38QRR
Performancer Series Heat Pump
with PURONr Refrigerant
1---1/2 to 5 Nominal Tons
Product Data
INDUSTRY LEADING
FEATURES / BENEFITS
Energy Efficiency
S 13 -- 15.5 SEER/10.5 -- 13.5 EER/7.7 -- 9.0 HSPF
Sound
S Levels as low as 66 dBA
Design Features
S New aesthetics
S Small footprint
S WeatherArmort cabinet
⎯ All steel cabinet construction
⎯ Baked on powder paint
⎯ Mesh coil guard
the environmentally sound refrigerant
Carrier Heat Pumps with Puronr refrigerant provide a collection
of features unmatched by any other family of equipment. The
38QRR has been designed utilizing Carrier’s Puron refrigerant.
This environmentally sound refrigerant allows you to make a
responsible decision in the protection of the earth’s ozone layer.
As an Energy Starr Partner, Carrier Corporation has determined
that this product meets the Energy Starr guidelines for energy
efficiency. Refer to the combination ratings in the Product Data
for system combinations that meet Energy Starr guidelines.
Reliability, Quality and Toughness
S Scroll compressor
S Factory--supplied filter drier
S High pressure switch
S Low pressure switch
S Accumulator
S Line lengths up to 250’
S Low ambient operation (down to --20_F/--28.9_C))
(with low ambient accessories)
Limited Warranty
S Residential:
5--years on all parts/10--years on compressor.
S
Commercial and 3--Phase:
1--year on all parts/5--years on compressor.
MODEL NUMBER NOMENCLATURE
8
9
10
11
12
13
N
N
A/N
A/N
A/N
N
N
1
8
A
0
0
3
0
Variations
Open
Open
Voltage
Minor
Series
1
2
3
4
5
6
7
N
N
A
A
A/N
N
3
8
Q
R
R
0
Product
Series
QRR = Horizontal Discharge
Heat Pump
Cooling Capacity
38=AC/HP
A=Standard
0=Not 0=Not
Defined Defined
3=208/230 ---1
5=208/230 ---3
6=460/3
0, 1, 2...
ISO 9001:2000
38QRR
REGISTERED
the environmentally sound refrigerant
This product has been designed and manufactured to
meet Energy Star® criteria for energy efficiency when
matched with appropriate coil components. However,
proper refrigerant charge and proper air flow are critical
to achieve rated capacity and efficiency. Installation of
this product should follow all manufacturing refrigerant
charging and air flow instructions. Failure to confirm
proper charge and air flow may reduce energy
efficiency and shorten equipment life.
PHYSICAL DATA
UNIT 38QRR
NOMINAL CAPACITY Tons (kg)
OPERATING WEIGHT lb (kg)
REFRIGERANT TYPE
METERING DEVICE
CHARGE (lb)* (kg)
COMPRESSOR
Type
Oil Charge (POE --- oz)
Crankcase Heater (watts)
OUTDOOR FAN
Rpm/Cfm
Diameter (in.)
No. Blades
Motor (hp)
OUTDOOR COIL
Face Area (sq ft)
No. Rows
FPI
HIGH PRESSURE SWITCH
Cut --- In (psig) Cutout (psig)
LOW PRESSURE SWITCH
Low Cutout (psig)
Low Cut --- in (psig)
REFRIGERANT LINES
Connection Type
Liquid Line (in.) OD
Vapor Line (in.) OD
Max Length (ft)
Max Lift (ft)
Max Drop (ft)
CONTROLS
Fusible Plug (F)
Control Voltage}
System Voltage
FINISH
210
24 vac
208/230 v
208/230 v, Single and 3 Phase, 460 v, 3 Phase
Gray
208/230 v
* Unit shipped with full factory charge. See ARI (Air Conditioning and Refrigeration Institute) capacity table for proper charge and piston for each fan coil type.
{ Valve connection size is 7/8 inch. Recommended line size is 1 ---1/8 inches.
} 24 v and a minimum of 40 va is provided in the fan coil unit.
FPI --- Fins Per Inch
POE --- Polyol Ester
2
VAPOR LINE SIZING AND COOLING CAPACITY LOSS
PURON 1--STAGE HEAT PUMP APPLICATIONS
LONG LINE APPLICATION: An application is considered
”Long line” when the total equivalent tubing length exceeds 80
ft. (24.38 m) or when there is more than 20 ft. (6.09 m) vertical
separation between indoor and outdoor units. These applications
require additional accessories and system modifications for
reliable system operation. The maximum allowable total
equivalent length is 250 ft. (76.2 m). The maximum vertical
Standard Application
25
(7.62)
50
(15.24)
80
(24.38)
Cooling Capacity Loss (%)
Total Equivalent Line Length ft. (m)
Long Line Application Requires Accessories
80+
100
125
150
175
200
225
(24.38
(30.48) (38.10) (45.72) (53.34) (60.96) (68.58)
+)
250
(76.2)
18,000
1--- Stage Puron
HP
24,000
1--- Stage Puron
HP
1/2
1
2
3
3
4
6
7
8
9
10
12
5/8
0
0
1
1
1
1
2
2
3
3
3
5/8
0
1
1
1
2
3
3
4
4
5
6
3/4
0
0
0
0
0
1
1
1
1
1
2
30,000
1--- Stage Puron
HP
5/8
3/4
7/8
5/8
3/4
7/8
1
0
0
1
0
0
2
0
0
2
0
0
3
1
0
4
1
0
3
1
0
4
1
0
3
1
0
5
1
0
4
1
1
6
2
1
5
2
1
7
2
1
6
2
1
9
3
1
7
2
1
10
3
1
8
3
1
11
4
2
9
3
1
13
4
2
3/4
0
1
2
2
2
3
4
4
5
6
6
7/8
0
0
1
1
1
1
2
2
2
3
3
3/4
0
1
2
2
3
4
5
5
6
7
8
7/8
0
0
1
1
1
2
2
2
3
3
4
3/4
7/8
1--- 1/8
1
0
0
2
1
0
4
2
0
4
2
0
5
2
1
6
3
1
7
4
1
9
4
1
10
5
1
11
5
1
12
6
2
36,000
1--- Stage Puron
HP
42,000
1--- Stage Puron
HP
48,000
1--- Stage Puron
HP
60,000
1--- Stage Puron
HP
Standard Length = 80 ft. (24.38 m) or less total equivalent length
Applications in this area are long line. Accessories are required as shown recommended on Long Line Application Guidelines
Applications in this area may have height restrictions that limit allowable total equivalent length, when outdoor unit is below indoor unit
See Long Line Application Guidelines
3
38QRR
Acceptable Vapor Line
Unit Nominal Size
Diameters
(Btuh)
(In. OD)
separation is 200 ft. (60.96 m) when outdoor unit is above indoor
unit, and 80 ft. (24.38 m) when the outdoor unit is below the
indoor unit. Refer to Accessory Usage Guideline below for
required accessories. See Longline Application Guideline for
required piping and system modifications. Also, refer to the table
below for the acceptable vapor tube diameters based on the total
length to minimize the cooling capacity loss.
ACCESSORIES
KIT NUMBER
KIT NAME
018
024
KAACH1401AAA
Crankcase Heater
X
X
KAAFT0101AAA
Evaporator Freeze Stat
X
KAATD0101TDR
Time Delay Relay
Winter Start Kit
(for low ambient)
DESCRIPTION
Thermidistatt Control — Non--- Programmable/Programmable Thermostat with
Humidity Control (For use in Dual Fuel, AC, HP, and 2S applications. Includes Outdoor Air Temperature Sensor.)
TSTATXXSEN01---B**
HybridHeatt (Dual Fuel) Thermostat — Auto Changeover, 7--- Day Programmable,
°F/°C, Includes Outdoor Sensor (TSTATXXSEN01--- B)
Thermostat — Auto Changeover, 7--- Day Programmable, °F/°C, 2--- Stage Heat,
1--- Stage Cool
Thermostat — Auto Changeover, Non--- Programmable, °F/°C, 2--- Stage Heat,
1--- Stage Cool
Standard Programmable Thermostat—Manual Changeover, 5--- 2 Day Programmable, °F/°C, 1--- Stage Heat/ 1--- Stage Cool
Builder’s Thermostat — Heat Pump, Non--- Programmable, °F/°C, 2--- Stage Heat,
1--- Stage Cool, Manual Changeover
Outdoor Air Temperature Sensor
TSTATXXNBP01
Backplate for Non--- Programmable Thermostat
TSTATXXPBP01
Backplate for Programmable Thermostat and Thermidistatt Control
TSTATXXSBP01
Backplate for Standard Programmable Thermostat
TSTATXXBBP01
Backplate for Builder’s Thermostat
TSTATXXCNV10{
Thermostat Conversion Kit (4 to 5 Wire) — 10 Pack
TP---PRH ---01 / TP---NRH ---01
Performance Series Programmable / Non--- programmable Thermidistat
TP---PHP---01 / TP---NHP---01
Performance Series Programmable / Non--- programmable HP Stat
TP---PAC ---01 / TP---NAC ---01
Performance Series Programmable / Non--- programmable AC Stat
TC ---PHP---01 / TC ---NHP---01
Comfort Series Programmable / Non--- programmable HP Stat
TC ---PAC ---01 / TC ---NAC ---01
Comfort Series Programmable / Non--- programmable AC Stat
* Do not use in zoning heat pump applications.
** Outdoor temperature sensor is an accessory for all Carrier electronic thermostats, except the non ---programmable air conditioner version and builder;s
thermostats. It allows the temperature at a remote location (outdoors) to be displayed on the thermostat. The outdoor air temperature sensor must be used
with the HybridHeatt (dual fuel) thermostat.
{ Thermostat conversion kit is a 24 ---vac accessory that can turn a 4 ---wire thermostat application into a 5 ---wire application. This kit can also be used to
replace a broken thermostat wire, or add an extra wire when needed.
The outdoor air temperature sensor is included with the Thermidistat Control and HybridHeatt (dual fuel) thermostat.
INFINITYt* CONTROLS
SYSTXCCUID01---A
SYSTXCCUIZ01---A
SYSTXCC4ZC01
SYSTXCCSMS01
SYSTXCCRRS01
SYSTXCCSAM01
SYSTXCCNIM01
SYSTXXXBPU01
* When applied with
DESCRIPTION
Infinity Control Deluxe 7--- Day Programmable (Wall--- mounted system control.)
Infinity Control Deluxe Zoning 7--- Day Programmable (Wall--- mounted control for a multi--- zone system.)
Infinity 4--- Zone Damper Control Module (Wall--- mounted control for a 4--- zone system.)
Infinity Smart Sensor (Optional wall control used to monitor temperature and/or fan control in an individual
zone.)
Infinity Remote Room Sensor (Monitors temperature in an individual zone.)
Infinity System Access Module (Hardware for wireless access and control via phone or internet.)
Infinity Network Interface Module (Connects Heat Recovery and Energy Recovery Ventilators or older
two--- speed outdoor models to system.)
Decorative Back Plate for Infinity Control (Decorative wall plate.)
Carrier’s IdealHumidityt series variable speed Indoor Models.
4
ACCESSORY USAGE GUIDELINE
ACCESSORY
Accumulator
Ball Bearing Fan Motor
Compressor Start Assist
Capacitor and Relay
Crankcase Heater
Evaporator Freeze Thermostat
Isolation Relay
Liquid Line Solenoid Valve
Master® Control
Motor
or Low---ambient Pressure Switch
Support Feet
REQUIRED FOR
LOW---AMBIENT COOLING
APPLICATIONS
(Below 55°F/12.8_C)
No
Yes{
REQUIRED FOR LONG
LINE
APPLICATIONS*
(Over 80 ft./24.38 m)
No
No
REQUIRED FOR
SEA COAST
APPLICATIONS
(Within 2 miles/3.22 km)
No
No
Yes{
Yes
No
Yes{
Yes{
Yes{
Yes
No
No
See Long Line Application
Guideline
No
No
No
Yes{
No
No
Recommended
No
Recommended
No
No
Accessory Description and Usage (Listed Alphabetically)
6. Evaporator Freeze Thermostat
An SPST temperature--actuated switch that stops unit operation
when evaporator reaches freeze--up conditions.
Usage Guideline:
Required when low ambient kit has been added.
7. Isolation Relay
An SPDT relay which switches the low--ambient controller out of
the outdoor fan motor circuit when the heat pump switches to
heating mode.
Usage Guideline:
Required in all heat pumps where low ambient kit has
been added.
8. Liquid--Line Solenoid Valve (LLS)
An electrically operated shutoff valve which stops and starts
refrigerant liquid flow in response to compressor operation. It is
to be installed at the outdoor unit to control refrigerant off cycle
migration in the heating mode.
Usage Guideline:
An LLS is required in all long line heat pump
applications to control refrigerant off cycle migration in
the heating mode. See Long Line Guideline.
9. Low--Ambient Pressure Switch Kit
A long life pressure switch which is mounted to outdoor unit
service valve. It is designed to cycle the outdoor fan motor in
order to maintain head pressure within normal operating limits
(approximately 100 psig/689.5 KpA to 225 psig/1551.3 KpA.
The control will maintain working head pressure at low--ambient
temperatures down to 0_F when properly installed.
Usage Guideline:
A Low--Ambient Pressure Switch or MotorMasterr
Low--Ambient Controller must be used when cooling
operation is used at outdoor temperatures below 55_F
(12.8_C).
10. MotorMasterr Low--Ambient Controller
A fan--speed control device activated by a temperature sensor,
designed to control condenser fan motor speed in response to the
saturated, condensing temperature during operation in cooling
mode only. For outdoor temperatures down to --20_F (--28.9_C),
it maintains condensing temperature at 100_F ±10_F (37.8_C ±
--12_C).
Usage Guideline:
A MotorMasterr Low Ambient Controller or
Low--Ambient Pressure Switch must be used when
cooling operation is used at outdoor temperatures
below 55_F (12.8_C).
Suggested for all commercial applications.
1. Ball--Bearing Fan Motor
A fan motor with ball bearings which permits speed reduction
while maintaining bearing lubrication.
Usage Guideline:
Required on all units when MotorMasterr is used.
2. Compressor Start Assist -- Capacitor and Relay
Start capacitor and relay gives a ”hard” boost to compressor
motor at each start up.
Usage Guideline:
Required for reciprocating compressors in the
following applications:
Long line
Low ambient cooling
Hard shut off expansion valve on indoor coil
Liquid line solenoid on indoor coil
Required for single--phase scroll compressors in the
following applications:
Long line
Low ambient cooling
Suggested for all compressors in areas with a history of
low voltage problems.
3. Compressor Start Assist — PTC Type
Solid state electrical device which gives a ”soft” boost to the
compressor at each start--up.
Usage Guideline:
Suggested in installations with marginal power supply.
4. Crankcase Heater
An electric resistance heater which mounts to the base of the
compressor to keep the lubricant warm during off cycles.
Improves compressor lubrication on restart and minimizes the
chance of liquid slugging.
Usage Guideline:
Required in low ambient cooling applications.
Required in long line applications.
Suggested in all commercial applications.
5. Cycle Protector
The cycle protector is designed to prevent compressor short
cycling. This control provides an approximate 5--minute delay
after power to the compressor has been interrupted for any
reason, including power outage, protector control trip, thermostat
jiggling, or normal cycling.
5
38QRR
* For tubing line sets between 80 and 200 ft. (24.38 and 60.96 m) and/or 20 ft. (6.09 m) vertical differential, refer to Residential Split---System Longline
Application Guideline.
{ Required for Low---Ambient Controller (full modulation feature) MotorMasterr Control.
38QRR
Accessory Description and Usage (Listed Alphabetically) -- CONTINUED
11. Outdoor Air Temperature Sensor
Designed for use with Carrier Thermostats listed in this
publication. This device enables the thermostat to display the
outdoor temperature. This device also is required to enable
special thermostat features such as auxiliary heat lock out.
Usage Guideline:
Suggested for all Carrier thermostats listed in this
publication.
12. Outdoor Thermostat
An SPDT temperature--actuated switch which turns on
supplemental electric heaters when outdoor air temperature drops
below a user--selected set point.
Usage Guideline:
Electric supplemental heat applications in non--variable
speed indoor units when electric heat staging is desired.
Usage Guideline:
Some local codes may require limiting the heating head
pressure in the vapor line in some applications.
13. Secondary Outdoor Thermostat
An SPDT temperature--actuated switch which turns on
third--stage of supplemental electric heaters when outdoor air
temperature drops below the second--stage set point.
Usage Guideline:
Outdoor thermostat applications where electric heater is
capable of 3--stage operation.
14. Sound Hood
Wraparound sound reducing cover for the compressor. Reduces
the sound level up to 2 dBA.
Usage Guideline:
Suggested when unit is installed closer than 15 ft
(4.57 m) to quiet areas, bedrooms, etc.
Suggested when unit is installed between two houses
less than 10 ft (3.05 m) apart.
15. Thermostatic Expansion Valve (TXV) Bi--Flow
A modulating flow--control valve which meters refrigerant liquid
flow rate into the evaporator in response to the superheat of the
refrigerant gas leaving the evaporator.
Usage Guideline:
Required in all heat pump applications
16. Time--Delay Relay
An SPST delay relay which briefly continues operation of indoor
blower motor to provide additional cooling after the compressor
cycles off.
Note: Most indoor unit controls include this feature. For those
that do not, use the guideline below.
Usage Guideline:
Accessory required to meet ARI rating, where indoor
not equipped.
FLA
--- Full Load Amps
HACR --- Heating, Air Conditininng, Refrigeration
LRA
--- Locked Rotor Amps
NEC
--- National Electrical Code
RLA
--- Rated Load Amps (compressor)
* Permissible limits of the voltage range at which the unit will operate satisfactorily
NOTE: Control circuit is 24 ---V on all units and requires external power source. Copper wire must be used from service disconnect to unit.
All motors/compressors contain internal overload protection.
SOUND POWER
Unit Size
018
024
030
036
048
060
Standard
Rating
(dBA)
69
66
71
72
71
72
Typical Octave Band Spectrum (dB, without tone adjustment)
125
NOTE: Dimensions shown in feet-inches. Dimensions in ( ) are millimeters.
0
CHASSIS
SIZE
(Reference)
018
38QRR
Unit Size
UNIT MODELS
1 -67/16
(468.3)
1 -67/16
(468.3)
1 -4
(406.4)
1 -4
(406.4)
D
2 -61/2
(774.7)
2 -61/2
(774.7)
1 -117/16
(595.3)
1 -117/16
(595.3)
E
1 -75/8
(498.5)
1 -75/8
(498.5)
1 -53/16
(436.6)
1 -53/16
(436.6)
F
2 -53/16
(741)
2 -113/16
(893.4)
1 -111/8
(587.4)
1 -51/8
(435)
G
1 -111/16
(347.7)
1 -21/2
(354.2)
1 -2
(355.6)
1 -1
(330.2)
J
0 -81/8
(206.4)
0 -81/2
(215.9)
0 -63/4
(171.5)
0 -65/8
(168.3)
K
1 -37/8
(403.2)
1 -67/8
(479.4)
0 -115/8
(295.3)
0 -111/4
(285.8)
L
(FIELD PROVIDED AND INSTALLED)
2 -101/16
(865.5)
3 -41/16
(1017.9)
2 -4
(711.5)
1 -10
(559.1)
H
0 -37/16
(88)
0 -37/16
(88)
0 -215/16
(75)
0 -215/16
(75)
N
8
7/
22.22
22.22
19.05
19.05
15.88
(mm)
15.88
M
306
278
232
187
176
609.6 x 1270
2 -0 x 4 -2
CHASSIS SIZES 0 & .6
CHASSIS SIZES 1 & 1.6
138.8
126.1
105.2
84.8
79.8
OPERATING WT
lb
(kg)
166
75.3
MINIMUM MOUNTING PAD
DIMENSIONS
8
7/
060
4
3/
036
048
4
8
3/
030
5/
5/8
in.
Support Feet
ft-in.
mm
1 -11 x 3 -6
584.2 x 1066.8
UNIT SIZE
38QRR
HEAT
PUMPS
024
018
UNIT SIZE
3. Center of Gravity
.
NOTES:
1. Required clearances: with coil facing wall, allow 6 in. minimum clearance
on coil side and coil end, and 3 feet minimum clearance on compressor
end and fan side. With fan facing wall, allow 8 in. minimum clearance on
fan side and coil end, and 3 feet minimum clearance on compressor end
and coil side. With multi-unit application, arrange units so discharge of one
does not enter inlet of another.
2. Dimensions in parenthesis are in millimeters.
0 -61/2
(165.4)
0 -61/2
(165.4)
0 -6
(152.4)
0 -6
(152.4)
P
38QRR
DIMENSIONS
8
COMBINATION RATINGS
018
024
Indoor Model
Cooling
Capacity
Cooling
Factory
Enhance
Standard
Rating
SEER
TDR
EER
ARI Standard Ratings
Heating
High Temp
Low Temp
E
COP
3.60
3.80
3.80
3.72
* Tested combination
{ In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use
either the accessory Time---Delay Relay KAATD0101TDR or a furnace equipped with TDR. Most Carrier furnaces are equipped with TDR.
EER — Energy Efficiency Ratio
SEER — Seasonal Energy Efficiency Ratio
TDR — Time---Delay Relay
TXV — Thermostatic Expansion Valve
NOTES:
1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included.
2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other
combinations are determined under DOE computer simulation procedures.
3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature.
4. Do not apply with capillary tube coils as performance and reliability are significantly affected.
15
38QRR
Unit
Size --Series
16
BUILDING HEAT LOSS, UNIT INTEGRATED
HEATING CAPACITY, MBTUH
0.00
--10
0
10
20
30
40
50
OUTDOOR TEMPERATURE, ºF
60
70
80
BASED ON INDOOR ENT. AIR
AT 70 ºF AND AT RATED CFM
0.0
2.9
10.00
8.8
11.7
5.9
38QRR018
FX4CNF018
38QRR024
FY4ANF030
38QRR030
FY4ANF030
20.00
30.00
40.00
14.6
38QRR036
FY4ANF036
50.00
20.5
17.6
38QRR048
FY4ANF048
38QRR060
FY4ANB060
23.4
60.00
70.00
80.00
38QRR BALANCE POINT WORKSHEET
38QRR
kW
17
1.01
1.00
1.01
1.01
1.01
1.01
1.01
1.01
1.01
1.01
1.01
1.01
1.01
1.01
1.01
1.01
CNPH*2417A**
CNPV*1814A**
CNPV*2414A**
CSPH*2412A**
CAP**2417A**
CNPH*2417A**
CNPV*2417A**
CSPH*2412A**
CNPH*2417A**
CSPH*2412A**
CAP**2417A**
CNPH*2417A**
CNPV*2417A**
CSPH*2412A**
CNPH*2417A**
CSPH*2412A**
See notes on pg. 20
1.01
CAP**2414A**
0.93
0.97
0.93
0.97
0.97
0.97
0.93
0.97
0.93
0.97
0.97
0.97
0.97
0.97
0.96
0.97
0.97
0.96
0.91
0.94
0.94
0.94
1.00
1.24
CAP**1814A**
11.55
1.27
0.96
22.58
72
14.63
1.28
40QAQ024
20.55
67
18.64
1.28
1.02
18.82
62
18.75
1.23
FX4CNF024
18.75
57
11.07
1.25
1.02
22.25
72
13.84
1.27
1.02
20.24
67
16.55
1.27
FV4BNF002
18.44
62
18.14
1.21
FE4ANF002
18.14
57
10.56
1.23
1.00
21.81
72
13.02
1.25
Power
19.83
67
15.46
1.26
1.00
18.03
62
17.41
Sens‡
Total
System
KW**
Capacity
17.41
Total
57
EWB
Capacity MBtuh†
75 (23.9)
Cooling
Indoor Model
*FX4CNF018
675
600
525
CFM
Evaporator Air
11.12
14.18
17.90
17.90
10.64
13.40
16.06
17.33
10.15
12.59
15.01
16.66
Sens‡
58MVB080 ---14
58MVB080 ---14
58MVB060 ---14
58MVB060 ---14
58MVB060 ---14
58MVB060 ---14
58MVB040 ---14
58MVB040 ---14
58CV(A,X)090 ---16
58CV(A,X)090 ---16
58CV(A,X)090 ---16
58CV(A,X)090 ---16
58CV(A,X)070 ---12
58CV(A,X)070 ---12
58CV(A,X)070 ---12
58CV(A,X)070 ---12
58CV(A,X)070 ---12
58CV(A,X)070 ---12
Furnace Model
21.34
19.41
17.90
17.90
21.05
19.14
17.47
17.33
20.67
18.78
17.08
16.66
Total
Capacity MBtuh†
85 (29.4)
DETAILED COOLING CAPACITIES
1.43
1.45
1.46
1.46
1.41
1.43
1.45
1.45
1.40
1.42
1.43
1.44
Total
System
KW**
20.05
18.23
17.01
17.01
19.80
18.00
16.50
16.49
19.47
17.69
16.10
15.87
10.67
13.73
17.01
17.01
10.20
12.96
16.50
16.49
9.71
12.16
14.55
15.87
1.63
1.65
1.67
1.67
1.62
1.64
1.65
1.65
1.60
1.62
1.64
1.64
18.71
17.01
16.07
16.07
18.50
16.82
15.60
15.60
18.22
16.55
15.10
15.04
10.21
13.25
16.07
16.07
9.75
12.50
15.60
15.60
9.27
11.71
14.04
15.04
38QRR018 Outdoor Section With FX4CNF018 Indoor Section
115 (46.1)
17.30
15.74
15.07
15.07
17.13
15.57
14.66
14.66
16.90
15.35
14.15
14.15
Total
9.74
12.76
15.07
15.07
9.28
12.02
14.66
14.66
8.81
11.24
14.15
14.15
Sens‡
Capacity MBtuh†
38QRR
1.86
1.88
1.89
1.89
1.84
1.86
1.87
1.87
1.82
1.84
1.86
1.86
CONDENSER ENTERING AIR TEMPERATURES _F (_C)
95 (35)
105 (40.6)
Total
Total
Capacity MBtuh†
Capacity MBtuh†
System
System
Total
Sens‡
Total
Sens‡
KW**
KW**
38QRR024 Outdoor Section With FY4ANF024 Indoor Section
2.50
2.50
2.50
2.50
2.46
2.46
2.46
2.46
2.42
2.43
2.43
2.43
CONDENSER ENTERING AIR TEMPERATURES _F (_C)
95 (35)
105 (40.6)
Total
Total
Capacity MBtuh†
Capacity MBtuh†
System
System
Total
Sens‡
Total
Sens‡
KW**
KW**
CONDENSER ENTERING AIR TEMPERATURES _F (_C)
95 (35)
105 (40.6)
Total
Total
Capacity MBtuh†
Capacity MBtuh†
System
System
Total
Sens‡
Total
Sens‡
KW**
KW**
CONDENSER ENTERING AIR TEMPERATURES _F (_C)
95 (35)
105 (40.6)
Total
Total
Capacity MBtuh†
Capacity MBtuh†
System
System
Total
Sens‡
Total
Sens‡
KW**
KW**
38QRR036 Outdoor Section With FY4ANF036 Indoor Section
CONDENSER ENTERING AIR TEMPERATURES _F (_C)
95 (35)
105 (40.6)
Total
Total
Capacity MBtuh†
Capacity MBtuh†
System
System
Total
Sens‡
Total
Sens‡
KW**
KW**
38QRR060 Outdoor Section With FY4ANF060 Indoor Section
5.75
5.73
5.72
5.72
5.63
5.61
5.60
5.60
5.52
5.50
5.48
5.48
CONDENSER ENTERING AIR TEMPERATURES _F (_C)
95 (35)
105 (40.6)
Total
Total
Capacity MBtuh†
Capacity MBtuh†
System
System
Total
Sens‡
Total
Sens‡
KW**
KW**
115 (46.1)
52.11
48.21
46.76
46.77
52.03
48.03
45.87
45.87
51.73
47.71
44.70
44.70
Total
30.08
40.58
46.76
46.77
28.80
38.33
45.87
45.87
27.44
35.94
44.70
44.70
Sens‡
Capacity MBtuh†
6.31
6.30
6.30
6.30
6.20
6.19
6.18
6.18
6.09
6.07
6.06
6.06
Total
System
KW**
125 (51.7)
46.77
43.52
42.85
42.85
46.83
43.46
42.20
42.20
46.71
43.29
41.27
41.27
Total
28.31
38.70
42.85
42.85
27.04
36.54
42.19
42.20
25.71
34.22
41.27
41.27
Sens‡
Capacity MBtuh†
6.92
6.92
6.92
6.92
6.81
6.81
6.81
6.81
6.70
6.69
6.69
6.69
Total
System
KW**
* Tested combination.
{ Total and sensible capacities are net capacities. Blower motor heat has been subtracted.
} Sensible capacities shown are based on 80_F (27_C) entering air at the indoor coil. For sensible capacities at other than 80_F (27_C), deduct 835 Btuh
(245 kW) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80_F (27_C), or add 835 Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air per degree above 80_F (27_C).
** System kw is total of indoor and outdoor unit kilowatts.
EWB — Entering Wet Bulb
NOTES:
1. Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per ARI standard 210/240 ---94. If additional tubing length and/or indoor unit is located above outdoor unit, a slight variation in
capacity may occur.
2. When the required data falls between the published data, interpolation may be performed. Extrapolation is not an acceptable practice.
38QRR018 Outdoor Section With FX4CNF018 Indoor Section
Total
Sys.
KW†
47 (8.3)
17.86
17.65
17.39
18.19
18.00
17.74
18.56
18.35
18.09
Integ*
38QRR
17.86
17.65
17.39
18.19
18.00
17.74
18.56
18.35
18.09
Total
Capacity MBtuh
1.52
1.54
1.57
1.45
1.46
1.49
1.38
1.39
1.42
Total
Sys.
KW†
57 (13.9)
21.06
20.85
20.54
21.41
21.23
20.95
21.73
21.60
21.35
Total
21.06
20.85
20.54
21.41
21.23
20.95
21.73
21.60
21.35
Integ*
Capacity MBtuh
1.61
1.65
1.68
1.52
1.55
1.60
1.45
1.47
1.52
Total
Sys.
KW†
67 (19.4)
24.58
24.44
24.18
24.89
24.80
24.58
25.15
25.12
24.96
Total
24.58
24.44
24.18
24.89
24.80
24.58
25.15
25.12
24.96
Integ*
Capacity MBtuh
1.71
1.74
1.79
1.63
1.65
1.70
1.55
1.57
1.61
Total
Sys.
KW†
24
0.98
0.98
0.98
0.98
0.98
0.99
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.99
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
FE4AN(B,F)003
FE4ANF002
FV4BN(B,F)003
FV4BNF002
FX4CNF024
FX4CNF030
CAP**2417A**
CAP**3014A**
CAP**3017A**
CNPH*3017A**
CNPV*3014A**
CNPV*3017A**
CSPH*2412A**
CSPH*3012A**
40QAQ024
CAP**2414A**
CAP**2417A**
CAP**3014A**
CAP**3017A**
CNPH*2417A**
CNPH*3017A**
CNPV*2414A**
CNPV*2417A**
CNPV*3014A**
CNPV*3017A**
CSPH*2412A**
CSPH*3012A**
CAP**2417A**
CAP**3017A**
CNPH*2417A**
CNPH*3017A**
CNPV*2417A**
CNPV*3017A**
CSPH*2412A**
CSPH*3012A**
CNPH*2417A**
CNPH*3017A**
CSPH*2412A**
CSPH*3012A**
CNPH*2417A**
1.80
1.00
8.42
1.77
1.75
1.72
1.69
1.67
1.64
1.61
1.60
Capacity
9.16
900
8.25
8.07
8.81
8.64
8.44
9.16
8.99
8.81
Integ*
Total
Sys.
KW†
*FY4ANF030
8.97
8.77
700
800
9.58
900
9.18
700
9.40
9.95
900
800
9.77
9.57
Total
Capacity MBtuh
800
700
CFM
-- 3 ( -- 19.4)
Heating Indoor Model
75
70
65
EDB
INDOOR AIR
0.94
0.94
0.93
0.94
0.94
0.94
0.94
0.94
0.94
0.94
0.94
0.94
0.95
0.95
0.95
0.95
0.95
0.95
0.95
0.95
0.95
0.95
0.96
0.96
0.96
1.17
1.00
0.98
1.00
1.00
1.00
1.01
1.01
1.01
0.93
0.96
0.92
0.92
0.92
0.92
1.00
Power
11.79
11.59
11.37
12.15
11.96
11.73
12.48
12.29
12.07
Total
Furnace Model
1.84
1.82
1.81
1.75
1.73
1.72
1.66
1.65
1.64
Total
Sys.
KW†
58CV(A,X)135 ---22
58CV(A,X)110 ---20
58CV(A,X)110 ---20
58CV(A,X)110 ---20
58CV(A,X)110 ---20
58CV(A,X)090 ---16
58CV(A,X)090 ---16
58CV(A,X)090 ---16
58CV(A,X)090 ---16
58CV(A,X)090 ---16
58CV(A,X)090 ---16
58CV(A,X)090 ---16
58CV(A,X)090 ---16
58CV(A,X)070 ---12
58CV(A,X)070 ---12
58CV(A,X)070 ---12
58CV(A,X)070 ---12
58CV(A,X)070 ---12
58CV(A,X)070 ---12
58CV(A,X)070 ---12
58CV(A,X)070 ---12
58CV(A,X)070 ---12
58CV(A,X)070 ---12
58CV(A,X)070 ---12
58CV(A,X)070 ---12
10.84
10.65
10.45
11.17
10.99
10.78
11.47
11.29
11.10
Integ*
Capacity MBtuh
7 ( -- 13.9)
14.50
14.26
14.02
14.81
14.60
14.38
15.13
14.92
14.70
Total
1.87
1.86
1.86
1.78
1.77
1.76
1.68
1.67
1.67
Total
Sys.
KW†
Total
Sys.
KW†
37 (2.8)
Total
Integ*
Capacity MBtuh
17.35
17.10
16.84
17.65
17.43
17.18
17.94
17.73
17.48
See notes on pg. 26
CSPH*3012A**
CSPH*2412A**
CNPH*3017A**
CNPH*2417A**
CSPH*3012A**
CSPH*2412A**
CNPH*3017A**
CNPH*2417A**
CSPH*3012A**
CSPH*2412A**
CNPH*3017A**
CNPH*2417A**
CSPH*3012A**
CSPH*2412A**
CNPH*3017A**
CNPH*2417A**
CSPH*3012A**
CSPH*2412A**
CNPV*3017A**
CNPV*2417A**
CNPH*3017A**
CNPH*2417A**
CAP**3017A**
CAP**2417A**
CSPH*3012A**
CSPH*2412A**
CNPH*3017A**
CNPH*2417A**
CSPH*3012A**
CSPH*2412A**
CNPH*3017A**
CNPH*2417A**
CSPH*3012A**
CSPH*2412A**
CNPH*3017A**
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
Capacity
15.41
15.19
14.96
15.68
15.48
15.26
15.94
15.75
15.53
1.90
1.90
1.91
1.80
1.80
1.81
1.71
1.71
1.71
0.95
0.95
0.95
0.95
0.94
0.94
0.94
0.94
0.95
0.94
0.95
0.95
0.95
0.94
0.94
0.94
0.95
0.94
0.95
0.94
0.95
0.94
0.95
0.96
0.95
0.94
0.94
0.94
0.94
0.94
0.94
0.94
0.94
0.93
0.94
Power
20.37
20.23
19.84
20.75
20.48
20.17
21.14
20.86
20.55
1.94
1.95
1.97
1.84
1.85
1.86
1.74
1.75
1.77
Total
Sys.
KW†
58MVB120 ---20
58MVB120 ---20
58MVB120 ---20
58MVB120 ---20
58MVB100 ---20
58MVB100 ---20
58MVB100 ---20
58MVB100 ---20
58MVB080 ---20
58MVB080 ---20
58MVB080 ---20
58MVB080 ---20
58MVB080 ---14
58MVB080 ---14
58MVB080 ---14
58MVB080 ---14
58MVB060 ---14
58MVB060 ---14
58MVB060 ---14
58MVB060 ---14
58MVB060 ---14
58MVB060 ---14
58MVB060 ---14
58MVB060 ---14
58MVB040 ---14
58MVB040 ---14
58MVB040 ---14
58MVB040 ---14
58CV(A,X)155 ---22
58CV(A,X)155 ---22
58CV(A,X)155 ---22
58CV(A,X)155 ---22
58CV(A,X)135 ---22
58CV(A,X)135 ---22
58CV(A,X)135 ---22
Furnace Model
18.54
18.41
18.06
18.89
18.64
18.35
19.23
18.99
18.70
38QRR024 Outdoor Section With FY4ANF024 Indoor Section
Integ*
Capacity MBtuh
27 ( -- 2.8)
OUTDOOR COIL ENTERING AIR TEMPERATURES _F (_C)
Total
Heating Indoor Model
13.22
13.00
12.79
13.50
13.31
13.11
13.79
13.60
13.41
Integ*
Capacity MBtuh
17 ( -- 8.3)
HEAT PUMP HEATING PERFORMANCE (CONT.)
23.89
23.59
23.24
24.31
24.00
23.64
24.73
24.42
24.05
Total
23.89
23.59
23.24
24.31
24.00
23.64
24.73
24.42
24.05
Integ*
Capacity MBtuh
47 (8.3)
38QRR
2.00
2.01
2.04
1.90
1.91
1.94
1.80
1.81
1.84
Total
Sys.
KW†
57 (13.9)
27.88
27.51
27.07
28.37
28.00
27.55
28.85
28.50
28.04
Total
27.88
27.51
27.07
28.37
28.00
27.55
28.85
28.50
28.04
Integ*
Capacity MBtuh
2.08
2.10
2.14
1.97
1.99
2.03
1.87
1.89
1.93
Total
Sys.
KW†
67 (19.4)
32.37
32.01
31.49
32.79
32.52
32.04
33.18
32.95
32.57
Total
32.37
32.01
31.49
32.79
32.52
32.04
33.18
32.95
32.57
Integ*
Capacity MBtuh
2.14
2.18
2.26
2.03
2.07
2.13
1.93
1.96
2.01
Total
Sys.
KW†
25
0.99
1.00
0.98
0.99
0.98
0.99
1.00
0.98
0.99
0.99
0.99
1.01
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.01
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
FE4AN(B,F)003
FE4AN(B,F)005
FE4ANF002
FF1ENP030
FF1ENP036
FV4BN(B,F)003
FV4BN(B,F)005
FX4CN(B,F)036
FX4CNF030
FY4ANF036
CAP**3014A**
CAP**3017A**
CAP**3614A**
CAP**3617A**
CAP**3621A**
CNPF*3618A**
CNPH*3017A**
CNPH*3617A**
CNPV*3014A**
CNPV*3017A**
CNPV*3617A**
CNPV*3621A**
CSPH*3012A**
CSPH*3612A**
40QAQ030
CAP**3014A**
CAP**3017A**
CAP**3614A**
CAP**3617A**
CNPH*3017A**
CNPH*3617A**
CNPV*3014A**
CNPV*3017A**
CNPV*3617A**
CSPH*3012A**
CSPH*3612A**
CAP**3017A**
CAP**3617A**
CAP**3621A**
CNPH*3017A**
0.95
0.94
0.94
0.95
0.92
0.95
0.96
0.96
0.96
0.96
0.96
0.95
0.95
0.96
0.96
1.08
0.96
0.99
1.00
1.00
1.00
1.00
1.00
1.00
0.99
0.99
1.00
1.00
1.01
0.94
0.93
0.89
0.92
1.00
1.01
0.93
0.89
0.92
1.00
2.32
Power
9.96
2.29
2.26
2.23
2.20
2.17
2.14
2.11
2.08
1.00
10.82
1125
9.74
9.51
10.44
10.22
9.99
10.89
10.68
10.44
Integ*
Total
Sys.
KW†
Capacity
10.58
10.33
875
1000
11.35
1125
10.86
875
11.11
11.83
1125
1000
11.60
11.35
Total
Capacity MBtuh
1000
875
CFM
-- 3 ( -- 19.4)
Heating
Indoor Model
*FY4ANF030
75
70
65
EDB
INDOOR AIR
13.95
13.71
13.43
14.43
14.19
13.91
14.87
14.63
14.36
Total
2.32
2.30
2.28
2.22
2.20
2.18
2.13
2.10
2.09
Total
Sys.
KW†
58CV(A,X)090 ---16
58CV(A,X)090 ---16
58CV(A,X)090 ---16
58CV(A,X)090 ---16
58CV(A,X)070 ---12
58CV(A,X)070 ---12
58CV(A,X)070 ---12
58CV(A,X)070 ---12
58CV(A,X)070 ---12
58CV(A,X)070 ---12
58CV(A,X)070 ---12
58CV(A,X)070 ---12
58CV(A,X)070 ---12
58CV(A,X)070 ---12
58CV(A,X)070 ---12
Furnace Model
12.82
12.59
12.34
13.26
13.04
12.78
13.67
13.44
13.20
Integ*
Capacity MBtuh
7 ( -- 13.9)
17.21
16.96
16.65
17.65
17.40
17.10
18.08
17.82
17.52
Total
Total
Integ*
Capacity MBtuh
27 ( -- 2.8)
Total
Sys.
KW†
Total
Integ*
Capacity MBtuh
37 (2.8)
2.32
2.30
2.29
2.21
2.20
2.19
2.11
2.10
2.09
CAP**3621A**
CSPH*3612A**
CSPH*3012A**
CNPV*3621A**
CNPH*3617A**
CNPH*3017A**
CAP**3621A**
CSPH*3612A**
CSPH*3012A**
CNPV*3621A**
CNPV*3617A**
CNPV*3017A**
CNPH*3617A**
CNPH*3017A**
CAP**3621A**
CAP**3617A**
CAP**3017A**
CSPH*3612A**
CSPH*3012A**
CNPH*3617A**
CNPH*3017A**
CSPH*3612A**
CSPH*3012A**
CNPH*3617A**
CNPH*3017A**
CSPH*3612A**
CSPH*3012A**
CNPH*3617A**
CNPH*3017A**
CSPH*3612A**
CSPH*3012A**
CNPV*3621A**
CNPH*3617A**
CNPH*3017A**
CAP**3621A**
CSPH*3612A**
CSPH*3012A**
CNPV*3621A**
CNPV*3617A**
CNPV*3017A**
18.37
18.09
17.81
18.73
18.49
18.20
19.09
18.84
18.57
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
Capacity
20.68
20.37
20.05
21.08
20.82
20.49
21.49
21.21
20.91
0.94
0.92
0.95
0.95
0.95
0.95
0.94
0.92
0.95
0.96
0.96
0.96
0.96
0.96
0.95
0.95
0.96
0.93
0.96
0.96
0.96
0.91
0.94
0.94
0.94
0.91
0.94
0.94
0.94
0.91
0.94
0.94
0.95
0.95
0.94
0.92
0.95
0.95
0.95
0.95
0.95
Power
2.31
2.30
2.31
2.20
2.20
2.20
2.10
2.09
2.10
24.31
23.99
23.64
24.77
24.44
24.07
25.25
24.90
24.53
2.31
2.31
2.33
2.20
2.20
2.22
2.10
2.10
2.11
58MVB080 ---20
58MVB080 ---14
58MVB080 ---14
58MVB080 ---14
58MVB080 ---14
58MVB080 ---14
58MVB080 ---14
58MVB060 ---14
58MVB060 ---14
58MVB060 ---14
58MVB060 ---14
58MVB060 ---14
58MVB060 ---14
58MVB060 ---14
58MVB060 ---14
58MVB060 ---14
58MVB060 ---14
58MVB040 ---14
58MVB040 ---14
58MVB040 ---14
58MVB040 ---14
58CV(A,X)155 ---22
58CV(A,X)155 ---22
58CV(A,X)155 ---22
58CV(A,X)155 ---22
58CV(A,X)135 ---22
58CV(A,X)135 ---22
58CV(A,X)135 ---22
58CV(A,X)135 ---22
58CV(A,X)110 ---20
58CV(A,X)110 ---20
58CV(A,X)110 ---20
58CV(A,X)110 ---20
58CV(A,X)110 ---20
58CV(A,X)110 ---20
58CV(A,X)090 ---16
58CV(A,X)090 ---16
58CV(A,X)090 ---16
58CV(A,X)090 ---16
58CV(A,X)090 ---16
58CV(A,X)090 ---16
Furnace Model
22.12
21.83
21.51
22.54
22.24
21.90
22.98
22.66
22.32
Total
Sys.
KW†
OUTDOOR COIL ENTERING AIR TEMPERATURES _F (_C)
38QRR030 Outdoor Section With FY4ANF030 Indoor Section
Total
Sys.
KW†
Heating
Indoor Model
CNPH*3617A**
15.69
15.46
15.18
16.09
15.86
15.59
16.48
16.25
15.97
Integ*
Capacity MBtuh
17 ( -- 8.3)
HEAT PUMP HEATING PERFORMANCE (CONT.)
47 (8.3)
2.33
2.34
2.36
2.22
2.23
2.25
2.12
2.12
2.15
38QRR
CSPH*3612A**
CSPH*3012A**
CNPH*3617A**
CNPH*3017A**
CSPH*3612A**
CSPH*3012A**
CNPV*3621A**
CNPH*3617A**
CNPH*3017A**
CAP**3621A**
CSPH*3612A**
CSPH*3012A**
CNPV*3621A**
CNPH*3617A**
Heating
Indoor Model
CNPH*3017A**
28.47
28.10
27.58
28.97
28.60
28.17
29.48
29.11
28.67
Integ*
Total
Sys.
KW†
See notes on pg. 26
28.47
28.10
27.58
28.97
28.60
28.17
29.48
29.11
28.67
Total
Capacity MBtuh
57 (13.9)
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
Capacity
32.94
32.51
31.99
33.50
33.08
32.56
34.09
33.65
33.12
Total
32.94
32.51
31.99
33.50
33.08
32.56
34.09
33.65
33.12
Integ*
Capacity MBtuh
0.92
0.95
0.95
0.95
0.92
0.95
0.95
0.95
0.95
0.94
0.92
0.95
0.95
0.95
0.95
Power
2.35
2.37
2.40
2.25
2.26
2.29
2.15
2.16
2.19
Total
Sys.
KW†
67 (19.4)
37.88
37.38
36.77
38.53
38.03
37.41
39.18
38.68
38.07
Total
58MVB120 ---20
58MVB120 ---20
58MVB120 ---20
58MVB120 ---20
58MVB100 ---20
58MVB100 ---20
58MVB100 ---20
58MVB100 ---20
58MVB100 ---20
58MVB100 ---20
58MVB080 ---20
58MVB080 ---20
58MVB080 ---20
58MVB080 ---20
58MVB080 ---20
Furnace Model
37.88
37.38
36.77
38.53
38.03
37.41
39.18
38.68
38.07
Integ*
Capacity MBtuh
2.39
2.42
2.46
2.29
2.31
2.35
2.19
2.21
2.25
Total
Sys.
KW†
26
0.95
0.95
0.96
0.98
0.98
0.97
0.96
0.98
0.98
0.97
0.98
0.99
1.01
0.99
0.99
1.00
1.00
0.99
0.99
1.00
0.99
0.99
1.00
0.99
1.00
0.93
0.96
0.97
0.96
0.97
0.97
0.96
0.97
0.96
0.96
0.97
0.96
0.96
0.96
0.96
0.96
0.96
FE4AN(B,F)003
FE4AN(B,F)005
FE4ANB006
FE4ANF002
FV4BN(B,F)003
FV4BN(B,F)005
FV4BNB006
FV4BNF002
FX4CN(B,F)036
FX4CN(B,F)042
FY4ANF042
CAP**3617A**
CAP**3621A**
CAP**4221A**
CAP**4224A**
CNPF*3618A**
CNPH*3617A**
CNPH*4221A**
CNPV*3617A**
CNPV*3621A**
CNPV*4221A**
CSPH*3612A**
CSPH*4212A**
40QAQ036
CAP**3614A**
CAP**3617A**
CNPH*3617A**
CNPH*4221A**
CNPV*3617A**
CSPH*3612A**
CSPH*4212A**
CAP**3617A**
CAP**3621A**
CAP**4221A**
CNPH*3617A**
CNPH*4221A**
CNPV*3617A**
CNPV*3621A**
CNPV*4221A**
CSPH*3612A**
0.90
0.90
0.94
0.94
0.90
0.94
0.92
0.92
0.93
0.91
0.91
0.95
0.92
0.95
1.02
0.95
0.95
0.97
0.98
0.98
0.97
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.90
0.92
0.94
0.85
0.87
0.91
0.94
0.85
0.87
0.91
1.00
2.67
Power
11.29
2.63
2.59
2.56
2.52
2.48
2.45
2.41
2.38
1.00
12.27
1350
11.02
10.72
11.87
11.60
11.30
12.37
12.14
11.88
Integ*
Total
Sys.
KW†
Capacity
11.98
11.65
1050
1200
12.90
1350
12.29
1050
12.61
13.45
1350
1200
13.20
12.91
Total
Capacity MBtuh
1200
1050
CFM
-- 3 ( -- 19.4)
Heating Indoor
Model
*FY4ANF036
75
70
65
EDB
INDOOR AIR
15.99
15.67
15.30
16.70
16.34
15.93
17.12
16.82
16.52
Total
58CV(A,X)090 ---16
58CV(A,X)090 ---16
58CV(A,X)090 ---16
58CV(A,X)090 ---16
58CV(A,X)090 ---16
58CV(A,X)090 ---16
58CV(A,X)090 ---16
58CV(A,X)090 ---16
58CV(A,X)090 ---16
58CV(A,X)070 ---12
58CV(A,X)070 ---12
58CV(A,X)070 ---12
58CV(A,X)070 ---12
58CV(A,X)070 ---12
58CV(A,X)070 ---12
58CV(A,X)070 ---12
2.72
2.69
2.66
2.61
2.57
2.54
2.49
2.45
2.43
Total
Sys.
KW†
Furnace Model
14.69
14.40
14.06
15.34
15.01
14.64
15.73
15.45
15.18
Integ*
Capacity MBtuh
7 ( -- 13.9)
19.98
19.63
19.23
20.55
20.20
19.80
21.09
20.74
20.35
Total
Total
Integ*
Capacity MBtuh
27 ( -- 2.8)
Total
Sys.
KW†
Total
Integ*
Capacity MBtuh
37 (2.8)
2.77
2.74
2.73
2.64
2.62
2.60
2.52
2.50
2.48
CNPV*4221A**
CNPV*3621A**
CNPH*4221A**
CAP**4224A**
CAP**4221A**
CAP**3621A**
CSPH*4212A**
CSPH*3612A**
CNPV*4221A**
CNPV*3621A**
CNPV*3617A**
CNPH*4221A**
CNPH*3617A**
CAP**4221A**
CAP**3621A**
CAP**3617A**
CSPH*4212A**
CSPH*3612A**
CNPH*4221A**
CNPH*3617A**
CAP**4224A**
CSPH*4212A**
CSPH*3612A**
CNPH*4221A**
CNPH*3617A**
CAP**4224A**
CSPH*4212A**
CSPH*3612A**
CNPH*4221A**
CNPH*3617A**
CAP**4224A**
CSPH*4212A**
CSPH*3612A**
CNPV*4221A**
CNPV*3621A**
CNPH*4221A**
CNPH*3617A**
CAP**4224A**
CAP**4221A**
CAP**3621A**
0.97
0.96
0.97
0.97
0.96
0.96
0.97
0.96
0.97
0.96
0.96
0.97
0.96
0.97
0.96
0.96
0.97
0.96
0.97
0.96
0.97
0.97
0.96
0.96
0.96
0.96
0.97
0.96
0.96
0.96
0.96
0.97
0.96
0.97
0.96
0.97
0.96
0.97
0.96
0.96
0.97
Capacity
24.33
23.95
23.51
24.89
24.51
24.08
25.41
25.03
24.61
0.92
0.96
0.92
0.94
0.93
0.94
0.90
0.91
0.91
0.94
0.94
0.91
0.94
0.93
0.93
0.94
0.91
0.92
0.92
0.95
0.93
0.88
0.89
0.89
0.93
0.90
0.89
0.89
0.89
0.93
0.91
0.89
0.89
0.90
0.93
0.90
0.93
0.91
0.91
0.92
0.89
Power
21.61
21.27
20.88
22.10
21.76
21.39
22.57
22.23
21.86
2.81
2.80
2.80
2.68
2.67
2.67
2.56
2.54
2.54
26.44
26.06
25.62
26.93
26.56
26.13
27.42
27.05
26.61
58MVB080 ---14
58MVB080 ---14
58MVB080 ---14
58MVB080 ---14
58MVB080 ---14
58MVB080 ---14
58MVB060 ---14
58MVB060 ---14
58MVB060 ---14
58MVB060 ---14
58MVB060 ---14
58MVB060 ---14
58MVB060 ---14
58MVB060 ---14
58MVB060 ---14
58MVB060 ---14
58MVB040 ---14
58MVB040 ---14
58MVB040 ---14
58MVB040 ---14
58MVB040 ---14
58CV(A,X)155 ---22
58CV(A,X)155 ---22
58CV(A,X)155 ---22
58CV(A,X)155 ---22
58CV(A,X)155 ---22
58CV(A,X)135 ---22
58CV(A,X)135 ---22
58CV(A,X)135 ---22
58CV(A,X)135 ---22
58CV(A,X)135 ---22
58CV(A,X)110 ---20
58CV(A,X)110 ---20
58CV(A,X)110 ---20
58CV(A,X)110 ---20
58CV(A,X)110 ---20
58CV(A,X)110 ---20
58CV(A,X)110 ---20
58CV(A,X)110 ---20
58CV(A,X)110 ---20
58CV(A,X)090 ---16
Furnace Model
29.05
28.63
28.15
29.60
29.19
28.71
30.14
29.72
29.25
2.87
2.86
2.88
2.73
2.73
2.74
2.60
2.60
2.61
Total
Sys.
KW†
OUTDOOR COIL ENTERING AIR TEMPERATURES _F (_C)
38QRR036 Outdoor Section With FY4ANF036 Indoor Section
Total
Sys.
KW†
Heating Indoor
Model
CSPH*4212A**
18.22
17.89
17.53
18.74
18.42
18.05
19.22
18.91
18.56
Integ*
Capacity MBtuh
17 ( -- 8.3)
HEAT PUMP HEATING PERFORMANCE (CONT.)
CSPH*4212A**
CSPH*3612A**
CNPH*4221A**
CNPH*3617A**
CAP**4224A**
CSPH*4212A**
CSPH*3612A**
CNPV*4221A**
CNPV*3621A**
CNPH*4221A**
CNPH*3617A**
CAP**4224A**
CAP**4221A**
CAP**3621A**
CSPH*4212A**
CSPH*3612A**
CNPV*4221A**
CNPV*3621A**
CNPH*4221A**
CNPH*3617A**
CAP**4224A**
CAP**4221A**
CAP**3621A**
CSPH*4212A**
Heating Indoor
Model
CSPH*3612A**
34.24
33.74
33.19
34.90
34.40
33.81
35.63
35.14
34.46
Integ*
2.93
2.94
2.96
2.79
2.80
2.82
2.67
2.67
2.69
Total
Sys.
KW†
57 (13.9)
40.25
39.69
39.02
40.96
40.39
39.71
41.66
41.10
40.41
Total
0.97
0.96
0.96
0.96
0.96
0.97
0.96
0.97
0.96
0.97
0.96
0.97
0.96
0.96
0.97
0.96
0.97
0.96
0.97
0.96
0.97
0.96
0.96
0.97
0.96
0.90
0.90
0.90
0.94
0.92
0.90
0.90
0.91
0.94
0.91
0.94
0.92
0.92
0.93
0.90
0.91
0.92
0.94
0.92
0.94
0.93
0.92
0.93
0.91
0.92
Power
40.25
39.69
39.02
40.96
40.39
39.71
41.66
41.10
40.41
Integ*
Capacity MBtuh
Capacity
See notes on pg. 26
34.24
33.74
33.19
34.90
34.40
33.81
35.63
35.14
34.46
Total
Capacity MBtuh
47 (8.3)
38QRR
3.02
3.04
3.08
2.88
2.90
2.94
2.75
2.76
2.80
Total
Sys.
KW†
67 (19.4)
46.83
46.17
45.37
47.62
46.97
46.15
48.48
47.76
46.94
Integ*
58MVB120 ---20
58MVB120 ---20
58MVB120 ---20
58MVB120 ---20
58MVB120 ---20
58MVB100 ---20
58MVB100 ---20
58MVB100 ---20
58MVB100 ---20
58MVB100 ---20
58MVB100 ---20
58MVB100 ---20
58MVB100 ---20
58MVB100 ---20
58MVB080 ---20
58MVB080 ---20
58MVB080 ---20
58MVB080 ---20
58MVB080 ---20
58MVB080 ---20
58MVB080 ---20
58MVB080 ---20
58MVB080 ---20
58MVB080 ---14
58MVB080 ---14
Furnace Model
46.83
46.17
45.37
47.62
46.97
46.15
48.48
47.76
46.94
Total
Capacity MBtuh
3.13
3.16
3.22
2.98
3.01
3.07
2.85
2.88
2.93
Total
Sys.
KW†
27
75
70
65
0.98
0.99
0.94
0.97
0.97
0.97
0.97
0.97
0.97
0.97
0.97
0.97
0.97
0.97
0.97
0.97
0.97
0.97
0.97
0.97
0.97
CSPH*4812A**
CSPH*6012A**
40QAQ048
CAP**4817A**
CAP**4821A**
CAP**6021A**
CNPH*4821A**
CNPH*6024A**
CNPV*4821A**
CSPH*4812A**
CSPH*6012A**
CAP**4821A**
CAP**4824A**
CAP**6021A**
CAP**6024A**
CNPH*4821A**
CNPH*6024A**
CNPV*4821A**
CNPV*4824A**
CNPV*6024A**
CSPH*4812A**
0.99
CAP**6024A**
0.99
0.96
CAP**6021A**
CNPV*6024A**
0.98
CAP**4824A**
0.98
0.98
CAP**4821A**
CNPV*4824A**
0.98
CAP**4817A**
0.98
0.99
FY4ANF048
CNPV*4821A**
1.00
FY4ANB060
0.99
0.98
FX4CN(B,F)060
CNPH*6024A**
0.98
FX4CN(B,F)048
0.98
0.96
FV4BNB006
CNPH*4821A**
0.96
FV4BN(B,F)005
0.97
0.96
FE4ANB006
CNPF*4818A**
0.96
FE4AN(B,F)005
3.55
1.00
16.39
3.49
3.44
3.41
3.35
3.30
3.26
3.20
3.16
Capacity
17.81
1800
16.01
15.59
17.16
16.78
16.36
17.86
17.46
17.06
Integ*
Total
Sys.
KW†
*FY4ANF048
17.40
16.95
1400
1600
18.65
1800
17.79
1400
18.24
19.41
1800
1600
18.98
18.54
Total
Capacity MBtuh
1600
1400
CFM
-- 3 ( -- 19.4)
Heating Indoor Model
EDB
INDOOR AIR
0.96
0.95
0.96
0.96
0.95
0.96
0.95
0.94
0.96
0.97
0.94
0.96
0.97
0.95
0.97
0.95
0.97
0.96
1.03
0.95
0.96
0.97
0.97
0.97
0.97
0.97
1.00
0.96
0.93
0.97
0.97
0.98
0.99
0.97
0.89
0.93
0.89
0.92
0.89
0.92
1.00
Power
23.03
22.59
22.10
23.77
23.34
22.85
24.45
24.01
23.54
Total
21.16
20.76
20.31
21.84
21.45
21.00
22.47
22.06
21.63
Integ*
Capacity MBtuh
7 ( -- 13.9)
17 ( -- 8.3)
28.57
28.12
27.58
29.26
28.80
28.29
29.87
29.43
28.92
Total
58CV(A,X)110 ---20
58CV(A,X)110 ---20
58CV(A,X)110 ---20
58CV(A,X)110 ---20
58CV(A,X)110 ---20
58CV(A,X)110 ---20
58CV(A,X)110 ---20
58CV(A,X)110 ---20
58CV(A,X)110 ---20
58CV(A,X)110 ---20
58CV(A,X)090 ---16
58CV(A,X)090 ---16
58CV(A,X)090 ---16
58CV(A,X)090 ---16
58CV(A,X)090 ---16
58CV(A,X)090 ---16
58CV(A,X)090 ---16
58CV(A,X)090 ---16
Total
Integ*
Capacity MBtuh
27 ( -- 2.8)
Total
Sys.
KW†
Total
Integ*
Capacity MBtuh
37 (2.8)
3.75
3.72
3.71
3.57
3.54
3.53
3.40
3.37
3.36
34.55
34.06
33.49
35.18
34.70
34.15
35.76
35.28
34.75
CAP**6024A**
CAP**4824A**
CSPH*6012A**
CSPH*4812A**
CNPV*6024A**
CNPV*4824A**
CNPV*4821A**
CNPH*6024A**
CNPH*4821A**
CAP**6024A**
CAP**6021A**
CAP**4824A**
CAP**4821A**
CSPH*6012A**
CSPH*4812A**
CNPV*6024A**
CNPV*4824A**
CNPV*4821A**
CNPH*6024A**
CNPH*4821A**
CAP**6024A**
CAP**6021A**
CAP**4824A**
CAP**4821A**
CSPH*6012A**
CSPH*4812A**
CNPV*6024A**
CNPV*4824A**
CNPH*6024A**
CNPH*4821A**
CAP**6024A**
CAP**4824A**
CSPH*6012A**
CSPH*4812A**
CNPV*6024A**
CNPV*4824A**
CNPH*6024A**
CNPH*4821A**
CAP**6024A**
CAP**4824A**
CSPH*6012A**
0.97
0.97
0.97
0.97
0.97
0.97
0.97
0.97
0.97
0.97
0.97
0.97
0.97
0.97
0.97
0.97
0.97
0.97
0.97
0.97
0.97
0.97
0.97
0.97
0.97
0.97
0.97
0.96
0.97
0.96
0.97
0.96
0.97
0.97
0.97
0.96
0.97
0.96
0.97
0.96
0.97
Capacity
30.69
30.25
29.75
31.24
30.82
30.33
31.76
31.34
30.86
3.85
3.83
3.84
3.66
3.64
3.65
3.47
3.46
3.46
0.96
0.97
0.95
0.97
0.96
0.97
0.97
0.96
0.97
0.95
0.95
0.97
0.98
0.95
0.97
0.96
0.98
0.98
0.96
0.98
0.96
0.96
0.98
0.98
0.92
0.94
0.93
0.94
0.93
0.94
0.93
0.94
0.93
0.95
0.94
0.95
0.94
0.95
0.94
0.95
0.94
Power
40.95
40.43
39.82
41.56
41.04
40.45
42.14
41.63
41.04
3.95
3.95
3.98
3.74
3.75
3.77
3.55
3.55
3.57
58MVB120 ---20
58MVB120 ---20
58MVB100 ---20
58MVB100 ---20
58MVB100 ---20
58MVB100 ---20
58MVB100 ---20
58MVB100 ---20
58MVB100 ---20
58MVB100 ---20
58MVB100 ---20
58MVB100 ---20
58MVB100 ---20
58MVB080 ---20
58MVB080 ---20
58MVB080 ---20
58MVB080 ---20
58MVB080 ---20
58MVB080 ---20
58MVB080 ---20
58MVB080 ---20
58MVB080 ---20
58MVB080 ---20
58MVB080 ---20
58CV(A,X)155 ---22
58CV(A,X)155 ---22
58CV(A,X)155 ---22
58CV(A,X)155 ---22
58CV(A,X)155 ---22
58CV(A,X)155 ---22
58CV(A,X)155 ---22
58CV(A,X)155 ---22
58CV(A,X)135 ---22
58CV(A,X)135 ---22
58CV(A,X)135 ---22
58CV(A,X)135 ---22
58CV(A,X)135 ---22
58CV(A,X)135 ---22
58CV(A,X)135 ---22
58CV(A,X)135 ---22
58CV(A,X)110 ---20
Furnace Model
37.27
36.79
36.24
37.82
37.35
36.81
38.35
37.88
37.35
Total
Sys.
KW†
OUTDOOR COIL ENTERING AIR TEMPERATURES _F (_C)
38QRR048 Outdoor Section With FY4ANF048 Indoor Section
Total
Sys.
KW†
Heating Indoor Model
26.05
25.64
25.15
26.68
26.26
25.79
27.24
26.83
26.37
Integ*
Capacity MBtuh
Furnace Model
3.66
3.61
3.58
3.50
3.45
3.42
3.33
3.29
3.26
Total
Sys.
KW†
HEAT PUMP HEATING PERFORMANCE (CONT.)
47 (8.3)
4.05
4.07
4.13
3.85
3.86
3.91
3.65
3.67
3.71
Total
Sys.
KW†
See notes on pg. 26
CSPH*6012A**
CSPH*4812A**
CNPV*6024A**
CNPV*4824A**
CNPH*6024A**
CNPH*4821A**
Heating Indoor Model
47.90
47.31
46.65
48.64
48.00
47.29
49.54
48.90
48.01
Integ*
38QRR
47.90
47.31
46.65
48.64
48.00
47.29
49.54
48.90
48.01
Total
Capacity MBtuh
57 (13.9)
56.36
55.58
54.69
57.27
56.49
55.57
58.20
57.41
56.46
Total
0.97
0.97
0.97
0.97
0.97
0.97
Capacity
56.36
55.58
54.69
57.27
56.49
55.57
58.20
57.41
56.46
Integ*
Capacity MBtuh
4.21
4.25
4.32
3.99
4.03
4.10
3.79
3.82
3.89
Total
Sys.
KW†
0.95
0.97
0.96
0.97
0.96
0.97
Total
66.14
65.19
64.05
67.24
66.28
65.13
68.36
67.39
66.21
Power
67 (19.4)
4.40
4.46
4.56
4.18
4.23
4.33
3.97
4.02
4.11
Total
Sys.
KW†
58MVB120 ---20
58MVB120 ---20
58MVB120 ---20
58MVB120 ---20
58MVB120 ---20
58MVB120 ---20
Furnace Model
66.14
65.19
64.05
67.24
66.28
65.13
68.36
67.39
66.21
Integ*
Capacity MBtuh
28
9.74
9.82
9.82
9.82
9.82
0.95
9.82
9.82
9.74
9.82
9.74
9.74
9.74
9.74
9.74
9.74
9.74
9.74
9.74
9.74
FV4BNB006
FX4CN(B,F)060
CAP**6021A**
CAP**6024A**
CNPH*6024A**
40QAQ060
CNPV*6024A**
CSPH*6012A**
CAP**6021A**
CAP**6024A**
CNPH*6024A**
CNPV*6024A**
CAP**6024A**
CNPH*6024A**
CNPV*6024A**
CSPH*6012A**
CAP**6024A**
CNPH*6024A**
CNPV*6024A**
CSPH*6012A**
9.44
9.60
9.60
9.56
9.53
9.69
9.69
9.66
9.80
9.80
9.87
9.74
9.56
9.72
0.94
9.72
9.65
9.86
9.34
9.28
9.28
1.00
Power
28.93
28.35
27.71
29.82
29.26
28.66
30.70
30.13
29.51
Total
26.58
26.05
25.47
27.41
26.89
26.33
28.21
27.69
27.12
Integ*
Capacity MBtuh
17 ( -- 8.3)
35.36
34.75
34.08
36.20
35.60
34.94
37.00
36.40
35.74
Total
58CV(A,X)155 ---22
58CV(A,X)155 ---22
58CV(A,X)155 ---22
58CV(A,X)155 ---22
58CV(A,X)135 ---22
58CV(A,X)135 ---22
58CV(A,X)135 ---22
58CV(A,X)135 ---22
58CV(A,X)110 ---20
58CV(A,X)110 ---20
58CV(A,X)110 ---20
32.24
31.69
31.07
33.01
32.46
31.85
33.73
33.19
32.59
Integ*
Capacity MBtuh
Furnace Model
4.28
4.21
4.14
4.11
4.03
3.97
3.94
3.86
3.80
Total
Sys.
KW†
58CV(A,X)110 ---20
7 ( -- 13.9)
Total
Integ*
Capacity MBtuh
27 ( -- 2.8)
Total
Sys.
KW†
Total
Integ*
Capacity MBtuh
37 (2.8)
4.42
4.36
4.32
4.23
4.17
4.12
4.05
3.99
3.94
42.10
41.46
40.75
42.87
42.25
41.55
43.61
42.98
42.30
37.39
36.82
36.19
38.08
37.52
36.90
38.73
38.18
37.57
4.57
4.52
4.49
4.37
4.32
4.29
4.18
4.13
4.10
49.15
48.46
47.94
49.96
49.28
48.50
50.76
50.08
49.30
44.73
44.10
43.63
45.47
44.84
44.13
46.19
45.57
44.86
4.73
4.70
4.70
4.52
4.48
4.47
4.31
4.28
4.27
Total
Sys.
KW†
OUTDOOR COIL ENTERING AIR TEMPERATURES _F (_C)
38QRR060 Outdoor Section With FY4ANF060 Indoor Section
Total
Sys.
KW†
47 (8.3)
56.90
56.15
55.26
57.78
57.00
56.14
58.77
57.95
57.00
Total
56.90
56.15
55.26
57.78
57.00
56.14
58.77
57.95
57.00
Integ*
Capacity MBtuh
4.90
4.89
4.91
4.68
4.66
4.68
4.47
4.45
4.46
Total
Sys.
KW†
57 (13.9)
66.07
65.15
64.10
67.18
66.23
65.14
68.32
67.33
66.22
Total
66.07
65.15
64.10
67.18
66.23
65.14
68.32
67.33
66.22
Integ*
Capacity MBtuh
5.13
5.14
5.18
4.90
4.90
4.94
4.69
4.68
4.71
Total
Sys.
KW†
67 (19.4)
76.45
75.54
74.23
77.49
76.69
75.49
78.45
77.76
76.76
Total
76.45
75.54
74.23
77.49
76.69
75.49
78.45
77.76
76.76
Integ*
Capacity MBtuh
5.33
5.38
5.47
5.09
5.12
5.21
4.86
4.88
4.96
Total
Sys.
KW†
* Tested combination.
{ The kW values include the compressor, outdoor fan motor, and indoor blower motor. The kW from supplement heaters should be added to these values to obtain total system kilowatts.
}The Btuh heating capacity values shown are net integrated values from which the defrost effect has been subtracted. The Btuh heating from supplement heaters should be added to those values to obtain total system capacity.
NOTE: When the required data falls between the published data, interpolation may be performed. Extrapolation is not an acceptable practice.
EDB — Entering Dry Bulb
9.74
FE4ANB006
4.13
1.00
20.88
4.04
3.96
3.98
3.89
3.81
3.82
3.73
3.66
Capacity
22.69
2250
20.37
19.81
21.86
21.34
20.79
22.76
22.24
21.70
Integ*
Total
Sys.
KW†
*FY4ANB060
22.14
21.54
1750
2000
23.76
2250
22.60
1750
23.20
24.74
2250
2000
24.18
23.58
Total
Capacity MBtuh
2000
1750
CFM
-- 3 ( -- 19.4)
Heating Indoor Model
75
70
65
EDB
INDOOR AIR
HEAT PUMP HEATING PERFORMANCE (CONT.)
38QRR
System Description
Outdoor--mounted, air--cooled, split--system heat pump unit
suitable for ground or rooftop installation. Unit consists of a
scroll--type hermetic compressor, an air--cooled coil,
propeller--type condenser fan, and a control box. Unit will
discharge supply air horizontally as shown on contract drawings.
Unit will be used in a refrigeration circuit to match up to a
packaged fan coil or furnace.
Quality Assurance
— Unit will be rated in accordance with the latest edition
of ARI Standard 210.
— Unit will be certified for capacity and efficiency, and
listed in the latest ARI directory.
— Unit construction will comply with latest edition of
ANSI/ ASHRAE and with NEC.
— Unit will be constructed in accordance with UL
standards and will carry the UL label of approval. Unit
will have c--UL approval.
— Unit cabinet will be capable of withstanding Federal
Test
Method Standard No. 141 (Method 6061) 500--hr salt
spray test.
— Air--cooled condenser coils will be leak tested and
pressure tested
— Unit constructed in ISO9001 approved facility.
Delivery, Storage, and Handling
— Unit will be shipped as single package only and is
stored and handled per unit manufacturer’s
recommendations.
Warranty (for inclusion by specifying engineer)
— U.S. and Canada only.
PRODUCTS
Equipment
— Factory assembled, single piece, air--cooled heat pump
unit. Contained within the unit enclosure is all factory
wiring, piping, controls, compressor, refrigerant charge
Puronr (R--410A), and special features required prior
to field start--up.
Unit Cabinet
— Unit cabinet will be constructed of galvanized steel,
bonderized, and coated with a powder coat paint.
Fans
— Condenser fan will be direct--drive propeller type,
discharging air horizontally.
AIR--COOLED, SPLIT--SYSTEM HEAT PUMP
38QRR
1--1/2 TO 5 NOMINAL TONS
— Condenser fan motors will be totally enclosed, 1--phase
type with class B insulation and permanently lubricated
bearings. Shafts will be corrosion resistant.
— Fan blades will be statically and dynamically balanced.
— Condenser fan openings will be equipped with coated
steel wire safety guards.
Compressor
— Compressor will be a scroll--type, hermetically sealed.
— Compressor will be mounted on rubber vibration
isolators.
Condenser Coil
— Condenser coil will be air cooled.
— Coil will be constructed of aluminum fins mechanically
bonded to copper tubes which are then cleaned,
dehydrated, and sealed.
Refrigeration Components
— Refrigeration circuit components will include
liquid--line front--seating shutoff valve with sweat
connections, vapor--line front--seating shutoff valve
with sweat connections, system charge of Puronr
(R--410A) refrigerant, and compressor oil.
— Unit will be equipped with high--pressure switch, low
pressure switch and filter drier for Puron refrigerant.
Operating Characteristics
— The capacity of the unit will meet or exceed _____
Btuh at a suction temperature of _____ _F/_C. The
power consumption at full load will not exceed _____
kW.
— Combination of the unit and the evaporator or fan coil
unit will have a total net cooling capacity of _____
Btuh or greater at conditions of _____ CFM entering
air temperature at the evaporator at _____ _F/_C wet
bulb and _____ _F/_C dry bulb, and air entering the
unit at _____ _F/_C.
— The system will have a SEER of _____ Btuh/watt or
greater at DOE conditions.
Electrical Requirements
— Nominal unit electrical characteristics will be _____ v,
single phase, 60 hz. The unit will be capable of
satisfactory operation within voltage limits of _____ v
to _____ v.
— Nominal unit electrical characteristics will be _____ v,
three phase, 60 hz. The unit will be capable of
satisfactory operation within voltage limits of _____ v
to _____ v.
— Unit electrical power will be single point connection.
— Control circuit will be 24v.
Special Features
— Refer to section of this literature identifying accessories
and descriptions for specific features and available
enhancements.
29
38QRR
GUIDE SPECIFICATIONS
GENERAL
38QRR
Copyright 2007 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231
Printed in U.S.A.
Edition Date: 04/07
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.