CP backup procedure

Comments

Content

Procedure Manual
MEDITEL LOGO TITLE: General Switch O&M CP Backup Procedure on APG40

Document Code: SWT/INT-002 Document Revision: Version 1.0

Date Issued: August 2005 Date Effective: August 2005

CP BACKUP PROCEDURE On APG40

APPROVAL

:

______________________

:

______________________

INFORMATION PROPERTY OF MEDITEL All rights reserved. Page 1 of 9

Procedure Manual
MEDITEL LOGO TITLE: General Switch O&M CP Backup Procedure on APG40

Document Code: SWT/INT-002 Document Revision: Version 1.0

Date Issued: August 2005 Date Effective: August 2005

Table of Contents
Document History ..................................................................................................................3 DISTRIBUTION........................................................................................................................3 1 Introduction...........................................................................................................................4
1.1 OBJECTIVE.................................................................................................................................................................................4 1.2 PEREQUISITES.....................................................................................................................................................................4 1.3 OVERVIEW...........................................................................................................................................................................4

2 PROCEDURES ....................................................................................................................5
2.1 CP BACKUP..........................................................................................................................................................................5

3 Terminology..........................................................................................................................9

INFORMATION PROPERTY OF MEDITEL All rights reserved. Page 2 of 9

Procedure Manual
MEDITEL LOGO TITLE: General Switch O&M CP Backup Procedure on APG40

Document Code: SWT/INT-002 Document Revision: Version 1.0

Date Issued: August 2005 Date Effective: August 2005

DOCUMENT HISTORY
Edition Version 1.0 Date Aug. 2005 Details Compiled by EMMANUEL Omunizua

DISTRIBUTION
NAME Mohammed Elasmai DESIGNATION Switch Mgr. SIGNATURE

INFORMATION PROPERTY OF MEDITEL All rights reserved. Page 3 of 9

Procedure Manual
MEDITEL LOGO TITLE: General Switch O&M CP Backup Procedure on APG40

Document Code: SWT/INT-002 Document Revision: Version 1.0

Date Issued: August 2005 Date Effective: August 2005

1 INTRODUCTION
1.1 OBJECTIVE
This manual is aimed at outlining the various procedures and/or routines required to be carried out on the APG daily or when due.

1.2

PEREQUISITES
• • • AXE COMMANDS HANDLING OF APG APG CP file system (CPF)

It is assumed that the user of this Guide would have been familiar with:

Hardware • Software • • • • TMOS OR WINFIOL TERMINAL ALEX LIBRARY Telnet program -PC ANYWHERE USER MUST BE DEFINED ON THE APG DAT TAPE

1.3

OVERVIEW

The procedure will give guidelines to the OMC Engineer on CP backup operation on the APG40.

INFORMATION PROPERTY OF MEDITEL All rights reserved. Page 4 of 9

Procedure Manual
MEDITEL LOGO TITLE: General Switch O&M CP Backup Procedure on APG40

Document Code: SWT/INT-002 Document Revision: Version 1.0

Date Issued: August 2005 Date Effective: August 2005

2 PROCEDURES
2.1 CP BACKUP
Period: WEEKLY (Every Friday) Reason: To transfer updated switch backup from the Hard disk to DAT tape for safe keeping. Reference:

Step No
1

Step details CP Backup
Open a command log file to save all work. If logged in from OSS, skip steps 2 to 4, go to step 6.

Reference

2

Verify to which node you are connected. Type at the C:\> prompt: C:\> hostname  the response would be either “<nodename>a” or “<nodename>b”, indicating either the A or B node. e.g. “saind1hap1a” or “saind1hap1b”

3

Print working state of the node: C:\> prcstate A response “passive” or “active” indicates the state of the node.

4

Check the CP files defined for RELFSWn, n=0,1,2,… C:\>cpfls –l ! Relfsw0, 1 and 2 should be listed !

5

Go in to CP mode: C:\>mml  You should get the normal AXE terminal prompt “<”

6

Deactivate Auto Dump: SYBUE; Print CP states: DPWSP;

7

Print RELFWSn file information: SYBFP:FILE;

8

Start Backup SYBUP:FILE=RELFSWx; ! usually, x=2 !
INFORMATION PROPERTY OF MEDITEL All rights reserved. Page 5 of 9

Procedure Manual
MEDITEL LOGO TITLE: General Switch O&M CP Backup Procedure on APG40

Document Code: SWT/INT-002 Document Revision: Version 1.0

Date Issued: August 2005 Date Effective: August 2005

Step No
9

Step details CP Backup
Check to see if Backup is finished
Should get BACKUP INFORMATION OUTPUT EXECUTED print out.

Reference

Use SYBFP:FILE; ! To confirm !

INFORMATION PROPERTY OF MEDITEL All rights reserved. Page 6 of 9

Procedure Manual
MEDITEL LOGO TITLE: General Switch O&M CP Backup Procedure on APG40

Document Code: SWT/INT-002 Document Revision: Version 1.0

Date Issued: August 2005 Date Effective: August 2005

Step No
10a

Step details CP Backup
Copy Backup to Tape: Log on to the active node using PC Anywhere Note active node from printout in step 3! Insert DAT tape into tape drive on the Active node go to Start | Programs | Administrative tools (common) | Backup

Reference

! Wait for the tape to fully initialize ! From the window pane, select drives”. Navigate to L:\FMS\DATA\CPF\RELVLOUMSW\RELFSW2 folder.

INFORMATION PROPERTY OF MEDITEL All rights reserved. Page 7 of 9

Procedure Manual
MEDITEL LOGO TITLE: General Switch O&M CP Backup Procedure on APG40

Document Code: SWT/INT-002 Document Revision: Version 1.0

Date Issued: August 2005 Date Effective: August 2005

Step No

Step details CP Backup

Reference

10b

In the view pane, select details to ensure it is the recent backup. Select the Relfsw2 folder. 11 Start Backup to tape Select Backup. A backup information window will come up) select ‘verify after backup’, ‘replace/append’ –if you want to append to existing contents on the tape. Enter in the description field, where “RELFSW_BACKUP”. Leave other values as they are. A report window would come up and notify you when backup is finished. Alternatively, using commands: C:\>ntbackup backup L:\FMS\data\CPF\RELVOLUMSW\RELFSW2 /v /d "RELFSW_BACKUP" /b /hc:on /t normal /tape:0 ! where “RELFSW_BACKUP” is the description ! To check if backup is finished using command: C:\>ps ! ntbackup will be listed as among the running processes if backup is still running ! 12 Check to see if backup is completed. C:\>ps  If NTBACKUP is no longer listed among the processes running, the backup is completed. Eject the tape with the eject button and store safely. 13 Update the Switch Records END.
INFORMATION PROPERTY OF MEDITEL All rights reserved. Page 8 of 9

Procedure Manual
MEDITEL LOGO TITLE: General Switch O&M CP Backup Procedure on APG40

Document Code: SWT/INT-002 Document Revision: Version 1.0

Date Issued: August 2005 Date Effective: August 2005

3 TERMINOLOGY
. Terms/Abbreviations APG Explanation Adjunct Processor Group: consist of one small NT domain with only two computers (Node A and Node B). Node A acts as the Primary Domain Controller, while Node B acts as the Backup. Ericsson Active Library Explorer. Should have R9.1 database. Operational Instruction: from ALEX.

ALEX OPI