MINIMUM STOCKABLE, USABLE, and CERTIFIABLE VINTAGES
FOR DEFINITY® G3/ DEFINITY One®/ Avaya™ IP 600/ Avaya MultiVantage™/ Avaya™ Communication Manager Avaya S8300 Media Server and Media Modules
COMPAS™ ID: 42751 Issue 32, June 27, 2011 B.A. White T. Wie
Notes:
1. Changes from the previous issue of this document are indicated by bold italicized text. 2. The "Release Version" column indicates: A. The first software release that supports the board code, or B. The first software release that supports the additional functionality introduced with the suffix of the board. The software release entry in the Release Version column does NOT indicate that this board is required for that software release. Lower board suffixes (e.g. "B" vs. "C") may be used unless otherwise specified in the "Warning" column. 3. Vintages noted as H3F2 mean Hardware Vintage 3, Firmware Vintage 2. NOTE: If a pack using this vintage notation is placed in switch running a release of software that does not recognize this notation, the hardware and firmware vintages will be added together and reported. E.G. TN464GP H3F6 would be reported as TN464G V9 in a R7 switch. 4. Useable vintages associated with upgrades: When a minimum vintage circuit pack change out is required to make a system compatible for an upgrade there will be one of two ways to order. 1. PCN: If there is an associated PCN and the customer is experiencing problems associated with the PCN then the circuit pack(s) will be changed out under the PCN. 2. SAP: If no PCN applies, the minimum vintage packs will have to be ordered when placing the upgrade order and will be ordered by material codes through SAP. The minimum vintage circuit packs are chargeable. 5. Vintage Matching: In almost all instances, boards used in duplicated systems do not have to have matching vintages as long as the minimum usable vintage requirements are met. Exceptions to this rule are identified in this document. 6. Suffix Matching: Unless specifically prohibited in this document, different suffix boards can be mixed as long as minimum usable vintage requirements/warnings are met. E.G. TN570B, TN570C, and TN570D all inter-operate.
SYSTEM 75/DEFINITY G 1.1, G3, R5, R6, R7, R8, R9, SYSTEM 75/DEFINITY® G 1.1, G3, R5, R6, R7, R8, R9, R10.1, IP600 Definity One® R1, R2, R3, MultiVantage™, and Avaya™ Communication Manager CARRIER AND CABINET LEVEL CIRCUIT MODULES
DEFINITY® G3, R5, R6, R7, R8, R9, R10.1, IP600 Definity One® R1, R2, & R3, MultiVantage™, and Avaya™ Communication Manager Carrier and Cabinet Level Circuit Modules
Apparatus code
Description
COMCODE RELEASE (non-GSA) VERSION
(see Note 2 on the cover page)
CERTIFIA CHANGE NOTICE MIN. MIN. BLE STOCK USABLE VINTAGE VINTAG VINTAGE E
Warning
Comments/ Old Change Notices
105B 116A
Isolating Data Interface DC Ground Isolator
105778179 V1,2,3. G1, G3 106005242 G1,G3
n/a n/a
n/a n/a
n/a n/a Required to connect SAT to DC systems 1359B H1 Upgrade Requires TN464E or TN767D for Basic ICSU. TN464F or TN767E for Enhanced ICSU 120A3 with S/N 01DR09XXXXXX through 02DR04XXXXXX to 120A3A Requires TN464E or TN767D for Basic ICSU. TN464F or TN767E for Enhanced ICSU Requires TN464E or TN767D for Basic ICSU. TN464F or TN767E for Enhanced ICSU 122A Music-On-Hold Interface can only be used in France. Must use 300A on both ends can only be used with TN776 and up to 7000 ft. Requires 4A on both ends can only be used with TN776 and up to 7000 ft. Requires 4B on both ends can only be used with TN776 and up to 7000 ft. Requires 4C on both ends can only be used with TN776 and up to 7000 ft. Requires 4D on both ends can only be used with TN776 and up to 7000 ft. Requires 4E on both ends can only be used with TN776 and up to 7000 ft. Requires 4F on both ends
SYSTEM 75/DEFINITY G 1.1, G3, R5, R6, R7, R8, R9, SYSTEM 75/DEFINITY® G 1.1, G3, R5, R6, R7, R8, R9, R10.1, IP600 Definity One® R1, R2, R3, MultiVantage™, and Avaya™ Communication Manager CARRIER AND CABINET LEVEL CIRCUIT MODULES
Apparatus code
Description
COMCODE RELEASE (non-GSA) VERSION
(see Note 2 on the cover page)
CERTIFIA CHANGE NOTICE MIN. MIN. BLE STOCK USABLE VINTAGE VINTAG VINTAGE E
Warning
Comments/ Old Change Notices
403A
75 Ohm E1 Splitter (ATM)
108508102 R7.1 848254942 R7.1si
1
1
1 See TN2400 (cc 108305814) or TN794 (cc 103557476) for replacement. Used only when upgrading from pre R7.1si to R7.x si
84825494 Net/Pkt Assembly 2
see see see TN2400 TN2400 TN2400 & TN794 & TN794 & TN794
84848680 Net/Pkt Assembly 9
848486809 R9.1 si
9823A 9823B CFY1 CFY1B CPP1 NAA1 TN417
Lightwave Transceiver Lightwave Transceiver CURRENT LIMITER CIRCUIT CURRENT LIMITER MEMORY EXPANSION Fiber Optic Cable Adapter Auxiliary Trunk
106455348 106455363 105466395 105691158 106590953
see see see TN2400 TN2400 TN2400 & & & TN2401 TN2401 TN2401 G1,G3i,G3 n/a n/a n/a r G1,G3i,G3 n/a n/a n/a r G1.1, 3 3 3 G3r,G3i G1.1 1 1 1 G3r,G3i G3i V2,3,4 4 3 3 1 6 1 5 1 n/a, Intl.
short wavelength, up to 4900 ft. Requires 9823A on both ends short wavelength, up to 25,000 ft. Requires 9823B on both ends G3r PPN requires CFY1B G3r PPN requires CFY1B
107933350 R7.1 CSI 103280350 G3V2
TN420C
TONE DETECTOR(A-law)
106387640 G3V2-4
3
2
n/a
TN429 TN429B
LS-DIOD Trunk, (Japan) LS-DIOD Trunk, (Japan)
103280475 G3V2 107793770 G3V2
4 Upgrade to TN429C 1 10
4 1
n/a, Intl. n/a, Intl.
replaced by TN763D (cc 106405616). This code is not supported in G650. This circuit pack is not supported in CM5.x and later. Definity One requires TN744D minimum. This code is not supported in G650. This circuit pack is not supported in CM5.x and later. This circuit pack is not supported in CM5.x and later. This circuit pack is not supported in CM5.x and later.
TN429C TN429D
Japan DIOD/CAMA CO Trunk (DIOD/CAMA/ICLID)
108032947 R6.1 108032954, R6.3 RoHS 700394547
1 1
n/a 1
This circuit pack is not supported in CM6.x and later. TN429D v1 is not acceptable in Japan and does not support ICLID or CAMA. V2 and above supports ICLID, CAMA and Japan.
SYSTEM 75/DEFINITY G 1.1, G3, R5, R6, R7, R8, R9, SYSTEM 75/DEFINITY® G 1.1, G3, R5, R6, R7, R8, R9, R10.1, IP600 Definity One® R1, R2, R3, MultiVantage™, and Avaya™ Communication Manager CARRIER AND CABINET LEVEL CIRCUIT MODULES
Apparatus code
Description
COMCODE RELEASE (non-GSA) VERSION
(see Note 2 on the cover page)
CERTIFIA CHANGE NOTICE MIN. MIN. BLE STOCK USABLE VINTAGE VINTAG VINTAGE E
Warning
Comments/ Old Change Notices
TN433
Voice Synthesizer (Italy)
103280517 G3V2
1
1
TN436
DID Trunk (Australia, current source) DID Trunk (Australia, current source) Tie Trunk (4w E&M)
103280541 G3V2
4
3
n/a, Internati onal n/a, Intl.
This circuit pack is not supported in CM6.x and later.
This circuit pack has not been tested with CM6.x and is not guaranteed to function with CM6.x and later. This circuit pack has not been tested with CM6.x and is not guaranteed to function with CM6.x and later. Replaced by TN760E. This code is not supported in G650. This circuit pack is not supported in CM6.x and later. Replaced by TN760E. This code is not supported in G650. This circuit pack is not supported in CM6.x and later. This circuit pack has not been tested with CM6.x and is not guaranteed to function with CM6.x and later. This circuit pack has not been tested with CM6.x and is not guaranteed to function with CM6.x and later. This circuit pack has not been tested with CM6.x and is not guaranteed to function with CM6.x and later. This code is not supported in G650. This circuit pack is not replaced by TN2147 (cc supported in CM6.x and later. 106008410) This code is not supported in G650. This circuit pack is not supported in CM5.x and later. This circuit pack is not supported in CM6.x and later.
TN436B
106483357 G3V2
1
1
n/a, Intl.
TN437
103280558 G3V2
DA
n/a, Intl.
TN437B
Tie Trunk (4w E&M)
106503493 G3V2
1
1
n/a, Intl.
TN438
Analog LS CO Trunk
103280566 G3V2
2, DA
2
n/a, Intl.
TN438B
Analog LS CO Trunk (12 & 16 kHz PPM) Tie Trunk (2-w, Japan)
Tie Trunk (4w E&M, UK) DID TRUNK (UK current source)
5, DA 1
4 1
n/a, Intl. n/a, Intl.
This code is not supported in G650. This circuit pack is not replaced by TN760E supported in CM6.x and later. This circuit pack is not supported in CM6.x and later.
BASIC ICSU requires TN464E (cc 106863038) ENHANCED ICSU requires TN464F (cc 107214702). This code does not provide Echo Cancellation. Consequently, this code should not be used in an IP connected system. Use TN464GP or later. BASIC ICSU requires TN464E (cc 106863038) ENHANCED ICSU requires TN464F (cc 107214702). This code does not provide Echo Cancellation. Consequently, this code should not be used in an IP connected system. Use TN464GP or later. ENHANCED ICSU requires TN464F (cc 107214702). DS1 LINE SIDE requires V5. This code does not provide Echo Cancellation. Consequently, this code should not be used in an IP connected system. Use TN464GP or later. V15 required for Russia, Czech Republic, and Slovakia. TN464GP is required for echo cancellation. This code does not provide Echo Cancellation. Consequently, this code should not be used in an IP connected system. Use TN464GP or later.
TN464D
DS1 INTERFACE (24/32)
2
1
n/a
TN464E
DS1 INTERFACE (24/32)
Change to TN464F
5
n/a
TN464F
DS1 INTERFACE (24/32)
31
3
n/a
TN464GP DS1 INTERFACE (24/32) with Echo Cancellation
SYSTEM 75/DEFINITY G 1.1, G3, R5, R6, R7, R8, R9, SYSTEM 75/DEFINITY® G 1.1, G3, R5, R6, R7, R8, R9, R10.1, IP600 Definity One® R1, R2, R3, MultiVantage™, and Avaya™ Communication Manager CARRIER AND CABINET LEVEL CIRCUIT MODULES
Apparatus code
Description
COMCODE RELEASE (non-GSA) VERSION
(see Note 2 on the cover page)
CERTIFIA CHANGE NOTICE MIN. MIN. BLE STOCK USABLE VINTAGE VINTAG VINTAGE E
Warning
Comments/ Old Change Notices Echo Cancellation requires R9.1 or greater. Note: The echo cancellation plans for TN464HP are not the same as for TN464GP. See Communicatio n Manager 3.0 or greater documentation for more details.
TN464HP DS1 INTERFACE (24/32) with Echo Cancellation
700350259, R9.1 RoHS 700394794, (700466014)
VH5F24 VH1F18 VH1F18
TN465B
CO TRUNK
106882400 G3
1
1
1
TN465C
CO TRUNK
TN467
Analog Line (ONS/OPS)
106989429, G3 RoHS 700394513 103280756 G3
2
1
1
TN465C v2 (cc 106989429) and R6.3.1 are required for Brazil 900 ohm functionality. This circuit pack has not been tested with CM6.x and is not guaranteed to function with CM6.x and later. TN465C v2 (cc 106989429) and R6.3.1 are required for Brazil 900 ohm functionality. Replaced by TN793CP . This code is not supported in G650. This circuit pack is not supported in CM6.x and later. Replaced by TN793CP . This code is not supported in G650. This circuit pack is not supported in CM6.x and later. This code is not supported in G650. This circuit pack is not supported in CM6.x and later. This code is not supported in G650. This circuit pack is not supported in CM6.x and later.
3
2
n/a Intl.
TN468B
ANALOG LINE (ONS, UK & Australia) Analog Line (Japan ring cadence) Tie Trunk (Italy 2-w TGE/TGI/TGU) PACKET DATA LINE
SYSTEM 75/DEFINITY G 1.1, G3, R5, R6, R7, R8, R9, SYSTEM 75/DEFINITY® G 1.1, G3, R5, R6, R7, R8, R9, R10.1, IP600 Definity One® R1, R2, R3, MultiVantage™, and Avaya™ Communication Manager CARRIER AND CABINET LEVEL CIRCUIT MODULES
Apparatus code
Description
COMCODE RELEASE (non-GSA) VERSION
(see Note 2 on the cover page)
CERTIFIA CHANGE NOTICE MIN. MIN. BLE STOCK USABLE VINTAGE VINTAG VINTAGE E
Warning
Comments/ Old Change Notices
TN556
ISDN BRI(4W-S/T-NT) LINE
103281648 G3r,G3i,G 3s
6
6
6
TN556C (cc 108187188) or greater required for R6csi BRI line. This circuit pack has not been tested with CM6.x and is not guaranteed to function with CM6.x and later. TN556C (cc 108187188) or greater required for R6csi BRI line. This circuit pack has not been tested with CM6.x and is not guaranteed to function with CM6.x and later.
108187188 R6.2 108267097, R6.2 RoHS 700394570 103281747 E
3 1
2 1
2 1
TN566
TN566B
Multi-Function Board
107083651 E
Change to TN566B v2 2
1
1
Not Supported by Definity One. This code is not supported in G650. This circuit pack is not supported in CM3.x and later. Not Supported by Definity One. This code is not supported in G650. This circuit pack is not supported in CM3.x and later. Not Supported by Definity One. This circuit pack is not supported in CM6.x and later. Not Supported by Definity One. This circuit pack is not supported in CM3.x and later.
This circuit pack is not supported in CM6.x and later. S87x0, S8500 systems require TN570B V7 or greater. TN570Ds are only required in port networks that are enabled to use the Enterprise Survivable Server (ESS) feature AND are equipped with both TN570 and TN2312AP/BP. TN570D is recommended for S87x0 Server separation. BRI, WIDEBAND, and ASAI require V9. "Sleeping digital lines" require V10. In R5 and greater, TN570B v5 is required with TN1654. TN570C is required with Survivable Remote EPN & SRP. US Customers that need minimum vintage updates to TN570B V7+ can contact Authentic Avaya at 1-800-9731607.
SYSTEM 75/DEFINITY G 1.1, G3, R5, R6, R7, R8, R9, SYSTEM 75/DEFINITY® G 1.1, G3, R5, R6, R7, R8, R9, R10.1, IP600 Definity One® R1, R2, R3, MultiVantage™, and Avaya™ Communication Manager CARRIER AND CABINET LEVEL CIRCUIT MODULES
Apparatus code
Description
COMCODE RELEASE (non-GSA) VERSION
(see Note 2 on the cover page)
CERTIFIA CHANGE NOTICE MIN. MIN. BLE STOCK USABLE VINTAGE VINTAG VINTAGE E
Warning
Comments/ Old Change Notices
TN570B
EXPANSION INTERFACE
106696081 G3r,G3i
7
7
7
This circuit pack is not supported in CM6.x and later. S87x0, S8500 systems require TN570B V7 or greater. TN570Ds are only required in port networks that are enabled to use the Enterprise Survivable Server (ESS) feature AND are equipped with both TN570 and TN2312AP/BP. TN570D is recommended for S87x0 Server separation. All other port networks can use TN570B V7 or greater. For systems other than S87x0 and S8500, the minimum usable vintage is V1 with the following exceptions: "Sleeping digital lines" require V2; in R5 and greater, TN570B v5 is required with TN1654; TN570C is required with Survivable Remote EPN & SRP. US Customers that need minimum vintage updates to TN570B V7+ can contact Authentic Avaya at 1-800-9731607. This circuit pack is not supported in CM6.x and later. TN570Ds are only required in port networks that are enabled to use the Enterprise Survivable Server (ESS) feature AND are equipped with both TN570 and TN2312AP/BP. TN570D is recommended for S87x0 Server separation. All other port networks can use TN570B V7 or greater.
TN570C
EXPANSION INTERFACE
108230624 R6.3
5
1
1
TN570D
EXPANSION INTERFACE
108469446 MultiVanta ge
6
4
4 This circuit pack is not supported in CM6.x and later. TN570Ds are only required in port networks that are enabled to use the Enterprise Survivable Server (ESS) feature AND are equipped with both TN570 and TN2312AP/BP. TN570D is recommended for S87x0 Server separation. All other port networks can use TN570B V7 or greater. This circuit pack is not supported in CM6.x and later. TN573B (cc 107737934) is required with TN1654. This circuit pack is not supported in CM6.x and later. This circuit pack is not supported in CM6.x and later. This circuit pack is not supported in CM6.x and later. Replaced by TN1654 (cc 105533756). This code is not supported in G650. The vintages of the two boards used on each span should match. E.G. Span 1 could have V9's on each end and span 2 could have V12's on each end.
CS, CMS and AUDIX Require TN738 (cc 103556916). Cannot be used for OPS service, only CO connect without "D" Channel. This code is not supported in G650. This code does not provide Echo Cancellation. Consequently, this code should not be used in an IP connected system. Use TN464GP or later. Centralized Attendant Service customers require Vintage 6. This code is not supported in G650. This code does not provide Echo Cancellation. Consequently, this code should not be used in an IP connected system. Use TN464GP or later. This circuit pack has not been tested with CM6.x and is not guaranteed to function with CM6.x and later.
TN726B (cc 106447402) is required with TN553 in G3r when used with system ports. This circuit pack has not been tested with CM6.x and is not guaranteed to function with CM6.x and later. This circuit pack has not been tested with CM6.x and is not guaranteed to function with CM6.x and later.
SYSTEM 75/DEFINITY G 1.1, G3, R5, R6, R7, R8, R9, SYSTEM 75/DEFINITY® G 1.1, G3, R5, R6, R7, R8, R9, R10.1, IP600 Definity One® R1, R2, R3, MultiVantage™, and Avaya™ Communication Manager CARRIER AND CABINET LEVEL CIRCUIT MODULES
Apparatus code
Description
COMCODE RELEASE (non-GSA) VERSION
(see Note 2 on the cover page)
CERTIFIA CHANGE NOTICE MIN. MIN. BLE STOCK USABLE VINTAGE VINTAG VINTAGE E
Warning
Comments/ Old Change Notices
TN731
MAINTENANCE
103556841 V1
Change To TN731B 1 2 8 2
1
1
R1V1 Systems may use TN731. Replace TN731 with TN731B V1 (cc 105167241) in all R1V2 and R1V3 Systems. This circuit pack is not supported in CM6.x and later. This circuit pack is not supported in CM6.x and later. This circuit pack is not supported in CM6.x and later. This code is not supported in G650. This circuit pack is not supported in CM6.x and later.
Definity One requires TN744D (cc 107784001) minimum. This code is not supported in G650. This circuit pack is not supported in CM6.x and later. This code is not supported in G650. This circuit pack has not been tested with CM6.x and is not guaranteed to function with CM6.x and later. TN744 v5 is required if the system-parameters customer-options form has "Answer Supervision by Call Classifier?" set to "y" AND the trunk group form has "CDR Reports?" set to "y". ASAI AMD and HOTEL/MOTEL PMS require TN744B (cc 107183246). Telecommuting feature "Call Coverage Off Net" requires TN744C V3 (cc 107390379) or later. Definity One requires TN744D (cc 107784001) This circuit pack has not been tested with CM6.x and is not guaranteed to function with CM6.x and later. Telecommuting feature "Call Coverage Off Net" requires TN744C v3 (cc 107390379) or later. Definity One requires TN744D (cc 107784001) or greater.
TN744B
CALL CLASSIFIER
107183246 G3
2
1
TN744C
CALL CLASSIFIERDETECTOR (with Tone Detection)
107390379 G3 Issue 3.0
Change to TN744E
1
1, Hotel/M otel applicati ons require v2 1,
This circuit pack has not been tested with CM6.x and is not guaranteed to function with CM6.x and later. Telecommuting feature "Call Coverage Off Net" requires v3 or later. Definity One requires TN744D (cc 107784001) or greater.
SYSTEM 75/DEFINITY G 1.1, G3, R5, R6, R7, R8, R9, SYSTEM 75/DEFINITY® G 1.1, G3, R5, R6, R7, R8, R9, R10.1, IP600 Definity One® R1, R2, R3, MultiVantage™, and Avaya™ Communication Manager CARRIER AND CABINET LEVEL CIRCUIT MODULES
Apparatus code
Description
COMCODE RELEASE (non-GSA) VERSION
(see Note 2 on the cover page)
CERTIFIA CHANGE NOTICE MIN. MIN. BLE STOCK USABLE VINTAGE VINTAG VINTAGE E
Warning
Comments/ Old Change Notices
Global CALL CLASSIFIER- 700059645, R9.5 DETECTOR RoHS 700394638 TN744FP Global CALL 700437924 CM5.2.1 CLASSIFIER-DETECTOR TN746 ANALOG LINE 103556999 V2,3 G1.1,G3
TN744E
3
1
1
VH4F2
VH4F2
VH4F2
17
12
12
TN746B
ANALOG LINE
106361421 V2,3 G1.1,G3
9, v12, 13 & 14 not stockable Change to TN747B 12, v2024 not stockable Change to TN748C
2
2
This circuit pack has not been tested with CM6.x and is not guaranteed to function with CM6.x and later. Replace TN746 V11 or earlier with TN746 V12 or greater. TN746B (cc 106361421) V6 and later supports A-law and administrable timers. V6 and later supports A-law and administrable timers. See PSN2102 for TN746B in G650.
This circuit pack has not been tested with CM6.x and is not guaranteed to function with CM6.x and later. CD features require TN747B V1 (cc105167266). A-Law companding requires TN747B V12 or greater.
TN748
TONE DETECTOR
1
1
This circuit pack has not been tested with CM6.x and is not guaranteed to function with CM6.x and later. ACD and OCM require TN748C V5 (cc 103981361) or greater. Definity One requires TN744D (cc 107784001). This code is not supported in G650. This circuit pack has not been tested with CM6.x and is not guaranteed to function with CM6.x and later. ACD and OCM require TN748C V5 (cc 103981361) or greater. Definity One requires TN744D (cc 107784001). This code is not supported in G650. This circuit pack has not been tested with CM6.x and is not guaranteed to function with CM6.x and later. 'ACD and OCM require TN748C V5 or greater. Definity One requires TN744D (cc 107784001). This code is not supported in G650.
SYSTEM 75/DEFINITY G 1.1, G3, R5, R6, R7, R8, R9, SYSTEM 75/DEFINITY® G 1.1, G3, R5, R6, R7, R8, R9, R10.1, IP600 Definity One® R1, R2, R3, MultiVantage™, and Avaya™ Communication Manager CARRIER AND CABINET LEVEL CIRCUIT MODULES
Apparatus code
Description
COMCODE RELEASE (non-GSA) VERSION
(see Note 2 on the cover page)
CERTIFIA CHANGE NOTICE MIN. MIN. BLE STOCK USABLE VINTAGE VINTAG VINTAGE E
Warning
Comments/ Old Change Notices
TN748D
TONE DETECTOR
106502552
G1.1,G3
5
1
1
This circuit pack has not been tested with CM6.x and is not guaranteed to function with CM6.x and later. 'Systems experiencing problems with modem answer tone detection require TN748D v5 or greater. Definity One requires TN744D (cc 107784001). This code is not supported in G650. This circuit pack is not supported in CM6.x and later. Systems with Multiple Announcement boards require TN750C (cc 107089922) except 1st pack in system. Definity One requires TN750C (cc 107089922). S87x0, S8500, S8400 systems cannot use TN750. This circuit pack is not supported in CM6.x and later. 'G3r requires V2. Systems with Multiple Announcement boards require TN750C (cc 107089922) except 1st pack in system. Definity One requires TN750C (cc 107089922). S87x0, S8500, S8400 systems cannot use TN750B. This circuit pack is not supported in CM6.x and later. TN750C is not supported in S87x0, S8500, and S8400 systems since there is no way to back up the announcements. TN2501AP is the supported announcement board for S8xx0 systems. This circuit pack is not supported in CM6.x and later. This code is not supported in G650.
TN750
ANNOUNCEMENT
103557039 V3 G1.1, G3i, G3s,G3vs
4
4
4
TN750B
ANNOUNCEMENT
106439623 V3 G1.1,G3
3
1
1
TN750C
ANNOUNCEMENT
107089922 V3 G1.1,G3
13
7
7
TN752 TN753 TN753B
POWER UNIT DID TRUNK DID TRUNK
TN754 TN754B TN754C TN755 TN755B
DIGITAL LINE DIGITAL LINE DIGITAL LINE POWER UNIT POWER UNIT
This circuit pack is not supported in CM6.x and later. XE, CSCC & SCC Only. TN756 may only be used in Standard Reliability G3vs,s,si,i systems without MCCs, EPNs or DS1s. Definity One requires TN744D (cc 107784001). This code is not supported in G650. This circuit pack is not supported in CM6.x and later. This code is not supported in G650. XE ONLY. This circuit pack has not been tested with CM6.x and is not guaranteed to function with CM6.x and later. Customers having end-to-end signaling problems must use TN760B (cc 103975645). Customers using CAS must upgrade to TN760B V6 (cc 103975645). This circuit pack has not been tested with CM6.x and is not guaranteed to function with CM6.x and later. 'Change TN760B (cc 103975645) to Vintage 6 for Systems with CAS feature.
2 4 This circuit pack is not supported in CM6.x and later. Change TN762 to TN762B (cc 103976171) for customers with 7300 Series Hybrid Sets or complaints of dropped incoming calls. This code is not supported in G650.
TN762B TN763
HYBRID LINE AUX TRUNK
103976171 V1,2,3 G1.1,G3 103557161 V1,2,3 G1.1,G3
4 Change To TN763B 1
3 4
3 4
TN763B
AUX TRUNK
105159396 V1,2,3 G1.1,G3
1
1
This circuit pack is not supported in CM6.x and later. This code is not supported in G650. This circuit pack has not been tested with CM6.x and is not guaranteed to function with CM6.x and later. "AUDICHRON" announcement machines require TN763B V1 (cc 105159396). This circuit pack has not been tested with CM6.x and is not guaranteed to function with CM6.x and later.
This code does not provide Echo Cancellation. Consequently, this code should not be used in an IP connected system. Use TN464GP or later. This circuit pack has not been tested with CM6.x and is not guaranteed to function with CM6.x and later. BASIC ICSU requires TN767D (cc 106951924). DS1 LINE SIDE requires TN767D V5. ENHANCED ICSU requires TN767E (cc 107214710). S87x0, S8500, S8400 systems do not support "D" channels on this board. This code is not supported in G650. This code does not provide Echo Cancellation. Consequently, this code should not be used in an IP connected system. Use TN464GP or later. This circuit pack has not been tested with CM6.x and is not guaranteed to function with CM6.x and later. BASIC ICSU requires TN767D (cc 106951924). DS1 LINE SIDE requires TN767D V5. ENHANCED ICSU requires TN767E (cc 107214710). S87x0, S8500, S8400 systems do not support "D" channels on this board. This code is not supported in G650.
SYSTEM 75/DEFINITY G 1.1, G3, R5, R6, R7, R8, R9, SYSTEM 75/DEFINITY® G 1.1, G3, R5, R6, R7, R8, R9, R10.1, IP600 Definity One® R1, R2, R3, MultiVantage™, and Avaya™ Communication Manager CARRIER AND CABINET LEVEL CIRCUIT MODULES
Apparatus code
Description
COMCODE RELEASE (non-GSA) VERSION
(see Note 2 on the cover page)
CERTIFIA CHANGE NOTICE MIN. MIN. BLE STOCK USABLE VINTAGE VINTAG VINTAGE E
Warning
Comments/ Old Change Notices
TN767C
DS1 INTERFACE (24)
106812100 G1.1,G3
3
3
3
This code does not provide Echo Cancellation. Consequently, this code should not be used in an IP connected system. Use TN464GP or later. This circuit pack has not been tested with CM6.x and is not guaranteed to function with CM6.x and later. BASIC ICSU requires TN767D (cc 106951924). DS1 LINE SIDE requires TN767D V5. ENHANCED ICSU requires TN767E (cc 107214710). S87x0, S8500, S8400 systems do not support "D" channels on this board. This code is not supported in G650. This code does not provide Echo Cancellation. Consequently, this code should not be used in an IP connected system. Use TN464GP or later. This circuit pack has not been tested with CM6.x and is not guaranteed to function with CM6.x and later. DS1 LINE SIDE requires TN767D V5. ENHANCED ICSU requires TN767E (cc 107214710). S87x0, S8500, S8400 systems do not support "D" channels on this board. This code is not supported in G650. This code does not provide Echo Cancellation. Consequently, this code should not be used in an IP connected system. Use TN464GP or later. S87x0, S8500, S8400 systems do not support "D" channels on this board. This code is not supported in G650. This circuit pack is not supported in CM6.x and later. 'Definity One requires TN744D (cc 107784001). This code is not supported in G650. This circuit pack is not supported in CM6.x and later. This code is not supported in G650. Replaced by TN793CP. G3i requires V3 in second position. This circuit pack is not supported in CM6.x and later. Lite functionality for services troubleshooting requires TN771D (cc 106689516) for G3i and G3r. Not recommended for Definity ONE. Avaya S87x0, S8500 Media Server with G600, G650, SCC1, and/or MCC1 Media Gateway(s) require TN771D or TN771DP
This circuit pack is not supported in CM6.x and later. TN775B (not vintage 4) (cc 106647985) is required for G3r, S87x0, S8500 EPNs. TN775C (cc 108187170) required in the Survivable Remote EPN. TN2312xP based EPNs require TN775D. This code is not supported in G650. This circuit pack is not supported in CM6.x and later. Do not use v4 in MCC EPNs. TN775C (cc 108187170) required in the Survivable Remote EPN. TN2312xP based EPNs require TN775D. This code is not supported in G650. This circuit pack is not supported in CM6.x and later. TN2312xP based EPNs require TN775D. This code is not supported in G650. This code is not supported in G650. This circuit pack is not supported in CM6.x and later. "Sleeping digital lines" require V26. In R5si and later use v27 or TN570B (cc 106696081). Recommend replacing with TN570B to support future applications. This code is not supported in G650. TN777 is for use in G3i-286 (Tape) systems only. "Sleeping digital lines" require V6. High & Critical Reliability requires V17. "Sleeping digital lines" require V19.
SYSTEM 75/DEFINITY G 1.1, G3, R5, R6, R7, R8, R9, SYSTEM 75/DEFINITY® G 1.1, G3, R5, R6, R7, R8, R9, R10.1, IP600 Definity One® R1, R2, R3, MultiVantage™, and Avaya™ Communication Manager CARRIER AND CABINET LEVEL CIRCUIT MODULES
Apparatus code
Description
COMCODE RELEASE (non-GSA) VERSION
(see Note 2 on the cover page)
CERTIFIA CHANGE NOTICE MIN. MIN. BLE STOCK USABLE VINTAGE VINTAG VINTAGE E
Warning
Comments/ Old Change Notices
TN780
TONE-CLOCK
103557336 G3
7
3
3
This circuit pack is not supported in CM6.x and later. Non-US. requires v4. Definity One requires TN744D (cc 107784001). This code is not supported in G650.
TN786B
PROCESSOR
106718521 G3iV2,3 G3s,G3vs
5
4
TN787F
MULTIMEDIA INTERFACE 107764557 R5
TN787G
MULTIMEDIA INTERFACE 107895971 R5
TN787H
MULTIMEDIA INTERFACE 108011800 R5
TN787J
MULTIMEDIA INTERFACE 108118985 R6
TN787K TN788B TN789 TN789B TN790
MULTIMEDIA INTERFACE 108187642 R6 VOICE CONDITIONER Radio Controller Radio Controller PROCESSOR 107526493 R5 103557427 G3V4 108472796 G3V4 103557435 R5
upgrade to TN787K upgrade to TN787K upgrade to TN787K upgrade to TN787K 10 2 12 2 12
5
4, v10 not certifiabl e 5
This circuit pack is not supported in CM6.x and later. This code is not supported in G650. This circuit pack is not supported in CM6.x and later. This code is not supported in G650. This circuit pack is not supported in CM6.x and later. This code is not supported in G650. This circuit pack is not supported in CM6.x and later. This code is not supported in G650. This circuit pack is not supported in CM6.x and later. This code is not supported in G650. This circuit pack is not supported in CM6.x and later. This code is not supported in G650. This circuit pack has not been tested with CM6.x and is not guaranteed to function with CM6.x and later. This circuit pack has not been tested with CM6.x and is not guaranteed to function with CM6.x and later. V12 has 16 Mb of DRAM and is required for R6 & later software. TN790B (cc 108162280) is required for R7si and R8si. TN2404 is required for R9si and greater. Do not mix TN790 and TN790B in a duplicated system TN2404 is required for R9si and greater. V2 is the minimum usable vintage For R7 and R8 systems. V9 is the minimum usable vintage for R9 and R10 systems. For all systems, the vintage of the TN792's should match.
6
6
7
7
2
2
2 1 11 2 5
2 1 11 2 5
TN790B TN791 TN792
PROCESSOR Analog Line Duplication Interface
108162280 R7.1 si 103557443 G3V4? 103557450 R7.1si
VH6F10 VH4F5 (vintage s VH7VH14 are not stockabl e) 14 10 5 3
VH4F5
Complex impedance functionality (for use in countries that use TN2215) requires MultiVantage 1.2 or later. This pack does not support 50Hz balanced ringing (used primarily in France).
10 3
TN798B TN799
PROCESSOR C-LAN
108186255 R6csi 103557526 R7.1
1 1 1 4 4 4 Replaced Replace Replace by d by d by TN798B TN798B TN798B 7 1 1 Upgrade to 4 4
TN799C
This is an INVALID board, replace with TN798B (cc 108186255). CSI ONLY. R9 and greater CSI requires TN2402. CSI ONLY. R9 and greater CSI requires TN2402. This circuit pack is not supported in CM6.x and later. Firmware Download requires TN799C and R9. Avaya S87x0, S8500 Media Server with G600, SCC1, MCC1 Media Gateway(s) require TN799DP H0F5. Use of IP Phone firmware R2.3 and greater requires TN799C V3 or greater. This circuit pack is not supported in CM6.x and later. IP Solutions (DOLAN) traffic should use a dedicated (to DOLAN only) TN799B or greater. Firmware Download requires TN799C and R9. Avaya S87x0, S8500 Media Server with G600, SCC1, MCC1 Media Gateway(s) require TN799DP H0F5. Use of IP Phone firmware R2.3 and greater requires TN799C V3 or greater. This circuit pack is not supported in CM6.x and later. IP Solutions (DOLAN) traffic should use a dedicated (to DOLAN only) TN799C. Avaya S87x0, S8500 Media Server with G600, G650, SCC1, MCC1 Media Gateway(s) require TN799DP H0F5 minimum (F10+ is recommended). Use of IP Phone firmware R2.3 and greater requires TN799C V3 or greater.
SYSTEM 75/DEFINITY G 1.1, G3, R5, R6, R7, R8, R9, SYSTEM 75/DEFINITY® G 1.1, G3, R5, R6, R7, R8, R9, R10.1, IP600 Definity One® R1, R2, R3, MultiVantage™, and Avaya™ Communication Manager CARRIER AND CABINET LEVEL CIRCUIT MODULES
Apparatus code
Description
COMCODE RELEASE (non-GSA) VERSION
(see Note 2 on the cover page)
CERTIFIA CHANGE NOTICE MIN. MIN. BLE STOCK USABLE VINTAGE VINTAG VINTAGE E
Warning
Comments/ Old Change Notices
TN799DP C-LAN
700055015, R10.1 RoHS 700394612, (700463458)
H1F37
H0F1
H0F9
Avaya S87x0, S8500 Media Server with G600, G650 SCC1, MCC1 Media Gateway(s) require TN799DP H0F5 minimum. The latest C-LAN firmware is highly recommended for all platforms and is available from support.avaya.com. 100Mbps
LAN operation in older SCC and MCC cabinets require the non-twisted-pair backplane to connector panel I/O cable to be changed to a twisted pair I/O cable (comcode 700234032). The twisted pair cable only needs to be replaced on the 100Mbps slot. IP600, G600, G650, CMC, and the following SCC and MCC cabinets DO NOT require any modification for 100Mbps operation: J58890H-2 L31 or L32 SCC Port Cabinet; J58890L-2 L28 or L32 SCC SI Control Cabinet; J58890M-2 L18 SCC SI Duplication Control Cabinet; J58890N-2 L17 SCC Expansion Control Cabinet; J58890AF-2 L13 MCC Control Carrier; J58890AH-2 L14 MCC SI Control Carrier; J58890AJ-2 L13 MCC SI Dup Control Carrier; J58890BB-4 L14 MCC Port Carrier
TN801 TN801B TN802 TN802B
MAPD LAN Gateway/CallVisor MAPD LAN Gateway/CallVisor MAPD (for IP Trunk) MAPD (for DOLAN)
This circuit pack is not supported in CM5.x and later. This circuit pack is not supported in CM5.x and later. This circuit pack is not supported in CM5.x and later. This circuit pack is not supported in CM5.x and later.
IP Functionality requires R7.1, Dolan requires R8.2. H1F2 = Hardware vintage 1, Firmware vintage 2
SYSTEM ACCESSMAINTENANCE TN1648B SYSTEM ACCESSMAINTENANCE TN1650B MEMORY (32MB)
TN1648
105533699 G3r 108183310 R6 106495120 G3r
5 3 1, v3 is not stockable 9
5 3 1
5 3 1
Minimum usable vintage for R9 and earlier systems is V4.
TN1654
DS1 CONVERTER
105533756 G3r R5
3
3
This circuit pack is not supported in CM6.x and later.
SYSTEM 75/DEFINITY G 1.1, G3, R5, R6, R7, R8, R9, SYSTEM 75/DEFINITY® G 1.1, G3, R5, R6, R7, R8, R9, R10.1, IP600 Definity One® R1, R2, R3, MultiVantage™, and Avaya™ Communication Manager CARRIER AND CABINET LEVEL CIRCUIT MODULES
Apparatus code
Description
COMCODE RELEASE (non-GSA) VERSION
(see Note 2 on the cover page)
CERTIFIA CHANGE NOTICE MIN. MIN. BLE STOCK USABLE VINTAGE VINTAG VINTAGE E
Warning
Comments/ Old Change Notices
TN1655 TN1656
PACKET INTERFACE TAPE DRIVE
105533764 G3r 105533772 G3r
11 5
4 2
4 Not certifiabl e. Use TN2211 9
In duplicated systems do not pair v7 & earlier with v9 & later.
TN1657
DISK DRIVE
105533780 G3r
9
9
More than 22 PNs requires min. V4. Minimum usable for G3V4 and earlier is V3. Minimum usable for R5 - R8 is V4. This circuit pack is not supported in CM6.x and later. This code is not supported in G650. Replaced by TN793CP. This circuit pack is not supported in CM6.x and later. Replaced by TN2181 (cc 106706948). This code is not supported in G650. This circuit pack is not supported in CM6.x and later. This code is not supported in G650. This circuit pack is not supported in CM6.x and later. This code is not supported in G650. This circuit pack is not supported in CM6.x and later.
TN2135
ANALOG LINE
106008295 G3V2-4
3
3
3
TN2136
DIGITAL LINE(2W)
106008303 G3
3
3
3
TN2138 TN2139 TN2140
CO TRUNK (Loop Start) DID TRUNK TIE TRUNK
106008329
G3
1 1 Change to TN2140B 6 1
1 1 1
1 1 1
106008337 G3 106008345 G3V2-4
TN2140B TIE TRUNK TN2144 ANALOG LINE
107182081 G3V2-4 106008386 G3V2-4
2 1
2 1
This circuit pack is not supported in CM6.x and later. This circuit pack is not supported in CM6.x and later. This code is not supported in G650. Replaced by TN793CP. This circuit pack is not supported in CM6.x and later. This code is not supported in G650. This circuit pack has not been tested with CM6.x and is not guaranteed to function with CM6.x and later.
TN2146 TN2147
DID TRUNK CO TRUNK
106008402 G3V2-4 106008410 G3V2-4
2 2
2 2
2 2
TN2147C CO TRUNK
TN2149
ANALOG LINE
107028623, G3V2-4 RoHS 700393416 106008444 G3V2-4
1
1
1
1
1
1
This circuit pack is not supported in CM6.x and later. This code is not supported in G650. Replaced by TN793CP.
SYSTEM 75/DEFINITY G 1.1, G3, R5, R6, R7, R8, R9, SYSTEM 75/DEFINITY® G 1.1, G3, R5, R6, R7, R8, R9, R10.1, IP600 Definity One® R1, R2, R3, MultiVantage™, and Avaya™ Communication Manager CARRIER AND CABINET LEVEL CIRCUIT MODULES
Apparatus code
Description
COMCODE RELEASE (non-GSA) VERSION
(see Note 2 on the cover page)
CERTIFIA CHANGE NOTICE MIN. MIN. BLE STOCK USABLE VINTAGE VINTAG VINTAGE E
Warning
Comments/ Old Change Notices
TN2180
ANALOG LINE
106706930 G3V2-4
1
1
1
This circuit pack is not supported in CM6.x and later. This code is not supported in G650. Replaced by TN793CP. This circuit pack is not supported in CM6.x and later. 'TN2182 v4 or greater is required for use with the "Coverage Off Net" feature. TN780 (cc 103557336) must be used if Stratum 3 is required. This code is not supported in G650. This circuit pack is not supported in CM6.x and later. TN780 (cc 103557336) must be used if Stratum 3 is required. This code is not supported in G650. This circuit pack is not supported in CM6.x and later. TN780 (cc 103557336) must be used if Stratum 3 is required. This code is not supported in G650. V4 or greater is required for Brazil 900 ohm functionality. This circuit pack is not supported in CM6.x and later. This code is not supported in G650.
TN2181 TN2182
DIGITAL LINE (2W DCP) TONE-CLOCK - (with Tone Detection & Call Classifier)
106706948 G3V2-4 106706955 G3V3 Issue 3.0 G3V4
10 Change to TN2182C
2 2
4 4
TN2182B Global TONE-CLOCK (with Tone Detection & Call Classifier) TN2182C Global TONE-CLOCK (with Tone Detection & Call Classifier) TN2183 ANALOG LINE TN2184 DIOD TRUNK
TN2198B ISDN BRI(2W U-LT) LINE P TN2199 CO TRUNK (Russia)
G3V4 G3V3-4
H3F1 7
H1F1 4
H3F1 4 This circuit pack has not been tested with CM6.x and is not guaranteed to function with CM6.x and later. TN2202 can only be used for France (and Macedonia?) systems that have modified backplanes to accept this circuit pack.
SYSTEM 75/DEFINITY G 1.1, G3, R5, R6, R7, R8, R9, SYSTEM 75/DEFINITY® G 1.1, G3, R5, R6, R7, R8, R9, R10.1, IP600 Definity One® R1, R2, R3, MultiVantage™, and Avaya™ Communication Manager CARRIER AND CABINET LEVEL CIRCUIT MODULES
Apparatus code
Description
COMCODE RELEASE (non-GSA) VERSION
(see Note 2 on the cover page)
CERTIFIA CHANGE NOTICE MIN. MIN. BLE STOCK USABLE VINTAGE VINTAG VINTAGE E
Warning
Comments/ Old Change Notices
TN2207
DS1 INTERFACE(24/32)
107245235 R6.2
21
3
3
This code does not provide Echo Cancellation. Consequently, this code should not be used in an IP connected system. Use TN464GP or later. This circuit pack has not been tested with CM6.x and is not guaranteed to function with CM6.x and later. S87x0, S8500, S8400 systems do not support "D" channels on this board. This code is not supported in G650. This circuit pack is not supported in CM6.x and later. This circuit pack has not been tested with CM6.x and is not guaranteed to function with CM6.x and later.
TN2208 TN2209
Multi-Function Board (LanGateway) TIE TRUNK
107533846 E 107759946 G3V4
1 2
1 2
1 2
Optical Drive DIGITAL LINE (2W) 24 ports , TN2214B DIGITAL LINE (2W) 24 ports , TN2214C DIGITAL LINE (2W) 24 P ports ,
TN2211 TN2214
107849754 R8.1 107892630 R6.2 108335605 R6.2
1
6 omit v3 3
1 1 1
4 1 1 TN2214B Vintage 10 through 18 are not recommended with CM6.x and greater. See PSN568 for details. See PSN1418 for VH8 and VH9 unusable serial numbers. Affected VH8 and VH9 units are not certifiable.
H7F15 (see warnin g) 7, v9v13 and v15 are not certifia ble 4
Vintage 9 is not usable! See PSN1380 for TN2215 in G650.
TN2224
DIGITAL LINE (2W) 24 ports
107582728 G3V4 Issue 5+
4, v6 is not stockable
4
TN2224B provides higher data capacity than TN2224. TN2224 users with long display text and high call volumes may experience garbled displays and inconsistent display and telset lamps. TN2224B Vintage 10 through 18 are not recommended with CM6.x and greater. See PSN568 for more details.
This code is not supported in G650. This circuit pack is not supported in CM6.x and later. This circuit pack has not been tested with CM6.x and is not guaranteed to function with CM6.x and later.
TN2301 Survivable Remote TN2302A IP Media Processor P
HV0 through HV9 are not supported in CM6.x and later. FW120 should not be use with EI supported port networks. TN8400 based systems, T.38 Fax and some datamodem features require HV11 minimum. Some CM features require updated firmware. The latest firmware for TN2302AP is recommended and is available from support.avaya.com. Avaya S87x0, S8500, S8400 Media Server with G600, G650, SCC1, and/or MCC1 Media Gateway requires H3F35 minimum. 100Mbps LAN operation in older SCC and MCC cabinets
require the non-twisted-pair backplane to connector panel I/O cable to be changed to a twisted pair I/O cable (comcode 700234032). The twisted pair cable only needs to be replaced on the 100Mbps slot. IP600, G600, G650, CMC, and the following SCC and MCC cabinets DO NOT require any modification for 100Mbps operation: J58890H-2 L31 or L32 SCC Port Cabinet; J58890L-2 L28 or L32 SCC SI Control Cabinet; J58890M-2 L18 SCC SI Duplication Control Cabinet; J58890N-2 L17 SCC Expansion Control Cabinet; J58890AF-2 L13 MCC Control Carrier; J58890AH-2 L14 MCC SI Control Carrier; J58890AJ-2 L13 MCC SI Dup Control Carrier; J58890BB-4 L14 MCC Port Carrier
This circuit pack is not supported in CM6.x and later. Enterprise Survivable Servers (ESS) with ATM PNC require TN2305B or TN2306B This circuit pack is not supported in CM6.x and later. This circuit pack is not supported in CM6.x and later. Enterprise Survivable Servers (ESS) with ATM PNC require TN2305B or TN2306B This circuit pack is not supported in CM6.x and later.
SYSTEM 75/DEFINITY G 1.1, G3, R5, R6, R7, R8, R9, SYSTEM 75/DEFINITY® G 1.1, G3, R5, R6, R7, R8, R9, R10.1, IP600 Definity One® R1, R2, R3, MultiVantage™, and Avaya™ Communication Manager CARRIER AND CABINET LEVEL CIRCUIT MODULES
Apparatus code
Description
COMCODE RELEASE (non-GSA) VERSION
(see Note 2 on the cover page)
CERTIFIA CHANGE NOTICE MIN. MIN. BLE STOCK USABLE VINTAGE VINTAG VINTAGE E
Warning
Comments/ Old Change Notices
TN2308
DID TRUNK (900 Ohm)
108271313 R6.3
2
1
1
This circuit pack has not been tested with CM6.x and is not guaranteed to function with CM6.x and later. TN2312BP is required for G650 operation. Note that S8400/TN8400AP based systems use TN8412AP.
This code does not provide Echo Cancellation. Consequently, this code should not be used in an IP connected system. Use TN464GP or later. S87x0, S8500, and S8400 systems do not support "D" channels on this board. Always used with a TN794 (cc 103557476, assembly cc 848254942).
TN2314 TN2400 TN2401 TN2402 TN2404 TN2464
Definity ONE Processor Net/Pkt BP Conn NetPkt Processor Processor DS1 INTERFACE(24/32) Category B
108549494 R10.1 108305814 R7.1 si 108516675 108516683 108568262 108198946 R9.1 si R9.1 csi R9.1 si R6.3
9 2 5 6 10 32
3 1 3 4 3 18
3 1 3 4 3 18
This code does not provide Echo Cancellation. Consequently, this code should not be used in an IP connected system. Use TN2464BP, TN464GP or later. TN2464BP is required for Echo Cancellation. Echo Cancellation requires R9.1 or greater.
TN2464B DS1 INTERFACE (24/32) P with Echo Cancellation
SYSTEM 75/DEFINITY G 1.1, G3, R5, R6, R7, R8, R9, SYSTEM 75/DEFINITY® G 1.1, G3, R5, R6, R7, R8, R9, R10.1, IP600 Definity One® R1, R2, R3, MultiVantage™, and Avaya™ Communication Manager CARRIER AND CABINET LEVEL CIRCUIT MODULES
Apparatus code
Description
COMCODE RELEASE (non-GSA) VERSION
(see Note 2 on the cover page)
CERTIFIA CHANGE NOTICE MIN. MIN. BLE STOCK USABLE VINTAGE VINTAG VINTAGE E
Warning
Comments/ Old Change Notices Echo Cancellation requires R9.1 or greater. Note: The echo cancellation plans for TN2464CP are not the same as for TN2464BP. See Communicatio n Manager 3.0 or greater documentation for more details.\
TN2464C DS1 INTERFACE (24/32) P with Echo Cancellation
700350291, R9.1 RoHS 700394802
VH1F18 VH1F18 VH1F18
TN2501A ANNOUNCEMENT P
108772583, R9.5 RoHS 700394596, (700463466)
VH1F22
VH1F7 VH1F22 Firmware Vintage 18+ is required for the CM4.0 feature to increase the capacity of the TN2501AP to 1024 announcements. New firmare is available from support.avaya.com. Firmware Vintage 7 is required for all systems to avoid an end of year bug. 100Mbps LAN operation in
older SCC and MCC cabinets require the non-twisted-pair backplane to connector panel I/O cable to be changed to a twisted pair I/O cable (comcode 700234032). The twisted pair cable only needs to be replaced on the 100Mbps slot. IP600, G600, G650, CMC, and the following SCC and MCC cabinets DO NOT require any modification for 100Mbps operation: J58890H-2 L31 or L32 SCC Port Cabinet; J58890L-2 L28 or L32 SCC SI Control Cabinet; J58890M-2 L18 SCC SI Duplication Control Cabinet; J58890N-2 L17 SCC Expansion Control Cabinet; J58890AF-2 L13 MCC Control Carrier; J58890AH-2 L14 MCC SI Control Carrier; J58890AJ2 L13 MCC SI Dup Control Carrier; J58890BB-4 L14 MCC Port Carrier
SYSTEM 75/DEFINITY G 1.1, G3, R5, R6, R7, R8, R9, SYSTEM 75/DEFINITY® G 1.1, G3, R5, R6, R7, R8, R9, R10.1, IP600 Definity One® R1, R2, R3, MultiVantage™, and Avaya™ Communication Manager CARRIER AND CABINET LEVEL CIRCUIT MODULES
Apparatus code
Description
COMCODE RELEASE (non-GSA) VERSION
(see Note 2 on the cover page)
CERTIFIA CHANGE NOTICE MIN. MIN. BLE STOCK USABLE VINTAGE VINTAG VINTAGE E
Warning
Comments/ Old Change Notices
TN2602A MEDIA RESOURCE 320 P
700261928, CM3.0 RoHS 700394687, (700463474)
VH2F58
VH2F9 VH2F58 The latest TN2602AP firmware is recommended for all systems and is available from support.avaya.com. TN2602AP Duplication (supported in CM3.1 and greater) requires FV20 or greater. 100Mbps LAN operation in older SCC and
MCC cabinets require the non-twisted-pair backplane to connector panel I/O cable to be changed to a twisted pair I/O cable (comcode 700234032). The twisted pair cable only needs to be replaced on the 100Mbps slot. IP600, G600, G650, CMC, and the following SCC and MCC cabinets DO NOT require any modification for 100Mbps operation: J58890H-2 L31 or L32 SCC Port Cabinet; J58890L-2 L28 or L32 SCC SI Control Cabinet; J58890M-2 L18 SCC SI Duplication Control Cabinet; J58890N-2 L17 SCC Expansion Control Cabinet; J58890AF-2 L13 MCC Control Carrier; J58890AH-2 L14 MCC SI Control Carrier; J58890AJ-2 L13 MCC SI Dup Control Carrier; J58890BB-4 L14 MCC Port Carrier.
TN2793
ANALOG LINE (24 port)
108057886 R6.3
Upgrade to TN2793B 8 omit 1216
4
4
TN2793B ANALOG LINE (24 port)
108551763 R6.3
2
5
TTI requires V5 or greater
R8.2 or greater required to use caller ID.
TN8400A MEDIA SERVER P TN8400B MEDIA SERVER P TN8412A SERVER IP INTERFACE P DUPLICATION INTERFACE UN331B PROCESSOR UN331C PROCESSOR UN332 MSS/NETWORK CONTROL UN332B MSS/NETWORK CONTROL UN330B
700327604, CM 3.1 RoHS 700394778 700439565 CM 4.0.3 700332430, CM3.1 RoHS 700406499 106495146 G3r 106495138 G3r 108592411 G3r 105262398 G3r
VH1F1
VH1F1
VH1F1
VH1 VH1F20
VH1
VH1 TN8412 is only supported in S8400 systems. The latest SIPI firmware is available from support.avaya.com. Minimum usable vintage for R8 and earlier is V2.
VH1F2 VH1F20
4 11 9 9
3 5 8 6
3 5 8 6
108152935 G3r
upgrade to UN332C
2
2
Sleeping digital lines require V9. Magneto Optical drives (TN2211) requires UN332C. R9 and greater requires UN332C Magneto Optical drives (TN2211) requires UN332C. R9 and greater requires UN332C.
S8300 Media Server and Media Modules
Apparatus Description code
COMCODE RELEASE (non-GSA) VERSION 700221161 MultiVantage
MIN. STOCK VINTAGE
MIN. USABLE VINTAGE
CERTIFIABLE VINTAGE
CHANGE NOTICE
Warning
Comments/ Old Change Notices
MM710
T1/E1 Media Module (Avaya White) T1/E1 Media Module (Avaya Dark Grey)
VH4F*
VH4F*
VH4F*
*Note: The firmware on the board should be updated to the latest vintage available on the support.avaya.com web site. *Note: The firmware on the board should be updated to the latest vintage available on the support.avaya.com web site. *Note: The firmware on the board should be updated to the latest vintage available on the support.avaya.com web site. SLS & ABCD Tones require HV20+. VH5 is required for France (50 Hz balanced ringing). *Note: The firmware on the board should be updated to the latest vintage available on the support.avaya.com web site. SLS & ABCD Tones require HV20+. *Note: The firmware on the board should be updated to the latest vintage available on the support.avaya.com web site. *Note: The firmware on the board should be updated to the latest vintage available on the support.avaya.com web site. *Note: The firmware on the board should be updated to the latest vintage available on the support.avaya.com web site.
MM710
700315567, MultiVantage RoHS 700394737
VH4F*
VH4F*
VH4F*
RoHS - MultiVantag MM710B T1/E1 700439250 e Media (700466634) Module (Avaya Dark Grey) MM711 Analog 700221146 MultiVantage Media Module (Avaya White)
VH10F* Omit VH13
VH10F*
VH10F* Omit VH13
VH5F*
VH4F*
VH4F*
MM711
MM712
MM712
Analog 700315575, MultiVantage Media RoHS Module 700394661, (Avaya Dark (700466626) Grey) DCP Media 700221153 MultiVantage Module (Avaya White) DCP Media 700315583, MultiVantage Module RoHS (Avaya Dark 700394745 Grey)
Analog 700277379, Communication Media RoHS - Manger 2.0 Module (4 700395221 trunk + 4 line, Avaya Dark Grey) RoHS - Communicatio MM714B Analog 700453889 n Manger 5.2 Media (700466618) Module (4 trunk + 4 line, Avaya Dark Grey) MM716 Analog 700302409, Communication Media RoHS - Manger 3.1 Module (24 700394703, port, Avaya (700466642) Dark Grey) MM717 DCP Media 700302433, Communication RoHS - Manger 2.1 Module (24 port, Avaya 700394711 Dark Grey) (700501048) MM720 BRI Media 700221138 MultiVantage Module (Avaya White) MM720 BRI Media 700315591, MultiVantage Module RoHS (Avaya Dark 700394752 Grey) RoHS - Communica MM721 BRI Media 700393762 tion Manger Module 5.2.1 (Avaya Dark Grey) MM722 BRI Media 700277361, Communicati Module - 2 RoHS - on Manager port (Avaya 700395239 Dark Grey) MM714
VH3F*
VH3F*
VH3F*
*Note: The firmware on the board should be updated to the latest vintage available on the support.avaya.com web site.
VH23F*
VH23F*
VH23F*
*Note: The firmware on the board should be updated to the latest vintage available on the support.avaya.com web site.
VH5F*
VH2F*
VH2F*
*Note: The firmware on the board should be updated to the latest vintage available on the support.avaya.com web site. *Note: The firmware on the board should be updated to the latest vintage available on the support.avaya.com web site. *Note: The firmware on the board should be updated to the latest vintage available on the support.avaya.com web site. *Note: The firmware on the board should be updated to the latest vintage available on the support.avaya.com web site. *Note: The firmware on the board should be updated to the latest vintage available on the support.avaya.com web site. *Note: The firmware on the board should be updated to the latest vintage available on the support.avaya.com web site.
COMCODE RELEASE (non-GSA) VERSION 700221179 MultiVantage
MIN. STOCK VINTAGE
MIN. USABLE VINTAGE
CERTIFIABLE VINTAGE
CHANGE NOTICE
Warning
Comments/ Old Change Notices
MM760
S8300
VOIP Media Module (Avaya White) S8300 Media Server (Avaya White) S8300B Media Server (Avaya Dark Grey)
VH1F*
VH1F*
VH1F*
108919994 MultiVantage
V1
V1
V1
*Note: The firmware on the board should be updated to the latest vintage available on the support.avaya.com web site. *Note: The firmware on the board should be updated to the latest vintage available on the support.avaya.com web site. *Note: The firmware on the board should be updated to the latest vintage available on the support.avaya.com web site. *Note: The firmware on the board should be updated to the latest vintage available on the support.avaya.com web site. *Note: The firmware on the board should be updated to the latest vintage available on the support.avaya.com web site.
S8300B
700272412 Communication RoHS - Manger 2.0 700394810
V1
V1
V1
S8300C
S8300C RoHS - Communication Media Server 700407810, Manger 4.0 (Avaya Dark (700466006) Grey) RoHS - Communicatio S8300D 700447675 n Manger 5.2 Media (700463532) Server (Avaya Dark Grey)
Acronym / Meaning Abbreviation ACD ASAI AMD ATM BRI CAMA CAS CMS CO CSCC CSU DC DCP DID DIOD DMI DOLAN DRAM E&M EDC EPN ft. PMS ICLID ICON ICSU ISCN KM LED MAPD MCC MSL OCM ONS OPS PPM PPN PRI QP QPPCN RTU SAT SCC SRP TGE/TGI/TGU Automatic Call Distribution Adjunct Switch Applocation Interface Answering Machine Detection Asynchronous Transfer Mode Basic Rate Interface Centralized Automatic Message Accounting Centralized Attendant Service Call Management System Central Office Compact Single Carrier Cabinet Channel Service Unit Direct Current Digital Communications Protocol Direct Inward Dial Direct Inward and Outward Dialing Digital Multiplexed Interface DEFINITY on Local Area Network Dynamic Random Access Memory "Ear" & "Mouth" European Distribution Center Expansion Port Network Feet Property Management System Incoming Call Line Identification International CONsolodation Integrated Channel Service Unit Information Systems Change Notice (precursor to QPPCN) Kilometer Light Emitting Diode Multi-Application Platform - DEFINITY® Multi-Carrier Cabinet Material Stocking Location Outbound Call Management ON premises Station Off Premises Station Periodic Pulse Metering Processor Port Network Primary Rate Interface see QPPCN Quality Protection Plan Change Notice Right To Use System Access Terminal Single Carrier Cabinet Survivable Remote Processor Traslatore di Giunzione Entrante (Incoming Tie Trunk)/Traslatore di Giunzione Interna (Internal Tie Trunk)/Traslatore di Giunzione Uscente (Outgoing Tie Trunk) - Italian Telecommunications Technology Committee (Japan) Voice Over Iinternet Protocol
TTC VOIP
All trademarks identified by the ® or TM are registered trademarks or trademarks, respectively, of Avaya Inc. All other trademarks are the property of their respective owners.