ABOUT US

Being a subsidiary of a leading Group worldwide means to benefit from its notoriety and its power; It means to emphasize its regional and cultural characteristics as well as its own competences and its flexibility; It also means to be conscious of our responsibility toward future generations and bring our own contribution however modest it may be, to the durable development of our planet. As the French subsidiary of KATHREIN Group, it is our responsibility and our priority to always serve and develop the best Telecom solutions that match the needs of the different actors within the mobile market. Being totally aware of the fast evolutions and the growing needs of the MiddleEast and African mobile market, KATHREIN France now offers complete aerial solutions to mobile operators and installation companies. Our know-how, our export-related experience, our technical support, as well as our ability to react immediately are the key assets which all together make us able to answer, as perfectly as possible, your needs. We are also able to be at your side for your network and all your projects of sites roll-out, extension or optimization. Apart from Base Station Antennas for Mobile Networks, KATHREIN FRANCE also supplies RF equipment (feeder cables, coaxial connectors and jumpers), RF accessories (for aerials, clamps for feeder cables, cable trays, tools etc..), RF protections against lightning, as well as solutions for weatherproofing and isolation. KATHREIN FRANCE Export Team hopes that this new brochure “Cables, Connectors and RF Accessories 2011” will bring you whole satisfaction.

2

Quality & Environmental certificates

3

PRODUCTS REFERENCES
Description
FEEDERS FEEDER 1/2’’ HIFLEX FEEDER 1/2’’ RIGID NEW FEDEER 7/8’’ ULTRA LOW LOSS NEW FEEDER 1-1/4’’ ULTRA LOW LOSS NEW FEEDER 1- 5/8’’ ULTRA LOW LOSS CONNECTORS COAX. 7/16 MALE RIGHT 1/2’’ FLEXIBLE 7/16 FEMALE RIGHT 1/2’’ FLEXIBLE 7/16 MALE RIGHT ANGLE 1/2’’ FLEXIBLE 7/16 MALE 1/2’’ RIGID 7/16 FEMALE RIGHT 1/2’’ RIGID 7/16 MALE RIGHT ANGLE 1/2’’ RIGID 7/16 MALE RIGHT 7/8’’ RIGID 7/16 FEMALE RIGTH 7/8’’ RIGID 7/16 MALE RIGHT 7/8’’ 7/16 FEMALE RIGHT 7/8’’ 7/16 FEMALE RIGHT 1- 1/4’’ 7/16 MALE RIGHT 1- 5/8’’ 7/16 FEMALE RIGHT 1- 5/8’’ JUMPERS 7/16 MALE RIGHT/MALE RIGHT 0,50m HIFLEX 7/16 MALE RIGHT/MALE RIGHT 1m HIFLEX 7/16 MALE RIGHT/MALE RIGHT 1,5m HIFLEX 7/16 MALE RIGHT/MALE RIGHT 2m HIFLEX 7/16 MALE RIGHT/MALE RIGHT 2,5m HIFLEX 7/16 MALE RIGHT/MALE RIGHT 3m HIFLEX 7/16 MALE RIGHT/MALE RIGHT 4m HIFLEX 7/16 MALE RIGHT/MALE RIGHT 5m HIFLEX 7/16 MALE RIGHT/MALE RIGHT ANGLE 0,50m HIFLEX 7/16 MALE RIGHT/MALE RIGHT ANGLE 1m HIFLEX 7/16 MALE RIGHT/MALE RIGHT ANGLE 1,50m HIFLEX 7/16 MALE RIGHT/MALE RIGHT ANGLE 2m HIFLEX 7/16 MALE RIGHT/MALE RIGHT ANGLE 2,50m HIFLEX 7/16 MALE RIGHT/MALE RIGHT ANGLE 3m HIFLEX 7/16 MALE RIGHT/MALE RIGHT ANGLE 4m HIFLEX 7/16 MALE RIGHT/MALE RIGHT ANGLE 5m HIFLEX 7/16 MALE RIGHT/MALE RIGHT 0,50m RIGID 7/16 MALE RIGHT/MALE RIGHT 1m RIGID 7/16 MALE RIGHT/MALE RIGHT 1,5m RIGID 7/16 MALE RIGHT/ MALE RIGHT 2m RIGID 7/16 MALE RIGHT/MALE RIGHT 2,5m RIGID 7/16 MALE RIGHT/MALE RIGHT 3m RIGID 7/16 MALE RIGHT/MALE RIGHT 4m RIGID 7/16 MALE RIGHT/MALE RIGHT 5m RIGID CABLE PREPARATION TOOL 1/2’’ FLEXIBLE 1/2’’ RIGID 7/8’’ 1- 1/4’’ 1- 5/8’’ 960 085 960 084 960 064 960 123 960 086 p 19 p 19 p 19 p 19 p 19 961 005 961 010 961 015 961 020 961 025 961 030 961 040 961 050 961 505 961 510 961 515 961 520 961 525 961 530 961 540 961 550 962 005 962 010 962 015 962 020 962 025 962 030 962 040 962 050 p 14 p 14 p 14 p 14 p 14 p 14 p 14 p 14 p 14 p 14 p 14 p 14 p 14 p 14 p 14 p 14 p 15 p 15 p 15 p 15 p 15 p 15 p 15 p 15 CRA05692 CRA05082 CRA05206 CRA05982 CRA05706 CRA05216 CRA05717 CRA05718 CRA05720 CRA05721 CRA05719 CRA05287 CRA05286 p 13 p 13 p 13 p 13 p 13 p 13 p 13 p 13 p 13 p 13 p 13 p 13 p 13 CFC05019 CFC05004 CFC05041 CFC05040 CFC05034 p8 p9 p 10 p 11 p 12

References

pages
1/2’’ 7/8’’ 1- 1/4’’ 1- 5/8’’

Description
WRENCH HANDLES FOR CONNECTORS

References
950 002 950 003 950 004 950 001

pages
p 20 p 20 p 20 p 20

CLAMPS FOR FEEDERS CLIP FOR FEEDER 1/2’’ ON PYLON A CORNIERE CLIP FOR FEEDER 1- 1/4’’ ON PYLON A CORNIERE CLIP FOR FEEDER 1- 5/8’’ ON PYLON A CORNIERE 1 FEEDER 1/2’’ HANGING ON FLAT AND ROUND 1 FEEDER 7/8’’ HANGING ON FLAT ET ROUND 1 FEEDER 1- 5/8’’ HANGING ON FLAT AND ROUND 1 FEEDER 1- 1/4’’ HANGING ON FLAT AND ROUND 2 FEEDERS 1/2’’ HANGING ON FLAT AND ROUND 2 FEEDERS 7/8’’ HANGING ON FLAT AND ROUND 2 FEEDERS 1- 5/8’’ HANGING ON FLAT AND ROUND 2 FEEDERS 1- 1/4’’ HANGING ON FLAT AND ROUND 3 FEEDERS 1/2’’ HANGING ON FLAT AND ROUND 3 FEEDERS 7/8’’ HANGING ON FLAT AND ROUND 3 FEEDERS 1- 5/8’’ HANGING ON FLAT ET ROUND 3 FEEDERS 1- 1/4’’ HANGING ON FLAT AND ROUND 6 FEEDERS COAX. 7/8’’ HOISTING GRIPS PRE LACED FOR 1/2’’ PRE LACED FOR 7/8’’ PRE LACED FOR 1- 5/8’’ PRE LACED FOR 1- 1/4’’ WEATHERPROOFING JUMPERS/ANTENNAS & FEEDERS/JUMPERS 1/2’’ JUMPER TO 7/8’’ FEEDER 1/2’’ JUMPER TO 1- 1/4’’ FEEDER 1/2’’ JUMPER TO 1- 5/8’’ FEEDER KITS D’ETANCHEITE RUBAN BUTYL (0,50 m x 28 mm) & PLASTIC ELECTRICAL SCOTCH (10 m x 15 mm) COLLAR COLSON NON LOOSENING BLACK THROUGH JOINT 357 x 9 100 PIECES BOX IN POLYAMID 12 UNIVERSAL EARTHING KIT UNIVERSAL FOR FEEDER COAX 1/2’’ TO 7/8’’ SPECIFICALLY FOR FEEDER 7/8’’ SPECIFICALLY FOR FEEDER 1- 5/8’’ SPECIFICALLY FOR FEEDER 1- 1/4’’ BTS PROTECTION EMP PROTECTION 900/1800/UMTS GROUNDING BAR GROUNDING BAR STAINLESS STEEL AISI 3004 (V2A) OU CUIVRE 9 X M8 ROAD OF CHAINAGE FULL KIT : LIGHTNING ARRESTER, FLOW AND CROW’SFOOT CONNECTOR HOLE ENTRIES MODULE 6x2 7/8’’ + STUFFING CAC p 27 REF TO ASK FOR p 37 960 054 p 30 CRA05255 p 33 921 060 921 061 921 020 921 062 p 31 p 32 p 32 p 32 CAC05185 p 26 CAC05346 p 23 CAC05347 CAC05348 CAC05350 CAC05351 p 22 p 22 p 22 p 22 950 010 950 011 950 012 REF TO ASK FOR p 18 p 18 p 18 960 053 960 088 960 087 CAC05300 CAC05301 REF TO ASK FOR REF TO ASK FOR REF TO ASK FOR CAC05302 CAC05303 REF TO ASK FOR REF TO ASK FOR CAC05304 REF TO ASK FOR CAC05315 CAC05311 p 25 p 25 p 25 p 25 p 25 p 24 p 24 p 24 p 25 p 25

4

TABLE OF CONTENTS

IINDEX : Product References

Page 04

TABLE OF CONTENTS

Page 05

First Part : RF Equipment Hiflex Feeder cable 1/2” Rigid Feeder Cable 1/2” Feeder cable 7/8” Ultra-Low Losses Feeder cable 1-1/4” Ultra-Low Losses Feeder cable 1-5/8” Ultra-Low Losses Coaxial Connectors Hiflex Jumpers Rigid Jumpers Second Part : RF Accessories Hoisting Grips Stripping Tools Wrench Handles for Connectors Instructions to use Stripping Tools Protection of connections Weatherproofing Kit Snap-in Hangers for Feeder Cables from 1/2” to 5/8” Self-Locking Cable Clamps for 1, 2, 3, 4 and 6 Feeder Cables Cables Ties Wall Entries Third Part : Protection of RF Equipment Copper Grounding Bar Universal Earthing Kit Earthing Kits for 1/2», 7/8”, 1-1/4” and 5/8” Feeder Cables Lightning Arrester for GSM 900, 1800, and UMTS Lightning Arrester : Installation Instructions Basic Information for a safe Cell Site Protection of equipment upper extremities Cell Sites suffering from Lightning : How to provide a safe flow path for the lightning current

Page 06/07 Page 08 Page 09 Page 10 Page 11 Page 12 Page 13 Page 14 Page 15 Page 16/17 Page 18 Page 19 Page 20 Page 21 Page 22 Page 23 Page 24 Page 25 Page 26 Page 27 Page 28/29 Page 30 Page 31 Page 32 Page 33 Page 34 Page 35 Page 36 Page 37

5

RF

The deployment of base stations requires feeder cables and coaxial connectors of high quality to reduce insertion losses as much as possible, to get the best signal transmission. KATHREIN FRANCE feeder cables are designed to provide you the best electrical results and a higher longevity than other similar cables offered on the market. It is actually the best choice for GSM, UMTS and other wireless applications that demand very low insertion losses and the guarantee of a high longevity. Globally speaking, Insertion losses are typically of 30dB ; but we guarantee the lowest loss, meaning 23dB in GSM frequencies, when our connectors are used with both ends of feeder cables. Consequently, the mitigation measures are the best we can have on the market. The first part will provide you with a great view of our RF equipment (feeder cables, coaxial connectors, and jumpers) that we offer.

Références:

6

EQUIPMENT

TABLE OF CONTENTS
First Part : RF Equipment Pages 06/07

Hiflex Feeder cable 1/2” Page 08 Rigid Feeder Cable 1/2” Page 09 Feeder cable 7/8” Ultra-Low Losses Page 10 Feeder cable 1-1/4” Ultra-Low Losses Page 11 Feeder cable 1-5/8” Ultra-Low Losses Page 12 Coaxial Connectors Page 13 Références: Hiflex Jumpers Page 14 Rigid Jumpers Page 15

7

FEEDER CABLE 1/2’’ HIFLEX

Cable with standard UV resistant PE jacket, halogen free according to IEC 60754

SPECIFICATIONS
Design Inner conductor Material Diameter (mm) Dielectric Material Diameter (mm) Outer conductor Material Diameter (mm) Jacket Material Thickness (mm) Diameter (mm) copper clad aluminium wire 3.55 gas-injected cellular polyethylene 9.0 corrugated copper tube 12.2 black polyethylene 0.65 13.5

Electrical specification Characteristic impedance (Ω) Nominal capacity (pF/m) Relative propagation velocity (%) Inductance (μH/m) DC-resistance at 20°C inner conductor (Ω/km) outer conductor (Ω/km) RF peak voltage (kV) RF peak power (kW) Cut-off-frequency (GHz) Insulation resistance (MΩ.km) Attenuation [1] and power rating Frequency Attenuation at 20°C(*) (MHz) (dB/100m) 10 0.96 20 1.37 30 1.68 80 2.79 100 3.13 150 3.88 200 4.51 300 5.60 400 6.53 450 6.96 500 7.38 600 8.15 700 8.87 800 9.55 894 10.16 960 10.57 1000 10.82 1500 13.62 1700 14.63 1800 15.12 1880 15.51 2000 16.08 2170 16.86 2200 17.00 2300 17.45 2400 17.89 2500 18.33 3000 20.42 4000 24.29 6000 31.21

50 ±1 82 82 0.200 2.65 3.0 1.13 12.8 13.2 >>5000

Mechanical specifications Minimum bending radius single bending (cm) 15 repeated bends (cm) Maximum pulling strength (daN) Recommended temperature range Storage Installation Operation Maximum length per hoisting grip (m) Maximum hanger spacing Flat plate crush resistance (kg/mm) Bending moment (Nm) Weight (kg/km)

3 4 70 -70 to +85°C -40 to +60°C -55 to +85°C 70 0.5 1.7 2.7 200

(*) nominal values (**) Ambient temperature = 40°C; Temperature of inner conductor = 100°C;

Reference :
CFC 05019
1/2’’ hiflex

Mean power rating(**) (kW) 9.90 6.96 5.66 3.42 3.04 2.46 2.11 1.70 1.46 1.37 1.29 1.17 1.07 1.00 0.94 0.90 0.88 0.70 0.65 0.63 0.61 0.59 0.57 0.56 0.55 0.53 0.52 0.47 0.39 0.31

8

FEEDER CABLE 1/2’’ RIGID

Cable with standard UV resistant PE jacket, halogen free according to IEC 60754

Cable with UV resistant, halogen free, low smoke, flame retardant jacket according to IEC 60754-2, IEC 60332-12, IEC 60332-3 Cat. C and IEC 61034-1+2 Electrical specifications Characteristic impedance (Ω) Nominal capacity (pF/m) Relative propagation velocity (%) Inductance (μH/m) DC-resistance at 20°C inner conductor (Ω/km) outer conductor (Ω/km) RF peak voltage (kV) RF peak power (kW) Cut-off-frequency (GHz) Insulation resistance (MΩ.km) Attenuation [1] and power rating Frequency Attenuation at 20°C(*) (MHz) (dB/100m) 10 0.67 20 0.95 30 1.17 80 1.93 100 2.17 150 2.67 200 3.10 300 3.83 400 4.46 450 4.75 500 5.02 600 5.53 700 6.01 800 6.45 894 6.85 960 7.12 1000 7.28 1500 9.09 1700 9.74 1800 10.06 1880 10.30 2000 10.66 2170 11.16 2200 11.25 2300 11.53 2400 11.81 2500 12.09 3000 13.40 4000 15.81 6000 20.06 50 ±1 76 88 0.190 1.48 2.04 1.6 25.6 9.8 >>5000 Mean power rating(**) (kW) 11.74 8.27 6.73 4.08 3.64 2.95 2.54 2.06 1.77 1.66 1.57 1.43 1.31 1.22 1.15 1.11 1.08 0.87 0.81 0.78 0.77 0.74 0.71 0.70 0.68 0.67 0.65 0.59 0.50 0.39

SPECIFICATIONS
Design Inner conductor Material Diameter (mm) Dielectric Material Diameter (mm) Outer conductor Material Diameter (mm) Jacket Material Thickness (mm) Diameter (mm) copper clad aluminium wire 4.8 gas-injected cellular polyethylene 12.4 corrugated copper tube 13.7 black polyethylene 1.1 16.0

Mechanical specifications Minimum bending radius single bending (cm) 15 repeated bends (cm) Maximum pulling strength (daN) Recommended temperature range Storage Installation Operation Maximum length per hoisting grip (m) Maximum hanger spacing Flat plate crush resistance (kg/mm) Bending moment (Nm) Weight (kg/km)

7 12.5 100 -70 to +85°C -40 to +60°C -55 to +85°C 70 1 1.9 3.5 235

[1] a = 0.2105 b = 0.000625 x (ƒ) = a . √ f + b . f [dB/100m] (*) nominal values (**) Ambient temperature = 40°C; Temperature of inner conductor = 100°C; VSWR = 1.0; no solar loading

CFC 05004

Reference :
1/2’’ rigid

9

FEEDER CABLE 7/8’’

STANDARD Cable with standard UV resistant PE jacket, halogen free according to IEC 60754 SPECIFICATIONS Design Inner conductor Material Diameter (mm) Dielectric Material Diameter (mm) Outer conductor Material Diameter (mm) Jacket Material Thickness (mm) Diameter (mm)

smooth copper tube 9.3 gas-injected cellular polyethylene 23.5 corrugated copper tube 25.0 black polyethylene 1.4 28.0

Electrical specifications Characteristic impedance (Ω) Nominal capacity (pF/m) Relative propagation velocity (%) Inductance (μH/m) DC-resistance at 20°C inner conductor (Ω/km) outer conductor (Ω/km) RF peak voltage (kV) RF peak power (kW) Cut-off-frequency (GHz) Insulation resistance (M Ω.km) Attenuation [1] and power rating Frequency Attenuation at 20°C(*) (MHz) (dB/100m) 10 0.35 20 0.50 30 0.62 80 1.02 100 1.14 150 1.41 200 1.63 300 2.02 400 2.35 450 2.50 500 2.64 600 2.91 700 3.16 800 3.40 894 3.61 960 3.75 1000 3.83 1500 4.79 1700 5.13 1800 5.30 1880 5.43 2000 5.62 2170 5.88 2200 5.92 2300 6.07 2400 6.22 2500 6.37 3000 7.06 4000 8.33 6000 -

50 ±1 75 89 0.187 1.34 1.0 2.9 86 5.1 >>5000 Mean power rating(**) (kW) 25.46 17.93 14.60 8.85 7.89 6.40 5.51 4.46 3.83 3.60 3.41 3.09 2.85 2.65 2.49 2.40 2.35 1.88 1.75 1.70 1.66 1.60 1.53 1.52 1.48 1.45 1.41 1.27 1.08 -

Mechanical specifications Minimum bending radius single bending (cm) 15 repeated bends (cm) Maximum pulling strength (daN) Recommended temperature range Storage Installation Operation Maximum length per hoisting grip (m) Maximum hanger spacing Flat Plate Crush resistance (kg/mm) Bending moment (Nm) Weight (kg/km)

10 25 150 -70 to +85°C -40 to +60°C -55 to +85°C 70 1.2 1.4 Bending moment (Nm) 11.6 496

[1] a = 0.1107 b = 0.000333 x (ƒ) = a . √f + b . f [dB/100m] (*) nominal values (**) Ambient temperature = 40°C; Temperature of inner conductor = 100°C; VSWR = 1.0; no solar loading

Reference :
CFC 05041
Feeder cable 7/8’’

10

FEEDER CABLE 1- 1/4’’
STANDARD
Electrical specifications Cable with standard UV resistant PE jacket, halogen Characteristic impedance (Ω) free according to IEC 60754 Nominal capacity (pF/m)

50 ±1 76 88 0.190 1.8 0.5 4.25 180 3.3 >>5000

SPECIFICATIONS
Design Inner conductor Material Diameter (mm) Dielectric Material Diameter (mm) Outer conductor Material Diameter (mm) Jacket Material Thickness (mm) Diameter (mm) corrugated copper tube 13.6 gas-injected cellular polyethylene 33.5 corrugated copper tube 36.0 black polyethylene 1.5 39.0

Relative propagation velocity (%) Inductance (μH/m) DC-resistance at 20°C - inner conductor (Ω/km) - outer conductor (Ω/km) RF peak voltage (kV) RF peak power (kW) Cut-off-frequency (GHz) Insulation resistance (MΩ.km)
Attenuation [1] and power rating Frequency (MHz) 10 20 30 80 100 150 200 300 400 450 500 600 700 800 894 960 1000 1500 1700 1800 1880 2000 2170 2200 2300 2400 2500 3000 4000 6000 Attenuation at 20°C(*) (dB/100m) 0.27 0.38 0.47 0.79 0.89 1.10 1.28 1.59 1.86 1.99 2.11 2.33 2.55 2.74 2.92 3.05 3.12 3.94 4.25 4.39 4.51 4.68 4.91 4.95 5.09 5.22 5.35 5.98 -

Mean power rating(**) (kW) 39.73 27.90 22.66 13.62 12.12 9.78 8.39 6.74 5.76 5.40 5.09 4.60 4.22 3.91 3.67 3.53 3.44 2.72 2.53 2.44 2.38 2.30 2.19 2.17 2.11 2.06 2.01 1.79 -

Mechanical specifications Minimum bending radius single bending (cm) 15 repeated bends (cm) Maximum pulling strength (daN) Recommended temperature range - Storage - Installation - Operation Maximum length per hoisting grip (m) Maximum hanger spacing Flat plate crush resistance (kg/mm) Bending moment (Nm) Weight (kg/km)
[1] a = 0.084

20 30 200 -70 to +85°C -40 to +60°C -55 to +85°C 70 1.4 3.4 25 830

b = 0.000461 x(ƒ) = a . √ f + b . f [dB/100m] (*) nominal values (**) Ambient temperature = 40°C; Temperature of inner conductor = 100°C; VSWR = 1.0; no solar loading

Reference :
CFC 05040
Feeder cable 1- 1/4’’

11

FEEDER CABLE 1- 5/8’’ RIGID

STANDARD Cable with standard UV resistant PE jacket, halogen free according to IEC 60754

Cable with UV resistant, halogen free, low smoke, flame retardant jacket according to IEC 60754-2, IEC 603321-2, IEC 60332-3 Cat. C and IEC 61034-1+2 Electrical specifications Characteristic impedance (Ω) Nominal capacity (pF/m) Relative propagation velocity (%) Inductance (μH/m) DC-resistance at 20°C inner conductor (Ω/km) outer conductor (Ω/km) RF peak voltage (kV) RF peak power (kW) Cut-off-frequency (GHz) Insulation resistance (MΩ.km) Attenuation [1] and power rating Frequency Attenuation at 20°C(*) (MHz) (dB/100m) 10 0.20 20 0.28 30 0.34 80 0.57 100 0.65 150 0.80 200 0.93 300 1.16 400 1.36 450 1.46 500 1.54 600 1.71 700 1.87 800 2.01 894 2.14 960 2.23 1000 2.29 1500 2.90 1700 3.13 1800 3.23 1880 3.32 2000 3.45 2170 3.62 2200 3.65 2300 3.75 2400 3.85 2500 3.95 3000 4000 6000 -

SPECIFICATIONS
Design Inner conductor Material Diameter (mm) Dielectric Material Diameter (mm) Outer conductor Material Diameter (mm) Jacket Material black polyethylene Thickness (mm) Diameter (mm) corrugated copper tube 17.7 gas-injected cellular polyethylene 43.0 corrugated copper tube 46.6

50 ±1 75 89 0.190 1.37 0.39 5.5 302 2.7 >>5000 Mean power rating(**) (kW) 51.53 36.17 29.36 17.63 15.68 12.64 10.84 8.70 7.43 6.96 6.56 5.92 5.43 5.03 4.72 4.53 4.43 3.49 3.24 3.13 3.05 2.94 2.80 2.77 2.70 2.63 2.57 -

1.7 50.0

Mechanical specifications Minimum bending radius single bending (cm) 15 repeated bends (cm) Maximum pulling strength (daN) Recommended temperature range Storage Installation Operation Maximum length per hoisting grip (m) Maximum hanger spacing Flat plate crush resistance (kg/mm) Bending moment (Nm) Weight (kg/km)

20 40 250 -70 to +85°C -40 to +60°C -55 to +85°C 70 1.5 2.6 45 1130

[1] a = 0.061 b = 0.000359 x (ƒ) = a . √ f + b . f [dB/100m] (*) nominal values (**)Ambient temperature = 40°C; Temperature of inner conductor = 100°C; VSWR = 1.0; no solar loading

Reference :
CFC 05034
Feeder 1- 5/8’’

12

COAXIAL CONNECTORS

7/16 F DT 7/8’’ FEMALE STRAIGHT

7/16 F DT 1- 5/8’’ FEMALE STRAIGHT

7/16 F DT 1- 1/4’’ FEMALE STRAIGHT

7/16 M CDE ½’’ FLEXIBLE MALE RIGHT ANGLED HI-FLEX 1/2’’

CRA 05692 CRA 05982 CRA 05082 CRA 05706 CRA 05206 CRA 05216 CRA 05721 CRA 05720 CRA 05719 CRA 05725 CRA 05286 CRA 05287

References & Specifications

Coaxial Connector 7/16 MALE STRAIGHT 1/2’’ FLEXIBLE Coaxial Connector 7/16 MALE STRAIGHT 1/2’’ RIGID Coaxial Connector 7/16 FEMALE STRAIGHT 1/2’’ FLEXIBLE Coaxial Connector 7/16 FEMALE STRAIGHT 1/2’’ RIGID Coaxial Connector 7/16 MALE RIGHT- ANGLED 1/2’’ FLEXIBLE Coaxial Connector 7/16 MALE RIGHT- ANGLED 1/2’’ RIGID Coaxial Connector 7/16 FEMALE STRAIGHT Clip 7/8’’ RIGID Coaxial Connector 7/16 MALE STRAIGHT Clip 7/8’’ RIGID Coaxial Connector 7/16 FEMALE STRAIGHT 1-1/4’’ RIGID Coaxial Connector 7/16 MALE STRAIGHT 1- 1/4’’ RIGID Coaxial Connector 7/16 FEMALE STRAIGHT 1-5/8’’ RIGID Coaxial Connector 7/16 MALE STRAIGHT 1-5/8’’ RIGID

Références:

13

HIFLEX JUMPERS

Electrical Specifications of Terminated Standard Jumper Cables : 800-1000 MHz 1600-2000 MHz 1 Return loss (VSWR) (typically) -32 dB (1.05: 1) -30 dB (1.06:1) Return loss (VSWR) (Min) -28 dB (1.08:1) -26 dB (1.1:1) 11.2 dB (+0.03 dB for 17.0 dB (+0.03 dB for 2 Attenuation (per 100m) (Max) at 20°C connectors) connectors) 3 Power Handling (Min) continuous 750 W 500 W 4 Level of IMP (Intermodulation Products) 2 unmodulated test tones each at +43 dBm (20 W) 3nd or higher order IMP (typically) -118 dB (-161 dBc) -118 dBm (-161 dBc) (min) -107 dBm (-150 dBc) -107 dBm (-150 dBc) 5 Impedance 50 Ω (+- 1.5 Ω) 50 Ω (+- 1.5 Ω) 6 RF Voltage Rating (Peak) 1100 V 1100 V 7 Velocity of Propagation 82% 82% 8 Contact Potential (centre and outer conductors) no dissimilar metal interfaces Mechanical and Environmental specifications: 1 Temperature Range (Installation) -40°C…+60°C (Operating) -45°C…+85°C 2 Relative humidity 10%…100% 3 General Environmental Corrosion and UV resistant 4 Minimum Bending Radius 30mm 5 Connector Torque (nominal) 8 Nm (N types) 15 Nm (7/16 Types) 6 Packaging Orange protection caps for connectors (standard)

Design:

All metal contact parts from connectors are silver plated. Their design is optimized to provide an extra low level of intermodulation, excellent return loss values, and improved jumper cable performances. Excellent water tightness provided by the special connector design (O-ring in connector head). The over molding of the connector provides an additional mechanical stability. Easy, fast and reliable installation.

References :
Connector 7-16, 2 Male straight 961 005 0,5 m 961 010 1m 961 015 1,5 m 961 020 2m 961 025 2,5 m 961 030 3m 961 040 4m 961 050 5m

References :
961 505 961 510 961 515 961 520 961 525 961 530 961 540

Connector 7-16, 1 Male straight and 1 male right angle 90°
0,5 m 1m 1,5 m 2m 2,5 m 3m 4m 5m

961 550

14

RIGID JUMPERS

*-24 dB (1.12:1) for angle connectors

Electrical Specifications of Terminated Standard Jumper Cables : 800-1000 MHz 1600-2000 MHz 1 Return loss (VSWR) (typically) -38 dB (1.02: 1) -30 dB (1.06:1) Return loss (VSWR) (Min) -28 dB (1.08:1) -26 dB (1.10:1)* 7.2 dB (+0.03 dB for 11.5 dB (+0.03 dB for 2 Attenuation (per 100m) (Max) at 20°C connectors) connectors) 3 Power Handling (Min) continuous 1000 W 750 W 4 Level of IMP (Intermodulation Products) 2 unmodulated test tones each at +43 dBm (20 W) 3nd or higher order IMP (typically) -122 dB (-165 dBc) -122 dBm (-165 dBc) (min) -112 dBm (-155 dBc) -112 dBm (-155 dBc) 5 Impedance 50 Ω (+- 1 Ω) 50 Ω (+- 1 Ω) 6 RF Voltage Rating (Peak) 1100 V 1100 V 7 Velocity of Propagation 88% 88% 8 Contact Potential (centre and outer conductors) no dissimilar metal interfaces

Mechanical and Environmental specifications: 1 Temperature Range (Installation) -40°C…+60°C (Operating) -45°C…+85°C 2 Relative humidity 10%…100% 3 General Environmental Corrosion and UV resistant 4 Minimum Bending Radius 70 mm (single) 125 mm (repeat) 5 Connector Torque (nominal) 15 Nm -25 Nm 6 Packaging Orange protection caps for connectors (standard)

Design:

All metal contact parts from connectors are silver plated. Their design is optimized to provide an extra low level of intermodulation, excellent return loss values, and improved jumper cable performances. Excellent water tightness provided by the special connector design (O-ring in connector head). The over molding of the connector provides an additional mechanical stability. Easy, fast and reliable installation.

References :
962 005 962 010 962 015 962 020 962 025 962 030 962 040 962 050

Connector 7-16, 2 Male Straight
0,5 m 1 m 1,5 m 2m 2,5 m 3m 4m 5m

15

RF ACCESSORIES

Since the very beginning of the first base stations deployments almost 20 years ago, KATHREIN and its technical specialists have been developing solutions and accessories that can bring mobile operators and installation companies exactly what they need. There has been an increased development of products from high-performing technologies elaborated step by step, all over the past 20 years. Their easiness and their fast installation are highly appreciated by most of the biggest service providers and mobile operators all over the world. The following chapter is basically about all RF Accessories you need on a site, from accessories for Base Station Antennas, clamps for feeder cables, cable trays, to tools (stripping tools, wrench handles for connectors etc..). It will be a useful hand for technical engineers and specialists, and guarantee them a safe installation, while saving time.

16

RF ACCESSORIES

TABLE OF CONTENTS

Second Part : RF Accessories Hoisting Grips Stripping Tools Wrench Handles for Connectors Instructions to use Stripping Tools Protection of connections Weatherproofing Kit Snap-in Hangers for Feeder Cables from 1/2” to 5/8” Self-Locking Cable Clamps for 1, 2, 3, 4 and 6 Feeder Cables Cables Ties Wall Entries

Page 16/17 Page 18 Page 19 Page 20 Page 21 Page 22 Page 23 Page 24 Page 25 Page 26 Page 27

17

HOISTING GRIPS
Hoisting Grips are used to lift and hoist cables up to the top of the tower. Hoisting grips have an important tin content, and are bronze-coated to provide the highest resistance to corrosion. Use one hoisting grip every 60 meters.

Size Material Design Include Specificities

from 1/2’’ to 1-5/8” cable Tinned bronze Mesh grip with single eye support Grip, self-locking clip, tape pre-laced to make installation easier

References :
Available for 1/2’’, 7/8”, 1-5/8” and 1-1/4” feeder cables 950 010 950 011 950 013 950 012
Tool 1/2’’ Tool 7/8’’ Tool 1-1/4’’ Tool 1- 5/8’’

18

STRIPPING TOOLS

Tool 7/8’’

Tool 1- 5/8’’

Tool 1- 1/4’’

Tool 1/2’’ Hi-Flex

Tool 1/2’’ rigid

References :
960 085 960 084 960 086 960 064 960 123
Tool ½’’ Hi-Flex Tool ½’’ Rigid Tool 1- 5/8’’ Tool 7/8’’ Tool 1- 1/4’’

19

WRENCH HANDLE FOR CONNECTORS

Connector ½’’ rigid 7/8’’ 1- 1/4’’ 1- 5/8’’

Wrench size mm 19 30 44 58

Max. Wrench Head Thickness mm 7 12 N/A N/A

Back Nut Torque Nm 20 30 40 50

References :
During the connector tightening, Hold the connector body fixed with the help of the torque wrench.

950 002 950 003 950 001 950 004

Connector 1/2’’ Connector 7/8’’ Connector 1- 5/8’’ Connector 1- 1/4’’

20

INSTRUCTIONS TO USE STRIPPING TOOLS 7/8’’

21

GSCI closure system (Gel Seal for Coax Connectors) Feeders-Jumpers and Jumpers- Antennes
The GSIC closure system consists of in-line closures as well as closures used to seal Antenna/ Jumper, and Jumper/ Feeder. It is designed to provide water tightness, environmental and mechanical protection for coaxial connectors. By providing a longterm and effective protection against water infiltration and other pollutants (IP68 acc. EN 60529), the gel guarantees a reliable and cost-effective solution. The GSIC closure system consists of the following components : - A wraparound central body molded from a UV-stabilized polymer. - A closing channel which is also molded from a UV-stabilized polymer. Sealing components : - The sealing is performed by a gel under compression - All sealing elements are integrated into the product

PROTECTION OF CONNECTIONS

Reliable protection for temperature variation between -30°C and 60°C, without deterioration of subsequent product performance Protection against excessive cable bending No connector disunion Kits are easy and quick to install, at temperatures of between -10°C and +45°C Easily removable and re-usable No tape, mastics or tools required for installation and re-use UV resistant, and tested under extremely severe conditions, vibrations and temperature cycles (acc. ICE 60068-2-14 Test Nb).

References :
The reference CAC05347 can only be used with connectors DIN 7/16, maximum length 60mm, maximum diameter 27mm, lowest distance between panel and connector : 45mm

CAC 05347 CAC 05348 CAC 05350 CAC 05351

Antenna/ jumper Jumper/ feeder cable 7/8’’ Jumper/ feeder cable 1- 1/4’’ Jumper/ feeder cable 1- 5/8’’

22

WEATHERPROOFING KIT
Composition and technical specifications: Butyl Butyl tape (0.50m x 38mm)

Electrical tape Plastic electrical tape (10m x 15mm)

One kit guarantees the weatherproofing of: 2 connectors 7/8’’ or 1 connector 1- 1/4’’ ou 1- 5/8’’ Remove the protecting tape from the vulcanized rubber band (Butyl) Cover up all the connection, starting from the winding down below. Tighten steadily during the process. Continue the winding until you get 50 to 60 mm beyond the connector. Wind the plastic band in reverse of the Butyl winding. Cover up the Butyl with at least 3 layers of plastic band which must exceed an average of 25mm on both sides of the rubber band. Stretch steadily during the winding of the first two layers, but do not stretch the last one. Press slowly with hand on the winding to guarantee a safe adherence all around the connector.

Reference :
CAC 05346
Weatherproofing Kit

23

CLAMPS FOR 1/2’’ TO 1- 5/8’’ FEEDER CABLE
Clamps for feeder cables designed for towers of angle-board type

Specificities: Machining Components Tickness Assembling Mechanical resistance

Blanked and press-formed Fully tempered 301 stainless steel, hardened E4 0.8 to 1.5, according to the reference Stainless steel blind rivet Tear-off cable side > 12 Kgf Tear-off angle iron side > 25 Kgf Cable Slip > 6 Kgf

For cables with a diameter from 16 to 50 mm Mounting : 1 clip every meter at the lowest.

References :
960 063 960 053 960 088 960 087
Clamps for 1/2’’ feeder cables Clamps for 7/8’’ feeder cables Clamps for 1- 1/4’’ feeder cables Clamps for 1- 5/8’’ feeder cables

24

CLAMPS FOR 1 TO 6 FEEDERS CABLES
For flat and round with thickness between 3 and 12mm. Calibrated saddles

Material : AISI 304 Stainless Steel Glass reinforced fiber P.A, U.V resistant Color : black (grey on request)

References :
CAC 05300 : Clamp for 1 feeder cable 1/2” CAC 05301 : Clamp for 1 feeder cable 7/8” CAC 05113 : Clamp for 1 feeder cable 1-1/4” CAC 05110 : Clamp for 1 feeder cable 1-5/8”

References :
CAC 05121 : Clamp for 2 feeder cables 1/2” CAC 05302 : Clamp for 2 feeder cables 7/8” CAC 05109 : Clamp for 2 feeder cables 1-1/4” CAC 05303 : Clamp for 2 feeder cables 1-5/8

References :
CAC 05119 : Clamp for 3 feeder cables 1/2” CAC 05304 : Clamp for 3 feeder cables 7/8” CAC 05315 : Clamp for 3 feeder cables 1-1/4” CAC 05316 : Clamp for 3 feeder cables 1-5/8”

References :
CAC 05122 : Clamp for 4 feeder cables 1/2” CAC 05120 : Clamp for 4 feeder cables 7/8” CAC 05319 : Clamp for 4 feeder cables 1-1/4” CAC 05318 : Clamp for 4 feeder cables 1-5/8”

References :
CAC 05124 : Clamp for 6 feeder cables 1/2» CAC 05311 : Clamp for 6 feeder cables 7/8» CAC 05317 : Clamp for 6 feeder cables 1-1/4» CAC 05123 : Clamp for 6 feeder cables 1-5/8»

25

CABLE TIE

Technical specifications
Description Size Composition Color Conditioning Tightening Cable tie 9 x 357 mm Polyamide 12 black 100 pcs boxes Lowest diameter : 26 mm Biggest diameter : 92 mm

Reference :
CAC 05185
Cable tie

26

WALL ENTRIES
Ranges from 1 to 12 feeders

IP67 waterproof and fire resistant to REI 120 For a tight sealing of cables Easy and quick mounting Fixings accessories are included Elastic cushions on separate request Grounding bar on request

Description AISI 304 (V2A) steel plate Black EPDM gasket Elastic collar Removable plastic PIN AISI 304 Hose clamp for Collar (FAS) Sectorial cushions (GSR & GST) Round cushions (GR) Removable protective film Silicon lubricant (LUS) Grounding bar on request (BEI)

Reference :
CAC 05310
Wall entries
Module 6 x 2 feeder cables (7/8’’)

27

PROTECTION

The lightning current is basically about a short and intense electromagnetic field (of double exponential type) that can damage equipment put at each ends of feeder cables, or cause a bad functioning. Using components with new technologies of bad quality can easily increase the sensitivity of electrical and electronic equipment from lightning. Side protections limit troubles induced by the discharge current, to a tolerable level for materials located in the extremities. Lightning arrester, surge protector, isolation systems are all rarely used directly. They are more used as a whole system more or less complex and all put at the cable extremities, and close to the equipment that need to be protected. They also need to be close, as much as possible, to their inlet in buildings. These side protections can absolutely not damage the signal but indeed generate a safe flow path for the lightning current to the ground, to avoid damages on the cables. Thanks to the large choice of side protections on the market, every cable type can easily be mounted with the perfect protection. The protection depends on the signal spread by the cable (tension, current, frequency). In specific cases, the designer has between several circuit types that he can use, and can consequently choose the circuit with the very best specifications he needs to resolve his technical issues. This chapter will provide you with a complete range of products designed to protect your RF equipment against lightning, as well as weatherproofing solutions, for isolation matters.

28

OF RF EQUIPMENT

TABLE OF CONTENTS

Third Part : Protection of RF Equipment

Page 28/29

Copper Grounding Bar Universal Earthing Kit Earthing Kits for 1/2’’, 7/8”, 1-1/4” & 5/8” Feeder Cables Lightning Arrester for GSM 900, 1800, and UMTS Lightning Arrester : Installation Instructions Basic Information for a safe Cell Site Protection of equipment upper extremities Cell Sites suffering from Lightning : How to provide a safe flow path for the lightning current

Page 30 Page 31 Page 32 Page 33 Page 34 Page 35 Page 36

Page 37

29

GROUNDING BAR

Grounding bar : AISI 304 STAINLESS STEEL

Holes : 9 x M8

Reference :
960 054
Grounding bar

30

UNIVERSAL EARTHING KIT
For any type of feeder cable.

Reference :
921 060
Universal Earthing kit

Protection against lightning
31

Kit in detail: 1/ Contact bar of tin-plated copper 2/ Tin-plated copper mesh 3/ Connecting lug screw M8 4/ NAS self-agglomerating UV proof black color tape, for protection and sealing 5/ P.E. insulated copper cable, length = 50cm, fire resistant CEI 20-22, Color : black (green and yellow on request) 6/ Tinned copper lugs

EARTHING KIT FOR FEEDER CABLE 1/2’’, 7/8’’, 1- 1/4’’ & 1- 5/8’’

Technical specifications:
Compact structures Quick and easy installation Lightning tested (CESI) Low contact resistance < 1 mOhm Waterproof IP 67 (CESI) Corrosion resistant Environmental test (IEC 68-2-14) No extra taping needed

Remove the section of the sheath with a knife. Take care not to damage the outer copper conductor of the cable. Carefully lubricate the cable sheet with special silicon lubricant S. Open the KMT contact slip and place it on the outer copper conductor of the cable. Close the steel shell and tighten the locking screw. Take care to well fit the rubber gasket on the cable jacket. Fix the cable lug of the grounding wire to the ground of the tower with the M8 screw and nut.

References :
921 000 921 061 921 020 921 062
Feeder Cable ½’’ Feeder Cable 7/8’’ Feeder Cable 1- 5/8’’ Feeder Cable 1- 1/4’’

32

LIGHTNING ARRESTER FOR GSM 900, 1800, UMTS

Electrical specifications: Power flow ROS ROS ROS Losses insertion Connection Intermodulation Mecanical specifications: Length Diameter Weight IP IEC

100 KA en onde 8/20 µs (1 fois) 800 à 880 MHz < 1.08 880 à 2500 MHz < 1.08 2500 à 2600 MHz < 1.10 < 0.05 dB 7/16F (antenna side) 7/16M (BTS side) < 160 dBc

105 mm 45 mm 525 g 67 68 558521

Ground connection on screw M5 conductor 6 mm² minimum

Reference :
CRA 05255
lightning arrester

33

LIGHTNING ARRESTER : INSTRUCTIONS FOR INSTALLATION

To guarantee you the best protection you can find, the arrester has to be mounted as close as possible from the equipment that has to be protected (BTS…). This specific equipment needs to be mounted in a safe and well-covered place. For Outdoor protection, use weatherproofing kit

Références: Références:

34

BASIC INFORMATION FOR A SAFE SITE
Geographical area Keraunic level
The study of a lightning protection requires a study of the local geographical conditions, especially the exposure degree of the structure to : - the lightning risk, to assess the “potential for risk”, useful in the specification of protection devices, - the winds, studying the structures architecture to determine the best mechanical design of the device Knowing the exact geographical position of the site to protect is determining for the keraunic level. The keraunic level Nk indeed expresses the number of days per year where thunder is heard at a given place. This level indicates the degree of protection (site strongly or not strongly exposed) and make possible to calculate the lightning density Ng, which expresses the number of strikes per year per km².

Wind direction
Knowing the prevailing winds in thundery periods is less important than the keraunic level. But it can help to change the position of each protection. Indeed, every calculation on lightning rods consider clap of thunder as vertical. However, they are lightly deflected by aerological phenomenon.

Site geology
Two factors have to be considered on a geological level.

Ground resistance
It is a determining point to take decision regarding the ground plugs size, which provides a safe flow path for the lightning current.

Homogeneous Land surface
It is very important regarding the ground plug location; resistance between ground plugs will highly interfere with the differences of potential, included between buildings when lightning strikes.

Site environment : building and surroundings
Building sizes (length, height, and width), terrace plans, towers and shelters positioning, and basically all height measurements are necessary guidelines for the survey. The plan will have to include the indication of the north, the surrounding facilities (water supply, electric power station).

35

PROTECTION OF HEAD END EQUIPMENT
Phenomenon: Lightning currents cause a short and intense electromagnetic field which is double exponential, that can damage head-end equipment connected to cables. Using high tech components from bad quality can easily increase the severe impact of lightning on electrical and electronic equipment. Head-end equipment are involved to limit disturbances caused by lightning, until you get an acceptable level that head-end equipment can handle. Physical magnitude

Peak value for 1 lightning strike Time of climb Time Spectrum

35 KA 100 ns to 100 µs 10 µs to 100 ms 1 KHz to 1 MHz (Maximum weight about 100 KHz)

Main information on head-end equipment Lightning Arrester (association between spark gap and varistor)

Surge Suppressor (transient voltage suppression diode) Isolation systems (slightly capacitive transformers or lines connected for microwave links applications). Lightning arrester, surge protector, isolation systems are all rarely used directly. They are more used as a whole system more or less complex and all put at the cable extremities, and close to the equipment that need to be protected. They also need to be close, as much as possible, to their inlet in buildings. These side protections can absolutely not damage the signal but indeed generate a safe flow path for the lightning current to the ground, to avoid damages on the cables. Thanks to the large choice of side protections on the market, every cable type can easily be mounted with the perfect protection. The protection depends on the signal spread by the cable (tension, current, frequency). In specific cases, the designer has between several circuit types that he can use, and can consequently choose the circuit with the very best specifications he needs to resolve his technical issues.

36

CELL SITES SUFFERING FROM LIGHTNING
How to provide a safe flow path for the lightning current

Pylon Protection

Lateral Fixing Brackets

Lightning Rod (Basic Metal Rod)

Steel Strapping Tapes

Meplat 30x2mm

Earthing Kit

Oblong Test Clamp Copper Square Clamps

Inspection Hole

Meplat 30x2mm

Crow-foot earthing system

Connector

Copper Ground Rod

37

7, rue des Gardes F-91370 VERRIERES LE BUISSON France

KATHREIN France

Tél. +33 1 69 53 64 53 Fax +33 1 69 53 64 54 www.kathrein.fr [email protected]
En raison de l’évolution technique, KATHREIN se réserve le droit à tout moment et sans préavis de modifier les caractéristiques techniques annoncées pour ces produits et/ ou de cesser la fabrication de ceux-ci.