Powered by

PERFORMANCE • High efficiency, polycrystalline solar cells with high transmission and textured glass delivering a module efficiency of up to 13.5%, minimizing installation costs and maximizing the kWh output of your system per unit area. • Power tolerance of +/-3% minimizing PV system mismatch losses. QUALITY AND RELIABILITY • Industry leading in-house manufacturing of polysilicon, ingots, wafers, cells and modules ensures tight control of our material and production quality. • Robust, corrosion resistant aluminum frame independently tested to withstand wind loads of 2.4 kPa and snow loads of 5.4 kPa ensuring a stable mechanical life for your modules. • Module packaging optimized to protect product during transporta tion and minimize on-site waste. • This type of module is commenly use for the small off-grid system. • Manufacturing facility certified by TÜV Rheinland to ISO 9001:2008,ISO 14001:2004 and BS OHSAS 18001:2007. QUALIFICATIONS AND CERTIFICATES IEC 61215, IEC 61730, UL 1703 and ULC 1703, UL Fire Safety Class C, ISO 9001:2008, ISO 14001:2004, BS OSHAS 18001:2007, SA 8000, PV Cycle ABOUT YINGLI GREEN ENERGY • Yingli Green Energy Holding Company Limited (NYSE: YGE) is one of the world’s largest fully vertically integrated PV manufacturers. With over 2 GW of modules installed globally, Yingli is a leading solar energy company built upon proven product reliability, sustainability and performance. Yingli is the first renewable energy company and the first Chinese company to sponsor the FIFA World CupTM.
WARRANT IE S

10-year limited product warranty Limited power warranty: 10 years at 91.2% of the minimal rated power output, 25 years at 80.7% of the minimal rated power output.

In compliance with our Warranty Terms and Conditions.

QUAL IF ICAT IONS & CERT IF ICAT ES: IEC 61215, IEC 61730, CE, ISO 9001:2008, ISO 14001:2004, BS OHSAS 18001:2007, SA 8000, PV Cycle

Trans

Water
QUALITY PRODUCTS

1

Solar Modules
Powered by

ELECTRICAL PERFORMANCE
Electrical parameters at Standard Test Conditions (STC) Module type Power output Power output tolerances Module efficiency Voltage at P max Current at Pmax Open-circuit voltage Short-circuit current Pmax ΔPmax ηm Vmpp I mpp Voc I sc W W % V A V A
YL250P-29b

YL 250P-29B

GENERAL CHARACTERISTICS
Dimensions (L / W / H) Weight 1650mm / 990mm / 40mm 19.1kg

250 +/- 3 15.3 30.4 8.24 38.4 8.79

PA C K A G I N G S P E C I F I C AT I O N S
Number of modules per pallet Number of pallets per 40' container Packaging box dimensions (L / W / H) Box weight 26 28 1700mm / 1150mm / 1190mm 534kg

STC: 1000W/m 2 irradiance, 25°C cell temperature, AM1.5g spectrum according to EN 60904-3. Average relative efficency reduction of 5% at 200W/m2 according to EN60904-1. Electrical parameters at Nominal Operating Cell Temperature (NOCT) Power output Voltage at Pmax Current at P max Open-circuit voltage Short-circuit current Pmax Vmpp I mpp Voc I sc W V A V A 181.1 27.6 6.56 35.4 7.12

Unit: mm

NOCT: open-circuit module operation temperature at 800W/m 2 irradiance, 20°C ambient temperature, 1m/s wind speed.

THERMAL CHARACTERISTICS
Nominal operating cell temperature Temperature coefficient of P max Temperature coefficient of V oc Temperature coefficient of I sc Temperature coefficient of V mpp NOCT γ β Voc α Isc β Vmpp °C %/°C %/°C %/°C %/°C 46 +/- 2 -0.45 -0.33 0.06 -0.45

O P E R AT I N G C O N D I T I O N S
Max. system voltage Max. series fuse rating Limiting reverse current Operating temperature range Max. static load, front (e.g., snow and wind) Max. static load, back (e.g., wind) Max. hailstone impact (diameter / velocity) 1000V DC 15A 15A -40 to 85°C 5400Pa 2400Pa 25mm / 23m/s

C O N S T R U C T I O N M AT E R I A L S
Front cover (material / thickness) Cell (quantity / material / dimensions / # of busbars) Encapsulant (material) Frame (material / color / anodization color / edge sealing) Junction box (protection degree) Cable (length / cross-sectional area) Plug connector (type / protection degree) low-iron tempered glass / 3.2mm 60 / multicrystalline silicon / 156mm x 156mm / 2 or 3 ethylene vinyl acetate (EVA) anodized aluminum alloy / silver / clear / silicone or tape ≥ IP65 1100mm / 4mm 2 MC4 / IP67 or Amphenol H4 / IP68

Warning: Read the installation manual in its entirety before handling, installing, and operating Yingli Solar module.

• The data do not refer to a single module and they are not part of the offer, they only serve for comparison to different module types.

Trans
2

Water
QUALITY PRODUCTS

Solar Modules
Powered by

YL 085P - 17b
ELECTRICAL PERFORMANCE
Electrical parameters at Standard Test Conditions (STC) Module name Module type Pmax Power output Power output tolerances ΔPmax ηm Module efficiency Voltage at Pmax Current at Pmax Open-circuit voltage Short-circuit current Vmpp I mpp Voc I sc W % % V A V A YGE 85 YL085P-17b 2/3 85 +/- 3 12.8 17.5 4.86 22.0 5.36

GENERAL CHARACTERISTICS
Dimensions (length / width / height) Weight 1010mm / 660mm / 35mm 7.88 kg

PACKAGING SPECIFICATIONS
Number of modules per box Packaging box dimensions (length / width / height) 4 1040mm / 690mm / 200mm

STC: 1000W/m 2 irradiance, 25°C T module , AM 1.5g spectrum according to EN 60904-3. Ave. efficiency reduction of 5% at 200W/m2 according to EN 60904-1.

Unit: mm
660 626 35

Electrical parameters at Nominal Operating Cell Temperature (NOCT) Power output Voltage at Pmax Current at Pmax Open-circuit voltage Short-circuit current Pmax Vmpp I mpp Voc I sc W V A V A
2

61.7 16.0 3.87 20.1 4.34
irradiance, 20°C T ambient , 1m/s wind speed.

37

NOCT: open-circuit module operation temperature at 800W/m

THERMAL CHARACTERISTICS
Nominal operating cell temperature Temperature coefficient of Pmax Temperature coefficient of Voc Temperature coefficient of Isc NOCT γ β Vo c α Isc °C %/°C %/°C %/°C 46 +/- 2 -0.37 0.06
1010

-0.45

2-Ø 6 Grounding holes

OPERATING CONDITIONS
Max. system voltage Max. series fuse rating Limiting reverse current Operating temperature range Max. static load, front (e.g., snow and wind) Max. static load, back (e.g., wind) Hailstone impact (hailstone diameter / impact velocity) 50V DC 10A
Do not apply external voltages larger than Voc of the module

4-6.5X8 Mounting slots 8-Ø 4 Drainage holes

A A 6.5

-40 to 85°C 2400Pa 2400Pa 25mm / 23m/s
35

CONSTRUCTION MATERIALS
Front cover (material / thickness) Cell (quantity / type / dimensions) Encapsulant (material) Frame (material / color / anodization color) low-iron tempered glass / 3.2mm 36 / multicrystalline / 104mm x 156mm ethylene vinyl acetate (EVA) anodized aluminum alloy / silver / clear

SECTION A–A

29

Warning: Read the installation manual in its entirety before handling, installing, and operating Yingli Solar module.

are not guaranteed. • The data do not refer to a single module and they are not part of the offer, they only serve for comparison to different module types.

Trans

Water
QUALITY PRODUCTS

510

3

Solar Modules
Powered by

YL 100P - 17b
ELECTRICAL PERFORMANCE
Electrical parameters at Standard Test Conditions (STC) Module name Module type Pmax Power output Power output tolerances ΔPmax ηm Module efficiency Voltage at Pmax Current at P max Open-circuit voltage Short-circuit current Vmpp Impp Voc Isc W % % V A V A YGE 100 YL100P-17b 4/5 100 +/- 3 12.9 17.0 5.88 21.5 6.55

GENERAL CHARACTERISTICS
Dimensions (length / width / height) Weight 1172mm / 660mm / 35mm 8.3kg

PACKAGING SPECIFICATIONS
Number of modules per box Packaging box dimensions (length / width / height) 4 1200mm / 690mm / 200mm

STC: 1000W/m 2 irradiance, 25°C T module , AM 1.5g spectrum according to EN 60904-3. Ave. efficiency reduction of 5% at 200W/m2 according to EN 60904-1.

Unit: mm
660 626 35 37

Electrical parameters at Nominal Operating Cell Temperature (NOCT) Power output Voltage at P max Current at P max Open-circuit voltage Short-circuit current Pmax Vmpp I mpp Voc I sc W V A V A 72.6 15.5 4.68 19.2 5.31
ambient

NOCT: open-circuit module operation temperature at 800W/m 2 irradiance, 20°C T

, 1m/s wind speed.

THERMAL CHARACTERISTICS
Nominal operating cell temperature Temperature coefficient of Pmax Temperature coefficient of Voc Temperature coefficient of I sc NOCT γ β Vo c α Isc °C %/°C %/°C %/°C 46 +/- 2 -0.37 0.06
1172

-0.45

2-Ø 6 G rounding holes

OPERATING CONDITIONS
Max. system voltage Max. series fuse rating Limiting reverse current Operating temperature range Max. static load, front (e.g., snow and wind) Max. static load, back (e.g., wind) Hailstone impact (hailstone diameter / impact velocity) 50VDC 10A Do not apply external voltages larger than Voc of the module -40 to 85°C 2400Pa 2400Pa 25mm / 23m/s

4-6.5X8 Mounting s lots 8-Ø 4 Drainage holes

A

A

6.5

35

CONSTRUCTION MATERIALS
Front cover (material / thickness) Cell (quantity / type / dimensions) Encapsulant (material) Frame (material / color / anodization color) low-iron tempered glass / 3.2mm 36 / multicrystalline / 124.8mm x 156mm ethylene vinyl acetate (EVA) anodized aluminum alloy / silver / clear

SECTION A–A

29

Warning: Read the installation manual in its entirety before handling, installing, and operating Yingli Solar module.

are not guaranteed. • The data do not refer to a single module and they are not part of the offer, they only serve for comparison to different module types.