FBH 100/113 [OPEN] / Luminaire Data Sheet
Luminous emittance 1:
See our luminaire catalog for an image of the
luminaire.
Luminaire classification according to CIE: 100
CIE flux code: 53 84 98 100 70
DIALux 4.12 by DIAL GmbH
Luminous emittance 1:
Page 1
Project 1
03 / 24 / 2016
Operator
Telephone
Fax
e-Mail
Room 1 / Summary
Height of Room: 12.000 ft, Mounting Height: 12.000 ft, Light loss factor:
0.67
Surface
Workplane
Floor
Ceiling
Walls (4)
Values in Footcandles, Scale 1:59
[%]
Eav [fc]
Emin [fc]
Emax [fc]
u0
/
20
80
50
36
31
9.18
22
23
21
7.64
9.78
45
38
13
39
0.659
0.701
0.832
/
Workplane:
Height:
2.493 ft
Grid:
32 x 32 Points
Boundary Zone:
0.000 ft
Illuminance Quotient (according to LG7): Walls / Working Plane: 0.663, Ceiling / Working Plane: 0.258.
Luminaire Parts List
No.
Pieces
1
42
Designation (Correction Factor)
(Luminaire) [lm]
(Lamps) [lm]
P [W]
626
900
17.3
37800
726.6
FBH 100/113 [OPEN] (1.000)
Total:
26272
Total:
Specific connected load: 2.42 W/sq ft = 0.68 W/sq ft/10 fc (Ground area: 300.01 sq ft)
See our luminaire
catalog for an image of
the luminaire.
Page 3
Project 1
03 / 24 / 2016
Operator
Telephone
Fax
e-Mail
Room 1 / Photometric Results
Total Luminous Flux:
Total Load:
Light loss factor:
Boundary Zone:
Surface
Workplane
Floor
Ceiling
Wall 1
Wall 2
Wall 3
Wall 4
26272 lm
726.6 W
0.67
0.000 ft
Average illuminances [fc]
direct
indirect
total
26
9.38
36
21
9.29
31
0.00
9.18
9.18
13
8.51
22
13
8.65
22
14
9.03
23
13
8.79
22
Reflection factor [%]
Average luminance [cd/m²]
/
20
80
50
50
50
/
21
25
38
37
39
50
38
Uniformity on the working plane
u0: 0.659 (1:2)
Emin / Emax: 0.520 (1:2)
Illuminance Quotient (according to LG7): Walls / Working Plane: 0.663, Ceiling / Working Plane: 0.258.
Specific connected load: 2.42 W/sq ft = 0.68 W/sq ft/10 fc (Ground area: 300.01 sq ft)