properties of a material, product, system, or service.
primary test method
test procedure incorporating the preferred method of installing a test unit, and the
preferred test apparatus, that produces the desired reproducibility and accuracy.
primary2alternate test method
test procedure using an alternate method of installing a test unit, or an alternate test
apparatus, that produces reproducibility and accuracy equivalent to the primary test
method.
thawing
changing the solid phase of water, or fro0en moisture within a substance, to the liquid
phase by the application of heat.
dielectric thawing
process using dielectric heating with high voltage and high frequency or ultrahigh
frequency electric fields.
high2frequency thawing
dielectric thawing using suitable frequencies of a few megahert0 or higher.
ultrahigh frequency thawing microwave thawing!
dielectric thawing using frequencies of the order of thousands of megahert0 usually
2'(, A<0 or *1( A<0 in accordance with the International %elecommunication
8nion!.
therm
quantity of heat equivalent to 1,,,,,, Itu.
thermal absorptance
ratio of the radiant flux absorbed by a body to that incident on it.
thermal anomalies
heat loss characteristics of a structure that are not in accordance with intended design
characteristics.
thermal boundary resistance thermal contact resistance!
ratio of temperature difference to heat flux across the boundary between two distinct
media solid.solid or solid.fluid!.
thermal brea$ brea$er!
nonconducting frame around a door or window acting to retard heat flow.
thermal bridge
low thermal resistance path connecting two surfaces.
thermal comfort
condition of mind which expresses satisfaction with the thermal environment.
thermal conductance C2factor!
time rate of steady2state heat flow through unit area of a material or construction,
induced by a unit temperature difference between the body surfaces. 8nits of C are Itu.
hOft2O)6 or K.m2OH!. Compare thermal resistance.
surface2film thermal conductance
time rate of heat flow from a unit area of a surface to its surroundings, induced by a
unit temperature difference between the surface and the environment. 9ote: %he
environment is a fluid liquids or gases!.
thermal conduction heat conduction!
process of heat transfer through a solid in the absence of convection and radiation!.
thermal conductivity $2factor!
time rate of steady2state heat flow through unit thic$ness of unit area of a homogeneous
material, induced by a unit temperature gradient in a direction perpendicular to that unit.
8nits of $ are in ItuOin.hO ft2O)6, ItuOft.hOft2O)6, or K.mOH!. Compare thermal resistivity.
&ee also thermal conductance.
thermal conductor
material that transmits heat by conduction.
thermal convection
1. transfer of heat by a fluid moving by natural variations in density in the absence of
conduction and radiation!.
2. transfer of heat by the movement of fluid.
forced thermal convection
heat transmission by mechanically induced movement of fluid.
free thermal convection natural convection!
heat transmission by movement of a fluid caused by density differences.
thermal delay
1. time period between the energi0ation of a heat2producing device and the measurable
effect of the heat produced.
2. lag in response of an external temperature change to reach equilibrium conditions.
thermal diffusion
phenomenon in which a temperature gradient in a mixture of fluids gives rise to a flow of
one constituent relative to the whole mixture.
thermal diffusivity
physical quantity that determines the rate of heat propagation in transient2state
processes. %hermal conductivity divided by the product of density and specific heat.
8nit: ft2.s or m2.s.
thermal efficiency
energy output as a percentage of the energy input of a machine or process. &ee also
thermal storage efficiency.
thermal emissivity
radiation property of a material, evaluated with its surface optically smooth and clean,
and of sufficient thic$ness to be opaque.
thermal emittance
ratio of the radiant flux emitted by a body to that emitted by a blac$body at the same
temperature and under the same conditions.
directional thermal emittance
ratio of the radiance from a surface in a particular direction to the radiance in that
direction from a blac$body at the same temperature under the same conditions.
hemispherical thermal emittance
average directional thermal emittance over a hemispherical envelope over the
surface.
spectral thermal emittance
thermal emittance based on the radiant energy emitted per unit wavelength interval
monochromatic radiant energy!.
total thermal emittance
emittance that is an integrated average for all wavelengths of radiant energy emitted.
thermal energy meter
metering system capable of measuring the energy added to or extracted from a fluid
stream. 4lso called Itu meter, heat meter, thermal meter.
thermal energy source
origin of heating or cooling effects.
auxiliary thermal source
source of thermal energy, other than solar, used, for example, to provide service water
heating; usually in the form of electrical resistance heat or thermal energy derived
from combustion of fossil fuels.
thermal environment
for human exposure, the surrounding atmosphere characteri0ed by parameters such as
air temperature, wet2bulb temperature, dew2point temperature, water2vapor pressure,
total atmospheric pressure, relative humidity, and specific humidity.
acceptable thermal environment
environment in which +,G of normally clothed men and women living in the 8nited
&tates or Canada, while engaged in indoor sedentary or near2sedentary activities,
would express thermal comfort. Compare indoor air quality acceptable!.
thermal frequency response
response of a thermal system to a periodic thermal excitation expressed as a function of
frequency. 9ote: %hermal frequency response usually is displayed by polar plot of
amplitude attenuation and time lag versus frequency.
thermal inertia
ability of a material, depending on its density and specific heat, to store heat and to
resist temperature change.
thermal insulation
material or assembly of materials used to provide resistance to heat flow.
blan$et thermal insulation
relatively flat and flexible insulation in coherent form, furnished in units of substantial
area.
bloc$ thermal insulation
rigid insulation preformed into rectangular units.
board slab! thermal insulation
semirigid insulation preformed into rectangular units having a degree of suppleness
particularly related to their geometrical dimensions.
cellular elastomeric cellular rubber! thermal insulation
insulation composed principally of natural or synthetic elastomers, or both, processed
to form a flexible, semirigid or rigid foam, having a predominately closed2cell structure.
cellular polystyrene thermal insulation board
insulation composed of cellular polystyrene in the form of boards, produced by heat
and pressure from 1! expansion of foamable polystyrene beads within a mold
beadboard!, or 2! by in2situ foaming of molten polystyrene in an extrusion mode
extruded board!.
cellular polyurethane thermal insulation
insulation composed principally of the cataly0ed reaction product of polyisicyanate
and polyhydroxy compounds, processed usually with fluorocarbon gas to form a rigid
foam having a predominately closed2cell structure.
cor$board thermal insulation
cor$ granules, cleaned, compressed, and bonded by heat and used for thermal
insulation.
embedded thermal insulation
insulation used for floors in which the insulation is located in the foundation framewor$
which later receives the concrete flooring.
evacuated thermal insulation vacuum insulation!
insulation consisting of double walls, with the space between them, with or without
pac$ing, evacuated.
fill thermal insulation loose2fill!
insulation in granular, nodular, fibrous, powdery, or similar form designed for
installation by pouring, blowing, or hand placement. =xamples are mineral or glass
fiber, cellulosic fiber, diatomaceous silica, perlite, silica aerogel, and vermiculite.
foamed2in2place thermal insulation foam2in2situ insulation!
insulation formed by introducing into prepared cavities a chemical component and a
foaming agent that react to fill the space with a foamed plastic.
high2vacuum thermal insulation
thermal resistance system that depends on a very high vacuum for its performance.
mineral fiber thermal insulation
insulation composed principally of fibers manufactured from roc$, slag, or glass, with
or without binders.
multicellular metal foil thermal insulation
thermal insulation consisting of waffled or corrugated sheets of metal foil to form a
cellular structure.
multilayer thermal insulation
many thin layers of materials combined to obtain a very high thermal resistance
superinsulation!.
open2cell foamed plastic thermal insulation
cellular plastic in which interconnected cells predominate.
perlite thermal insulation
insulation composed of natural perlite ore, a glassy volcanic roc$ expanded by heat to
form a cellular structure.
reflective thermal insulation
insulation which reduces radiant heat transfer across spaces by use of one or more
surfaces of high reflectance and low emittance, for example, aluminum foil.
self2supporting thermal insulation
thermally insulated structure where the insulation possesses sufficient mechanical
strength to serve as a constructional material itself.
slab insulation
thermal insulation applied under slab2on2ground construction.
sprayed thermal insulation sprayed2on insulation!
insulation formed by spraying fine fibrous material onto a surface previously covered
with an adhesive; also by simultaneously spraying a chemical component and a
foaming agent.
structural thermal insulation
insulation used as a part of the load2carrying frame of a structure, such as the walls of
a cold room or the body of a refrigerated vehicle.
thermal insulation finish
material applied to insulation to provide a smooth, even finish, to strengthen and protect
the surface, and to improve its appearance.
thermal insulation system
thermal insulation in place, complete with accessories, vapor retarders, and facings as
required for expected performance.
thermal lag
delay in action of the sensing element of a control device due to the time required for
the sending element to reach equilibrium with the property being controlled.
thermal lift
difference between evaporating and condensing temperatures and pressures. &ee also
head.
thermal radiance
rate of radiant emission through unit solid angle over unit pro"ected area of a source in a
stated angular direction from the surface usually the normal!.
thermal radiant flux density
rate of radiant energy emitted from unit area of a surface in all radial directions of the
overspreading hemisphere. &ee also radiant flux density.
thermal radiation
transmission of energy by means of electromagnetic waves emitted due to temperature.
1adiant energy of any wavelength when absorbed may become thermal energy that
increases the temperature of the absorbing body. &ee also heat transfer radiation
coefficient.
equivalent direct radiation =71!
thermal radiation expressed in terms of square foot of steam radiator surface emitting
2', Itu per hour. It is the same as an area in square metres, each of which radiates
/(/ watts per square metre. 9ote: 7o not use this I2> term in &I.
thermal reflectance
fraction of the incident radiation on a surface that is reflected from that surface. 9ote:
6or an opaque surface, the sum of reflectance, transmittance, and absorptance is unity
at any wavelength of radiation.
thermal reflection
portion of the radiosity from a surface which is contributed by reflection.
thermal regenerator thermal recuperator!
heat transport apparatus designed for utili0ing waste heat. <eat transport is achieved
either by accumulation of heat in a suitable material through which alternately pass a
warm fluid and the fluid to be heated, or in a heat exchanger where both fluids circulate
counterflow. &ee heat exchanger.
thermal relay
1. relay activated by change in temperature.
2. relay in which the displacement of the moving contact member is produced by
heating of a part of the relay under the action of electric currents.
thermal resistance 12value!
under steady conditions, the mean temperature difference between two defined
surfaces of material or construction that induces unit heat flow through unit area. 9ote:
%hermal resistance and thermal conductance are reciprocals. %hermal resistances are
12values; to obtain the 82factor, overall thermal transmittance, the 12value for either
materials or constructions must first be evaluated because, by definition, the 82factor is
the reciprocal of the 12value.
thermal resistivity
under steady conditions, the temperature difference between parallel surfaces of a slab
large enough so there is no lateral heat flow! of unit thic$ness that induces unit heat
flow through unit area. 9ote: %hermal resistivity and thermal conductivity are
reciprocals. %hermal resistivity is the 12value of a material of unit thic$ness.
thermal sensation
conscious feeling, commonly graded into categories of cold, cool, slightly cool, neutral,
slightly warm, warm, and hot.
thermal shroud
in a space simulator, surfaces usually blac$ened! cooled to very low temperatures,
which surround the test ob"ect.
thermal storage
1. temporary storage of high2 or low2temperature energy for later use.
2. accumulation of energy in a body or system in the form of sensible heat temperature
rise! or latent heat change of phase!.
#. technology or systems of accumulating cooling or heating capacity for subsequent
use. &ee also thermal storage system.
cool storage
technology or systems used to store cooling capacity.
heat storage
technology or systems used to store heating capacity.
latent storage
use of a phase change of a medium for storing heating or cooling capacity.
naturally stratified storage
thermal storage in which temperature stratification is achieved and maintained by
density differences alone, and not by mechanical separators.
sensible storage
use of a change in temperature of a medium for storing heating or cooling capacity.
stratified storage
thermal storage vessel in which a thermocline exists.
thermal storage capacity
quantity of heat that can be retained by a thermal storage system and be available for
future use.
instantaneous thermal storage capacity
actual rate at which heating or cooling capacity is supplied to, or withdrawn from,
storage.
integrated thermal storage capacity
total amount of energy supplied to storage, or withdrawn from storage, during
charging or discharging.
thermal storage device
container plus all the contents of the container used for storing thermal energy. %he
transfer fluid and accessories, such as heat exchangers, agitators, circulating pumps,
flow2switching devices, valves, and baffles which are integral with the thermal storage
container are considered a part of the storage device.
ice2on2coil thermal storage
container tan$! in which ice is formed on tubes or on pipes.
thermal storage efficiency cycle figure2of2merit!
ratio of the integrated discharge capacity to the hypothetical maximum available
capacity for a single cycle of operation. 9ote: <ypothetical maximum available capacity
is computed as follows;for sensible storage, multiply the average specific heat of the
storage medium by the mass of the medium in storage and the difference between the
average storage inlet temperatures during charging and discharging, for a single cycle.
6or latent storage, multiply the change in specific enthalpy associated with the liquidsolid
phase change by the mass of medium in storage that changes phase, for a single
cycle.
cycle thermal efficiency
ratio of the integrated energy output to the integrated energy input of a process or
machine, for a single cycle of operation.
long2term thermal efficiency
ratio of the total integrated discharge capacity to the total integrated charge capacity
for a representative set of cycles of operation.
storage efficiency
discharge capacity divided by charge capacity. &ee also cycle thermal efficiency.
thermal storage load leveling
charging a thermal storage system at a constant rate during a complete cycle.
thermal storage medium
substance in which cooling or heating capacity is stored.
thermal storage system
system wherein the load demand is met by stored thermal energy.
chiller2aided storage
thermal storage system that has a chiller to supplement cooling capacity of the
storage. 4lso called live load chilling.
compressor2aided storage
operation of the compressor of an ice storage system during the discharging period.
demand2limited storage
thermal storage system controlled to limit the electric power demand.
direct ice contact external melt!
ice storage system using a method of heat exchange in which ice is formed by direct
refrigeration and melted by immersion in circulating water or secondary coolant. 4lso
called static direct contact storage.
full storage
thermal storage system having capacity to meet all on2pea$ cooling or heating
requirements by being charged off2pea$, and without energy added on2pea$.
indirect ice contact internal melt!
ice storage system using a method of heat exchange in which ice in containers is
formed and melted by a circulating secondary coolant enclosed in a pipe or tube.
partial storage system
1. system wherein the load demand is met by a combination of stored thermal energy
and an energy conversion device.
2. system that has to be operated during on2pea$ as well as in off2pea$ periods. &ee
demand2limited storage; compressor2aided storage; load2leveling storage.
roc$bed regenerative system
system of air conditioning that uses pac$ed gravel beds for both evaporative cooling
and heat energy storage.
thermal time lag
1. time interval by which the pea$ thermal response falls behind lags! the pea$ thermal
excitation in a thermal system.
2. phase difference in hours between the exterior and interior surface temperatures
when the exterior surface is sub"ected to a sine2wave temperature change having a
2'2hour period.
thermal transfer fluid
fluid circulated through closed circuits to transfer heat from one location to another.
thermal transmittance 82factor!
heat transmission in unit time through unit area of a material or construction and the
boundary air films, induced by unit temperature difference between the environments
on each side. 9ote: %his heat transmission rate is also called the overall coefficient of
heat transfer.
K2factor
82factor converted into electrical terms for calculations in electric heating. %he amount
of heat flow, in watts per square foot per degree 6ahrenheit temperature difference
K.ft2O)6! between air on the inside and air on the outside of the building section wall,
floor, roof, or ceiling!. 6or conversion, K 5 ,.2*#8.
thermistor
thermoelectrical element in which the electrical resistance falls appreciably with a rise in
temperature; often used as a thermometer. &ee also anemometer thermal!.
thermocline
layer of fluid in which the temperature and density gradient is greater than, and which
separates, the cooler fluid below it and the warmer fluid above it.
thermocouple
"unction of two wires of dissimilar materials, not necessarily metal, with the property of
generating an emf related to the temperature of their "unction. Compare thermopile.
thermocouple system
combination of one or more thermocouples in a circuit with switching and measuring
devices to enable temperatures to be indicated or recorded continuously or
intermittently.
thermodynamic equilibrium
equilibrium in a system when the physical variables have uniform values that do not
change in time. 6urthermore, if the system is not an isolated one, these variables
should have the same values for both the system and its surroundings.
thermodynamics
science of the relation of heat to other forms of energy. &ee also thermodynamics laws.
thermodynamic shoc$
implosive impact in liquid, caused by sudden condensation of vapor into its subcooled
liquid. %his phenomenon can occur when the liquid is about -, to +()6 ## to '/)C!
cooler than the saturation temperature of the contact vapor. It creates a loud sound and
can cause severe local pressure stresses in the container.
thermoelectric cooling
see >eltier effect; refrigeration thermoelectric!.
thermogram
photograph or two2dimensional record of an image which maps the apparent
temperature of a scene as sensed by an infrared imaging system.
thermography
process of generating a thermogram by using an infrared imaging system, usually with
some means of temperature calibration.
thermometer
instrument for measuring temperature.
acoustical thermometer
one that evaluates temperatures from the measurement of the speed of sound in a
gas; used for very low temperatures.
alcohol thermometer
bulb with a vertical capillary tube containing alcohol colored! which expands or
contracts with changes in temperature, having graduated mar$ings so that the end of
the alcohol column indicates the ambient temperature.
bimetallic thermometer
one that indicates temperature from flexing of two strips of materials of different
coefficients of expansion bonded together.
dial thermometer
one that indicates temperature by a pointer moving over a circular scale.
dry2bulb thermometer
in general, any thermometer that indicates the temperature of air or other fluids!;
distinguished from wet2bulb thermometer.
electric contact thermometer
thermometer designed to indicate temperature by closing in succession a series of
electrical contacts.
electric resistance thermometer
temperature2measuring and display instrument in which an electric resistance varies
as a function of the temperature.
indicating thermometer
thermometer designed for the visual display of temperature.
Hata thermometer
alcohol thermometer used to measure low velocities in air circulation, by heating the
large bulb of the thermometer above 1,,)6 #+)C! and noting the time it ta$es to cool
from 1,, to *()6 #+ to #()C! or some other interval above ambient temperature, the
time interval being a measure of the air current at that location.
magnetic thermometer
one that indicates temperature from the measurement of magnetic properties e.g.,
susceptibility! of any suitable substance; used for very low temperatures.
mercury thermometer
bulb and attached glass capillary tube containing mercury which expands or contracts
with changes in temperature; so mar$ed that the end of the mercury column indicates
the ambient temperature.
nuclear resonance thermometer
one that uses the nuclear paramagnetism of metals to deduce the temperature from
the spin2lattice relaxation time; used for very low temperatures.
recording thermometer temperature recorder; thermograph!
one that indicates temperature by traces on a moving chart; recording may be done
on a cylinder, a circular chart, or a strip chart.
solid2expansion thermometer
one based on the expansion of a solid substance usually bimetallic!.
sonic thermometer
acoustical thermometer.
vapor pressure thermometer
one based on pressure built up by the vapor evolved by liquid in a sealed container.
wet2bulb thermometer
one that measures wet2bulb temperature.
thermometry
part of applied physics relating to the measurement of temperature.
thermophysics
study of physical phenomena related to heat.
thermopile
1. several thermocouples in a bundle with all "unctions at each end exposed to the
same temperature so that the emf output is the sum of the several emfs.
2. number of thermocouples wired consistently in series or in parallel to measure small
or average temperature differences.
thermosiphon
circulation by the forces induced by the differences in densities of cooler and warmer
fluids.
thermostat
1. automatic control device responsive to temperature used to maintain constant static!
temperature.
2. temperature2actuated switch.
#. instrument which responds to changes in temperature, and which directly or indirectly
controls temperature.
'. temperature2sensitive device that automatically opens and closes an electric circuit
to regulate the temperature of the space with which it is associated. &ee also heat
anticipation.
aquastat
thermostat designed for use in water.
direct2acting thermostat
1. thermostat in which the output increases proportionally to an increase in the value
of the sensed variable.
2. pneumatic instrument which permits passage of control air when temperature of the
controlled medium is higher than the temperature for which the instrument is set
and cuts off the air when temperature goes below the temperature for which the
instrument is set.
dual thermostat
1. pneumatic thermostat designed to maintain one temperature during the day and a
lower temperature during the night or during unoccupied periods or changes action
from direct acting 74! to remote acting 14! for seasonal changeover when
switched from remote signal.
2. two temperature controls in one enclosure.
free0e2stat
limited2fill thermal element, usually 2, feet in length, located in the mixed2air portion of
an <E4C unit which opens an electrical circuit if any one2foot portion of the element
reaches its set point usually #()6 or 2)C!. It usually shuts down the <E4C unit and.or
alarms.
insertion thermostat
1. thermostat which has an element that is inserted directly into the airstream of a duct
or pipe.
2. thermostat with the sensing member in the sensed variable but with the controlling
element outside.
limited liquid2charged thermostat gas2charged thermostat!
vapor pressure thermostat charged with a restricted amount of liquid, so that above a
given temperature the charge becomes a superheated vapor.
line2voltage electric heat thermostat
device which acts to control automatically the temperature of a room or space in which
it is installed by switching directly the resistive noninductive electrical load.
liquid2charged thermostat
vapor thermostat charged with such an amount of liquid that a certain quantity of liquid
remains in the bulb whatever the operating conditions may be.
remote bulb thermostat
thermostat in which the sensing bulb can be located at a distance from the instrument
proper although remaining flexibly connected to it.
reverse2acting thermostat
1. thermostat in which the output decreases proportionally to an increase in the value of
the sensed variable.
2. pneumatic instrument that permits passage of control air when temperature is lower
than the temperature for which instrument is set and cuts off the air when the
temperature goes higher than the temperature for which the instrument is set.
room thermostat
thermostat located in a room so as to respond to room temperature and thereby
control heating or cooling devices.
surface thermostat
1. automatic control device having a sensing element responsive to the temperature
of the surface being controlled.
2. temperature controlling device located on a surface to respond to surface
temperatures and initiate control actions.
tan$ thermostat
device which senses changes in the temperature of stored water, and controls, by
means of separate components, the flow of energy to maintain a selected
temperature.
two2stage thermostat
1. thermostat that handles two separate circuits in sequence.
2. single temperature controller designed to control temperature at two distinct set
points.
water heater thermostat
device that acts to control the energy flow to a water heater in relation to the water
temperature sensed by its thermal element.
thermostat absorber charge
combination charge consisting of a solid adsorbent and an inert gas adsorbate, used in
the power system of a thermostatic expansion valve.
thermostat anticipator
device that adds heat within a thermostat in anticipation of overshoot.
thermostat bulb thermostat phial; feeler!
temperature2sensitive element of a thermostat.
thermostat bulb well
separate soc$et or well used with immersion thermostats so that the thermostat can be
removed without disturbing the controlled system.
thermostat compensator
in a gas2charged thermostat, a device that compensates for fluctuations caused by
temperatures, in certain parts of the power system; different from the temperature of the
bulb.
thermostat cross charge
charge used in the power system of a thermostatic expansion valve that differs from the
refrigerant charge used in the refrigerating plant. Compare thermostat straight charge.
thermostat liquid charge wet charge; cross2ambient charge!
charge in the power system of a thermostat or a thermostatic expansion valve usually a
straight charge!.
thermostat night setbac$
manual or automatic reset of temperature control point of a thermostat, usually coupled
with a start2up time for restoration of desired daytime temperature level.
thermostat offset
difference between the cut2in point and the scale setting.
thermostat power system power element!
either a bimetallic element or a bulb connecting with a bellows directly or through a
capillary tube.
thermostat straight charge
charge employed in the power system of a thermostat expansion valve which consists
of the same refrigerant as used in the refrigeration plant. Compare thermostat cross
charge.
three2wire service
1. electrical service supplied to the user by the utility company.
2. electrical service of a three2phase power form.
throttling
1. of a fluid, an irreversible adiabatic process which consists of lowering pressure by an
expansion without wor$.
2. reduction in fluid or current flow by adding resistance.
throttling expansion
expansion via flow restriction! across any orifice during which no mechanical wor$ is
transferred by the fluid to the surroundings.
throttling range
1. change in controlled variable required to move the throttle from one of its extreme
limits of travel to the other.
2. amount of change in input required to produce a throttle control output that travels
through its required range.
thrust collar
collar, the lateral surface of which is designed to bear the axial load of a shaft. Compare
bearing thrust!.
time constant
in control theory and practice, for the output of a first2order lag or lead! system forced
by a step or impulse, time constant is the time required to complete -#.2G of the total
rise or decay. 4 system whose dynamic response can be expressed by a first order
differential equation is a first order system, e.g., a mercury thermometer in air.!
time delay
1. time interval between the manifestation of a signal at one point and the manifestation
or detection of the same signal at another point. 9ote: Menerally, the term Btime
delayD is used to describe a process whereby an output signal has the same form as
an input signal causing it, but is delayed in time; that is, the amplification of all
frequency components of the output are related by a single constant to those of
corresponding input frequency components but each output component lags behind
the corresponding input component by a phase angle proportional to the frequency
of the component.
2. time interval between when a command is given and when it is executed.
time, rise electrical!
1. measure of the time required for a circuit to change its output from a low2voltage level
to a high2voltage level, normally from 1, to *, percentage points.
2. time required for the output of a system other than first2order! to ma$e the change
from a small specified percentage often ( to 1,G! of the steady2state increment to a
large specified percentage often *, to *(G! either before overshoot or in the
absence of overshoot.
tin pest tin rot!
polymorphic modification of tin that causes it to crumble into a powder $nown as gray
tin. It is generally accepted that the maximum rate of transformation occurs at about
R',)6 R',)C!, but transformation can occur as high as about (()6 1#)C!.
ton of refrigeration!
time rate of cooling equal to 12,,,, Itu.h approximately #(1/ K!.
cooling tower ton
total heat2re"ection capacity of a cooling tower; traditionally, 1(,,,, Itu.h. 9ote: %his
value is based on 2(G compressor heat added to a ton of refrigeration.
dry ton
sensible heat load expressed in tons of refrigeration.
total ton
total heat load expressed in tons of refrigeration; the sum of the dry tons and the latent
tons wet tons!.
wet ton moisture ton!
latent heat load expressed in tons of refrigeration.
ton day of refrigeration
heat removed by a ton of refrigeration operating for a day, 2++,,,, Itu approximately
+'.# $K!. It is a quantity approximately equal to the latent heat of fusion or melting of
1 ton 2,,, lb! of ice, from and at #2)6.
ton hour
quantity of thermal energy in tons 12,,,, Itu! absorbed or re"ected in one hour.
torsional excitation fan!
type of excitation in which the external force is applied to the fan through the hub in the
form of torque pulsations. &ee also excitation.
total suspended particulates
mass of particulates suspended in a unit volume of air as collected by a high2volume air
sampler.
transducer
1. device which converts energy from one form to another, e.g., a loudspea$er
transforms electrical energy to acoustical energy.
2. element which receives information in the form of one physical quantity and transmits
that information in the form of another physical quantity.
#. device by means of which energy can flow from one or more transmission systems or
media to one or more other transmission systems or media. 9ote: %he energy
transmitted by these systems or media may be of any form e.g., it may be electric,
mechanical, or acoustical!, and it may be of the same form or different forms in the
various input and output systems or media.
pneumatic2electric transducer pneumatic2electronic transducer!
device that converts a pneumatic value to an equivalent electric volt, milliamp! value.
transfer fluid thermal storage!
fluid that carries energy from one location to another. &ee also solar collector transfer
fluid.
transformer
electromagnetic device for changing alternating current electrical energy to a different
voltage.
transient
pulse or other temporary phenomenon occurring in a system prior to reaching a
steady2state condition.
transistor
semiconductor device used for signal amplification, normally having three connections:
an emitter =, a base I, and a collector C. It can also be used as a switch and exhibits
considerable power gain under most circumstances.
transition point
at a stated pressure, the temperature or at a stated temperature, the pressure! at
which two solid phases exist in equilibrium; that is, an allotropic transformation
temperature or pressure!.
transmission
transport of substances, energy, or indicated values from one place to another with or
without impedances.
analog transmission
1. method by which analog values are transferred from the sensing location to a
controlling location.
2. sending of a continuously variable signal from one point to another.
duplex transmission
1. communications! pertaining to a simultaneous two2way independent transmission
in both directions.
2. double transmission! transmission of each data word twice and comparison bit by
bit for accuracy.
four2wire transmission
1. in three2phase power transmission, the use of four wires KT= connected.
2. transmission of data in two directions simultaneously over two pairs of wires. 4lso
$nown as full duplex transmission.
liquid transmission
in applications where the sensing point is always at a higher temperature than the rest
of the system, vapor pressure is transmitted by a column of liquid.
simplex transmission
transmission in one direction at a time. %he direction is manually switched.
synchronous transmission half2duplex!
1. refers to transmission in which synchroni0ation is achieved in the absence of any
other character than a control character.
2. transmission in which the sending and receiving instruments are operating
continuously at substantially the same frequency and are maintained, by means of
correction, in a desired phase relationship.
two2wire transmission
1. electrical power transmission system that requires only two conductors; thus, it is a
single phase system.
2. sending and receiving of electrical signals over the same pair of wires in both
directions.
transmission line
coaxial cable, leased line, or other system of conductors used to transfer data or other
signal energy from one location to another.
transmission loss
reduction in magnitude of some characteristic of a signal between two stated points in a
system.
transmission networ$
entire system used for transmitting data from a central processor to remote panels, and
vice versa. Includes the entire trun$ cable system for single or multiple data channel
access as well as all the transceivers or repeaters!. 6or leased lines, the interface, data
modems, and carrier conductors are also included.
transmit computer!
1. to move data from one location to another.
2. to transfer information to a new location replacing whatever was previously stored.
transmittance radiation!
portion of thermal radiation incident on a surface that is transmitted through the surface.
Compare thermal transmittance. 9ote: %hermal transmittance usually is used for heat
flow through walls, but transmittance or transmissivity! is more often referred to as a
radiation property.
trap
device for preventing passage of something, often while allowing other matter to
proceed. &ee steam trap.
dead2end trap
piping arrangement for collecting oil or liquid refrigerant from suction gas prior to entry
to a compressor.
liquid trap
device for collecting liquid refrigerant at a given point in a refrigerating circuit.
scale trap
in a refrigeration system, an arrangement for gravitational separation of the larger
impurities from a refrigerant.
suction trap suction line accumulator; liquid separator!
accumulator installed in the suction line between evaporator and compressor to trap
liquid carryover from the evaporator and to prevent it from reaching the compressor.
triple point
particular temperature and pressure at which three different phases of one substances
can coexist in equilibrium.
troffer luminaire!
electric lighting fixture equipped for <E4C systems either with a diffuser to warm a room
with the heat dissipated by lighting, or an exhaust vent to reduce the heat load.
trombe wall
solar energy2absorbent interior mass structural wall heated by south2facing gla0ing.
tube
1. long, usually cylindrical body with a hollow center used especially to convey fluids
tubing is an obsolete term!.
2. tubular conduit for transport of fluids or finely divided solids; also, a hollow structural
member; a hollow product of round or other cross section. 9ote: 4 tube is designated
by its exact outside diameter and its exact wall thic$ness, which may be described in
gage numbers or other units. 4n exception exists for copper tubes as used in the
plumbing industry. %hese are designated by the nominal si0e, which for 22inch
diameter or less approximates the inside diameter; while the exact outside diameter
is ,.12( in. #.2 mm! larger than the nominal si0e. 4 tube may be helical welded, lap
welded, spiral welded, butt welded, or seamless.
Iourdon tube
curved oval tube that tends to straighten when the pressure is increased, and
recurves with pressure decrease.
bra0ed tube
tube made from sheet or strip with a longitudinal bra0ed "oint.
capillary tube
1. small bore tube used for metering by controlling length and bore si0e. In
refrigeration, a tube of small internal diameter used as a refrigerant pressure and
flow control between high and low sides.
2. tube used to transmit pressure from the sensitive bulb of some temperature
controls to the operating element. &ee also refrigerating capillary tube.
condenser tube heat exchanger!
tube manufactured to special requirements, as to tolerances, finish, and temper.
copper water tube
seamless copper tube of certain standard si0es, in straight lengths and coils, used
with flared or soldered "oints for transporting gases and liquids.
finned tube
heat transfer tube or pipe with extended surface of fins, dis$s, or ribs.
seamless drawn tube
tube produced by drawing and forming operations from a pierced bar or hollow billet.
soft copper tube
deoxidi0ed and dehydrated, seamless, soft2copper tube, thoroughly annealed to
assure good bending and flaring characteristics.
welded tube
tube made from plate, sheet, or strip with welded longitudinal or helical seam.
turbine
fluid2energi0ed acceleration machine for generating rotary mechanical power from the
energy in a fluid stream.
gas turbine
1. prime mover in which gas, under pressure or formed by combustion, is directed
against a series of turbine blades; the energy in the expanding gas is converted
into mechanical energy supplying power at the shaft. 4lso called a combustion
turbine, simple2cycle turbine. continued on next page!
2. electric2generating station in which the prime mover is a gas turbine.
combined2cycle gas turbine
device that uses waste heat boilers to capture exhaust energy for steam generation.
regenerative cycle gas turbine
simple2cycle gas turbine to which has been added a heat exchanger to warm
incoming combustion air with heat from exhaust gases to increase thermal efficiency.
turbocompressor stall
phenomenon of instability that may occur in centrifugal or axial flow compressors,
characteri0ed by aerodynamic bloc$age, or the brea$away of the flow from certain
sections of the passage between the blades.
turboexpander expansion turbine!
in cold air or gas refrigeration cycles, a turbine in which the compressed gas expands
and produces mechanical energy.
turbulator
flow enhancing device to increase coil heat transfer efficiency.
turning vane air splitter!
curved strip of short radius placed in a sharp bend or elbow in a duct to direct air around
the bend.
ultraviolet 8E! radiation
range of electromagnetic radiation wavelengths from about ',, nm, "ust beyond the
violet in the visible spectrum, to about ' nm, on the border of the x2ray region. 8E
photons have enough energy to initiate some chemical reactions, to degrade most
plastics, and to $ill microorganisms.
unit point selector
device which selects the monitoring points to be used for observation or data sensing
and collection.
use factor
percent capacity reali0ed, time that a system is operated. Compare diversity factor.
utili0ation factor
same as use factor.
vacuum
state in which the gas pressure is lower than atmospheric pressure.
absolute vacuum
space totally void of matter theoretical!.
deep vacuum high vacuum!
vacuum having a pressure between 1 ⋅ 1,R# and 1 ⋅ 1,R- mm <g ,.1### and
,.,,,1### >a!.
ultrahigh vacuum
a"so#!te press!re "e#ow 75 ⋅ 1/− 9 mm H' *1/− 5 9a+%
vacuum test
test to chec$ the gastightness of an uncharged refrigeration system by drawing a
vacuum on it.
validity
correctness; especially the degree of closeness by which iterated results approach the
correct result.
valve
device to regulate or stop the flow of fluid in a pipe or a duct by throttling.
ad"ustable capillary valve
having male threads on a stem that fit female threads in the solid body, leaving a
capillary channel between the threads regulated by the number of threads engaged.
air valve
device to control volume and flow in air distribution. &ee also damper.
angle valve
valve in which the inlet and outlet are at an angle, usually '( or *, degrees.
antisiphon valve
valve or mechanical device that eliminates siphon flow.
automatic expansion valve
controlling device for regulating automatically the flow of volatile refrigerant into a
cooling unit, actuated by changes in evaporator pressure. %he basic response is to
regulate evaporator pressure.
automatic valve
valve that automatically regulates the flow of a fluid as a function of temperature,
pressure, etc.
bac$ pressure valve evaporator pressure regulator; =>1 valve!
automatic valve located between the evaporator outlet and compressor inlet that is
responsive to its own inlet pressure, to prevent the evaporator pressure from falling
below a selected value.
bac$up valve
head pressure control valve.
ball valve
1. chec$ valve consisting of a ball resting on a spherical seat.
2. valve consisting of a rotatable ball with a hole through its center. &ee plug valve.
beam valve feather valve; leaf valve!
reed valve in which the flexible metal strip is attached at both its ends.
bellows valve
pac$less valve in which a bellows forms the seal between the ad"ustment spindle and
the valve body.
bleed valve
valve which has a fixed orifice incapable of being closed by an action of the valve,
permitting a flow through or in parallel with the main valve port.
blowdown valve
valve used to remove excess undissolved solids from a steam boiler, by maintaining
mud drums clear.
blowoff valve
safety valve that maintains a predetermined pressure in a vessel by discharging
excess gas to the atmosphere. Compare relief valve. &ee safety valve.
butterfly valve
valve in which the regulating mechanism is a circular or elliptical dis$ that is rotatable
about an axis.
cantilever valve flapper valve!
reed valve in which the flexible metal strip is attached at only one of its ends.
charging valve
valve used to charge or add refrigerant to a system or add oil to a compressor
cran$case.
chec$ valve nonreturn valve!
valve allowing fluid flow in one direction only.
coc$ valve
generally a plug valve, usually for regulating the flow of a fluid, and requiring a wrench
for operating.
companion valve bloc$ valve!
pairs of mating stop valves that allow sections of a system to be "oined before opening
these valves, or separated after closing them.
condensing pressure valve
automatic valve responsive to inlet pressure to prevent compressor discharge
pressure from falling below a specific value. 9ormally used as a form of head
pressure control bac$up valve!, but also used on refrigerating systems for
maintaining hot2gas defrost systems.
constant2level valve
device for maintaining within a reservoir a constant level of fluid; e.g., oil fuel, for
delivery to an oil burner.
constant2pressure expansion valve
valve that maintains a constant output pressure regardless of the input pressure.
diaphragm valve membrane valve!
pac$less valve in which the seal between the ad"ustment spindle and the valve body is
a diaphragm.
direct2acting diaphragm valve
valve that closes with the admission of fluid pressure to a diaphragm and opens when
pressure is reduced.
discharge valve delivery valve, outlet valve!
in a compressor, the valve that allows compressed fluid to flow from the cylinder and
prevents return flow.
discharge line valve discharge stop valve!
shutoff valve fitted to a compressor, or in the discharge line ad"acent to it, which
permits isolating the compressor from the discharge line.
dis$ valve diaphragm valve!
compressor valve consisting of a metal dis$.
diverting valve
three2way valve piped to supply a single source of fluid to either of two outlets.
double2seated valve
valve having two seats and two dis$s arranged so that the upstream pressure is acting
on one side of one dis$ and the opposite side on the other dis$. %his acts to cancel
system forces and allows the use of a smaller actuator.
drain valve
valve fitted to the lowest point of an apparatus or refrigeration system for the purpose
of tapping or draining the system.
dual2pressure regulator valve
upstream pressure regulator equipped with two pressure controls, used in refrigerant
suction lines to provide free0e2up protection or for safety pressure relief.
electronic expansion valve
controlling device for regulating flow of refrigerant in a cooling unit. It is actuated
electrically, based on evaporator and superheat conditions, and typically controlled by
a microprocessor. %he basic response is to the superheat or to the liquid2vapor
interface.
emergency relief valve
manually operated safety valve for discharge of refrigerant in case of fire or other
emergency.
firing valve
lubricated, plug2type variable position valve, usually operated with an attached handle
or, in the large si0es, by a loose2fitting $ey or extended handle wrench.
float2type expansion valve float valve!
expansion valve operated by a change in liquid level.
float valve
valve actuated by a float in a fluid container.
flow control valve
one that shuts automatically when the circulator pump stops, thereby preventing
gravity circulation.
hand valve
valve that is operated manually by a handwheel attached to the spindle.
head pressure control valve
automatic valve located between the air2cooled condenser and the receiver that will
bac$ up liquid in the condenser to reduce the effective area of the condenser, thus
$eeping the discharge pressure to a predetermined minimum value during low
ambient temperatures. 8sed in con"unction with a pressure differential valve between
the discharge line and the receiver.
high2pressure float valve high2side float valve!
float2type expansion valve operated by changes in liquid level on the high2pressure
side.
hot2gas defrost valve
solenoid valve located in a bypass line running from the outlet of the compressor to
the evaporator.
$ing valve master valve!
1. stop valve between receiver and liquid main.
2. stop valve on boiler head.
lift chec$ valve
chec$ valve with the mechanism lifting vertically from its seat to allow the passage of
fluid.
liquid2in"ection valve
valve which controls the introduction of liquid refrigerant, e.g., into the intercooler in a
multistage compression system.
low2pressure float valve low2side float valve!
float2type expansion valve operated by changes in liquid level on the low2pressure
side.
lubricated plug valve
valve of the pierced plug2and2barrel type, provided with means for maintaining a
lubricant between the bearing surfaces.
manual expansion valve hand valve!
manually operated needle2type valve for controlling the flow of liquid refrigerant to an
evaporator.
manual reset valve
automatic shutoff valve installed in gas supply piping and set to shut off when unsafe
conditions occur. %he device remains closed until manually reopened.
mixing valve
three2way valve to mix two fluids. Compare diverting valve.
modulating control valve
valve capable of increasing or decreasing by increments the fluid flow according to
deviation from the set control value.
motori0ed valve motor2operated valve!
valve operated by an electric motor.
mushroom valve
poppet valve whose head is mushroom2shaped.
needle valve
1. valve having a very small hole in the seat, fitted with a needle shaped plunger.
2. valve in which the obturator is a stem ending in a conical point which mates with a
corresponding valve seat.
nonreturn valve
chec$ valve.
oil charge valve
valve enabling one to charge or top a refrigerating system with oil.
oil drain valve oil purge valve!
valve for draining out the oil from all collection points in a system.
pac$less valve
valve that does not use pac$ing to seal against lea$s around the stem, e.g., bellows
valve.
pilot valve
small valve where the opening or closing directly influences a larger valve, as in a
servo system.
plug valve plug coc$!
valve in which the fluid passage is a hole in a rotatable tapered plug in the valve body.
pneumatic operated valve
valve with the positioning mechanism actuated by compressed air.
poppet valve
valve comprising a mushroom2shaped circular head and integral stem.
pressure controlled valve
valve in which the position of the valve head in relation to the valve seat is determined
by the deviation in pressure from the set value.
pressure differential valve spring2loaded chec$ valve!
automatic valve that opens in response to a pressure difference across the valve port.
Commonly used in con"unction with a head pressure control valve bac$up valve!
between discharge line and receiver inlet.
pressure2reducing valve
1. valve used to reduce a high supply pressure to a usable level.
2. valve which maintains a uniform pressure on its outlet side irrespective of pressure
variation on its inlet side.
pressure relief valve
safety valve that is held closed by a spring or other means and designed to
automatically relieve pressure in excess of its setting.
pressure2sustaining valve
valve providing maintenance of designated pressure level within a system.
pumpout valve
valve enabling connection between a refrigerating system and a vacuum pump.
purge valve
device to allow fluid to flow out of system, particularly noncondensable gases; also
called a drain valve. &ee purge.
radiator valve
manual or automatic valve that controls the flow of the fluid to a radiator.
reed valve flexing valve!
compressor valve consisting of a plate having a number of slots and flexible steel
strips fitted over the slots.
refrigerant control valve refrigerant expansion valve!
valve that meters refrigerant and maintains pressure2difference between the highpressure
side and the low2pressure side of a mechanical refrigerating system while
the unit is operating.
relief valve
safety valve actuated by inlet pressure which opens in proportion to the increase in
pressure above the opening pressure.
restrictor valve
in a cooling and heating heat pump, a valve automatically ensuring that an additional
length of capillary regulator is put into operation when the system is on heating cycle.
reverse2acting diaphragm valve
one which opens with the increase of fluid pressure to a diaphragm and closes when
pressure is reduced.
reversing valve four2way valve!
1. in a refrigerating system, a device which enables reversing the evaporator and the
condenser for hot gas defrosting.
2. in a heat pump system, a device to effect changeover between heating and cooling
cycles.
ring2plate valve ring valve!
compressor valve consisting of a circular plate having a series of ports over which one
or more ring plates seat.
safety valve
pressure relief valve actuated by inlet pressure, and characteri0ed by rapid opening or
pop action.
service valve
1. valve intended to isolate an apparatus from the rest of the system.
2. device used by service technicians to chec$ pressures and charge refrigerating
units.
servo operated valve pilot2controlled valve!
valve operated by a mechanism that directly responds to some controlled conditions.
&ee system servo!.
shunt valve bypass valve!
valve for diverting flow around a component, connection, or pipe, instead of through it.
slave valve
valve that receives its input signal from another valve.
slide valve piston valve!
valve in which the sliding element has several ports that close or correspond with
counterpart ports in the valve body.
solenoid valve
valve that is closed by gravity, pressure, or spring action and opened by the magnetic
action of an electrically energi0ed coil, or vice versa.
solenoid liquid2line valve
solenoid valve installed on the liquid2refrigerant line.
spring2loaded pressure relief valve
safety valve which opens at a predetermined pressure, but will also close when the
pressure returns to normal, through the action of a spring.
stop valve
shutoff valve of any type, as distinguished from a flow control valve.
suction valve
in a compressor, the valve which allows refrigerant to enter the cylinder from the
suction line and prevents return flow.
suction2line valve suction stop valve!
shutoff valve fitted to the compressor, or in the suction line ad"acent to it, to isolate the
compressor from the suction line.
suction2pressure regulating valve C.>.1.! holdbac$ valve!
automatic valve located between the evaporator outlet and the compressor inlet that is
responsive to its own outlet pressure and functions to throttle the vapor flow to prevent
the outlet pressure from exceeding a selected value. It is used primarily to prevent
overload on compressor motors.
swing2chec$ valve
nonreturn valve with a freely rotatable closure actuated by the resultant forces on both
sides.
thermally actuated valve
automatic valve that opens or closes from heat generated by the resistance of an
electrical component.
thermostatic expansion valve %SE!
controlling device for regulating flow of refrigerant into a cooling unit, actuated by the
changes in evaporator pressure and superheat of the refrigerant leaving the cooling
unit. %he basic response is to the superheat.
thermostatically controlled valve
valve in which the position of the plunger in relation to the seat is determined by the
deviation of temperature from the set value.
three2way valve
valve having either a single inlet and two outlets diverting! or two inlets and a single
outlet mixing!, in which either one or the other is open. &ervice valve for dualmounted
safety relief valves. &ee also diverting valve; mixing valve.
throttle valve
valve used to restrict throttle! the flow of fluid.
tulip valve
poppet valve whose conical head is tulip2shaped.
two2temperature valve evaporator pressure regulator!
bac$ pressure valve or constant pressure valve.
two2way valve
valve having a single inlet and single outlet. 4lso called throttle valve, shutoff valve,
stop valve.
two2way solenoid valve
valve actuated by a solenoid, a coil that surrounds a movable iron core that is pulled to
a central position with respect to the coil! when the coil is energi0ed by sending
electric current through it.
water valve
condenser2water regulator valve capable of regulating flow of water through a
condenser according to changes in condensing pressure or water temperature.
0one valve
valve that modulates water flow to a thermal 0one in response to a downstream
temperature signal.
valve area
variable area encountered by a fluid flowing through a valve.
valve body
shell or housing of a valve, into which the mechanism for regulating flow is fitted.
valve cage
device for holding and locating a valve dis$, poppet, etc. in relation to a valve seat.
valve cover
removable part which allows access to the valve mechanism.
valve dis$
dis$ or button fixed to the end of a valve stem and which meets the valve seat on
closure.
valve flutter valve bounce!
uncontrolled oscillation of a compressor valve on its seat during opening or closing.
valve guard
part which limits or controls the opening of a valve.
valve lift
vertical distance through which a valve is raised to allow the passage of a fluid.
valve plate
plate on which the valves of a reciprocating or rotary compressor are located.
valve plug
generic name for that part of a valve which mates with the seat to control or shut off
flow.
valve obturator
that part of a valve that closes off or stops fluid flow.
valve port
opening for passage of a fluid in a valve.
valve seat
stationary portion of the valve which, when in contact with the movable portion, stops
flow completely.
valve stem
spindle movable towards or away from a valve seat for guiding the valve head during
closing or opening.
valve trim
internal parts stem, plug, dis$, seat, etc.! of a valve.
vapor
1. substance in the gaseous state that can also exist as a liquid or solid at normal
atmospheric conditions. Compare gas.
2. gas, particularly one near equilibrium with its liquid phase and one that does not
follow the gas laws. %he term is usually used instead of gas to refer to a refrigerant,
or in general, to any gas below the critical temperature.
dry2saturated vapor saturated vapor!
vapor at the saturation temperature corresponding to the existing pressure and
without any liquid phase.
superheated vapor
vapor at a temperature greater than the saturation temperature. %he pressure and
temperature of superheated vapor are independent properties, since the temperature
can increase while the pressure remains constant. &ee superheat.
supersaturated vapor
vapor in a metastable equilibrium at a pressure higher than the saturation pressure
corresponding to its temperature. &ee supersaturation.
wet vapor
saturated vapor containing liquid droplets in suspension.
vapor barrier
use vapor retarder. &ee water2vapor retarder.
vapor control
1. control device with a vapor2charged power element.
2. method of control using the expansion and contraction forces of a contained vapor.
vapor loc$
formation of vapor in a liquid line that reduces mass flow compared to the flow of the
total liquid at the same pressure differential.
vapor loc$ device
orifice capillary tube, or other device having a restricted passage of fixed si0e for liquid
refrigerant. It restricts flow of vapor of that same liquid to a lower rate of flow with the
same pressure difference.
vapor pressure
pressure exerted by a vapor. If a vapor is $ept in confinement over its liquid or solid so
that the vapor can accumulate above the substance with the temperature constant, the
vapor pressure reaches a maximum called the saturated vapor pressure. 9ote: 6or a
specific liquid or solid, at constant volume of vapor above it, the vapor pressure
depends only on the temperature.
saturation vapor pressure
pressure at which vapor and liquid, or vapor and solid, can exist in equilibrium at a
given temperature.
vapor quality
ratio of the mass of vapor to the total mass when a substance exists as part liquid and
part vapor at the saturation temperature. 9ote: 3uality has meaning only when the
substance is in a saturated state, i.e., at saturation pressure and temperature.
vapor retarder
material or construction that adequately impedes the transmission of water vapor under
specified conditions.
vapori0ation
change of phase from liquid to vapor.
E41
unit of voltampere reactive power. 6or a two2wire circuit, the product of the voltage
times the current times the sine of the angular phase difference by which the voltage
leads or lags the current. E41s and watts combine in a quadrature to form voltamperes.
variable
anything which in concept or in practice is measurable or quantifiable, as a physical
variable such as pressure, length, voltage, power, enthalpy, temperature, speed.
B3uantityD often means variable but usually refers to an amount or numerical si0e.
B>arameterD can be variable during design but is constant after construction and during
use of equipment.
controlled variable
1. any variable that is controlled.
2. in a closed2loop system, variation in temperature, humidity, or pressure causes a
controller to respond, and to reduce the deviation from a desired value.
correcting variable
output from controlling device which inputs to the controlled element.
variable air volume E4E!
use of varying airflow to control the condition of air, in contrast to the use of constant
flow often! with varying temperature.
variable volume, variable temperature EE%!
combination of varying both airflow and temperature in response to space load, for the
purpose of resetting temperature to maintain greater low2load airflow to the space than
in a true variable volume system.
E4E
variable air volume.
E4E box
variable air volume terminal device.
parallel fan2powered E4E box
terminal device that combines a true E4E box in parallel with a fan and optional
heating coils. 6an operation is intermittent.
reheat E4E box
true E4E box with a reheat coil mounted on the discharge of the unit.
series fan2powered E4E box
terminal device that combines a true E4E box in series with a downstream fan and
optional heating coil. 6an operation is constant.
true E4E box
terminal device that regulates the amount of conditioned air entering a space. Control
typically is a function of space temperature.
velocity
1. time rate of distance moved.
2. vector quantity which denotes the simultaneous time rate and the direction of a linear
motion.
face velocity
velocity obtained by dividing the air quantity by the component face area.
mass velocity
ratio of the mass flow rate of a fluid in a pipe to the cross2sectional area of the pipe.
outlet velocity
average velocity of air emerging from an outlet measured in the plane of the outlet.
sonic velocity
maximum velocity of a gas or of a pressure wave in a liquid.
terminal velocity
velocity of an airstream at the end of the throw.
velocity pressure
1. in a moving fluid, pressure existing due to velocity and density of the fluid; expressed
as density times velocity squared, divided by two.
2. wind pressure.
velocity profile
graph that represents, in a plane section, the velocity distribution in a flowing fluid.
vena contracta
smallest area of a fluid stream leaving an orifice.
vent
1. opening in a tan$ or other piece of equipment, sealed to prevent escape of material
within at normal pressures, but arranged to open automatically to relieve excessive
pressure.
2. relief opening in a pressure regulator, normally open to the atmosphere.
#. air vent.
ventilating ceiling
multiple ceiling supply openings with vertical discharge, in close proximity to each other,
covering a significant part of the ceiling area and acting as a whole, not as individual
units.
ventilating rate air change rate!
number of complete air changes per unit time.
ventilation
process of supplying or removing air by natural or mechanical means to or from any
space. &uch air may or may not have been conditioned.
attic ventilation
introduction of cool outdoor air into an attic by exhausting its warm air to the outdoors.
cross ventilation
type of ventilating with air supply and exhaust points at opposite sides of ventilated
space.
underfloor ventilation
in a refrigerated vehicle or a cold room, the circulation of cold air beneath the load,
through a rac$ floor.
ventilation effectiveness Ev!
1. fraction of the outdoor that reaches the occupied 0one of the destined space.
2. evaluation of air delivery, regardless of the effectiveness of contaminant removal.
9ote: Eentilation effectiveness has a different name and operational definition
depending on the measurement procedure. &ee 4&<14= &tandard 12*.
ventilator
device for replacing air inside a room by outside air.
power ventilator roof or wall!
fan consisting of a centrifugal2or axial2type impeller with integral driver in a weatherresistant
housing with base designed to fit, usually by means of a curb, over a wall or
roof opening.
unit ventilator
fan2coil unit pac$age devised for applications in which the use of outdoor2 and returnair
mixing is intended to satisfy tempering requirements and ventilation needs.
venturi
contraction in a pipeline or duct that increases the fluid velocity to lower its static
pressure, followed by a gradual expansion to allow recovery of static pressure. 8sed for
metering and other purposes that involve change in pressure.
venturi tube
1. specially shaped constriction inserted in a pipe to measure the rate of flow from
induced changes in pressure in the constricted section.
2. specially shaped construction that creates a vacuum in a steam.water refrigeration
system.
vibration
oscillation in a mechanical system.
vibration cut2out switch
safety switch used to deenergi0e a principal circuit should the mechanical equipment
assembly vibrate excessively.
vibration isolation
external vibration isolation
in an air2handling unit, isolation of its vibration by devices external to the unit. 9ote:
=xamples are flex2duct connections, pipe2flex connections, and spring isolators.
internal vibration isolation
in an air2handling unit, spring2isolation of all moving parts within the unit that support
the fan sled. 9ote: %he fan2scroll discharge is typically isolated from the fan casing via
a flex connection and snubber springs, thus obviating the need for external vibration
isolation.
vibration isolation hanger
vibration isolator that is used to minimi0e vibration transmission into or out of a system
that is suspended from a supporting structure.
vibration isolation pad
vibration isolator using neoprene, rubber, precompressed fibrous glass, or similar
elastomer material.
vibration isolator
resilient support used to reduce the capacity of a system to respond to vibratory
excitation.
vibration snubber
device to restrain vibration or movement of pipes or equipment.
viscometer
instrument for measuring viscosity.
viscosity
1. property of semifluids, fluids, and gases by which they resist an instantaneous
change of shape or arrangements of parts. It causes fluid friction whenever ad"acent
layers of fluid move with relation to each other.
2. property of a fluid to resist flow or change of shape.
absolute viscosity dynamic viscosity!
force per unit area required to produce unit relative velocity between two parallel
areas of fluid unit distance apart, also called coefficient of viscosity.
$inematic viscosity
ratio of absolute viscosity to density of a fluid.
viscosity index
empirical number evaluated by comparing the viscosity of a substance with that of a
standard substance.
EFC
volatile organic compound.
volatile liquid
liquid that evaporates readily at atmospheric pressure and room temperatures.
volatile organic compounds EFC!
organic compounds in the vapor state present in an indoor atmosphere.
volt
unit of electrical potential, potential difference, or electromotive force emf!.
voltage
electric potential or potential difference expressed in volts.
common2mode voltage
signal of the same polarity and voltage on both wires of a differential input, often
caused by a common path.
design voltage
specific voltage for which a line or piece of equipment is designed. 4 reference level of
voltage for identification, and not necessarily the precise level at which it operates.
undervoltage
condition where voltage is lower than rated.
voltampere E4!
basic unit of apparent power. %he voltamperes of an electric circuit are the
mathematical product of the volts and amperes of the circuit. %he practical unit of
apparent power is $ilovolt2ampere $E4!, which is 1,,,, voltamperes.
volume.pressure control assembly box!
factory2made assembly for air distribution which, without altering the composition of the
treated air from the distribution system, manually or automatically controls velocity or
pressure of the air; or mixes airstreams of different temperatures and humidities, or
both.
EFA volt ohmmeter!
device for measuring voltage, or the resistance of an electrical circuit. &ome models
also measure current flow through components in electrical circuits.
vortex amplifier
fluidic control that throttles flow by causing a circular or vortex flow due to the impact of
a tangential control "et. 4mplification occurs when the control "et changes the vortex
flow more than the change of control flow.
EE%
variable volume, variable temperature.
wall section
cross section of wall, or a drawing of it, arranged to reveal thermal and moisture
migration characteristics.
wall sleeve
opening in a wall having a shroud insert to accept the chassis of an air2conditioning unit.
wall units heat! *either of two ma>or types+
1. electrical wiring embedded in glass or ceramic tile to radiate heat.
2. fixture recessed into a wall deep enough to enclose resistance coils and sometimes
fans. 9ote: %his term may apply also to gas heaters.
warming room food!
room designed to warm foodstuffs coming out of a cold room and thus avoid surface
condensation on produce.
warming2up allowance
addition to the capacity of a heating system as calculated for heat loss! to provide quic$
warmup in the morning.
watch dog timer
1. electronic internal timer which will generate a priority interrupt unless periodically
recycled by a computer. It is used to detect program stall or hardware failure
conditions.
2. time delay circuit which is closed when a computer system operates normally; when
the computer system goes off2line, the circuit will begin a time delay and then open
the circuit of which it is a part.
water
1. transparent, odorless, tasteless liquid; a compound of hydrogen and oxygen <2F!,
containing 11.1++G hydrogen and ++.+12G oxygen by mass; free0ing at #2)6 ,)C!;
boiling near 212)6 1,,)C!.
2. secondary coolant used in indirect refrigerating systems above #2)6 ,)C!.
brac$ish water
impure water with a lesser content of salt than seawater, but higher than that of
potable water.
chilled water
water used as a cooling medium particularly in air2conditioning systems or in
processes! at below ambient temperature.
circulating water
water that circulates repeatedly around a loop, used in a water2cooled device or in a
device that cools or heats water.
cooling water
water used for condensing a refrigerant.
domestic hot water
usually, potable hot water as distinguished from hot water used for house heating.
ma$eup water
water supplied to replenish the water of a system.
potable water
water that is drin$able.
process hot water
hot water needed for manufacturing processes over and above the domestic hot water
that is for the personal use of industrial wor$ers.
raw water
1. water used for ice ma$ing except distilled water.
2. untreated water.
releasable water
in free0e drying, that part of the water contained in the product which may be
extracted without spoiling the quality of the product.
soft water
water free of calcium and magnesium salts.
water column wc!
tubular column located at the steam and water space of a boiler to which protective
devices, such as gage coc$s, water gage, and level alarms are attached.
water contaminant
substance introduced into potable water thus creating a health ha0ard. Compare water
pollutant.
water draw rate
rate at which hot water is withdrawn from the system over a specified period at a
specified time.
water gage wg!
1. gage glass with attached fittings which indicates water level within a vessel.
2. designation that water is the fluid in a manometer.
water hammer
see hydraulic shoc$.
water heater
closed vessel in which water is heated by the combustion of fuels, electricity, or any
other source and is withdrawn for use external to the system at pressures not
exceeding 1-, psig ?11,, $>a gage!@, including the apparatus by which heat is
generated, and all controls and devices necessary to prevent water temperatures from
exceeding 21,)6 **)C!. &ee also boiler.
instantaneous water heater
water heater that is not a storage water heater or a heat pump water heater. Compare
storage water heater.
storage water heater
water heater that heats and stores water within the appliance at a thermostatically
controlled temperature, for delivery on demand. 9ote: 4&<14= &tandard *,.121*+*
requires that a storage water heater have an input rating of less than ',,, Itu.h per
gallon of stored water #1, K.C! or a storage capacity of 1, gallons #+ C! or more.
%his standard designates a nonstorage water heater, as one that has an input rating of
at least ',,, Itu.h per gallon of stored water #1, K.C!, and a storage capacity of
less than 1, gallons #+ C!.
tan$less water heater
heat exchanger for indirect heating of domestic water that is designed to be used
without a domestic water storage tan$. It may be attached directly to a boiler or
installed external to a boiler and connected by piping.
water2holding capacity
during a drying process, the ability of a substance to retain water.
water pollutant
substance introduced into potable water, thus creating an ob"ectionable condition, but
not creating a health ha0ard. Compare water contaminant.
water treatment
process that alters supply water so that it can be used for process or <E4C purposes
without deleterious effect.
water vapor
water in the vapor or gas phase.
mole fraction water vapor
in humid air, the ratio of the number of water2vapor moles to the total number of moles
in the mixture. Compare humidity.
water vapor content
in a gas, the mass of water vapor per unit mass of dry gas.
water vapor migration vapor transfer; vapor transmission!
transmission of water vapor through insulating or other material resulting from the
difference in partial pressures on both sides.
water vapor permeability
time rate of water2vapor transmission through unit area of flat material of unit thic$ness
induced by unit vapor pressure difference between two specific surfaces, under
specified temperature and humidity conditions. Khen permeability varies with
psychrometric conditions, the spot or specific permeability defines the property at a
specific condition. 9ote: >ermeability is a property of a material, but the permeability of
a body that performs li$e a material may be used. >ermeability is the arithmetic product
of permeance and thic$ness.
water vapor permeance
water vapor transmission of a body between two specified parallel surfaces, induced by
the vapor pressure difference between two surfaces. %he test conditions must be
stated. 4n accepted unit of water2vapor permeance is the perm. 9ote: >ermeance is a
performance evaluation and not a property of a material. &ee perm; rep.
water vapor pressure
1. the portion of atmospheric pressure exerted by entrained water vapor, at a specified
temperature.
2. pressure due to water vapor.
water2vapor resistance
steady vapor pressure difference that induces unit time rate of vapor flow through unit
area of a flat material or construction that acts li$e a homogeneous body! for specific
conditions of temperature and relative humidity at each surface. 9ote: Eapor resistance
is the reciprocal of vapor permeance. It is the arithmetic product of the resistivity and
thic$ness.
water2vapor resistivity
steady vapor pressure difference that induces unit time rate of vapor flow through unit
area and unit thic$ness of a flat material or construction that acts li$e a homogeneous
body!, for specific conditions of temperature and relative humidity at each surface.
Eapor resistivity is the reciprocal of vapor permeability.
water2vapor retarder
material or construction that adequately impedes the transmission of water vapor under
specified conditions.
water2vapor transmission rate KE%1!
steady2state vapor flow in unit time through unit area of a body, normal to specified
parallel surfaces, under specific conditions of temperature and humidity at each
surface.
waveform
shape of a wave plotted against time.
wax
in petroleum oils, a material, usually a solid hydrocarbon, that may separate on cooling
of an oil2refrigerant mixture.
wax content
wax contained in lubricating oil at a specified temperature.
wc
water column.
weber Kb!
unit of magnetic flux in the metre2$ilogram2second system, equal to the magnetic flux
which, lin$ing a circuit of one turn, produces in it an emf of 1 volt as it is reduced to 0ero
at a uniform rate in one second.
weld
locali0ed coalescence of metal produced by heating to a suitable temperature, with or
without application of pressure, and with or without the use of filler metal. 6iller metal
has a melting point approximately the same as the base metal.
butt weld
weld formed by placing two edges or ends one against the other, and welding them.
fillet weld
weld of approximately triangular cross section, "oining two surfaces approximately at
right angles in a lap "oint, tee "oint, corner "oint, or soc$et "oint.
lap weld
weld formed by lapping two pieces of metal and then pressing or hammering; applied
particularly to the longitudinal "oint produced by a welding process for tubes or pipe, in
which the edges of the s$elp are beveled or scarfed so that when they are overlapped
they can be welded together.
tac$ weld
weld made to hold parts of a weldment in proper alignment until final welds are made.
welding process
process used to "oin metals by the application of heat. 6usion welding, which includes
gas, arc, and resistance welding, requires that the parent metals be melted. %his
distinguishes fusion welding from bra0ing.
acetylene welding
welding using an acetylene2gas torch for fusing a selected metal welding rod! in such
a position as to fill the space where a "unction is to be made.
arc welding
group of welding processes wherein coalescence of metal is produced by heating with
an electric arc or arcs, with or without the application of pressure, and with or without
filler metal.
gas metal2arc welding MA4K!
arc2welding process wherein coalescence is produced by heating with an arc between
a continuous filler metal consumable! electrode and the wor$. 9ote: &hielding is
obtained entirely from an externally supplied gas or gas mixture.
gas tungsten2arc welding M%4K!
arc2welding process wherein coalescence is produced by heating with an arc between
a single tungsten nonconsumable! electrode and the wor$. 9ote: &hielding is
obtained from a gas or gas mixture. >ressure may or may not be added.
gas welding
group of welding processes wherein coalescence is produced by heating with a gas
flame or flames, with or without the application of pressure, and with or without the
use of filler metal.
resistance welding
welding with resistance heating and pressure, the wor$ being part of the electrical
circuit.
shielded metal2arc welding &A4K!
arc2welding process wherein coalescence is produced by heating with an electric arc
between a covered metal electrode and the wor$. 9ote: &hielding is obtained from
decomposition of the electrode covering. >ressure is not used and filler metal is
obtained from the electrode.
spot welding
welding of lapped parts in which fusion is confined to a relatively small circular area. It
is generally resistance welding, but may also be gas tungsten2arc, gas metal2arc, or
submerged2arc welding.
submerged arc welding
arc2welding process wherein coalescence is produced by heating an arc or arcs
between a bare metal electrode or electrodes and the wor$. 9ote: %he arc is shielded
by a blan$et of granular fusible material on the wor$. >ressure is not used, and filler
metal is obtained from the electrode and sometimes from a supplementary welding
rod.
thermit thermite! welding
welding with heat produced by the reaction of aluminum with a metal oxide. 6iller
metal, if used, is obtained from the reduction of an appropriate oxide.
weldment
assembly whose component parts are "oined by welding.
wind pressure velocity pressure!
total force exerted on a structure by wind.
wiredrawing
erosion of a valve plug or seat due to very high fluid velocity, usually caused by
prolonged operation in a nearly closed position.
wor$
mechanism that transfers energy across the boundary of systems with differing
pressures or force of any $ind!, always in the direction of lower pressure; if the total
effect produced in the system can be reduced to the raising of a weight, then nothing
but wor$ has crossed the boundary.
flow wor$
energy carried into or transmitted across the system boundary because a pumping
process occurs somewhere outside the system, causing fluid to enter the system.
6low wor$ also occurs as fluid leaves the system.
mechanical shaft! wor$
energy delivered or absorbed by a mechanism, such as a turbine, air compressor, or
internal combustion engine.
reversible wor$
maximum useful wor$ obtained for a given change of state. It includes heat supplied
from other systems, but excludes wor$ done on the surroundings.
wor$ cycle expander cycle; wor$ extraction cycle!
thermodynamic cycle in which the wor$ing fluid gives up mechanical energy to some
outside system e.g., in a mechanical expander!.
wor$ indicator
indicator diagram.
yield point
stress at which a material exceeds its elastic limit. Ielow this stress, the material will
recover its original si0e. 4bove this stress, it will not.
0eolite
group of aluminosilicates containing very loosely held cations, used in molecular sieves
and ion exchangers.
0eotrope
nona0eotropic liquid mixture that may be separated by distillation, and in which the
components are miscible in all proportions homogeneous 0eotrope!; or not miscible in
all proportions heterogeneous 0eotrope!.
0ero principle
if two systems are both in thermal equilibrium with a third one, they are in mutual
thermal equilibrium this principle is an introduction to the temperature concept!.
0one control 0one!
space or group of spaces within a building with heating or cooling requirements
sufficiently similar that comfort conditions can be maintained by a single controlling
device.
comfort 0one
1. operative temperature. &ee temperature. continued on next page!
2. range of effective temperatures under which most of a group of people feel
comfortable.
neutral 0one
see air infiltration building! neutral pressure level!.
occupied 0one
1. region in an occupied space between planes # and /2 inches /( and 1+,, mm!
above the floor, and more than 2 feet -,, mm! from the walls or fixed airconditioning
equipment.
2. in air conditioning, the space in which people, animals, and.or processes are
maintained.
0oning
1. division of a building or group of buildings into separately controlled spaces 0ones!,
where different conditions can be maintained simultaneously.
2. practice of dividing a building into smaller sections for control of heating and cooling.
=ach section is selected so that one thermostat can be used to determine its
requirements.
II. Math$'at!cs an# *hys!cs
><T&IC4C C4K&
7efinition: >hysical laws are properties of physical phenomena or relationships between
the various quantities or qualities that describe the phenomena and apply to all
members of a broad class.
4vogadroPs law
under the same conditions of pressure and temperature, equal volumes of all gases
contain equal numbers of molecules.
IaboPs law
addition of a nonvolatile solid to a liquid in which it is soluble, lowers the vapor pressure
of the solvent in proportion to the amount of substance dissolved.
IeerPs law
absorption of light by a solution changes exponentially with the concentration, all else
remaining the same.
IoylePs law
product of the volume of a gas times its pressure is a constant at fixed temperature.
4lso $nown as AariottePs law.
IrewsterPs law
index of refraction for a material is equal to the tangent of the polari0ing angle for the
material.
CharlesP law
at constant pressure, the volume of a fixed mass or quantity of gas varies directly with
the absolute temperature; a close approximation. 4lso $nown as May2CussacPs law.
combining weights law
if weights of elements that combine with each other are called their Bcombining
weightsD, then elements always combine either in ratio of their combining weights, or of
simple multiples of these weights.
component substances law
every material consists of one substance, or is a mixture of two or more substances,
each of which exhibits a specific set of properties, independent of the other substances.
compression exponent compression index!
exponent n in the equation pv n 5 constant, representing the actual pressure2volume
relationship during compression.
conservation2of2energy law
energy can neither be created nor destroyed, and therefore the total amount of energy
in the universe remains constant. &ee thermodynamics laws.
conservation of momentum law
when a system of masses is sub"ect only to internal forces that masses of the system
exert on one another, the total vector momentum of the system is constant.
CoulombPs law
the attraction or repulsion between two electric charges acts along the line between
them, is proportional to the product of their magnitudes, and is inversely proportional to
the square of the distance between them.
CuriePs law
magnetic susceptibilities of most paramagnetic substances are inversely proportional to
their absolute temperatures.
Curie2Keiss law
susceptibility of a paramagnetic substance above the Curie temperature varies
inversely as the excess of the temperature above that point.
7altonPs law
each constituent of a mixture of gases behaves thermodynamically as if it alone
occupied the space. %he sum of the individual pressures of the constituents equals the
total pressure of the mixture.
definite composition law
a given chemical compound always contains the same elements in the same fixed
proportions by weight. 4lso $nown as the definite proportions law.
distribution law
if a substance is dissolved in two immiscible liquids, the ratio of its concentration in each
is constant.
7ulong2>etit law
product of the specific heat per gram and the atomic weight of many solid elements at
room temperature has almost the same value, about -.# calories per degree Celsius
2-' L.H!.
fan laws
1. flow rate varies in direct proportion to fan speed rpm!.
2. flow rate varies in direct proportion to pitch diameter of the motor sheave.
6aradayPs laws of electrolysis
1. amount of any substance dissolved or deposited in electrolysis is proportional to the
total electric charge passed.
2. amounts of different substances dissolved or deposited by the passage of the same
electric charge are proportional to their equivalent weights.
6ic$Ps law
rate of diffusion of matter across a plane is proportional to the negative of the rate of
change of the concentration of the diffusing substance in the direction perpendicular to
the plane.
MrahamPs law
rate of diffusion of a gas is inversely proportional to the square root of its density.
<enryPs law
mass of a slightly soluble gas that dissolves in a definite mass of liquid at a given
temperature is nearly directly proportional to the partial pressure of that gas. %his holds
for gases that do not unite chemically with the solvent.
<oo$ePs law
within the elastic limit of any body, the ratio of stress to strain produced is constant.
ideal gas law perfect gas law!
the equation of state of an ideal gas is a good approximation to real gases at sufficiently
high temperatures and low pressures; that is, pE 5 1%, where p is the pressure, E is the
volume per mole of gas, % is the absolute temperature, and 1 is the gas constant.
HeplerPs laws
three laws describing the motions of planets in their orbits: the orbits of planets are
ellipses with the sun at the common focus; the line "oining a planet and the sun sweeps
over equal areas during equal intervals of time; the squares of the periods of revolution
of any two planets are proportional to the cubes of their mean distances from the sun.
HirchoffPs law
1. algebraic sum of the currents that meet at any point is 0ero.
2. in any closed circuit, the algebraic sum of the products of the current and the
resistance in each conductor in the circuit is equal to the electromotive force in the
circuit.
#. ratio of the emissivity of a heat radiator to the absorptivity of the same radiator is the
same for all bodies, depending on frequency and temperature alone, and is equal to
the emissivity of a blac$body.
HohlrauschPs law
when ioni0ation is complete, the conductivity of an electrolyte is equal to the sum of the
conductivities of the ions into which the substance dissociates
HundtPs law
optical absorption bands of a solution are displaced toward the red when its refractive
index increases because of changes in composition or other causes.
CambertPs law
1. illumination of a surface by a light ray varies as the cosine of the angle of incidence
between the normal to the surface and the incident ray.
2. luminous intensity in a given direction radiated or reflected by a perfectly diffusing
plane surface varies as the cosine of the angle between that direction and the normal
to the surface.
Cen0P law
an electromotive force emf! induced in a conductor is always in such a direction that
the current it would produce would oppose the change that causes the induced emf.
mass action law
rate of a chemical reaction for a uniform system at constant temperature is proportional
to the concentrations of the substances reacting. 4lso $nown as Muldberg and Kaage
law.
AoseleyPs law square
root of the frequency of an x2ray spectral line belonging to a particular series is
proportional to the difference between the atomic number and a constant which
depends only on the series.
multiple proportions law
if two elements form more than one compound, the weights of the first element which
combine with a fixed weight of the second element are in the ratio of integers to each
other.
9ewtonPs law of cooling
rate of heat flow out of an ob"ect by both natural convection and radiation is proportional
to the temperature difference between the ob"ect and its environment, and to the
surface area of the ob"ect.
9ewtonPs laws of motion
1. every body continues in its state of rest or of uniform motion in a straight line, except
insofar as it may be compelled to change that state by action of some outside force.
2. change of motion is proportional to force applied, and ta$es place in the direction of
the line of action of the force.
#. to every action there is always an equal and opposite reaction.
FhmPs law
direct current flowing in an electric circuit is directly proportional to the voltage applied to
the circuit; it is valid for metallic circuits and many circuits containing an electrolytic
resistance.
>ascalPs law
confined fluid transmits externally applied pressure uniformly in all directions, without
change in magnitude.
pump laws affinity laws for pumps!
1. with constant impeller diameter and variable speed, flow of a constant2gravity pump
varies directly with the speed change; head varies as the square of the speed
change; and power changes as the cube of the speed change.
2. with variable impeller diameter and constant speed, flow varies directly with the
diameter change; head varies as the square of the diameter change; and power
varies as the cube of the diameter change.
#. >ower varies directly with specific gravity or density changes of the fluid.
periodic law
properties of the chemical elements and their compounds are a periodic function of their
atomic weights.
1aoultPs law
molar weights of nonvolatile nonelectrolytes, when dissolved in a definite mass of a
given solvent under the same conditions, lower the solventPs free0ing point, elevate its
boiling point, and reduce its vapor pressure equally for all such solutes.
&nell laws of refraction
when light travels from one medium into another, the incident and refracted rays lie in
one plane with the normal to the surface; are on opposite sides of the normal; and ma$e
angles with the normal whose sines have a constant ratio to one another. 4lso $nown
as 7escartes laws of refraction.
&tefan2Iolt0mann law
total energy radiated from a blac$body is proportional to the fourth power of the
temperature of the body. 4lso $nown as the fourth power law.
&to$esP laws
1% at #ow )e#o$ities( the fri$tiona# for$e on a spheri$a# "ody mo)in' thro!'h a f#!id at
$onstant )e#o$ity is e,!a# to :  times the prod!$t of )e#o$ity( f#!id )is$osity( and radi!s
of the sphere%
2. wavelength of luminescence excited by radiation is always greater than that of the
exciting radiation.
thermodynamics laws:
6irst law
law of conservation of energy, which can be expressed as follows: heat and wor$ are
mutually convertible; or because energy can neither be created nor destroyed, the
total energy associated with an energy conversion remains constant.
&econd law
conversion of heat to wor$ is limited by the temperature at which conversion occurs.
%his can be expressed as the Carnot cycle efficiency, as %1 R %2!.%1, where %1 is
the higher temperature in )1 or H! where heat is absorbed, and %2 is the lower
temperature where heat is re"ected. &ee also conservation of energy.
KienPs displacement law
when the temperature of a radiating blac$body increases, the wavelength
corresponding to maximum energy decreases in such a way that the product of the
absolute temperature and the wavelength is constant.
KienPs radiation law
intensity of radiation emitted by a blac$body per unit wavelength, at that wavelength at
which this intensity reaches a maximum, is proportional to the fifth power of the
temperature.
=9MI9==1I9M >1I9CI>C=&
7efinition: 4n engineering principle is a comprehensive and fundamental engineering law,
doctrine, or assumption.
4rchimedes principle
a body immersed in a fluid undergoes an apparent loss in weight equal to the weight of
the fluid it displaces.
combining volumes principle
when gases ta$e part in chemical reactions, the volume of the reacting gases and those
of the products if gaseous! are in the ratio of small whole numbers, provided that all
measurements are made at the same temperature and pressure. 4lso $nown as
May2Cussac law.
Coriolis acceleration
1. acceleration which, when added to the acceleration of an ob"ect relative to a rotating
coordinate system and to its centripetal acceleration, gives the acceleration of the
ob"ect relative to a fixed coordinate system.
2. vector that is equal in magnitude and opposite in direction to that of the first definition.
Coriolis force
velocity2dependent pseudoforce in a reference frame that is rotating with respect to an
inertial reference frame; it is equal and opposite to the product of the mass of the
particle on which the force acts and its Coriolis acceleration.
6ermatPs principle
an electromagnetic wave ta$es a path that involves the least travel time when
propagating between two points.
CeChatelierPs principle
when an external force is applied to a system at equilibrium, the system ad"usts so as to
minimi0e the effect of the applied force.
uncertainty principle
accurate measurement of an observable quantity necessarily produces uncertainties in
the $nowledge of the values of other observables. 4lso $nown as <eisenberg
uncertainty principle; indeterminacy principle.
EanPt <offPs principle
if the temperature of interacting substances in equilibrium is raised, the equilibrium
concentrations of the reaction are changed, so that the products of that reaction which
absorb heat are increased in quantity, or if the temperature for such an equilibrium is
lowered, the products that evolve heat in their formation are increased in amounts.
CF=66ICI=9%&
7efinition: 4 coefficient is a factor in a mathematical product.
absorption coefficient
ratio of the radiant flux absorbed by a body to that incident upon it.
air discharge coefficient
ratio of the net area at vena contracta of air flowing through an orifice to the total free
area of the opening.
coefficient of performance CF>! performance coefficient!
1. ratio of the rate of net heat output to the total energy input expressed in consistent
units and under designated rating conditions.
2. ratio of the refrigerating capacity to the wor$ absorbed by the compressor per unit
time.
coefficient of performance heat pump!
ratio of the rate of heat delivered to the rate of energy input, in consistent units, for a
complete operating heat pump plant or some specific portion of that plant under
designated operating conditions.
coefficient of performance heat pump compressor!
ratio of the compressor heating effect heat pump! to the rate of energy input to the
shaft of the compressor, in consistent units, in a complete heat pump, under designated
operating conditions.
coefficient of performance refrigerating!
ratio of the rate of heat removal to the rate of energy input in consistent units, for a
complete refrigerating plant or some specific portion of that plant under designated
operating conditions. Compare energy efficiency ratio ==1!.
coefficient of performance refrigerating compressor!
ratio of the compressor refrigerating effect to the rate of energy input to the shaft of the
compressor, in consistent units, in a complete refrigerating plant, under designated
operating conditions.
compressibility coefficient compressibility factor!
coefficient required to correct the perfect gas equation when applied to real gases.
contraction coefficient
1. ratio of the minimum cross2sectional area of a "et of liquid discharging from an orifice,
to the area of the orifice.
2. ratio of the net orifice of the vena contracta of a fluid flowing through an orifice, to the
total free area of the opening.
convective film coefficient
constant of proportionality relating the convective rate of heat transfer at a surface to
the temperature difference across the air film on that surface.
degradation coefficient #7!
factor of efficiency loss due to cycling of the unit. It is the effect of the reduction in
performance under cycling operation.
diffusion coefficient
see mass diffusivity ratio!.
discharge coefficient
in the flow of fluids through no00les and orifices, the product of the velocity coefficient
and the contraction coefficient. &ee also air discharge coefficient.
drag coefficient
coefficient expressing the resistance encountered by a body when moving in a fluid.
expansion coefficient
change in length per unit length, or the change in volume per unit volume, per degree
change in temperature.
film coefficient
heat transferred between a surface and a fluid in unit time through unit area induced by
unit temperature difference.
flow coefficient
1. experimentally determined proportionality constant, relating the actual velocity of fluid
flow in a pipe, duct, or open channel to the theoretical velocity expected under
certain assumptions.
2. dimensionless number used in studying the power required by fans, equal to the
volumetric flow rate through the fan divided by the product of the rate of rotation of
the fan and the cube of the impeller diameter.
gas constant coefficient
1 in the perfect gas relation pE 5 m1%.
heat transfer coefficient overall coefficient of heat transfer!
see 82factor.
heat transfer radiation coefficient
an imaginary coefficient expressing the proportionality of radiant heat exchange
between two bodies to their temperature difference.
heat loss coefficient thermal storage!
rate at which heat is lost from the storage device per degree temperature difference
between the average temperature of the storage medium and the average temperature
of the surround.
resistance coefficient
1. dimensionless number used in the study of flow resistance, equal to the resistance
force in flow divided by one2half 1.2! the product of fluid density, the square of fluid
velocity, and the square of a characteristic length.
2. dimensionless group, equal to four times the 6anning friction factor. 4lso $nown as
7arcy2Keisbach coefficient; 7arcy number 1.
12value thermal resistance!
,!antity determined "y the temperat!re differen$e( at steady state( "etween two defined
s!rfa$es of a materia# or $onstr!$tion that ind!$es a !nit heat f#ow rate thro!'h a !nit
area% R 0 ⊗T2q%
shading coefficient
ratio of absorbed and transmitted solar heat relative to fenestration fitted with shading
devices to that occurring with unshaded single strength glass.
temperature index coefficient of thermal performance
ratio of the difference in temperature between the inside surface and the exterior
ambient to the difference in temperature between the inside ambient and the exterior
ambient across a component of the building envelope. %he coefficient can be used to
estimate the apparent thermal resistance of the component.
velocity coefficient
1. ratio of the actual velocity of gas emerging from a no00le to the velocity calculated
under ideal conditions; it is less than one because of friction losses.
2. ratio of the actual average fluid velocity in the vena contracta to the ideal fluid
velocity.
viscosity coefficient
force per unit area required to produce unit relative viscosity between two parallel areas
of fluid2unit distance apart.
CF9&%49%&
7efinition: 4 constant value is a value that does not change during a particular process.
dielectric constant
for an isotropic medium, the ratio of the capacitance of a capacitor filled with a given
dielectric to that of the same capacitor having only a vacuum as a dielectric.
gas constant
constant of proportionality appearing in the equation of state of an ideal gas, equal to
the absolute pressure of the gas times its molar volume divided by its absolute
temperature. 4lso $nown as the gas2law constant.
velocity constant
ratio of the rate of change of the input command signal to the steady2state error, in a
control system where these two quantities are proportional.
CTCC=&
7efinition: 4 cycle is a complete course of operation of wor$ing fluid bac$ to a starting
point, measured in thermodynamic terms functions!.
binary2vapor cycle
thermodynamic cycle relative to the varying condensing and evaporating temperatures
of a nona0eotropic mixture of two fluids.
Carnot cycle
ideal reversible thermodynamic cycle comprising two isothermal processes and two
adiabatic processes. It is representative of maximum theoretical conversion of heat
energy into mechanical energy. Compare reverse Carnot cycle. &ee second law of
thermodynamics thermodynamics laws!; Carnot cycle efficiency thermodynamics
laws!.
reverse Carnot cycle
refrigeration! conversion of wor$ to heat, where the ratio %2.%1 R %2! is the coefficient
of performance, and where %1 is the higher temperature in )1 or H! where heat is
re"ected, and %2 is the lower temperature where heat is absorbed. Compare second
law of thermodynamics thermodynamics laws!.
compressing cycle refrigeration!
refrigerating cycle comprising four principal stages: vapori0ation of refrigerant;
compressing of vapor; liquefaction of vapor; and expansion of liquid.
expander cycle wor$2extraction cycle; wor$ cycle!
thermodynamic cycle in which the wor$ing fluid transfers mechanical energy to some
outside system e.g., in a mechanical expander!.
1an$ine cycle
theoretical thermodynamic cycle used in steam engines comprising four principal
stages: 1! vapori0ation of water under high pressure, 2! expansion of steam, #!
condensation of steam, and '! pumping of the water bac$ to initial pressure.
refrigerating cycle
thermodynamic cycle of a system which transfers heat from a low2temperature reservoir
to a high2temperature reservoir.
reversible cycle
theoretical thermodynamic cycle, composed of a series of reversible processes.
standard rating cycle
refrigerating cycle as defined by standard conditions.
&tirling cycle
theoretical thermodynamic cycle comprising two isothermal processes and two
isochoric processes.
7IA=9&IF9C=&& 98AI=1&
7efinition: 4 dimensionless number is a ratio of various physical properties such as
density or heat capacity! and conditions such as flow rate or mass! of such nature that
the resulting number has no defining units of mass, rate, etc.
circulating number
dimensionless number n used to describe the amount of liquid feed in overfeed
refrigeration evaporators, expressing the ratio of liquid feed to the evaporating rate.
continued on next page!
&upplied with inlet quality of 1 5 , liquid overfeed evaporator, it is equal to the
reciprocal of the outlet quality, n 5 1.2.
dust2spot opacity index
number that expresses the relative dust accumulation on a dust2spot sampling target,
corrected for the nonlinearity of opacity increase at constant dust accumulation rate.
6ourier number
1. dimensionless number used in unsteady2state flow calculations, equal to the product
of the dynamic viscosity and a characteristic time divided by the product of the fluid
density and the square of a characteristic length.
2. thermal! dimensionless number used in calculation of unsteady2state heat transfer,
equal to the product of the thermal conductivity and a characteristic time, divided by
the product of the density, the specific heat at constant pressure, and the distance
from the midpoint of the body through which heat is passing to the surface. &ymbol
is 6o, 6o, or 96o.!
6roude number
1. dimensionless number used in studying the motion of a body floating on a fluid with
production of surface waves and eddies; equal to the ratio of the square of the
relative speed to the product of the acceleration of gravity and a characteristic length
of the body. &ymbol is 6r, 6r1, or 96r 1.!
2. dimensionless number equal to the ratio of the speed of flow of a fluid in an open
channel to the speed of very small gravity waves, the latter being equal to the square
root of the product of the acceleration of gravity and a characteristic length. &ymbol
is 6r2 or 96r 2.! &ee also gravity current.
densimetric 6roude number
dimensionless form of the second 6roude number 96r 2 or 6r2, expressing the ratio of
inertia of an incoming fluid to buoyancy force based on the difference in density
between the incoming and the existing ambient! fluid. &ee also gravity current.
Mraet0 number
dimensionless number used in calculation of streamline flow, equal to the mass flow
rate of a fluid times its specific heat at constant pressure, divided by the product of its
thermal conductivity and a characteristic length. 4lso spelled Mrat0 number. &ymbol is
M0, M0, or 9M0.!
Mrashof number
dimensionless number used in the calculation of free convection of a fluid caused by a
hot body, equal to the product of the fluidPs coefficient of thermal expansion, the
temperature difference between the hot body and the fluid, the cube of a typical
dimension of the body, and the square of the fluidPs density, divided by the square of the
fluidPs dynamic viscosity. 4lso $nown as free convection number. &ymbol is Mr, Mr
or 9Mr.!
Cewis number
dimensionless number equal to thermal diffusivity divided by mass diffusivity. &ymbol is
Ce, Ce, or 9Ce.!
Aach number
ratio of the speed of a body or of a point on a body with respect to the surrounding air or
other fluid, or the ratio of the speed of a fluid to the speed of sound in the medium.
&ymbol is A or 9Aa.!
Aargoulis number
see &tanton number.
9usselt number
dimensionless number used in calculation of forced convection, which gives a measure
of the ratio of total heat transfer to conductive heat transfer, equal to the heat transfer
coefficient times a characteristic length, divided by the thermal conductivity. &ymbol is
9u, 9u, or 99u.!
>eclet number
dimensionless number used in calculation of heat and mass transfer, consisting of the
mass velocity times a characteristic length and the specific heat at constant pressure,
divided by the thermal conductivity. &ymbol is >e, >e, or 9>e.!
>randtl number
1. dimensionless number used in calculation of diffusion in flowing systems, equal to the
$inematic viscosity divided by the molecular diffusivity. &ymbol is >r or >r.! 4lso
$nown as &chmidt number 1 &ymbol is &c, &c, or 9&c1.!
2. thermal! dimensionless number used in calculation of forced and free convection,
equal to the dynamic viscosity times the specific heat at constant pressure, divided
by the thermal conductivity.
1eynolds number
dimensionless number that is significant in the design of a model of any system in which
the effect of viscosity is important in controlling the velocities or the flow pattern of a
fluid; equal to the density of a fluid times its velocity times a characteristic length divided
by the fluid viscosity. &ymbol is 1e or 91e.! 4lso $nown as 7am$ohler number E
&ymbol is 7aE!. 4 1eynolds number above 2(,, indicates turbulent flow; less than
2(,,, streamlined flow.
inlet 1eynolds number
in thermal storage, volume flow rate leaving a diffuser per unit length divided by the
$inematic viscosity of the incoming fluid.
1ichardson number
dimensionless number used in studying the stratified flow of multilayer systems; equal
to the acceleration of gravity g times the density gradient of a fluid divided by the
product of the fluidPs density and the square of its velocity gradient at a wall. &ymbol is
91.!
sabin
dimensionless unit of acoustical absorption, equal to the equivalent sound absorption of
one square foot of a surface of unit absorptivity i.e., of 1 square foot of surface that
absorbs all incident sound energy!.
&chmidt number
dimensionless number consisting of the mass transfer coefficient times a characteristic
length, divided by the mass diffusivity. &ymbol is &c, &c, or 9&c.! &ee >randtl number.
&herwood number
dimensionless number consisting of the mass2transfer coefficient times a characteristic
length, divided by the mass diffusivity. &ymbol is &h, &h, or 9&h.!
&tanton number
dimensionless number used in calculation of forced convection, equal to the heattransfer
coefficient of a fluid, divided by the product of the specific heat at constant
pressure, the fluid density, and the fluid velocity. &ymbol is &t, &t, or 9&t.! 4lso $nown
as the Aargoulis number A.
&trouhal number
dimensionless number used in calculation of vibrations of a body past which a fluid is
flowing; equal to a characteristic dimension of the body times the frequency of
vibrations, divided by the fluid viscosity relative to the body. 6or a taut wire
perpendicular to the fluid flow, with the characteristic dimension ta$en as the diameter
of the wire, it has a value between ,.1+( and ,.2. &ymbol is &tr or &r.! 4lso $nown as
reduced frequency.
vapor concentration absolute humidity; water2vapor density number!
in a mixture of water vapor and dry air, the mass of water vapor in a specific volume of
the mixture. Compare relative humidity.
=66=C%&
7efinition: =ffect is a state of being operative.
barometric effect
variations in barometric pressure caused by altitude or weather changes.
chimney effect stac$ effect!
rising of air or gas in a duct or other vertical passage, as in buildings, induced when its
density is lower than that of surrounding air or gas.
Coanda effect
characteristic of an airstream that causes it to cling to the surface along which it flows.
%he velocity of the airstream as it passes along the surface generates low pressures.
%his action causes surrounding air to be aspirated.
compressor heating effect heat pump!
1. rate of heat delivery by the refrigerant assigned to the compressor in a heat pump
system equal to the product of the mass rate of refrigerant flow produced by the
compressor and the difference in specific enthalpies of the refrigerant vapor at
thermodynamic state leaving the compressor and saturated liquid refrigerant at the
pressure of the vapor leaving the compressor.
2. rate of heat delivery by the refrigerant assigned to the compressor in a heat pump.
compressor refrigerating effect
rate of heat removal by the refrigerant assigned to the compressor in a refrigerating
system. %his is equal to the product of the mass rate of refrigerant flow produced by the
compressor and the difference in specific enthalpies of the refrigerant vapor at its
thermodynamic state entering the compressor and refrigerant liquid at saturation
temperature corresponding to the pressure of the vapor leaving the compressor.
condenser heat re"ection effect condenser duty!
amount of heat energy re"ected to its surroundings by the condenser of a system.
cooling effect
sensible cooling effect
1. amount of sensible heat removed from air during cooling.
2. difference between total cooling effect and dehumidifying effect.
total cooling effect
1. difference between the total enthalpy of the dry air and the water2vapor mixture
entering mixture and leaving the cooler.
2. amount of sensible and latent heat removed from the conditioned space.
Coriolis effect
1. deflection relative to the earthPs surface of any ob"ect moving above the earth,
caused by the Coriolis force. 9ote: 4n ob"ect moving hori0ontally is deflected to the
right in the northern hemisphere, to the left in the southern.
2. the effect of the Coriolis force in any rotating system. 4lso called Coriolis deflection.
dehumidifying effect
mass of water condensed during cooling or the equivalent refrigerating capacity
expressed in terms of the latent heat of the water condensed per unit of time.
7oppler effect
change in the observed frequency of an acoustic or electromagnetic wave due to
relative motion of source and observer.
acoustical 7oppler effect
change in pitch of a sound observed when there is relative motion between source
and observer. 9ote: 1esults are different when the source moves relative to the
listener who is fixed in the medium atmosphere!, compared with the listener moving
relative to the source that is fixed.
optical 7oppler effect
change in the observed frequency of light or other electromagnetic radiation caused
by relative motion of the source and the observer. 9ote: %he frequency change does
not depend on whether it is the source or the observer that is moving.
radar 7oppler effect
shift of a radar echo due to relative motion of target and radar source. 9ote: 7oppler
radar can differentiate between fixed and moving targets, and can measure target
velocity.
<ilsch21anque effect
spot cooling effect produced in a tube into which gas is introduced tangentially
producing vortex flow.
humidifying effect
product of the mass of water evaporated times the latent heat at the evaporating
temperature.
Losephson effect
set of quantum2mechanical phenomena occurring when a current flows through an
electrically! wea$ lin$ or "unction connecting two superconductors, e.g., by tunneling
through a dielectric barrier, or by flowing through a sufficiently narrow constriction in a
superconducting material.
Loule2%homson effect
ratio of temperature change to pressure change d%.dp! of an actual gas in a process of
throttling or expansion without doing wor$ or interchanging heat.
>eltier effect
evolution or absorption of heat produced by an electric current passing across "unctions
of two suitable dissimilar metals, alloys or semiconductors.
refrigerating effect
in a refrigeration system, the rate of heat removal.
condensing unit refrigerating effect
rate of heat removal by the refrigerant assigned to the condensing unit in a
refrigerating system. %his is equal to the product of the mass rate of refrigerant flow
produced by the condensing unit and the difference in the specific enthalpies of the
refrigerant vapor entering the unit at a specified superheat, and the refrigerant liquid
leaving the unit at a specified subcooling.
cooler refrigerating effect
rate of heat absorption by a refrigerating medium flowing through a cooler air, water,
brine, etc.! at stated conditions. It is measured as the product of the mass flow rate of
the refrigerating medium and the difference in specific enthalpies of the refrigerating
medium entering and leaving the cooler.
refrigerant heat re"ection effect
condensing heat re"ection effect
portion of the total refrigerant heat re"ecting effect of a condenser which is used for
condensing the entering refrigerant vapor to a saturated liquid at the entering
refrigerant pressure.
subcooling heat re"ection effect
total refrigerant heat re"ection effect less the condensing heat re"ection effect.
total refrigerant heat re"ection effect
total useful capacity of a refrigerant condenser for removing heat from the refrigerant
circulated through it.
refrigerating effect
rate of heat removal by the refrigerant.
net refrigerating effect
1. rate at which heat is removed by the primary refrigerant from the cooling medium
secondary coolant! that is used to transmit the refrigerating effect.
2. brine cooler! product of the mass rate of water or brine flow and the difference in
enthalpy of the entering and leaving water or brine expressed in heat units per unit
of time. It is expressed also by the total refrigeration effect less the heat lea$age
losses.
#. condensing unit capacity! rate at which heat is removed from outer media by a
refrigerant in the low pressure side, or by the difference in total enthalpy between
refrigerant liquid leaving the unit and the total enthalpy of the refrigerant vapor
entering it.
'. pac$aged air conditioners! rate at which heat is removed from the airstream, as
measured entering the cooling coil and leaving the unit.
subcooling refrigerating effect
additional refrigeration effect made available by subcooling the refrigerant liquid in the
condenser.
system refrigerating effect
rate of heat removal by the refrigerant in the evaporator of a refrigerating system.
total refrigerating effect water or brine cooler!
product of the mass rate of refrigerant flow and the difference in enthalpy of the
entering and leaving refrigerant fluid, expressed in heat units per unit of time.
useful refrigerating effect
rate at which heat is removed by the primary refrigerant, or by the secondary
refrigerant, between two specified points, ta$ing into account the conditions of use.
&eebec$ effect
generation of an electromotive force emf! induced by a difference in temperature at the
"unctions of two dissimilar materials selected for their emf characteristics and
temperature limits.
sun effect solar heat gain!
solar energy flowing into a building, through both windows and structural materials.
surface effect
effect caused by entrainment of secondary air when an outlet discharges air directly
against, or parallel to, a wall or ceiling.
system effects
conditions in a distribution system that affect fan and pump performance and related
testing, ad"usting, and balancing wor$.
=66ICI=9CT
7efinition: =fficiency is the ratio of the energy output to the energy input of a process or a
machine. &ee also volumetric efficiency.
adiabatic efficiency
1. efficiency with which wor$ is done with respect to heat gains or losses.
2. indicated efficiency! ratio of the wor$ absorbed in compressing a unit mass of
refrigerant in a compressor to the wor$ absorbed in compressing the same mass in
an ideal compressor. &ee isentropic process.
air2to2air energy recovery system efficiency
ratio of the apparent heat recovered to the sum of the thermodynamically limited
maximum possible in a counterflow heat exchanger of infinite heat2transfer area; plus
all external energy inputs including, but not limited to, fan energy, auxiliary heaters,
cross2lea$age, and casing loss. 9ote: %his ratio ad"usts heat2exchanger effectiveness
for auxiliary energy inputs of the energy recovery system.
Carnot cycle efficiency
conversion of heat to wor$, which is limited by the temperature at which conversion
occurs as %1 R %2!.%1, where %1 is the higher absolute temperature where heat is
absorbed and %2 is the lower absolute temperature where heat is re"ected.
compression efficiency
ratio of wor$ required to compress, adiabatically and reversibly, all the vapor delivered
by a compressor per stage! to the actual wor$ delivered to the vapor by the piston or
blades of the compressor.
effective efficiency
1. overall efficiency.
2. ratio of the wor$ absorbed in conveying and compressing a unit mass of refrigerant in
a perfect compressor and the wor$ absorbed, per unit mass of refrigerant, by the
shaft of an actual compressor.
filter separation efficiency
ratio of the mass of particles extracted to the mass of particles contained in the air
before filtering.
fin efficiency
ratio of heat actually transferred by a fin to heat transferred if the whole fin were at the
temperature of the primary surface to which it is attached.
mechanical efficiency
ratio of the compression energy or wor$ of a compressor to the energy or wor$ input.
operating efficiency
ratio of output to input.
overall system efficiency
ratio of the useful energy at the point of use to the thermal energy input over a
designated time period.
total2to2static efficiency static efficiency!
in a turbocompressor, the ratio of the variation of enthalpy of an isentropically
compressed vapor to the wor$ to be effectively supplied to the compressor the
enthalpy relating to the total pressure of the fluid at inlet and the static pressure at
outlet!.
total2to2total efficiency stagnation efficiency!
in a turbocompressor, the ratio of the variation of enthalpy of the vapor isentropically
compressed from the total pressure at inlet to the total pressure at outlet, to the wor$
effectively supplied to the compressor.
volumetric efficiency
ratio of volume induced, at suction conditions, by a compressor in a given time to the
swept volume as measured over the same time.
apparent volumetric efficiency
on an indicator card, the ratio of suction line length to stro$e.
volumetric efficiency due to cylinder heating!
ratio of the total to the apparent volumetric efficiency. 4lso called real or no2clearance
volumetric efficiency.
volumetric total efficiency
ratio of the actual volume of gas moved by the compressor or pump to actual
displacement of the compressor or pump.
=384%IF9&
7efinition: 4n equation is a statement that each of two mathematical expressions is equal
to the other.
Colburn heat transfer equation
dimensionless heat transfer equation used in calculating natural convection movement
of heat from vertical surfaces or hori0ontal cylinders to fluids gases or liquids! flowing
past these surfaces. %he symbol is "<.
Colburn mass transfer equation
dimensionless mass transfer equation consisting of the &herwood number divided by
the 1eynolds number and the &chmidt number to the 1.# power. %he symbol is "7.
64C%F1&
7efinition: 4 factor is a quantity by which a given quantity is multiplied or divided in order
to indicate a difference in measurement.
air transport factor
ratio of the rate of useful, sensible heat removal from the conditioned space to the
energy input to the supply and return fan motors!, expressed in consistent units and
within designated operating conditions.
ballast factor
ratio of commercial electric ballast lamp lumens to a reference ballast lamp lumens,
used to correct the lamp lumen output from rated to actual.
C2factor thermal conductance!
time rate of steady2state heat flow through a unit area of a material or construction
induced by a unit temperature difference between the body surfaces. C 5 q.⊗%.
capacity factor of a machine, equipment, or thermal storage!
ratio of the average load required, in the period of time considered, to the capacity in
mass, volume, or energy terms. 1eciprocal of storage factor.
cooling load factor CC6!
ratio of the total cooling of a complete cycle for a specified period consisting of an F9
time and F66 time to the steady2state cooling done over the same period at constant
ambient conditions.
demand factor electric!
ratio of the maximum electric demand to the connected load, usually monthly or
annually. &ee also electric power load factor.
diversity factor
ratio, or percentage, obtained when the total output capacity of a system is divided by
the total output capacity of all the terminal devices connected to the systems. =xample:
%o express the ratio of E4E supply air fan capacity to the total capacity of the E4E
terminal devices as a percentage.
electric power factor >6!
1. ratio of real power $K! to apparent power $E4! at any given point and time in an
electrical circuit. Menerally expressed as a percentage.
2. factor equal to the cosine of the phase angle between voltage and current, by which
the product of voltage and current is multiplied to convert volt2amperes to power in
watts.
electric power load factor
ratio of average load in $ilowatts supplied during a designated period to the pea$ or
maximum load in $ilowatts occurring in that period.
energy factor
measure of overall efficiency in terms of energy output compared to energy
consumption over a 2'2hour usage cycle.
factor of safety
ratio of a normal wor$ing condition to the ultimate condition, such as, in strength of
materials, ratio of wor$ing stress to ultimate strength.
friction factor
1. any of several dimensionless numbers used in studying fluid friction in pipes, equal to
the 6anning friction factor times some dimensionless constant.
2. coefficient used to calculate friction forces due to fluid flow.
#. quotient of the tangential force exerted by a fluid on a surface per unit area! by half
the product of the density and the square of the velocity.
6anning friction factor
dimensionless number f used in studying fluid friction in pipes, equal to the pipe
diameter times the drop in pressure in the fluid due to friction as it passes through the
pipe, divided by the product of the pipe length and the $inetic energy of the fluid per unit
volume.
heating load factor <C6!
ratio of the total heating of a complete cycle for a specified period consisting of an F9
time and F66 time to the steady2state heating done over the same period at constant
ambient conditions.
heating seasonal performance factor <&>6!
ratio of the total heat delivered over the heating season not to exceed 12 months! to
the total energy input over the heating season, in consistent units.
heat loss coefficient
rate at which heat is lost from a storage device per degree temperature difference
between the average storage medium temperature and the average ambient air
temperature or ground temperature, if the storage device is buried!.
$2factor thermal conductivity!
time rate of steady2state heat flow through a unit area of a homogeneous material
induced by a unit temperature gradient in a direction perpendicular to that unit area.
8nits are Itu in.hO ft2O)6, Itu.hO ft O)6, or K.mOH!.
load factor
ratio of actual mean load to a maximum load or maximum production capacity in a given
period. &ee electric power load factor; cooling load factor; heating load factor.
performance factor
ratio of the useful output capacity of a system to the input required to obtain it. 8nits of
capacity and input need not be the same. &ee coefficient of performance.
refrigerating system performance factor
ratio of the useful refrigerating effect of the system to the power input.
roughness factor
ratio of si0e of pro"ections from the surface of a pipe or duct, to the diameter of the pipe
or duct.
storage factor
1. reciprocal of capacity factor.
2. ratio of the volume occupied by the quantity of a particular product stored to the
maximum that can be stored, ta$ing into account the requirements of that particular
product.
82factor thermal transmittance!
heat transmission in unit time through unit area of a material or construction and the
boundary air films, induced by unit temperature difference between the environment on
each side. 9ote: %his heat transmission rate has been called the overall coefficient of
heat transfer.
K2factor
82factor converted into electrical terms for calculations in electric heating. %he amount
of heat flow expressed in watts per square foot per degree 6ahrenheit temperature
difference between air on the inside and air on the outside of the building section wall,
floor, roof, or ceiling!. 6or conversion, K 5 ,.2*# 8, where 8 is in Itu.hO ft2O)6.
I97=S=&
7efinition: 4n index is a numerical quantity, usually dimensionless, denoting the
magnitude of some physical effect, such as the refractive index.
air diffusion performance index 47>I!
single number rating of the air diffusion performance of a system of diffusers, as
installed, at a specified air delivery rate and space load.
comfort index
index combining the properties of an environment for evaluating the sensation of
comfort of occupants; equal to 1( plus ,.' times the sum of the dry2bulb and wet2bulb
temperatures in degrees 6ahrenheit. &ee also thermal comfort.
dust2spot opacity index
number which expresses the relative dust accumulation on a dust2spot sampling target,
corrected for the nonlinearity of opacity increase, at constant dust2accumulation rate.
freshness index sensory index!
usually a *2point! scale of sub"ective assessment of the purity of air by occupants.
opacity index
see dust2spot opacity index.
temperature index
see temperature index coefficient of thermal performance.
viscosity index EI!
1. empirical number evaluated by comparing the viscosity of a substance with that of a
standard substance.
2. characteristic of lubricating oil that indicates the change in viscosity with temperature;
i.e., a high EI oil has less change in viscosity with temperature change, than a lower
EI oil.
Kobbe index
number which indicates interchangeability of fuel gases, obtained by dividing the
heating value of a gas by the square root of its specific gravity.
14%IF&
7efinition: 4 ratio of two quantities or mathematical ob"ects 4 and I is their quotient or
fraction 4.I.
air2gas ratio
ratio of the air volume to the gas volume. 4 specified ratio is necessary to achieve a
desired character of combustion.
air2mass ratio
ratio of the mass of atmosphere in the actual earth2sun path to the mass which would
exist at sea level if the sun were directly overhead.
air2to2air energy recovery effectiveness
ratio of actual heat transfer to the thermodynamically limited maximum heat transfer
possible in a counterflow exchanger of infinite transfer area. 9ote: =ffectiveness may be
stated as total, sensible, or latent when the ratio defined above uses these heats as the
actual and maximum possible heat2transfer quantities.
aspect ratio
1. in any rectangular configuration, the ratio of the longer dimension to the shorter.
2. ratio of the length to width of a rectangular air duct.
blast area ratio
blast area divided by the fan outlet area.
compression ratio
ratio of the absolute pressure after compression to the absolute pressure before
compression.
compression volume ratio
ratio of volume of compression chamber at inta$e of gas to volume at discharge in
positive displacement compressors.
compressor volume ratio
ratio of volume of compression chamber at inta$e of refrigerant gases to the volume at
discharge in positive displacement compressors.
concentration ratio
1. ratio of the quantity of one constituent to the total mixture.
2. process in which the proportion of a substance is increased.
cooling efficiency ratio C=1!
ratio calculated by dividing the total cooling capacity in Itu.h by the total power input in
watts excluding heaters and humidifiers! at any given set of rating conditions,
expressed in Itu.h per watt.
standard cooling efficiency ratio &C=1!
ratio calculated from the capacity and power input values obtained at standard rating
conditions.
desiccation ratio
in free0e2drying, ratio of the mass of the substance resulting from a free0e2drying
process to the mass of the original product.
dryness ratio
in free0e2drying, ratio of the mass of dry matter to the mass of fro0en substance.
effectiveness ratio of a heat exchanger!
ratio of the actual heat transfer to the thermodynamically limited maximum heat transfer
possible in a counterflow exchanger of infinite transfer area.
efficiency ratio!
ratio of the energy output to the energy input of a process or a machine. &ee also
volumetric efficiency.
energy efficiency ratio ==1!
ratio of net cooling capacity in Itu.h to the total rate of electric input in watts, under
designated operating conditions. &ee also coefficient of performance CF>!.
energy transmittance ratio transmission factor; transmittivity!
ratio of the energy flow rate traversing a body to the energy flow rate it receives by
radiation. &ee thermal transmittance.
entropy ratio!
ratio of the heat absorbed by a substance to the absolute temperature at which it was
added.
specific entropy
entropy per unit mass of a substance.
induction ratio entrainment ratio in air diffusion!
ratio of total primary plus secondary! air to primary air.
load diversity ratio!
in a thermal storage system, the ratio of average daily load to maximum capacity. 4
1,, $K chiller meeting an average load of /( $K would have a diversity of ,./(.
mass diffusivity ratio! diffusion coefficient!
ratio of the mass flow of a substance diffusing through a surface of unit area to the rate
of variation in the concentration of this substance normal to this surface.
seasonal energy efficiency ratio, cooling &==1!
total cooling output of an air conditioner during its normal annual usage period for
cooling, in Itu.h, divided by the total electric energy input during the same period, in
watt2hours.
sensible heat ratio
ratio of the sensible heat to the sensible plus latent heat to be removed from a
conditioned space.
sensitivity ratio!
in instrumentation, ratio of a change in output magnitude to the change of input that
causes it, after the steady state has been reached.
specific infiltration ratio!
ratio of infiltration to lea$age area; a normali0ed quantity that indicates the intensity of
the weather relative to infiltration.
vane ratio
in air2distributing devices, the ratio of the depth of vane to shortest opening width
between two ad"acent bars in a grille.
vapor content ratio!
ratio of the amount of vapor present compared to the amount present at saturated
conditions.

Sponsor Documents

Or use your account on DocShare.tips

Hide

Forgot your password?

Or register your new account on DocShare.tips

Hide

Lost your password? Please enter your email address. You will receive a link to create a new password.

Back to log-in

Close