york air-conditioning products

Chillers & Air Handling Systems

 

On the cover...

This shape’s lines are taken from the ultra-modern building shape of the Montreal Biodome. Building

Efciency provides all heating and air conditioning controls to deliver safe and comfortable conditions for the facility’s different inhabitants - ranging from Antarctic temperatures for the penguins to hot and humid conditions for the tropical plants.

 

york air-conditioning products

A more comfortable,

safe and sustainable world

 

york air-conditioning products

Every building is unique in design and technical requirements. Our customers always receive customised building solutions to meet their individual needs.

Johnson Controls can handle many challenges with its innovative and exible solutions. From A to Z, from consulting to planning, installation, maintenance (service, inspection and repair) and modernisation – Johnson Controls supports customers throughout the entire life cycle of a building.

 

Our well thought-out solutions guarantee a high level of comfort and energy efciency.

External systems can be easily integrated using BACnet® or proprietar proprietaryy solutions.

The majority of our products are already rated as Class A for Energy Efciency, with high levels of compatibility and exibility allowing for future additions to be carried out without difculty.

Our service team is available to you 24 hours a day with one of the largest service networks in Europe.

 

york air-conditioning products

 

york air-conditioning products

Page

Chillers & Heat Pumps YLCA / YLHA Air-cooled scroll compressor chiller / Air-to-water scroll compressor heat pump

12

YLAA Air-cooled scroll compressor chiller

14

YLPA Heat pump scroll compressor YVAA Air-cooled VSD screw chiller

16 18

YCIV Air-cooled VSD screw chiller

20

YSFC Free cooling air-ooled packaged screw compressor chiller

22

CWP Water-cooled cooling only, remote condenser and heat pump scroll compressor chiller

24

YCSE Water-cooled Water-cooled or remote air-cooled screw compressor chiller

25

YCWL Water-cooled Water-cooled or remote air-cooled scroll compressor chiller

26

YLCS Water-cooled Water-cooled or remote air-cooled screw compressor chiller

28

YN Water-cooled screw chiller Dry cooler application - Heat recovery application

30

YR Water-cooled screw compressor chiller

32

YNWS/RS Water-cooled or remote air-cooled screw compressor chiller

34

YNWH Water-cooled screw chiller

35

YMC2 Water-cooled magnetic centrifugal chiller

36

YK Water-cooled centrifugal chiller

38

YIA Single stage hot water or steam powered absorption chiller

40

YPC-ST Two-stage steam fed absorption chiller

42

YPC-F Two-stage direct red chiller-heater

43

Central Plant Optimization™ 10

44

 

Page

Air Handling Systems & Terminal Devices YMA Custom air handling units

48

YMD Modular air handling units

49

®

YORK  Fan Coil units YORK  Close Control units

50 52

SmartPac

54

®

Comprehensivee Building Solutions Comprehensiv Soluti ons Light Commercial Air Conditioning

58

Industrial Refrigeration

60

Metasys® Building Automation and Control Systems

62

 

york air-conditioning products

 

10/11

Chillers & Heat Pumps scroll

compressor chillers and heat

pumps screw compressor air-cooled

&

chillers

water-cooled

centrifugal c ompressor chillers water-cooled absorption central

chillers

plant

water-cooled

optimisation

tm

10

 

york air-conditioning products

YLCA / YLHA Air-cooled scroll compressor chiller Air-to-water scroll compressor heat pump Cooling capacities from 39.6 kW to 151 kW

Features

Options / Accessories

YLCA/YLHA 40 to 80

• Unit without pack • BMS Communication • Remote control • Remote terminal • Water lter (unit without Hydro Pack)

• 2 capacity steps (1 for size 40) • LWT & RWT Control • Hydro Pack standard • Buffer tank integrated • Plate heat exchanger • Condenser ns (blue n) • Pressostatic LAK (-18°C) YLCA/YLHA 100 to 150

• Same features as YLCA/YLHA 40 to 80 • 4 capacity steps • High efciency at full and partial load • Reduced sound levels • 1/4 turn lock for easy access

• Flow switch (unit without Hydro Pack) • Low sound version • Dual pump version • Antivibration mountings • Condenser protection grille

 

12/13

Nominal capacity YLCA / YLHA

Model

Cooling capacity c/o units

kW

EER ESEER

40 T-TP

50 T-TP

60 T-TP

80 T-TP

100 T-TP

120 T-TP

150 T-TP

39.6 3.0

52.1 2. 9 3.24

60.5

77.6

3.1

3.44

2.9 3.26

98 2.9 3.56

119 2. 9 3.80

151 2. 8 3.60

52 52.5 3 / 2. 9 3.14 56 / 50

60.5 59.6 3.1 / 3.0 3.51 57 / 51

7 2. 2 74.7 2.7 / 2.8 3.09 60 / 54

96 104 2.7 / 2.8 3.42 57 / 54

114 119.6 2.6 / 3.0 58 / 54

145 150 2.8 / 2.8 4.18 59 / 55

120 T-TP

150 T-TP

1 190 / 1 286 1 220 / 1 316

226 3 1101 3770 1 415 / 1 503 1 615 / 1 703

3.31

Cooling capacity h/p units Heating capacity h/p units

kW kW

EER / COP ESEER

Sound pressure at 10 m STD / LN

dB ( A )

37.8 38.6

2.8 / 3.0 3.30 54 / 48

3.71

YLCA: Cooling only units models. YLHA: Air to water heat pump models.

Nominal conditions:  

Cooling capacities in kW given for 7°C water leaving temperature ∆t 5°C and 35°C ambient temperature Heating capacities in kW given for 45°C water leaving temperature and 7°C ambient temperature

Technical data YLCA / YLHA

Model

Dimensions

40 T-TP Height W i dt h

Depth Weight without pack / pack c/o Weight without pack / pack h/p

mm mm mm kg kg

1573 1500 822 340 / 380 337 / 39 7

Manufacturer reserves the rights to change specications without prior notice.

50 T-TP

60 T-TP

1600 1011 2104 524 / 580 537 / 593

80 T-TP

100 T-TP

1600

2190 1101 3416

1118

555 / 611 568 / 624

29 4 4 71 5 / 78 5 735 / 805

1 1 24 / 1 2 20 1 154 / 1 250

  s   p   m   u    P    t   a   e    H    &   s   r   e    l    l    i    h    C

 

york air-conditioning products

YLAA Air-cooled scroll compressor chiller Cooling capacities from 177 kW to 521 kW

Features The YORK YLAA TEMPO air-cooled chiller is an environmental leader.

There are 4 versions COOLING ONLY

Utilising scroll type compressors and microchannel condenser coil technology the YLAA delivers premium efciency for all air conditioning applications.

YLAA SE

YLAA chillers are a self-contained cooling solution that is light-weight and compact

YLAA HE LS

YLAA SE LS YLAA HE

Standard Efciency Standard Efciency, Low sound High Efciency High Efciency, Low sound

for convenient installation on the ground or on building rooftops.

The TEMPO delivers energy efciency levels that surpasses Eurovent A Class requirements. Aluminun microchannel microchannel condenser coil technology is one reason for this premium efciencies.

Ultra quiet operation can be obtained through optional dual or low speed fans

and a compressor accousitc enclosure. A single point power connection and optional, factory packaged pumps, water lter and ow switchwater provide fast and easy installation.

An optional heat recovery feature can be added to provide hot water to 50°C; which is useful for facility heating or hot water

Supplies chilled liquid at temperatures between -1°C and 15°C.

preheating.

-18°C to 46°C fully loaded.

Operates in ambient temperatures from

 

14/15

Nominal capacity YLAA SE Standard

180

210

240

285

320

360

Cooling capacity (kW)

196 2.41 3.42 58

218 2.69 3.65 59

276 2.71 4.09

Sound pressure at 10 m (dBA)

1 79 2.84 3.95 57

61

31 0 2.56 3.97 62

344 2.66 3.94 62

YLAA SE LS Standard & Low sound Cooling capacity (kW)

180 177

210

240

285

320

360 336

EER ESEER

2.75

EER ESEER

193 2.30 3.34 50

3.88

21 4 2.63

26 9 2.59 4.01 55

3.67

Sound pressure at 10 m (dBA) (1)

49

YLAA HE High Efciency Cooling capacity (kW)

195

260

300

350

196 3.08 4.39 57

25 3 3.03 4.72

31 0 3.10 4.14

61

61

346 3.10 3.99 62

195

260

300

350

194 2. 9 8 4.26 49

24 8 2.94 4.59 55

30 4 3.01 4.22 54

34 0 3.03 4.01 55

EER ESEER

Sound pressure at 10 m (dBA) YLAA HE LS High Efciency & Low sound Cooling capacity (kW) EER ESEER

Sound pressure at 10 m (dBA) (1)

52

30 1 2.42 3.89 55

400 386

2.55 3.79 62 400

390 386

485

418 2.69 3.92 64

466 2.57

435

374 2.41 3.79 55

2.54 3.96 55

435

408 2.57 3.89 57

3.83

64 485

452 2.43 3.80 57

440

455

515

3.03 4.15

4 29 3.04 4.14

63

63

451 3.07 4.17 64

521 3.06 4.33 64

390 377

440

455

515

4 21 2.96 4.19 56

443 3.01 4.22 57

510 2.96 4.37 57

2.93 4.22 56

At leaving chilled water temperature of 7°C, and ambient temperature of 35°C. (1) Low sound models with acoustically lined compressor compressor enclosure, and xed low speed fans.

Technical data YLAA SE Standard

Dimensions

180 Length Width Height

Operating weight kg

YLAA SE LS Standard & Low sound Dimensions

Length Width Height

180

210

240 2911

285

320

260

Length Width Height

195

Manufacturer reserves the rights to change specications without prior notice.

300

400

435

485

3254

3339

3108

3290

360

400

435

485

3303

3485

36 9 0 2242 2508 2625

2523 350 3690

3449

3534

390

440

455 4807

515

2242 2508 2328

3041

2805

3151

3833

3902

4192

260

300

350 3690

390

440

455 4807

515

3346

4028

4097

4387

2911

mm mm mm

Operating weight kg

2004

2911

2165

YLAA HE LS High Efciency & Low sound Dimensions

2367

1905

360

36 9 0

1848

mm mm mm

Operating weight kg

320

1749

195 Length Width Height

285

1715

1871

YLAA HE High Efciency

240 2911

2242 2508 2469

mm mm mm

Operating weight kg

Dimensions

210

mm mm mm

2242 2508 2321

2484

3236

3000

  s   p   m   u    P    t   a   e    H    &   s   r   e    l    l    i    h    C

 

york air-conditioning products

YLPA Heat pump scroll compressor Cooling capacities from 340 kW to 530 kW Heating capacities from 350 kW to 555 kW At Eurovent Standard Standard Conditions high efciency models meet A Class energy efciency levels.

Features The YLPA heat pump delivers premium energy efciency, it is easy to install, quiet

to run, and it is supported by a knowledgable service force.

Efciency Eurovent A-Class certied full load efciency, high part load efciency, improved defrost cycle, extended operating envelope. Maximize heating efciency and renewable energy use with the YLPA heat pump.

Sound Designed for quiet operation at full and part load conditions. Sustainability European Commission 2020 renewables targets compliant, specically designed for HFC-410A. Ease of installation Quick and easy to install, compact design, Metasys® ready. Reliability The YLPA is our third generation of fully factory tested scroll heat pumps, and thanks to our extensive service solutions, support and minimal maintenance are assured.

 

16/17

Nominal capacity YLPA SE Standard

340

415

495

Cooling capacity (kW)

Heating capacity (kW)

341 2.93 4.0 35 1

4 24 2.90 4.0 4 39

502 2.87 4.0 527

EER

3.11

3.18

57

3.19 57

YLPA HE High Efciency Cooling capacity (kW)

355

425

505

364

443

3.17

3.11

4.3 369 3.28 57

4.4 460 3.21 57

5 29 3.10 4.4 554 3.21 58

415

495

EER ESEER

Sound pressure at 10 m (dBA)

57

EER ESEER

Heating capacity (kW) EER

Sound pressure at 10 m (dBA)

Cooling Capacity at Eurovent Conditions, entering/leaving chilled water temperature 12°C/7°C, ambient temperature 35°C  Heating Capacity at Eurovent Conditions, entering/leaving hot water temperature 40°C/45°C, ambient temperature 7°C  Sound Pressure according to Eurovent conditions. LS models 

Technical data YLPA SE Standard

Dimensions

340 Length

mm

4937

Width Height

mm mm

2265 2502 5000

4600

Operating weight kg

YLPA HE High Efciency Dimensions

Length Width Height

mm mm mm

355

425

505

4 9 37

5854 2265 2502 5400

6971

4750

Operating weight kg

YLPA efciency & annual energy cost Heat Pump efciency (ESEER)

Annual energy cost

4.5

 – €27,500

4.2

25% 25 %

 – €25,000

4.0 14% 14 %

 – €22,500

3.7  – €20,000 3.5  – €17,500

3.2

 – €15,000

3.0 Typical 10-15 year  old Heat Pump

Typical Heat Pump today

5200

YLPA Heat Pump

6100

  s   p   m   u    P    t   a   e    H    &   s   r   e    l    l    i    h    C

Manufacturer reserves the rights to change specications without prior notice.  

york air-conditioning products

YVAA Air-cooled VSD screw chiller Cooling capacities from 525 kW to 950 kW At Eurovent Standard Conditions this equipment meets A Class energy efciency levels.

Features • Reduce your annual energy costs by as much as 30% • Reduce your sound by up to 16 dBA to meet tighter regulations • Minimise your environmental impact dramatically • Improve your peace of mind knowing we stand behind every chiller

  e   d    l   o   n   a   c   l    E   r   e   z   e   t    i    h    t    f   w   o   S  ,    b   e   a   n    l     n    M  a   s    C   u    T   a    L   L   e   e    h   d    t    f   e   o   l   a   y   r   s   é   e   d    t   r    é   u   F   o   e   c   u   q   o   i    t   o   n    h   h    P   c   e    t   y    l   o    P

Reduce refrigerant charges by up to 15% beyond traditional chiller designs with the YV YVAA’s AA’s falling-lm evaporator and microchannel

A more efcient chiller means less electricity generation, which reduces greenhouse gas emissions, water consumption – and your environmental footprint.

condenser coil technology.

® The sustainability advantages of the YVAA chiller give you the opportunity to earn points in the LEED  and BREEAM  building certifcation programs.

®

 

18/19

Application fexibility: 700 kW kW example example YVAA

Cooling capacity (kW) Full Load Efciency (EER) Part Load Efciency (ESEER) Sound pressure at 10 m (dBA)

700 3.2 4.6 69

3.2 4.6

4.4

66

67

2.9 4.2 64

3.1

Cooling Capacity at Eurovent Conditions, entering/leaving chilled water temperature 12°C/7°C, ambient temperature 35°C  Sound Pressure according to Eurovent conditions.

Technical data YVAA Length Width Height

Dimensions

7410

mm mm mm

8540

Operating weight kg

7593

71 78

YVAA YV AA efciency vs. ordinary chiller  YVAA chiller 

 –20

6

7071

7159

YVAA YV AA efciency & annual energy cost

Annual hours %

Ordinary chiller 

EER

7410 2240 2405

Annual energy cost

Chiller efciency (ESEER)

30%  – €50,000

5

 –18  – €45,000

 –16  –14

5

17% 17 %

 –12  –10

 – €40,000

 – €35,000

4

 –8 4

 –6

 – €30,000

 –4  –2 3

 – €25,000

 –0 0

25

50

75

100

3

Chiller load (%)

The YVAA chiller er features the industry’s highest EER at both

 – €20,000 Typical 10-20 year old chiller 

Typical chiller  today

YVAA Chiller 

design and off-design conditions. Note: 3500 operating hours, Energy rate = 0.10 EUR/kWh, Cooling capacity = 850kW

YVAA YV AA sound values vs. ordinary chiller dBA reduction

Annual hours %

0

 –20

-2

 –18

-4

 –16

-6

 –14

-8

 –12

-10

 –10

-12

 –8

-14

 –6

-16

 –4

-18

 –2  –0

-20 0

25

50

75

100

Chiller load (%)

An optimised YVAA chiller can reduce ambient sound by as much as 16 dBA.

The YVAA chiller exceeds typical chiller ESEER in the market today by up to 17% on a new n ew construction project or up to 30% when replacing an older chiller.

Ordinary chiller   YVAA chiller   YVAA optimise optimised d chiller   YVAA optimise optimised d chiller  with attenuation options

  s   p   m   u    P    t   a   e    H    &   s   r   e    l    l    i    h    C

Manufacturer reserves the rights to change specications without prior notice.  

york air-conditioning products

YCIV Air-cooled VSD screw chiller Cooling capacities from 960 kW to 1355 kW Available congurations that meet A Class energy efciency levels at Eurovent Standard Conditions.

Features

Options / Accessories

Super efcient variable speed drive compressors provide high full and part load efciencies. There are four levels of operating efciency: • Standard YCIV with standard capacity control. • Standard YCIV with optimised capacity control. • High efciency YCIV with standard capacity control. • High efciency YCIV with optimised capacity control.

• BAS Interface   Provides means of remotely remotely resetting the leaving chilled liquid temperature. • Condenser coils epoxy post-coated or pre-coated ns. • Copper condenser coil ns. • Wire mesh or louvred protection guards.

Each efciency level has a selection of three acoustic options. • Standard sound level (SE and HE models). • Reduced sound level (RS). • Low sound level (LS). 0.95 Power Factor at all operating conditions c onditions Provides a further reduction in operating costs.

Compressor has 50% less moving parts Having no slide valves, return springs or control solenoids there are 50% less moving parts than a conventional compressor. Soft start Starting current never exceeds full load amps. This eliminates starting stress and reduces the size of any installed standby generator generator.. Chiller will continue to operate Load limiting controls ensure that if maximum operating conditions are exceeded the chiller will continue to operate within safety limits. Plain language 80 character display YCIV has a microprocessor controller with a 80 character plain language display

of temperatures, pressures, motor currents, operating hours, number of starts and start stop/holiday times.

1.00 0.95 0.90

  r   o 0.85    t   c   a    f 0.80   r   e   w 0.75   o    P 0.70

YCIV chiller  0.65

Ordinary A/C screw chiller  0.60

0

10

20

30

40

50

60

Chiller load %

600

500

  s   p   m400   a    d   a   o 300    l      l    l   u 200    F      % 100

Solid State Starter  Star Delta Starter 

YCIV chiller 

0

Time

70

80

90

100

 

20/21

Nominal capacity YCIV SE & YCIV SE RS (standard & reduced sound) Cooling capacity YCIV SE (kW) Cooling capacity YCIV SE RS (kW)

1 070

1180

1 34 0

1 500

959.5 940.1 2.93 2.76 4.01 3.92

1206.5 1192.7 2. 9 6 2. 8 4.05 3.98

1355.1 1340.2 2.96 2.78 4.13 4.01

73

1066 1045.1 2. 9 4 2.76 4.03 3.95 75

76

76

69

71

72

72

YCIV SE LS

1 070

1180

1 34 0

1 500

EER ESEER

940.1 2.77 3.96 60

1045.1 2.77 3.98 60

1192.7 2.78 4.01

1340.2 2.79 4.05

63

63

1050

1120

1220

1380

948.3 938.3 3.09 2.92 4.08 3.98

1009.9 999.8

1099.1 1088.2

EER YCIV SE EER YCIV SE RS ESEER YCIV SE ESEER YCIV SE RS

Sound pressure at 10 m (dBA) YCIV SE Sound pressure at 10 m (dBA) YCIV SE RS (standard & low sound) Cooling capacity (kW)

Sound pressure at 10 m (dBA) (low speed) YCIV HE & YCIV HE RS (high efciency & reduced sound) Cooling capacity YCIV HE (kW) Cooling capacity YCIV HE RS (kW) EER YCIV HE EER YCIV HE RS ESEER YCIV HE ESEER YCIV HE RS

Sound pressure at 10 m (dBA) YCIV HE Sound pressure at 10 m (dBA) YCIV HE RS

71 68

3.11

3.1

2.93 4.08 3.99 72

2.91 4.08 3.98

68

70

1243.6 1229.9 3.09 2. 9 2 4.13 4.05 74 70

73

YCIV HE LS

10 5 0

1120

1220

1380

EER ESEER

938.3 2.93 4.02 59

999.8 2. 9 4 4.03 59

1088.2 2.92 4.02 60

1229.9 2. 9 3 4.08

1 34 0

1 500

10699

11816

(high efciency & low sound) Cooling capacity (kW) Sound pressure at 10 m (dBA) (low speed)

61

Models 1070 to 1500 and 1050 to 1380 built-in b uilt-in 3 refrigerant circuits. Cooling Capacity at Eurovent Conditions, entering/leaving chilled water temperature 12°C/7°C, ambient temperature 35°C  Sound Pressure according to Eurovent conditions.

Technical data YCIV SE & YCIV SE RS (standar & reduced sound) Dimensions

1 070 Length Width Height

1180

9581

mm mm mm

2241 2384

Operating weight kg kg YCIV SE Operating weight kg YCIV SE RS

10437 10957

11077 11597

11577 12097

12014 12534

YCIV SE LS

1 070

1180

1 34 0

1 500

10699

11816

(standar & low sound) Length Width Height Operating weight kg YCIV SE LS

Dimensions

YCIV HE & YCIV HE RS (high efciency & reduced sound) Dimensions

Length Width Height

9581

mm mm mm

mm mm mm

2241 2384 11077

11717

12217

12654

1050

1120

1220

1380

9581

10699 2241 2384

11059

Operating weight kg YCIV HE Operating weight kg YCIV HE RS

10559 11097

10916 11436

11562 12082

11999 12519

YCIV HE LS

10 5 0

1120

1220

1380

(high efciency & low sound) Length Width Height Operating weight kg YCIV HE LS

Dimensions

mm mm mm

9581 11199

10699 2241 2384 11436

11059 12202

12639

  s   p   m   u    P    t   a   e    H    &   s   r   e    l    l    i    h    C

Manufacturer reserves the rights to change specications without prior notice.  

york air-conditioning products

YSFC Free cooling air-cooled packaged screw compressor chiller Cooling capacities from 200 kW to 700 kW

Features

Options / Accessories

The YSFC chiller range has been designed to exploit low winter ambient

• Enhanced Free Cooling performance, • Epoxy Coated Aluminium Fin Ambient Coils. • Single / Dual / Variable Speed Pump alternatives. • BMS Interface Communication Cards, (Modbus, Bacnet.) • Low Sound and Super Low Sound Kits. • Glycol Free Systems • Pressure Regulation / Balancing Valve. • Electronic Expansion Valves.

temperatures for Client’s systems operating with a high base load. By providing temperatures “Free” cooling to the Building or Process, energy savings are maximised to achieve exceptional exceptional full and part load winter efciencies up to an EER 26. The YSFC chiller includes the following additional specialised features: - Two

2-way-cooling mode / Free cooling change over valves, Integrated Free cooling 2-way-cooling with Refrigerant Condenser ambient coil blocks. The YSFC operates in three modes: - (1) (1 ) Mechanical Cooling in Summer (2) Partial

Free Cooling and Mechanical Cooling in Mid Season (3) Free Cooling in Winter.

 

22/23

  s   p   m   u    P    t   a   e    H    &   s   r   e    l    l    i    h    C

Nominal capacity YSFC-SB

0200

0250

0275

0300

0400

0450

0500

0600

0750

0850

1000

1300

1500

1700

Cooling Capacity kW Energy Efciency Ratio (EER) ESEER (Mechanical Cooling) Free-Cooling Performance kW

20 7 2.40 2. 9 1

26 8 2.66 3.25 255

300 2.53 3.08

388

183

244 2.64 3.22 23 7

361

2.63 3.21 352

476 2.69 3.29 439

518 2.65 3.23 466

646 2.69 3.29 560

7 35 2.58 3.15 5 75

846 2.45 2.99 706

1037 2.65 3.23 9 32

1 29 2 2.69 3.29 1120

1470 2.58 3.15 1150

1692 2.45 2. 9 9 1412

Free-Cooling - EER

11.73 78.1

19.75 75.5

21 . 25

22.56

22.00

21.95

19.42

77.3

78.1

78.8

20.54 80.8

22.06 82.5

23.33 82.9

20.54

77.1

23.33 79.9

19.42

76.1

22.06 85.5

Sound Pressure

81.8

83.8

Nominal data please refer to the Product Catalogue for references.

Technical data YSFC-SB Length Width Height

Dimensions

 

mm

 

mm

 

mm

Operating weight

kg

0200

0250

0275

0300

0400

0450

0500

0600

0750

0850

1000

1300

1500

1700

3070 2210 2352 3900

4060 2210 2412 4500

4060 221 0 24 1 2 4600

5060 2210 2412 5300

5060 221 0 2412 5700

6060 221 0 2412 6350

6060 2210 2412 6700

7070 221 0 2472 7800

7570 2210 24 7 2 8200

9070 221 0 2472 9800

12420 221 0 2472 13400

14440 2210 24 7 2 15600

15440 221 0 2472 16400

18440 221 0 2472 19600

Calculation of percentage of energy savings per month

Free Cooling circuit representation

100% 90 %

Líquido enfriado

Moscow Stockholm

80 %

T  C  F    e   o  e  r   m  o  e  �  p l   i   n  .  g 

Warsaw



P  r   e   s   s 

Evaporator F   l      o w

 t    e   O  m  u   t    p  d   e   o r   o  a  r   t    u  r   e 

 t   n   e  I   m  d   o  p  o  e  r  r   a   t    u  r   e 

3 Way

valve

Berlin

70 %

Paris

  p  C  0   3 

Madrid

60 % 50 %

Fan

Fan

Fan

Condenser

40 %

Fan Condenser  

30 % 20 % 10 %

0%

 J    a  n   u   a  r   y 

F    e   b   r    u   a  r     y 

M  a  r    c  h  

A   p r  i   l  

M  a   y 

 J    u  n   e 

 J    u  l    y 

A   u   g   u   s   t  

 S   e   p  t    e  m  b   e  r 

 O   c   t     o  b    e  r  

N   o v   e  m  b    e  r  

Energy Saving The graph shows the annual energy saving using free-cooling technology equipment YSFC with temperatures 24/7.

D   e   c   e  m  b    e  r  

Free

Free

Free

Free

Cooling Battery

Cooling Battery

Cooling Battery

Cooling Battery

Manufacturer reserves the rights to change specications without prior notice.  

york air-conditioning products

CWP Water-cooled cooling only, remote condenser and heat pump scroll compressor compressor chiller Cooling capacities from 7.6 kW to 136.2 kW

Features

Available versions

The YORK CWP water cooled chiller uses high efciency scroll compressor compressor

13 available CWP sizes in three versions:

technology for both air conditioning and heating applications.

1) CWP-CO : Cooling only

The compact design of the CWP makes it ideal for tight locations. This machine is a completely independent and it is designed for indoor use.

2) CWP-RC : Remote condenser 3) CWP-HP : Heat pump

Nominal capacity and technical data CWP-CO

2

Cooling Capacity (kW) Length /Width / Height (m) Operating weight (kg)

7.6

CWP-RC Cooling Capacity (kW) Length /Width / Height (m) Operating weight (kg) CWP-HP

Cooling Capacity (kW) Heat atiing Capac aciity (kW) Length /Width / Height (m) Operating weight (kg)

116 2

7.0 110 2

6.5 9.0 1 28

3

4

9.2 13.3 0.8 / 0.6 / 0.9 120 1 27 3

4

8.5 12.4 0.8 / 0.6 / 0.9 114 119 3

4

7.9 11.5 10.7 10.7 15..7 15 0.8 / 0.6 / 0.9 1 32 139

5

6

7

9

15

18

21

25

16.3

19.7

33.7

40.7

87.7

188

20 5

274

55.8 1.1 / 0.8 / 1.1 29 5

67.6

140

28 0.9 / 0.7 / 0.9 200

306

508

5

6

7

9

15

18

21

25

15.1

18.3

31.4

38.2

87.7

180

194

26 1

55.8 1.1 / 0.8 / 1.1 27 9

67.6

132

26.1 0.9 / 0.7 / 0.9 189

290

471

5

6

7

9

15

18

21

25

30

35

14.2 19.0 19 .0

17.1

29.4 40.1 40.

35.9 49.1 49.

67.6 76.1

87.7

111.9

66.7

106.3

133.7

136.2 164.1

154

207

24.4 33.2 33 .2 0.9 / 0.7 / 0.9 22 0

55.8

23.3 23 .3

22 6

302

1.1 / 0.8 / 1.1 3 24

337

538

1.7 / 0.9 / 1.2 571

604

CWP-CO: At 12/7°C leaving chilled water and 30/35 °C leaving condenser water. CWP-RC (02 to 15): Cooling capacity at 12/7°C leaving chilled water and 47 °C leaving condenser water. CWP-RC (18 to 35): Cooling capacity at 12/7°C leaving chilled water and 45 °C leaving condenser water. CWP-HP (02 to 15): Cooling capacity at 12/7°C leaving chilled water and 40/46 °C leaving condenser water. CWP-HP (18 to 35): Cooling capacity at 12/7°C leaving chilled water and 30/35 °C leaving condenser water. CWP-HP (18 to 35): Heating capacity at 12/7°C leaving chilled water and 40/45 °C leaving condenser water.

30

35

111.9 136.2 1.7 / 0.9 / 1.2 541 574 30

35

111.9 136.2 1.7 / 0.9 / 1.2 497 520

Manufacturer reserves the rights to change specications without prior notice.  

24/25

  s   p   m   u    P    t   a   e    H    &   s   r   e    l    l    i    h    C

YCSE Water-cooled or remote air-cooled screw compressor chiller Cooling capacities from 134 kW to 320 kW

Features

Options / Accessories

Efcient screw compressors Highly efcient the YCSE offers the highest standard of reliability and economical operation utilising twin-screw rotor technology and fully modulating compressor slide valve unloading, together with low inrush current star delta starters. To further improve improve the operating efciency the leaving liquid temperatur temperaturee can be

• Remote control switch unit. • BMS interface. • Compressor circuit breakers. • Evaporator heater. he ater. • Flow switch. • Differential pressure switches. • Suction pressure relief valves. • Anti-vibration rubber mounts. • Water connection anges. • Discharge and/or suction stop valves. • High condenser water temperature and glycol options.

remotely reset.

Quiet operationhas been designed so that there is minimal external gas pulsations The compressor and integral oil separators resulting in very low sound and vibration levels. Small footprint and robust design The compact design is ideally suited for reduced base area locations. Both single and twin circuit designs require a single liquid inlet and oulet connection. The unit frame is manufactured from heavy gauge galvanised steel coated with baked-on powder paint.

Nominal capacity and technical data YCSE-SB Model

40

50

60

80

100

Cooling Capacity (kW)

1 34 4.00

194 3.95

23 2 4.26

68

160 4.00 69

71

71

780

800

875

1000

32 0 4.00 72 1.5 / 1.1 / 1.7 1655

EER

Sound pressure at 1 m (dBA) Length /Width / Height (m) Operating ng weight (kg) At 7°C leaving chilled water and 35°C leaving condenser water.

0.85 / 1.1 / 1.5

Manufacturer reserves the rights to change specications without prior notice.  

york air-conditioning products

YCWL Water-cooled or remote air-cooled scroll compressor chiller Cooling capacities from 188 kW to 580 kW Available congurations that meet A Class energy efciency levels at Eurovent Standard Conditions.

Features

Options

The YCWL series was designed to produce the

• Compressor acoustic blankets • Flow switch or pressure differential switch • Soft starters • Neoprene pads or spring isolators • Dual relief valves kit • Electronic regulators • P.A.C operation water/water up to 50°C • Vibration isolators

greatest cooling capacity with the lowest sound levels. The use of scroll compressors provides optimum efciency at part load, up to an ESEER of 6.92. Its dimensions have been optimized to pass through a doorway 2 m high by 90 cm wide. The YCWL is designed for all air conditioning

applications. It is equipped with two independent cooling circuits and regulated by a micro-processor that optimizes chiller performance. The YCWL is designed for indoor installation

and each YCWL is fully tested before leaving our factories.

 

26/27

  s   p   m   u    P    t   a   e    H    &   s   r   e    l    l    i    h    C

Nominal capacity YCWL-SE

Cooling capacity (kW)

1

EER

Energy class ESEER

Sound Pressure (dB(A)) 2 YCWL-HE

 

Cooling capacity (kW)

240

291

346

395

22 7 4.70

29 0 4.80

331

4.77

369 4.78

B

B

B

B

6.49

6.15 67

6.20 70

6.50

67 200

230

260

301

346

385

425

446

531

610

188

248 5.17

248 5.03

352 5.13

377

410 5.17

410 5.17

5 20 4.98

580 4.93

A 6.87 67

B 6.38 67

A

A

A

B

B

B

6.46 70

6.89

6.92

6.28

6.60

68

71

6.26 69

71

73

EER

5.06

2 20 5.05

Energy class ESEER

A 6.17

A 6.31

Sound Pressure (dB(A)) 2

64

65

1

71

5.17

1 : Cooling capacity at Eurovent conditions, evaporator evaporator entering/leaving temperature 12°C/7°C, condenser entering/leaving temperature 30°C/35°C. 2 : EN 292-1991 Sound pressure is measured 1 meter away from the control panel and 1.5 meters above the oor. Compressor acoustic acoustic blankets tted.

Technical data YCWL-SE

Dimensions

Length Width Height

   

mm

 

mm

Operating weight

Operating weight

 

Length Width Height

 

mm

 

mm

 

mm

kg

240

291

346

395

3191

3200

3153

31 6 5

1822 20 9 8

1819 2130

860 1749 1759

kg

YCWL-HE

Dimensions

mm

200

230

3 20 0

31 34

1638 1771

1895 1948

2101 260

301

3153

346

385

425

3159

3670 911 1972 2707

3146 860 1892 2204

860 1826 1954

1943 2410

2051

Low sound operation

446

531

610

3066

36 7 0 911 1969 3030

2993

High full and part load efciences

Inside a typical car, 50 km/hr, windows closed

   R    E    E    S    E    /    P    O    C

   )    A    (    B    d   e   r   u   s   s   e   r   p    d   n   u   o    S

Normal conversation, 1m away

Cooling capacity (kW) F ul ul l l oa oa d e f f ci ci en en cy cy (C (C OP OP) Cooling capacity (kW)

Pa rt rt lo lo ad ad ef ef ci ci en en cy cy (E (ESE ER ER )

Manufacturer reserves the rights to change specications without prior notice.  

york air-conditioning products

YLCS Water-cooled or remote air-cooled screw compressor chiller Cooling capacities from 342 kW to 1099 kW Available congurations that meet A Class energy efciency levels at Eurovent Standard Conditions.

Features

Options / Accessories

One chiller, many applications Designed to operate with leaving liquid temperatures from -10°C to +15°C.

• Compressor suction shut-off valves. • Companion ange kits. • Multi-point power supply. • Remote leaving liquid temperature offset. • Pressure gauges.

Efcient compressors YLCS is a dual circuit chiller with industrial type semi-hermetic screw compressors. Star delta compressor starters are incorporated to reduce the inrush current. Outstanding chiller control An advanced microprocessor controller with, a 40 character plain language display, controls and monitors temperatures, pressures, operating hours, number of starts and start stop/holiday times.

Fast and easy installation Evaporator water connections can be provided in a vertical or horizontal plain. Electrical power supplies enter from the top for easy drop down wiring.

•• Closed transition star delta starters. Power factor correction capacitors. • Heat pump control. • 90/10 cupro/nickel condenser.

 

28/29

Nominal capacity YLCS SA

350

415

480

530

575

620

Cooling capacity (kW)

Sound pressure at 10 m (dBA)

342 4.2 5.14 93

411 4.3 5.22 93

480 4.3 5.25 93

518 4.3 5.25 95

556 4.3 5.26 95

604 4.3 5.26 95

YLCS SA

670

750

860

980

1120

Cooling capacity (kW)

645 4.8 5.58 95

743 4.8 5.52 95

849 4.9 5.72 101

966 5.0 5.83 101

1099 5.0 5.79 101

350

415

480

530

575

620

3 225

3244

3544

36 0 0

3420

4030

4370

4540

EER ESEER

EER ESEER

Sound pressure at 10 m (dBA) At 7°C leaving chilled water and 35°C leaving condenser water.

Technical data YLCS SA

Dimensions

Length Width Height

mm mm mm

Operating weight kg YLCS SA

Dimensions Operating weight kg

Length

mm

Width Height

mm mm

3274 900 2100 4170

4270

670

750

860

980

1120

3565

3645

38 30

3830

38 30

5010

1290 2148 5620

6090

6610

4510

  s   p   m   u    P    t   a   e    H    &   s   r   e    l    l    i    h    C

Manufacturer reserves the rights to change specications without prior notice.  

york air-conditioning products

YN Water-cooled screw chiller Dry cooler application - Heat reco recovery very application Cooling capacities from 570 kW to 1300 kW At Eurovent Standard Conditions this equipment meets A Class energy efciency levels.

Features High Efciency Screw Compressor The open drive twin rotary screw compressor has been engineered and constructed to meet the exact requirements of the industrial refrigeration market. It utilises state-of-the-art technology to provide the most reliable compressor, with high energy efciency at all operating conditions. Heat Exchangers Shells - The ooded type evaporator and condenser shells are fabricated from rolled carbon steel plates with fusion welded seams. Carbon steel tube sheets, drilled and reamed to accommodate the tubes, are welded to the end of each shell. Intermediate tube supports are fabricated from 12 mm carbon steel plates. Tubes - The copper alloy heat exchanger tubes are externally and internally enhanced to provide optimum performance. Smooth and accurate capacity control Capacity control is achieved by use of a slide valve which provides fully modulating control from 100% to 10% of full load, depending upon the unit selection. The slide valve is actuated by oil pressure controlled by external solenoid valves via the OptiView control centre. Equipped with the optional Solid State Starter, the YN screw chiller starts “softly,” putting less stress on the motor and compressor, extending their life. In addition, the Solid State Starter includes an impressive array of safety controls that protect the chiller against: phase loss, phase reversal, phase imbalance, under-voltage, overvoltage, and over-current

 

30/31

Nominal capacity YN Model

RB RB S2

Cooling Capacity kW

576 5.65 5.88

EER ESEER Class EER

A

RB RD S2 RD RB S2 RD RD S2 RB RB S3 RB RD S3 RD RB S3 RD RD S3 RB RB S4 RB RD S4 RD RB S4 585 585 75 0 751 769 770 970 9 71 999 576 5.72 5.75 5.81 5.42 5.51 5.56 5.66 5.29 5.43 5.46 5.94 5.98 6.03 5.68 5.75 5.82 5.89 5.72 5.82 5.89 A

A

A

A

A

A

A

A

A

A

RD RD S4 SA SA S4 SA SD S4 SD SA S4 SD SD S4 RD RB S5 RD RD S5 SA SA S5 SA SD S5 SD SA S5 SD SD S5 1001 1036 1037 1054 1055 1231 1 23 5 1 28 5 1286 1316 1318 5.6 5.9 6.07 6.01 6.19 5.22 5.39 5.74 5.97 5.89 6.13 5.99 6.26 6.39 6.37 6.51 5.67 5.82 6.1 6.28 6.23 6.42

YN Model

Cooling Capacity kW (1) EER ESEER Class EER

A

A

A

A

A

A

A

A

A

A

A

At 7°C leaving chilled water and 32°C leaving condenser water.

Technical data YN Model

RB RB S2

Length Dimensions Width Height Operating weight kg

mm mm mm

5017

YN Model Length

mm

Width Height Operating weight kg

mm mm

Dimensions

RB RD S2 RD RB S2 RD RD S2 RB RB S3 RB RD S3 RD RB S3 RD RD S3 RB RB S4 RB RD S4 RD RB S4 3580 1549 2400 5127 5157 5267 5097 5207 5237 5347 5476 5586 5616

RD RD S4 SA SA S4 SA SD S4 SD SA S4 SD SD S4 RD RB S5 RD RD S5 SA SA S5 SA SD S5 SD SA S5 SD SD S5 3580 4211 3580 4211 1549 2400 5 7 26

1585 2410

1676

2500 6919

7408

7160

7649

5787

1700 2500 5897

7090

7579

7331

7820

  s   p   m   u    P    t   a   e    H    &   s   r   e    l    l    i    h    C

Manufacturer reserves the rights to change specications without prior notice.  

york air-conditioning products

YR Water-cooled screw compressor chiller Cooling capacities from 730 kW to 1320 kW Available congurations that meet A Class energy efciency levels at Eurovent Standard Conditions.

Features • The YORK YR chiller has been designed to match the exact building load and lift requirements, which means it will always operate at peak efciency when operating at Real World operating conditions. • Equipped with the optional Solid State Starter, the YR screw chiller starts “softly,” putting less stress on the motor and compressor, extending motor life. • The semi-hermetic YR chiller is designed for all air conditioning applications • The twin rotary screw compressor driven YORK YR chiller is completely factory mounted , including: evaporator,, condenser, subcooler, oil separator evaporator sep arator,, compressor, motor, lubrication system, control panel, as well as all interconnecting piping and wiring. • Flooded type evaporator and condenser shells are fabricated from rolled carbon steel plates with fusion welded seams.

 

32/33

Nominal capacity YR compressor code

Evaporator

T0

TA - TD, VB - VD

Leaving

Leaving

Cooling

chilled water

cooling water

capacity

Condenser

 °C

 °C

kW

TA - TD, V B - VD

6

30

Shell codes

730 770 T1

TA - TD, VB - VD, WA - WD

TA - TD, VB - VD, WA - WD

6

30

T2

WA - WD, XB - XD

WA - WD, XB - XD

6

30

859 905 920 1070 1110

T3

WA - WD, XB - XD

WA - WD, XB - XD

6

30

1280 1320

OptiView Panel

  s   p   m   u    P    t   a   e    H    &   s   r   e    l    l    i    h    C

Manufacturer reserves the rights to change specications without prior notice.  

york air-conditioning products

YNWS/RS Water-cooled or remote air-cooled screw compressor chiller Cooling capacities from 470 kW to 1790 kW Available congurations that meet A Class energy efciency levels at Eurovent Standard Conditions.

Features

 

• The YNWS chiller is designed for all air conditioning applications.

• The screw compressor driven YNWS/RS chiller is completely factory mounted, including: direct expansion (DX) evaporator, condenser, subcooler, oil seperator, compressor, motor, lubrication system, control panel, as well as all interconnecting piping and wiring.

• Both the water cooled YNWS and the remote air cooled YNRS  models are designed for chilled water and process applications. • Both models are designed for indoor mechanical room installation. • The YNRS requires a cooling tower or an air-water condensing unit

• R717 Refrigerant

for heat dissipation.

Nominal capacity and technical data DC GC S0 S0 485 3.7/1. 1.44/1. 1.99 4114

EC FC S0

EC GC S0

Cooling Capacity (kW) Length /W /Width / He Height (m) Operating weight (kg)

DC FC SO SO 482 3.7/1.4/ 4/1. 1.99 4114

511 3.7/1.4/ 4/1. 1.99 4114

YNWS Model

FC JC S2

EC HC S3

Cooling Capacity (kW) Length / Wi Width / Height (m) Operating weight (kg)

856 3.7/1.451 51.9 .9 6669

YNWS Model

Cooling Capacity (kW) Length /W /Width / He Height (m) Operating weight (kg)

YNWS Model

515 3.7/1. 1.44/1. 1.99 4974

DC FC S1 5 75 3.7/1.4/ 4/1. 1.99 4150

DC GC S1 5 79 3.7/1. 1.44/1. 1.99 4540

EC JC S3

EC KC S3

FC HC S3

FC JC S3

1012 3.7/1.4/2.0 6010

1015 3.7/1. 1.4/ 4/22.0 6010

1019 3.7/1.4/2.0 6010

1084 3.7/1. 1.4/ 4/22.0 6010

GC KC S4

GC LC S4

GC MC S4

GC NC S4

1475 3.9 .9//1. 1.66/2.3 8412

1481 3.9/1.6 .6//2.3 8412

1484 3.9 .9//1. 1.66/2.3 8412

1488 3.9 .9//1.8 .8//2.5 10142

At 6°C leaving chilled water and 32°C leaving condenser water.

EC FC S1

EC GC S1

EC GC S2

EC HC S2

EC JC S2

6 31

6 36

3.7/1.4/ 4/1. 1.99 4540

3.7/1. 1.44/1. 1.99 5010

809 3.7/1.4/ 4/1. 1.99 5449

814 3.7/1. 1.44/1. 1.99 5449

848 3.7/1. 1.4/ 4/11.9 5449

FC KC S3

FC KC S4

FC LC S4

FC MC S4

FC NC S4

1088 3.7/1.4/2.0 6010

1093 3.8 .8//1. 1.55/2 .3 .3 7335

1347 3.9/1.6 .6//2.3 8412

1352 3.9 .9//1. 1.66/2.3 8412

1354 3.9/1.6 .6//2.3 8412

1 39 5 3.9/1.6/2.3 8412

FC LC S5

FC MC S5

FC NC S5

GC LC S5

GC MC S5

GC NC S5

1 6 23 3.9 .9//1. 1.77/2.3 9635

1 6 25 3.9 .9//1.7/2 .3 .3 9 6 35

1630 3.9 .9//1. 1.77/2.3 10950

1780 3.9 .9//1.7/2.3 10950

1784 3.9 .9//1. 1.77/2.3 10950

1790 3.9/1. 1.88 /2 /2 .5 .5 10950

Manufacturer reserves the rights to change specications without prior notice.  

34/35

  s   p   m   u    P    t   a   e    H    &   s   r   e    l    l    i

YNWH Water-cooled screw chiller Cooling capacities from 300 kW to 1200 kW Available congurations that meet A Class energy efciency levels at Eurovent Standard Conditions.

   h    C

Features

 

• The YNWH chiller is ideally suited for air conditioning, brine, and industrial applications.

• The screw compressor driven YNWH chiller is completely factory mounted , including: direct expansion (DX) evaporator, evaporator, condenser, subcooler, oil seperator, compressor, motor, lubrication system, control panel, as well as all interconnecting piping and wiring.

• The water cooled YNWH is designed for brine based applications. • This chiller is designed for indoor mechanical room installation.

• R507 refrigerant

• The YNWH requires a cooling tower or an air-water condensing unit for heat dissipation.

Nominal capacity and technical data YNWH Model

16 12 S0

16 12 S1

20 20 S2

20 20 S3

28 24 S4

28 24 S5

Cooling Capacity (kW) Length /Width / Height (m (m) Operating weight (kg)

31 5 3.7/1.5/1.7 3700

380 3.7/1.5/1.7 3900

5 33 3.9/1.6/2.0 6000

683

962 4.3/2.0/2.3 9000

1169 4.4/2.0/2.3 9800

Cooling capacity at -2°/-6°C brine application and 32°C condenser leaving water temperature

3.9/1.6/2.0 6300

Manufacturer reserves the rights to change specications without prior notice.  

york air-conditioning products

2

YMC

Water-cooled magnetic centrifugal chiller Cooling capacities from 755 kW to 1340 kW At Eurovent Standard Conditions this equipment meets A Class energy efciency levels.

Features Our most advanced water-cooled chiller offers the following benets:

Enhanced efciency Achieved through application of active magnetic bearing technology with variable speed drive. Enhanced sustainability Achieved by leak free refrigerant design, lower refrigerant charge

Low sound levels Advanced technology results in sound levels as low as 73dBA. Superior reliability Use of active magnetic bearing technology removes friction and the need for oil resulting in a quieter and more reliable chiller.

and falling lm evaporator.

  e   d    l   o   n   a   c   l    E   r   e   e   z    i    h   t    t    f   w    S   o  ,    b   e   a   n    l     n    M  a    C   s   u    T   a    L   L   e   e    h    t    d    f   e   o   l   y   a   r   s   é   e   d    t   r    é   u   F   o   e   c   u   q   o   i    t   o   n    h   h    P   c   e    t   y    l   o    P

A falling-lm evaporator is more efcient because refrigerant is sprayed over the tubes, offering improved heat transfer and reducing refrigerant charge by 30%.

To eliminate mechanical-contact losses in the driveline, the YMC2 chiller utilises a permanent-magnet permanent-m agnet motor and active magnetic-bearing technology.

 

36/37

Nominal capacity YMC2

S0900AA

S1000AA

S1100AA

S1200AA

S1300AA

900 6.39 8.32

1000 6.44

1100 6.42 9.15

1 20 0 9.40

1300 5.94 9.34

73

73

73

Cooling capacity (kW) EER ESEER

Sound pressure at 1 m (dBA)

73

8.83 73

6.33

   h    C

Cooling Capacity at Eurovent Conditions, entering/leaving chilled water temperature 12°C/7°C, entering/leaving condenser water temperature 30°C/35°C 

Technical data YMC2

S0900AA Length Width Height

Dimensions

S1000AA

S1100AA

S1200AA

S1300AA

5800 280

4267 1651 2362 5810 280

5810 390

6800 390

mm mm mm

Shipping weight (kg) Refrigerant charge (kg)

5340 25 5

NOTES:

1. All dimensions are approximate. Certied dimensions are available on request. 2. Refrigerant charge quantity and shipping weights will vary based on tube count. 3. Shipping weights are based on fully assembled and charged units. 4. Refer to product drawings for detailed weight information.

Superior sound reduction

OptiView control centre

 A-Weighted sound pressure pressure level (dBA (re: 20µPa)) Measured in accordance with AHRI-575

Competitor 

YORK® YMC2 5 dBA*

% Chiller full load The YMC 2  chiller is so much quieter than competitive magnetic-bearing chillers,

The OptiView control centre provides complete diagnostics 

it sounds about half as loud. *Note: each segment on the t he Y axis = 5 dBA.

to speed troubleshooting.

  s   p   m   u    P    t   a   e    H    &   s   r   e    l    l    i

Manufacturer reserves the rights to change specications without prior notice.  

york air-conditioning products

YK Water-cooled centrifugal chiller Cooling capacities from 800 kW to 11250 kW Available congurations that meet A Class energy efciency levels at Eurovent Standard Conditions.

Features

 

• The YORK YK chiller is designed for air conditioning and process applications.

• This chiller is designed for indoor mechanical room installation and it requires a cooling tower for heat dissipation

• The high efciency single-stage centrifugal compressor is powered by an open-drive motor. This provides exibility to operate the chiller with electricity, steam, or gas depending on utility rates.

• The inherent design exibility of this chiller allows it to be precisely selected for any building load prole.

• The YK utilizes a falling lm evaporator to increase chiller efciency and reduce refrigerant charges, which makes it ideal for LEED®  building applications.

   t   u    p    n    i    r    e   w    o    p    /    R  y    t    E    i    c    E    a    p    a    c    g    n    i    l    o    o    C

Constant speed Variable speed

Cooling capacity

OptiView panel

Speed comparison

 

38/39

Nominal capacity Model

Cooling capacity kW 800 - 2100 1750 - 2800 2400 - 3800 3200 -9850

Code Q3 - Q7

YK

P7 - P9 H9 K1 - K7

YK - E P K7 & Q3 Cooling capacities at 7°C leaving chilled water and 30 °C entering ent ering condensed water.

8800 - 11250

Heat Recovery

Medium Voltage Variable Speed Drive

The YK Heat Recovery option can be used for domestic hot water preheat, process heat, facility air reheat, and humidity control. Heat recovery delivers operational savings, CO2 reductions, and reduced water consumption.

YORK has a full line of unit mounted and oor mounted Variable Speed Drives, from 380V to 11,000V, to maximize operational savings at off design conditions; which typically occur 99% of the time!

Quick Start Utilize Quick Start technology to improve chiller starting times and get back to setpoint up to 70% faster than standard chiller designs! Total: 10 minutes, 12 seconds

Return to Setpoint

6 minutes 3 seconds

Time for a 1750 kW chiller  to return to specied chiller water Setpoint 7 0  0%   I mp r  r o  ov     e  v em   e nt 

Total: 3 minutes, 2 seconds Restart

3 minutes 54 seconds

2 minutes 2 seconds 45 seconds

Standard chiller

Quick Start feature

Return to Setpoint Restart

  s   p   m   u    P    t   a   e    H    &   s   r   e    l    l    i    h    C

Manufacturer reserves the rights to change specications without prior notice.  

york air-conditioning products

YIA Single stage hot water or steam powered

absorption chiller

Cooling capacities from 280 kW to 3150 kW

Features YIA chillers are available using low pressure steam or hot water. Compared to electrically driven chillers YIA 

chillers can dramatically lower system operating costs when using waste heat. Applications particularly well suited to the YORK YIA absorption chiller include cogeneration, waste heat recovery from diesel or gas engine jacket water, turbine air inlet cooling and district heating and cooling installations.

Hot water units Hot water units can operate with entering water temperature from 80 to 128°C. Steam units Steam units can operate with a steam pressure at generator inlet from 0.2 barg to 0.95 barg. Refrigerant cycle The YORK YIA high efciency single-stage absorption refrigeration cycle uses water as the refrigerant and lithium bromide as the absorbent. It is the strong afnity and ease of seporation that these two substances have for each other that makes the cycle work. The entire process occurs in hermetic vessels in a near complete vacuum. By using the environmental friendly ADVAGuard 750 inhibitor the internal corrosion rate and hydrogen generation is up to 8 times less than using lithium molybdate.

Chiller control The YORK YIA chiller utilizes the OptiView control panel for advanced chiller control and building system integration.

Smart Purge is included to eliminate the need for time consuming manual purging of the chiller system.

 

40/41

Nominal capacity YIA Model

1A1

1A2

2A3

2A4

2B1

3B2

3B3

4B4

4C1

5C2

5C3

Cooling Capacity kW EER (low temperature hot water)

280 0,61

3 21 0,68

406 0,69

465 0,69

506 0,69

60 6 0,69

674 0,69

757 0,69

760 0,68

9 28 0,69

1048 0,61

YIA Model

6C4

7D1

7D2

8D3

8E1

9E2

10E3

12F1

13F2

14F3

Cooling Capacity kW EER (low temperature hot water)

1145 0,68

1 25 3 0,68

1415 0,68

1535 0,68

1885 0,70

2090 0,70

226 5 0,69

26 7 5 0,70

2940 0,71

3150 0,69

3B3

4B4

4C1

5C2

5C3

6160

6 770

5550

6770

9490

10490

11400

6160 1770 3020 1 226 0

10E3

12F1

13F2

14F3

   h    C

At 7°C leaving chilled water, 95°C entering generator water, and 29.4°C entering condenser water.

Technical data YIA Model Length Width Height Operating weight kg

Dimensions

mm mm mm

YIA Model Length Dimensions Width Height Operating weight kg

mm mm mm

1A1

1A2

2A3

2A4

2B1

3B2

3 7 20 1760

4 330

4940 1420

5550

4940

5550 1580 2640

23 20 4950

5500

6130

6590

7900

8540

6C4

7D1 6160 2110

7D2 6770 1670 3540 19840

8D3 7530 2110

8E1

9E2

6870

21800

24110

7 5 30 1770 3 0 20 14760

17890

7 6 30

8 39 0 2480 4 24 0

229 0 3840 26830

29 7 9 0

35550

9150

39050

41140

  s   p   m   u    P    t   a   e    H    &   s   r   e    l    l    i

1 3 6 20

Manufacturer reserves the rights to change specications without prior notice.  

york air-conditioning products

YPC-ST Two-stage steam fed absorption chiller Cooling capacities from 1055 kW to 2370 kW

Features • The YORK YPC high efciency two-stage absorption chiller uses

• ADVAGuard750 is used in YORK absorption chillers to extend chiller life by reducing the corrosion and non-condensable gas generation rates by more than eight (8) times beyond conventional molybdate

water as the refrigerant and lithium bromide as the absorbent.

• The YORK YPC chiller is designed for chilled water applications.

inhibitors.

• Product quality, reliability, and service after the sale is evident by having many YORK brand absorption chillers in operation for more than 35 years.

• An automatic refrigerant purge system is utilized to eliminate the need for time consuming manual purging of the chiller.

Nominal capacity and technical data YPC-ST Model

Cooling Capacity (kW) Length / Width / Height (m) Operating weight (kg)

14SC

16SL

17S

18S

19S

1055 5.1 / 1.9 / 2.3 11030

1547 6.0 / 2.3 / 2.6 17150

1705 5.9 / 2.3 / 2.6 17510

2039 7.0 / 2.3 / 2.8 20780

2 37 3 8.0/2.3/2.8 24190

Leaving chilled liquid 7°C Entering To Tower wer Water 30°C. Entering Steam 8 psi.

Manufacturer reserves the rights to change specications without prior notice.  

42/43

  s   p   m   u    P    t   a   e    H    &   s   r   e    l    l    i

YPC-F Two-stage direct red chiller-heater Cooling capacities from 703 kW to 2370 kW Heating capacities from 565 kW to 1970 kW

   h    C

Features YPC-F is designed to provide both chilled or hot water. Both cooling and heating operations, with hot water up to 60°C, are performed through the evaporator as standard. Optionally an additional hot water heat exchanger providing hot water up to 79,4°C can be installed. With this option a parallel cooling and heating operation is possible. Refrigerant cycle The YORK YPC high efciency two-stage absorption refrigeration cycle uses water as the refrigerant and lithium bromide as the absorbent. It isthat the makes strong afnity that these two substances for each other the cycle work. The entire processhave occurs in hermetic vessels in a near complete vacuum.

YORK’s exclusive two-way split of solution ow allows the unit to operate at much lower solution concentrations and temperatures than in series ow systems. This dramatically increases the efciency of the unit and virtually eliminates crystallisation problems. By using the environmentally friendly ADVAGuard 750 inhibitor the internal corrosion rate and hydrogen generation is up to 8 times less than using lithium molybdate.

Burner YPC-F can be operated by either natural gas, propane gas or fuel oil. units Capacity control is accomplished by modulating the burner’s ring rate.

Nominal capacity and technical data YPC-F Model

Cooling Capacity (kW) Heating Capacity (kW) Length / Wi Width / He Height (m) Operating weight (kg)

12SC

13SC

14SC

15SL

16S

16SL

17S

18S

19S

703 563 4.0/1.9/2.3 9490

809 6 75 4.0/2.0/2.3 10830

1055 844 5.0/1.9/2.3 12130

1231 1013 5.0/2.5/2.7 17360

1407 1125 5.0/2.5/2.7 17580

1547 1268 6.0/2.6/2.8 21180

1705 1407 6.0/2.6/2.8 21580

2039

2 37 3 1969 8.0/2.7/3.0 29 7 20

Leaving chilled liquid 7°C Entering To Tower wer Water 30°C. Leaving Hot Water 60°C.

1688

7.0/2.7/3.0 25190

Manufacturer reserves the rights to change specications without prior notice.  

york air-conditioning products

Central Plant Optimization  10 TM

 

44/45

Creating a complex program without programming The System Selection Tool (SST) is a control program generator that relies on dening the characteristics of the chiller plant and its control strategies. The

  s   p   m   u    P    t   a   e    H    &   s   r   e    l    l    i    h    C

tool supports selection and sequencing of 

• up to eight chillers of different sizes

• up to eight (each) primary and secondary chilled water pumps of varying pumping capacities • up to eight condenser water pumps • cooling towers and bypass valve, including single speed, multi-speed, and vernier control • devices that considers user-dened efciency rating, runtime equalization, and the number-ofnumber-of-starts/number-of starts/number-of-stops -stops equalization Furthermore, control denition for the chiller plant in a single Field Equipment Controller (FEC)/Network Controller Engine (NCE), if supported by available memory and point Input/Output (I/O), or split across multiple FECs/NCEs, is offered.

Flexibility, ready for use A variety of primary control strategies are also available, including

• measuring building chilled-water ow and differential temperature • chillers’ kW load ow through a decoupler pipe in a primary/secondary system differential temperature only in a constant speed chilled water pump system It is also possible to select dozens of secondary strategies, such as • open loop control of the cooling towers (as dened by the American Society of Heating, Refrigerating and Air-Conditioning Engineers) • closed loop control of condenser-water setpoint After making the selections, SST generates a complete program by linking together appropriate software modules. This process removes the variability commonly found in totally custom-generated programs using a traditional software program editor. Once the software modules are linked, the tool allows the entry of all equipment parameters. The resulting program can also be run in a simulator mode to verify proper operation before downloading it into Metasys ®.

Manufacturer reserves the rights to change specications without prior notice.  

york air-conditioning products

 

46/47

Air HandlingDevices Systems & Terminal custom & modular air handling

units

fan coil units close control units s m a r t p a c - f a c to to r y p a c k a g e d c o n t r o l s

 

york air-conditioning products

YMA Custom air handling units A complete range from 0.25 to 50 m3/s

Features The YMA family of air handling units consists of a range of models having air volumes ranging from 0.25 m3/s to 50 m3/s and total static pressures as high as 2000 Pascal: to ensure maximum exibility and the best solution for your application, units are available in increments of 40mm in height and 50mm in width. YMA Air Handling Units can be manufactured in varied

Units may include combinations of any of the following: - Single or double decked units. - Indoor or outdoor applications - Outdoor units are   available with a at or sloping roof, louvres, rainhoods,   birdscreens and special nishes.

congurations, with a wide selection of components, to meet customer requirements. Units are also available in line with the requirements of hospital sector specications.

  Where space constraints restrict the size of a single item   modules can easily be aligned and locked together by   gaskets and stainless steel bolts inserted into factory

- Site assembled units.

  predrilled assembly holes.

- Air mixing boxes and various lter options. - Gas red burners. - Cooling and heating coils. - Humidiers - Heat recovery systems. - UV sterilising lamps. - Dessicant and thermal wheels. - Sound attenuation.

- ATEX Certication. - Factory tted controls and sensors with YORK SmartPAC Factory Packaged Controls.   These include all necessary piping,central wiring,air controls and refrigeration equipment to provide a complete conditioning plant.

Manufacturer reserves the rights to change specications without prior notice.  

48/49

  s   e   c    i   v   e    D    l    a   n    i   m   r   e    T    &

YMD Modular air handling units A complete range from 0.4 to 17 m3/s

  s   m   e    t   s   y    S   g   n    i    l    d   n   a    H   r    i    A

Features

Options/Accessories

• Fixed aspect ratio design • Choice of congurations • Short lead time • Units tted with plug fans and frequency inverter as standard • Suitable for internal or external mounting • Web based selection tool

• Choice of heat recovery devices with up to 70% efciency • Can be supplied with YORK SmartPac Factory Packaged Controls • Hygenic type construction option • CFC free foam or mineral wool inll • Sound attenuator option for sound reduction

Main features !

@ #

1- The lter guarantees comfort and good health by providing clean air to the facility. 2- Cross-Flow Heat Exchanger gives 70% of heat recovery, thus reducing running cost. 3- Fan with variable speed control ensures the AHU operates at maximum efciency and at reduced sound levels.

$

4- The frequency inverter enables the user to control the ow volume of air supplied by the central system. 5- Cooler means comfort, freshness and a nice cool climate and indispensable feature feature on hot days.

%

^

6- Thanks to the Heater, the supply air is delivered at the required temperature.

Manufacturer reserves the rights to change specications without prior notice.  

york air-conditioning products

YORK® Fan Coil units

 

50/51

An extensive offering  • One of the most versatile ranges of fan coils coi ls on the market today. Wall and ceiling mounted units, exposed or concealed with centrifugal fan, are included, and with cooling capacities ranging from 0.6 kW to 15.1 kW. • Dramatic electrical consumption reduction of up to 40% comparative to previous models. This is achieved thanks to the supply of all YORK® Fan Coil Units equipped with centrifugal fans and electric motors, and with 6 speed motors as standard to offer greater exibility in the selection of products. • Energy saving brushless motor technology option available. Its combination with a dedicated frequency inverter and unit controller to regulate the fan speed enables higher efciencies, even at low rotational speeds, lower unit noise, constant speed characteristics and an increase in motor lifetime expectancy. In comparison to the traditional units equipped with asynchronous three-speedmotors, units with brushless motors can obtain a considerable energy saving, by reducing the power consumption by up to 70%. • A full range of factory tted Johnson Controls valve and pre-congured control options is offered. This in addition to a patented ‘wireless’ control option - offering greater exibility in the installation of units, with the highest precision in monitoring and maintaining the desired comfort conditions. • High pressure ‘Blower’ units are also available. They can offer up to 23kw of cooling at External Static Pressures P ressures of up to 250Pa, and are complemented with a full range of options and accessories covering items such as electrical heating battery, air inlet/outlet diffusers and condensate pumps.

  s   e   c    i   v   e    D    l    a   n    i   m   r   e    T    &

  s   m   e    t   s   y    S   g   n    i    l    d   n   a    H   r    i    A

Manufacturer reserves the rights to change specications without prior notice.  

york air-conditioning products

®

YORK  Close Control units

 

52/53

An extensive offering 

 

• cooling capacities of up to 220kw (chilled water) or 100kw (direct expansion) with optional free cooling models. Up ow

• low component face velocities, for a lower total pressure drop and reduced energy consumption

or down ow conguration, either as self-contained packaged units or suitable for connection to remote condensers, are also available • optional direct expansion units tted with scroll compressors, which have much lower noise and energy consumption than reciprocating compressors • R410a refrigerant units available • optional Free Cooling coil to reduce energy consumption required through use of mechanical cooling • plug fan with Electronically Commuted ‘EC’ fans option, to allow fully modulating control of airow

• minimised dimensions, enabling one of the market’s greatest ratios between sensible cooling capacity and base foot print

  s   e   c    i   v   e    D    l    a   n    i   m   r   e    T    &

  s   m   e    t   s   y    S   g   n    i    l    d   n   a    H   r    i    A

Manufacturer reserves the rights to change specications without prior notice.  

york air-conditioning products

SmartPac

100% 90% 80% 70% 60% 50%

Wiring & Installati Installation on

40%

Control Panel

30%

Commissioning

20%

Engineering

10% 0%

Sitee Fit Sit Fitte ted d Manu Manufac factu ture rerr

Facto Fa ctory ry Fi Fitt tted ed “Sm “Smart artPa Pac” c”

SmartPac and YORK® Air Handling units The Air Handling Unit arrives on site ready to connect to the site network, and nal commission is simplied through the unit’s keypad and display.

Panel Power wiring, controls wiring, Variable Speed Drive, preengineered controller and required peripheral devices are all supplied, factory tted and tested.

Controls

 

54/55

SmartPac and YORK® Roof Top & Close Control units Factory packaged controls’ solution enable, to dramatically reduce

on-site commissioning costs. Both are delivered to site with preinstalled controls, factory tested and ready to apply the power.

SmartPac and YORK®  Fan Coil units YORK® Fan Coil Units are available with

factory packaged controls and numerous options for controllers and valves to allow reduced installation time on site.  Either EUBACcontrollers approved are or alternative congurable offered, and a choice of BACNet, N2 Open or LON communication options is no extra cost. Valve requirements can also be met with a wide range of modulating and on/off actuators and isolation valves available and factory tted.

SmartPac and YORK® Standard Control panel With a standardized design the YORK® Airside Equipment is a cost effective solution. Furthermore, Variable

Speed Drives give extra efciency communicating the Johnson controller in either full native BACNet or LON or N2 protocols allowing seamless communication with existing control systems.

  s   e   c    i   v   e    D    l    a   n    i   m   r   e    T    &

  s   m   e    t   s   y    S   g   n    i    l    d   n   a    H   r    i    A

Manufacturer reserves the rights to change specications without prior notice.  

york air-conditioning products

 

56/57

Comprehensive Building Solutions light commercial air conditioning i n d u s t r i a l r e f r i g e r at at i o n ®

me ta sy s   b u i l d i n g a u t o m a t i o n a n d control

systems

 

york air-conditioning products

Light commercial air conditioning

Hydro systems

Air systems

Johnson Controls designs, manufactures and services a wide range of products for air conditioning markets, including water and air cooled chillers, fan coil units plus controls. A wide range

A complete range of air systems are designed, produced and fully factory tested in Europe. This ensures high tech products with unbeatable lead time and low energy solution with enhanced features. Johnson Controls YKlon control board tted in the whole range gives access to remote monitoring, helping service and maintenance to keep the units operative in optimum conditions.

of solutions is offered to meet all needs and make the end users

comfortable with sophisticated solutions.

 

58/59

  s   n   o    i    t   u    l   o    S   g   n    i    d    l    i   u    B   e    i   v   s   n   e    h   e   r   p   m   o    C

Manufacturer reserves the rights to change specications without prior notice.  

sabroe refrigeration products

Industrial refriger refrigeration ation

HeatPAC

Packaged Package d ammonia heat pump – ready to run HeatPAC is an extremely compact heat pump package based on Sabroe HPO/HPC high-pressure reciprocating compressors, using environmentally environmental ly responsible ammonia as refrigerant. This unique integrated conguration is designed to provide exceptional heat pump performance from the smallest possible footprint, and with only a very small refrigerant charge. Factory assembly and end-of-line capacity testing ensure very high degrees of safety and reliability. reliability.

Main benets: • High reliability – proven components • Fast installation – quick start-up • High efciency – high saving potential

HeatPAC packaged ammonia heat pumps Type

Heating

Cooling

capacity

capacity

HPAC 24-W *) HPAC 26-W *) HPAC 28-W *) HPAC 104-W *) HPAC 106-W *) HPAC 108-W *)

kW

kW

24 0 35 9 484 570 852 1149

202 302 408 478 715 965

Power consumption

EER

kW 38

6.3

R717 charge kg

kg

2020 22 3 0 24 20 26 3 0 3300 39 5 0

57

6.3

77

6.3

93

6.1

20 23 25 28

138

6.2 6.2

48

186

Dry weight

37

Dimensions L

W

H

mm 2800 2850 2900 3050 3750 4050

mm 1000 1000 1000 1000 1000 1000

mm 2000 2000 2000 2000 2000 2000

Condenser water inlet +64°C, outlet +70°C. Evaporator water inlet +39°C, outlet +34°C. Motor: 3 x 400V / 50Hz, 1470 rpm EER ratio average = heating capacity / power consumption = 6.2  Capacities are nominal values 

*) W = Heat pump unit water/water  **) Mean sound pressure levels in free eld over reecting plane, distance at 1 m. All data are based on sound power measurements.

Sound press. level **) dB(A) 75 76 77 81

82 83

 

60/61

ChillPAC Packaged ammonia chillers – ready to run Johnson Controls offers a comprehensive range of ChillPA ChillPAC C ammonia chillers consisting of

15 models -

optimised to meet the

requirements in different market segments. Customised solutions are also available on request. All units are supplied with supplied with Y/D starters or variable-speed drive as standard. All ChillPAC ammonia chillers are supplied with PED approval (European Pressure Equipment Directive). Other approvals are available on request.

Main benefts: • Fast installation – quick start-up • High reliability – 100% factory tested • Minimised life cycle costs • High safety standards – small refrigerant charge

ChillPAC ChillP AC water chillers (water: inlet +12°C, outlet +7°C) Cooling capacity kW

Type

EER

R717 charge kg

Dry weight kg

L mm

Dimensions W mm

H mm

Sound press.level *) dB(A)

CPAC 104S-A

230

5.1

13

3300

2900

1000

2000

 

78

CPAC 104L-A

294

5.3

15

3476

2900

1000

2000

 

79

CPAC 106S-A

346

5.2

20

 

3725

 

3100

1000

2000

 

79

5.4

18

 

3555

 

3100

1000

2000

 

22

 

3814

3100

1000

2000

80

4037

3300

1000

2000

80

 

4045

3200

1000

2000

4203

3200

1000

2000

 

82

CPAC 104E-A

 

CPAC 106L-A

 

442

CPAC 108S-A CPAC 106E-A

357

5.4

466  

538

 

5.3  

5.4

24  

27

79

81

CPAC 108L-A

590

5.4

30

CPAC 112S-A

695

5.4

36

5120

3800

1000

2200

 

82

CPAC 108E-A

718

5.5

36

4510

3500

1000

2000

 

82

CPAC 112L-A

 

878

 

5.4

43

5633

4200

1000

2200

 

83

CPAC 116S-A

 

923

 

5.3

47

5962

4300

1000

2200

 

83 83

CPAC 112E-A

1066

5.4

 

53

 

6037

4600

1000

2200

 

CPAC 116L-A

1173

5.3

 

58

 

6524

4800

1000

2200

 

CPAC 116E-A

1398

5.3

6678

5000

1000

2200

62

83

84

ChillPAC ChillP AC brine chillers (ethylene glycol 30%: inlet -4°C, outlet -8°C) L mm

Dimensions W mm

H mm

3170

2900

1000

2000

 

78

3341

3000

1000

2000

 

79

17

3471

3000

1000

2000

 

79

3.2

18

3534

3000

1000

2000

 

3.2

20

3971

3000

1000

2000

80 80

Cooling capacity kW

EER

R717 charge kg

Dry weight kg

CPAC 104S-C

117

3.2

13

CPAC 104L-C

151

3.2

15

CPAC 106S-C

173

3.2

CPAC 104E-C

187

Type

CPAC 106L-C

 

CPAC 108S-C

225

 

230

Sound press.level *) dB(A)

79

3.2

20

3743

3200

1000

2000

CPAC 106E-C

 

273

 

3.2

21

3730

3200

1000

2000

CPAC 108L-C

 

297

 

3.2

 

23

3983

3200

1000

2000

 

82 82

 

81

CPAC 112S-C

341

3.2

 

27

 

4749

3800

1000

2200

 

CPAC 108E-C

364

3.2

 

28

 

4230

3400

1000

2000

 

CPAC 112L-C

441

3.2

 

33

5232

4100

1000

2150

CPAC 116S-C

450

3.2

34

5366

4100

1000

2150

CPAC 112E-C

543

3.2

41

5566

4100

1000

2150

5803

4300

1000

2150

6234

4400

1000

2150

CPAC 116L-C CPAC 116E-C

 

587

718

 

3.2 3.2

46  

52

 

 

Condenser: water inlet +30°C, +30°C, outlet +35°C. Motor: 3 x 400 V, V, 50 Hz, 1460 rpm The above data are only valid for the stated temperatures and operating conditions. Capacities are nominal. A = Air conditioning application (temperature above 0°C) C = Chiller application (temperature below 0°C)  *) Mean sound pressure levels in free eld over reecting plane, distance at 1 m. All data are based on sound power measurements made according to ISO 9614-2 

82

84  

83

84 84  

83

  s   n   o    i    t   u    l   o    S   g   n    i    d    l    i   u    B   e    i   v   s   n   e    h   e   r   p   m   o    C

Manufacturer reserves the rights to change specications without prior notice.  

york air-conditioning products

Metasys  Building Automation and Control Systems ®

Ease of use • Easy to congure and deploy • No special training is required to use it • Enhanced Ready Access Portal  (RAP)  (RAP) graphics capability, combined with the tenant user setup capabilities, c apabilities, deliver targeted views of data to any building occupants. It’s also now compatible with Apple iPhone® or iPod® Touch platforms.

More efciency, efciency, less costs • The Energy Essentials leverages the Metasys® Advanced Reporting System to take the existing data and present it in an organized and informative way, providing easy-to-congure, easy-to-use and actionable energy reports • The improved Johnson Controls Central Plant Optimization™ 10 (CPO 10) helps facility managers operate their chiller plants more efciently. CPO algorithms are used to operate and sequence plant equipment in an efcient and reliable manner, manner, and to ensure that runtime, starts and stops are equalized across the individual plant components saving energy and improving reliability in the facility.

 

62/63

  s   n   o    i    t   u    l   o    S   g   n    i    d    l    i   u    B   e    i   v   s   n   e    h   e   r   p   m   o    C

Single platform communication • Enhanced, single platform interface of thousands of different hardwired and wireless systems, devices and equipment. • Even more control options and better information access by users, thanks to: • Field Equipment Controllers redesigning • Terminal Equipment Controller updates and improvem improvements ents • Added wireless and network sensors • Enhanced software and rmware

Wireless Capabilities • Increased control exibility, streamlines retrots and faster download times, thanks to the latest wireless technologies that Metasys® incorporates into more devices. • At system’s user interface, network automation, eld controller or room sensing levels, Wireless Building Technologies from Johnson Controls always result in increased application exibility and cost effectiveness.

Security features

P2000

P2000

Badging Station

Server

• Metasys® now incorporates P2000 Security Management System,

P2000 Work Station

CCTV

whose software and network

controllers ensure the safety of employees and security of company

IP Network

assets.

RS485 / IP Converter

• P2000 open integration platform, designed for interoperability with

a variety of security subsystems including access control, alarm & intrusion detection, video surveillance, visitor management.

2 Doors Controller

CK721

Up to 16 Readers

S321 S300

S300

Intrusion

DVN 5000

Manufacturer reserves the rights to change specications without prior notice.  

About Johnson Controls

Johnson Controls delivers products, services and solutions that increase energy efciency and lower operating costs in buildings for more than one million customers. Operating from 500 branch ofces in more than 150 countries, the company is a leading provider of equipment, controls and services for heating, ventilating, air-conditioning, air-conditioning, refrigeration and security systems. Johnson Controls is involved in more than 500 renewable energy projects including solar, wind and geothermal technologies. Its solutions have reduced carbon dioxide emissions by 13.6 million metric tons and generated savings of $7.5 billion since 2000. Many of the world’s largest companies rely rely on Johnson Controls to manage 1.5 billion square feet of their commercial real estate.

© Johnson Controls, 2011

www.johnsoncontrols.com

PUBL-6667

Sponsor Documents

Or use your account on DocShare.tips

Hide

Forgot your password?

Or register your new account on DocShare.tips

Hide

Lost your password? Please enter your email address. You will receive a link to create a new password.

Back to log-in

Close